TY - JOUR A1 - Degering, Christian A1 - Eggert, Thorsten A1 - Puls, Michael A1 - Bongaerts, Johannes A1 - Evers, Stefan A1 - Maurer, Karl-Heinz A1 - Jaeger, Karl-Erich T1 - Optimization of protease secretion in Bacillus subtilis and Bacillus licheniformis by screening of homologous and herologous signal peptides JF - Applied and environmental microbiology N2 - Bacillus subtilis and Bacillus licheniformis are widely used for the large-scale industrial production of proteins. These strains can efficiently secrete proteins into the culture medium using the general secretion (Sec) pathway. A characteristic feature of all secreted proteins is their N-terminal signal peptides, which are recognized by the secretion machinery. Here, we have studied the production of an industrially important secreted protease, namely, subtilisin BPN′ from Bacillus amyloliquefaciens. One hundred seventy-three signal peptides originating from B. subtilis and 220 signal peptides from the B. licheniformis type strain were fused to this secretion target and expressed in B. subtilis, and the resulting library was analyzed by high-throughput screening for extracellular proteolytic activity. We have identified a number of signal peptides originating from both organisms which produced significantly increased yield of the secreted protease. Interestingly, we observed that levels of extracellular protease were improved not only in B. subtilis, which was used as the screening host, but also in two different B. licheniformis strains. To date, it is impossible to predict which signal peptide will result in better secretion and thus an improved yield of a given extracellular target protein. Our data show that screening a library consisting of homologous and heterologous signal peptides fused to a target protein can identify more-effective signal peptides, resulting in improved protein export not only in the original screening host but also in different production strains. Y1 - 2010 U6 - https://doi.org/10.1128/AEM.01146-10 SN - 1098-5336 (E-Journal); 0003-6919 (Print); 0099-2240 (Print) VL - 76 IS - 19 SP - 6370 EP - 6378 PB - American Society for Microbiology CY - Washington, DC ER - TY - JOUR A1 - Defosse, Jerome A1 - Kleinschmidt, Joris A1 - Schmutz, Axel A1 - Loop, Torsten A1 - Staat, Manfred A1 - Gatzweiler, Karl-Heinz A1 - Wappler, Frank A1 - Schieren, Mark T1 - Dental strain on maxillary incisors during tracheal intubation with double-lumen tubes and different laryngoscopy techniques - a blinded manikin study JF - Journal of Cardiothoracic and Vascular Anesthesia KW - anaesthetic complications KW - dental trauma KW - difficult airway KW - double-lumen tube intubation KW - videolaryngoscopy Y1 - 2022 U6 - https://doi.org/10.1053/j.jvca.2022.02.017 SN - 1053-0770 VL - 36 IS - 8, Part B SP - 3021 EP - 3027 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - de Blois, Eric A1 - de Zanger, Rory M. S. A1 - Paulßen, Elisabeth A1 - Sze Chan, Ho A1 - Breeman, Wouter A. P. T1 - Semi-automated system for concentrating 68Ga-eluate to obtain high molar and volume concentration of 68Ga-Radiopharmaca for preclinical applications JF - Nuclear Medicine and Biology N2 - 68Ga-radiopharmaceuticals are common in the field of Nuclear Medicine to visualize receptor-mediated processes. In contrast to straightforward labeling procedures for clinical applications, preclinical in vitro and in vivo applications are hampered for reasons like e.g. volume restriction, activity concentration, molar activity and osmolality. Therefore, we developed a semiautomatic system specifically to overcome these problems. A difficulty appeared unexpectedly, as intrinsic trace metals derived from eluate (Zn, Fe and Cu) are concentrated as well in amounts that influence radiochemical yield and thus lower molar activity. Y1 - 2018 U6 - https://doi.org/10.1016/j.nucmedbio.2018.06.006 VL - 64-65 SP - 16 EP - 21 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dashevsky, Alexey V. A1 - Lanzl, Ines M. A1 - Kotliar, Konstantin T1 - Non-penetrating intracanalicular partial trabeculectomy via the ostia of Schlemm's canal JF - Graefe's Archive for Clinical and Experimental Ophthalmology Y1 - 2011 SN - 0721-832x VL - 249 IS - 4 SP - 565 EP - 573 PB - Springer CY - Berlin ER - TY - JOUR A1 - Darmo, J. A1 - Schäffer, F. A1 - Förster, Arnold A1 - Kordos, P. T1 - Beryllium doped low-temperature-grown MBE GaAs: material for photomixing in the THz frequency range JF - ASDAM 2000 : conference proceedings / edited by Jozef Osvald ... [et al.] Y1 - 2000 SN - 0780359399 N1 - International Conference on Advanced Semiconductor Devices and Microsystems ; (3rd : ; 2000 : ; Smolenice, Slovakia) SP - 147 EP - 150 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Dantism, Shahriar A1 - Takenaga, Shoko A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Differential imaging of the metabolism of bacteria and eukaryotic cells based on light-addressable potentiometric sensors JF - Electrochimica Acta N2 - A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric sensor with an electrolyte/insulator/semiconductor (EIS) structure, which is able to monitor analyte concentrations of (bio-)chemical species in aqueous solutions in a spatially resolved way. Therefore, it is also an appropriate tool to record 2D-chemical images of concentration variations on the sensor surface. In the present work, two differential, LAPS-based measurement principles are introduced to determine the metabolic activity of Escherichia coli (E. coli) K12 and Chinese hamster ovary (CHO) cells as test microorganisms. Hereby, we focus on i) the determination of the extracellular acidification rate (ΔpH/min) after adding glucose solutions to the cell suspensions; and ii) recording the amplitude increase of the photocurrent (Iph) related to the produced acids from E. coli K12 bacteria and CHO cells on the sensor surface by 2D-chemical imaging. For this purpose, 3D-printed multi-chamber structures were developed and mounted on the planar sensor-chip surface to define four independent compartments, enabling differential measurements with varying cell concentrations. The differential concept allows eliminating unwanted drift effects and, with the four-chamber structures, measurements on the different cell concentrations were performed simultaneously, thus reducing also the overall measuring time. Y1 - 2017 U6 - https://doi.org/10.1016/j.electacta.2017.05.196 SN - 0013-4686 VL - 246 SP - 234 EP - 241 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dantism, Shahriar A1 - Takenaga, Shoko A1 - Wagner, Patrick A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Determination of the extracellular acidification of Escherichia coli K12 with a multi-​chamber-​based LAPS system JF - Physica status solidi (a) N2 - On-line monitoring of the metabolic activity of microorganisms involved in intermediate stages of biogas production plays an important role to avoid undesirable “down times” during the biogas production. In order to control this process, an on-chip differential measuring system based on the light-addressable potentiometric sensor (LAPS) principle combined with a 3D-printed multi-chamber structure has been realized. As a test microorganism, Escherichia coli K12 (E. coli K12) were used for cell-based measurements. Multi-chamber structures were developed to determine the metabolic activity of E. coli K12 in suspension for a different number of cells, responding to the addition of a constant or variable amount of glucose concentrations, enabling differential and simultaneous measurements. Y1 - 2016 U6 - https://doi.org/10.1002/pssa.201533043 SN - 1862-6300 VL - 213 IS - 6 SP - 1479 EP - 1485 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Dantism, Shahriar A1 - Röhlen, Desiree A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Optimization of Cell-Based Multi-Chamber LAPS Measurements Utilizing FPGA-Controlled Laser-Diode Modules JF - physica status solidi a : applications and materials sciences N2 - A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric device, which detects concentration changes of an analyte solution on the sensor surface in a spatially resolved way. It uses a light source to generate electron–hole pairs inside the semiconductor, which are separated in the depletion region due to an applied bias voltage across the sensor structure and hence, a surface-potential-dependent photocurrent can be read out. However, depending on the beam angle of the light source, scattering effects can occur, which influence the recorded signal in LAPS-based differential measurements. To solve this problem, a novel illumination unit based on a field programmable gate array (FPGA) consisting of 16 small-sized tunable infrared laser-diode modules (LDMs) is developed. Due to the improved focus of the LDMs with a beam angle of only 2 mrad, undesirable scattering effects are minimized. Escherichia coli (E. coli) K12 bacteria are used as a test microorganism to study the extracellular acidification on the sensor surface. Furthermore, a salt bridge chamber is built up and integrated with the LAPS system enabling multi-chamber differential measurements with a single Ag/AgCl reference electrode. Y1 - 2018 U6 - https://doi.org/10.1002/pssa.201800058 SN - 1862-6319 VL - 215 IS - 15 SP - Article number 1800058 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Dantism, Shahriar A1 - Röhlen, Desiree A1 - Wagner, Torsten A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - A LAPS-based differential sensor for parallelized metabolism monitoring of various bacteria JF - Sensors N2 - Monitoring the cellular metabolism of bacteria in (bio)fermentation processes is crucial to control and steer them, and to prevent undesired disturbances linked to metabolically inactive microorganisms. In this context, cell-based biosensors can play an important role to improve the quality and increase the yield of such processes. This work describes the simultaneous analysis of the metabolic behavior of three different types of bacteria by means of a differential light-addressable potentiometric sensor (LAPS) set-up. The study includes Lactobacillus brevis, Corynebacterium glutamicum, and Escherichia coli, which are often applied in fermentation processes in bioreactors. Differential measurements were carried out to compensate undesirable influences such as sensor signal drift, and pH value variation during the measurements. Furthermore, calibration curves of the cellular metabolism were established as a function of the glucose concentration or cell number variation with all three model microorganisms. In this context, simultaneous (bio)sensing with the multi-organism LAPS-based set-up can open new possibilities for a cost-effective, rapid detection of the extracellular acidification of bacteria on a single sensor chip. It can be applied to evaluate the metabolic response of bacteria populations in a (bio)fermentation process, for instance, in the biogas fermentation process. Y1 - 2019 U6 - https://doi.org/10.3390/s19214692 SN - 1424-8220 VL - 19 IS - 21 PB - MDPI CY - Basel ER - TY - JOUR A1 - Dantism, Shahriar A1 - Röhlen, Desiree A1 - Selmer, Thorsten A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Quantitative differential monitoring of the metabolic activity of Corynebacterium glutamicum cultures utilizing a light-addressable potentiometric sensor system JF - Biosensors and Bioelectronics Y1 - 2019 U6 - https://doi.org/10.1016/j.bios.2019.111332 VL - 139 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dantism, Shahriar A1 - Röhlen, Desiree A1 - Dahmen, Markus A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - LAPS-based monitoring of metabolic responses of bacterial cultures in a paper fermentation broth JF - Sensors and Actuators B: Chemical N2 - As an alternative renewable energy source, methane production in biogas plants is gaining more and more attention. Biomass in a bioreactor contains different types of microorganisms, which should be considered in terms of process-stability control. Metabolically inactive microorganisms within the fermentation process can lead to undesirable, time-consuming and cost-intensive interventions. Hence, monitoring of the cellular metabolism of bacterial populations in a fermentation broth is crucial to improve the biogas production, operation efficiency, and sustainability. In this work, the extracellular acidification of bacteria in a paper-fermentation broth is monitored after glucose uptake, utilizing a differential light-addressable potentiometric sensor (LAPS) system. The LAPS system is loaded with three different model microorganisms (Escherichia coli, Corynebacterium glutamicum, and Lactobacillus brevis) and the effect of the fermentation broth at different process stages on the metabolism of these bacteria is studied. In this way, different signal patterns related to the metabolic response of microorganisms can be identified. By means of calibration curves after glucose uptake, the overall extracellular acidification of bacterial populations within the fermentation process can be evaluated. Y1 - 2020 U6 - https://doi.org/10.1016/j.snb.2020.128232 SN - 0925-4005 VL - 320 IS - Art. 128232 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dantism, S. A1 - Takenaga, S. A1 - Wagner, P. A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Light-addressable Potentiometric Sensor (LAPS) Combined with Multi-chamber Structures to Investigate the Metabolic Activity of Cells JF - Procedia Engineering N2 - LAPS are field-effect-based potentiometric sensors which are able to monitor analyte concentrations in a spatially resolved manner. Hence, a LAPS sensor system is a powerful device to record chemical imaging of the concentration of chemical species in an aqueous solution, chemical reactions, or the growth of cell colonies on the sensor surface, to record chemical images. In this work, multi-chamber 3D-printed structures made out of polymer (PP-ABS) were combined with LAPS chips to analyse differentially and simultaneously the metabolic activity of Escherichia coli K12 and Chinese hamster ovary (CHO) cells, and the responds of those cells to the addition of glucose solution. Y1 - 2015 U6 - https://doi.org/10.1016/j.proeng.2015.08.647 SN - 1877-7058 N1 - Part of special issue "Eurosensors 2015" VL - 120 SP - 384 EP - 387 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dankelmann, Peter A1 - Hellwig, Angelika A1 - Volkmann, Lutz T1 - Inverse degree and edge-connectivity JF - Discrete mathematics Y1 - 2009 SN - 1872-681X (E-Journal); 0012-365X (Print) VL - Vol. 309 IS - Iss. 9 SP - 2943 EP - 2947 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dankelmann, Peter A1 - Hellwig, Angelika A1 - Volkmann, Lutz T1 - On the connectivity of diamond-free graphs JF - Discrete applied mathematics Y1 - 2007 SN - 0166-218X (E-Journal); 1872-6771 (E-Journal); 0166-218X (Print) VL - Vol. 155 IS - Iss. 16 SP - 2111 EP - 2117 ER - TY - JOUR A1 - Daniel, Bernd A1 - Starck, Andreas T1 - Die Anwendung der VOB in der baubetrieblichen Praxis N2 - Eine Einführung in die Anwendung der VOB in der baubetrieblichen Praxis im Rahmen der ergänzenden Schriften zu den Vorlesungen. Die Anwendung der VOB als Vertragsbedingung für einen Bauvertrag ist gängige Praxis, über die der Architekt im Baubetrieb umfassend informiert sein muß. Die Anwendung der VOB im Bauvertrag bedarf der vorherigen Vereinbarung zwischen den Vertragsparteien. Dabei muß die VOB im Ganzen vereinbart werden. Eine Veränderung dieser Bestimmungen führt zur teilweisen Unwirksamkeit der vertraglichen Vereinbarung. Der Architekt, der für seinen Bauherrn die Vergabeunterlagen zusammenstellen muß, haftet für Fehler bei der Formulierung oder der Zusammenstellung. Es ist daher für den Architekten unerläßlich, die vertraglichen Zusammenhänge zu kennen. Dieser Fachaufsatz soll zu einem sicheren Umgang mit der VOB als Vertragsgrundlage beitragen. KW - Baubetrieb KW - Bauvertrag KW - VOB KW - Vertragsbedingungen Y1 - 2007 ER - TY - JOUR A1 - Daniel, Bernd A1 - Starck, Andreas T1 - Kostenkontrolle und Kostensteuerung im Hochbau N2 - Textauszug: Nach dem Leistungsbild der HOAI hat der Architekt bei Planung und Baubetrieb vier Stationen der Kostenermittlung entsprechend der DIN 276, Abschnitt 2.3 abzuarbeiten. Der Architekt, der seiner Verantwortung gerecht werden will, wird hier weitere Kontrollmechanismen einbauen wollen. Über die genannten Kostenermittlungen hinaus kennt die DIN 276 daher noch das Erfordernis der Kostenkontrolle in Abschnitt 2.4 und der Kostensteuerung in Abschnitt 2.5. Die Kostensteuerung greift immer dann, wenn die Kostenkontrolle eine Abweichung des Kostenrahmens von den Sollwerten aufzeigt. Dazu müssen die Kontrollinstanzen dort eingebaut werden, wo Korrekturen noch möglich sind. Eine erste Kontrolle der Kosten ist daher zwischen Massenermittlung und Vergabe sinnvoll einzuflechten. Zu diesem Zeitpunkt kann die Planung noch verändert werden, was einen ersten steuernden Eingriff in die Baukosten ermöglicht, und zwar bevor die Angebotsunterlagen verschickt werden. Die Grundlagen zu einer effektiven Kostensteuerung werden in der Mengenermittlung der Leistungsphase 6 gelegt. Wenn dort die Mengen nicht sorgfältig und nachvollziehbar ermittelt wurden, wird der Soll- Ist- Abgleich während der Bauphase nicht frühzeitig genug gelingen, wenn nicht gar ganz entfallen. Es gilt also, dafür zu sorgen, dass die Mengenermittlung zur Vergabe mit entsprechender Sorgfalt und vor Allem „projektnah“ erfolgt. Schätzungen haben hier keine Berechtigung. KW - Projektsteuerung KW - Baukosten KW - Kostenkontrolle KW - Kostensteuerung KW - Kostenermittlung Y1 - 2007 ER - TY - JOUR A1 - Danho, Waleed A1 - Naithani, Vinod K. A1 - Sasaki, André N. A1 - Föhles, Joseph A1 - Berndt, Heinz A1 - Büllesbach, Erika E. A1 - Zahn, H. T1 - Human proinsulin, VII : synthesis of two protected peptides corresponding to the sequences 1—45 and 46—86 of the prohormone JF - Hoppe-Seyler's Zeitschrift für physiologische Chemie Y1 - 1980 U6 - https://doi.org/10.1515/bchm2.1980.361.1.857 SN - 1437-4315 SN - 0018-4888 VL - 361 IS - 1 SP - 857 EP - 863 ER - TY - JOUR A1 - Damrau, Karin T1 - Beyond Solidity - Inventions, Spaces and Concepts for the Elements of Air and Water JF - Architectural design : AD. 69 (1999), H. 3-4 Y1 - 1999 SN - 0003-8504 SP - 22 EP - 33 ER - TY - JOUR A1 - Damrau, Karin T1 - Fantastic Spatial Combinations in Film JF - Architectural design : AD. 70 (2000), H. 1 Y1 - 2000 SN - 0003-8504 SP - 58 EP - 61 ER - TY - JOUR A1 - Damm, Marc André A1 - Sauerborn, Markus A1 - Fend, Thomas A1 - Herrmann, Ulf T1 - Optimisation of a urea selective catalytic reduction system with a coated ceramic mixing element JF - Journal of ceramic science and technology Y1 - 2017 SN - 2190-9385 (Print) U6 - https://doi.org/10.4416/JCST2016-00056 SN - 2190-9385 (Online) VL - 8 IS - 1 SP - 19 EP - 24 PB - Göller CY - Baden-Baden ER -