TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bäcker, Matthias A1 - Pouyeshman, S. A1 - Schnitzler, Thomas A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Biselli, Manfred A1 - Schöning, Michael Josef T1 - A silicon-based multi-sensor chip for monitoring of fermentation processes JF - Physica status solidi (a) : applications and material science. 208 (2011), H. 6 Y1 - 2011 SN - 1862-6319 SP - 1364 EP - 1369 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Murib, Mohammed S. A1 - Tran, Anh Quang A1 - Ceuninck, Ward de A1 - Schöning, Michael Josef A1 - Nesladek, Milos A1 - Serpengüzel, Ali A1 - Wagner, Patrick T1 - Analysis of an optical biosensor based on elastic light scattering from diamond-, glass-, and sapphire microspheres JF - Physica Status Solidi A N2 - Deoxyribonucleic acid (DNA) and protein recognition are now standard tools in biology. In addition, the special optical properties of microsphere resonators expressed by the high quality factor (Q-factor) of whispering gallery modes (WGMs) or morphology dependent resonances (MDRs) have attracted the attention of the biophotonic community. Microsphere-based biosensors are considered as powerful candidates to achieve label-free recognition of single molecules due to the high sensitivity of their WGMs. When the microsphere surface is modified with biomolecules, the effective refractive index and the effective size of the microsphere change resulting in a resonant wavelength shift. The transverse electric (TE) and the transverse magnetic (TM) elastic light scattering intensity of electromagnetic waves at 600 and 1400 nm are numerically calculated for DNA and unspecific binding of proteins to the microsphere surface. The effect of changing the optical properties was studied for diamond (refractive index 2.34), glass (refractive index 1.50), and sapphire (refractive index 1.75) microspheres with a 50 µm radius. The mode spacing, the linewidth of WGMs, and the shift of resonant wavelength due to the change in radius and refractive index, were analyzed by numerical simulations. Preliminary results of unspecific binding of biomolecules are presented. The calculated shift in WGMs can be used for biomolecules detection. Y1 - 2012 U6 - http://dx.doi.org/10.1002/pssa.201100795 SN - 1862-6319 N1 - Special Issue: "Fundamentals and Applications of Diamond" VL - 209 IS - 9 SP - 1804 EP - 1810 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Huck, Christina A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Bifunktionaler Sensorchip für den Nachweis von Gelöstwasserstoff Y1 - 2011 SN - 978-3942710-53-4 U6 - http://dx.doi.org/10.5162/10dss2011/16.10 SP - 325 EP - 328 ER - TY - CHAP A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef ED - Abdelghani, Adnane ED - Schöning, Michael Josef T1 - Biopolymer-degradation monitoring by chip-­based impedance spectroscopy technique T2 - Nanoscale Science and Technology (NS&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012 Y1 - 2012 SP - 47 EP - 47 ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Wenmackers, Sylvia A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films JF - Diamond Electronics and Bioelectronics — Fundamentals to Applications III, edited by P. Bergonzo, [u.a.] Y1 - 2010 N1 - MRS Proceedings Volume 1203 paper 1203-J17-31 ; Mater. Res. Soc. Sympos. Proc. Vol 1203 (2010) ; Materials Research Society SP - 1 EP - 6 ER - TY - JOUR A1 - Karschuck, Tobias A1 - Poghossian, Arshak A1 - Ser, Joey A1 - Tsokolakyan, Astghik A1 - Achtsnicht, Stefan A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive model of enzyme-modified field-effect biosensors: Impact of enzyme coverage JF - Sensors and Actuators B: Chemical N2 - Electrolyte-insulator-semiconductor capacitors (EISCAP) belong to field-effect sensors having an attractive transducer architecture for constructing various biochemical sensors. In this study, a capacitive model of enzyme-modified EISCAPs has been developed and the impact of the surface coverage of immobilized enzymes on its capacitance-voltage and constant-capacitance characteristics was studied theoretically and experimentally. The used multicell arrangement enables a multiplexed electrochemical characterization of up to sixteen EISCAPs. Different enzyme coverages have been achieved by means of parallel electrical connection of bare and enzyme-covered single EISCAPs in diverse combinations. As predicted by the model, with increasing the enzyme coverage, both the shift of capacitance-voltage curves and the amplitude of the constant-capacitance signal increase, resulting in an enhancement of analyte sensitivity of the EISCAP biosensor. In addition, the capability of the multicell arrangement with multi-enzyme covered EISCAPs for sequentially detecting multianalytes (penicillin and urea) utilizing the enzymes penicillinase and urease has been experimentally demonstrated and discussed. KW - Field-effect biosensor KW - Capacitive model KW - Enzyme coverage KW - Multianalyte detection KW - Penicillin Y1 - 2024 U6 - http://dx.doi.org/10.1016/j.snb.2024.135530 SN - 0925-4005 (Print) SN - 1873-3077 (Online) N1 - Corresponding Author: Michael J. Schöning VL - 408 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reisert, Steffen A1 - Geissler, Hanno A1 - Flörke, Rudolf A1 - Weiler, Christian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Characterisation of aseptic sterilisation processes using an electronic nose JF - International journal of nanotechnology Y1 - 2013 SN - 1475-7435 (Print) 7141-8151 (Online) VL - Vol. 10 IS - No. 5-7 SP - 470 EP - 484 PB - Inderscience Enterprises CY - Genève ER - TY - JOUR A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Leinhos, Marcel A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Characterization of biodegradable polymers with capacitive field-effect sensors JF - Sensors and actuators B: Chemical N2 - In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance–voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor. KW - Impedance spectroscopy KW - C–V method KW - Real-time monitoring KW - Poly(d,l-lacticacid) KW - (Bio)degradation KW - Field-effect sensor Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2012.07.099 SN - 0925-4005 N1 - Part of special issue "Selected Papers from the 14th International Meeting on Chemical Sensors" VL - 187 SP - 2 EP - 7 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Zander, W. A1 - Schubert, J. A1 - Sukoyan, L. H. A1 - Begoyan, V. A1 - Buniatyan, V. V. A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Chemische Sensoren mit Bariumstrontiumtitanat als funktionelle Schicht zur Multiparameterdetektion T2 - 11. Dresdner Sensor-Symposium : 9.-11.12.2013 Y1 - 2013 SN - 978-3-9813484-5-3 SP - 368 EP - 372 ER - TY - JOUR A1 - Bäcker, Matthias A1 - Rakowski, D. A1 - Poghossian, Arshak A1 - Biselli, Manfred A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis JF - Journal of Biotechnology N2 - A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses. Y1 - 2013 U6 - http://dx.doi.org/10.1016/j.jbiotec.2012.03.014 SN - 0168-1656 VL - 163 IS - 4 SP - 371 EP - 376 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Combined amperometric/field-effect sensor for the detection of dissolved hydrogen JF - Sensors and actuators B: Chemical N2 - Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3% (v/v) with a slope of 198.4 ± 13.7 nA/% (v/v) and 14.9 ± 0.5 mV/% (v/v), respectively. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2012.10.050 SN - 0925-4005 N1 - Part of special issue "Selected Papers from the 14th International Meeting on Chemical Sensors" VL - 187 SP - 168 EP - 173 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bäcker, Matthias A1 - Beging, Stefan A1 - Biselli, Manfred A1 - Poghossian, Arshak A1 - Wang, J. A1 - Zang, Werner A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Concept for a solid-state multi-parameter sensor system for cell-culture monitoring JF - Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI Y1 - 2009 SN - 0013-4686 SP - 6107 EP - 6112 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Stütz, Evamaria A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Detection of toxic chromium species in water using cellbased sensor systems Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/P2.1.14 SP - 1364 EP - 1367 ER - TY - JOUR A1 - Warmer, Johannes A1 - Wagner, Patrick A1 - Schöning, Michael Josef A1 - Kaul, Peter T1 - Detection of triacetone triperoxide using temperature cycled metal-oxide semiconductor gas sensors JF - Physica status solidi (a) Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431882 SN - 1862-6319 VL - 212 IS - 6 SP - 1289 EP - 1298 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Dantism, Shahriar A1 - Takenaga, Shoko A1 - Wagner, Patrick A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Determination of the extracellular acidification of Escherichia coli K12 with a multi-​chamber-​based LAPS system JF - Physica status solidi (a) N2 - On-line monitoring of the metabolic activity of microorganisms involved in intermediate stages of biogas production plays an important role to avoid undesirable “down times” during the biogas production. In order to control this process, an on-chip differential measuring system based on the light-addressable potentiometric sensor (LAPS) principle combined with a 3D-printed multi-chamber structure has been realized. As a test microorganism, Escherichia coli K12 (E. coli K12) were used for cell-based measurements. Multi-chamber structures were developed to determine the metabolic activity of E. coli K12 in suspension for a different number of cells, responding to the addition of a constant or variable amount of glucose concentrations, enabling differential and simultaneous measurements. Y1 - 2016 U6 - http://dx.doi.org/10.1002/pssa.201533043 SN - 1862-6300 VL - 213 IS - 6 SP - 1479 EP - 1485 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Dantism, Shahriar A1 - Takenaga, Shoko A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Differential imaging of the metabolism of bacteria and eukaryotic cells based on light-addressable potentiometric sensors JF - Electrochimica Acta N2 - A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric sensor with an electrolyte/insulator/semiconductor (EIS) structure, which is able to monitor analyte concentrations of (bio-)chemical species in aqueous solutions in a spatially resolved way. Therefore, it is also an appropriate tool to record 2D-chemical images of concentration variations on the sensor surface. In the present work, two differential, LAPS-based measurement principles are introduced to determine the metabolic activity of Escherichia coli (E. coli) K12 and Chinese hamster ovary (CHO) cells as test microorganisms. Hereby, we focus on i) the determination of the extracellular acidification rate (ΔpH/min) after adding glucose solutions to the cell suspensions; and ii) recording the amplitude increase of the photocurrent (Iph) related to the produced acids from E. coli K12 bacteria and CHO cells on the sensor surface by 2D-chemical imaging. For this purpose, 3D-printed multi-chamber structures were developed and mounted on the planar sensor-chip surface to define four independent compartments, enabling differential measurements with varying cell concentrations. The differential concept allows eliminating unwanted drift effects and, with the four-chamber structures, measurements on the different cell concentrations were performed simultaneously, thus reducing also the overall measuring time. Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.electacta.2017.05.196 SN - 0013-4686 VL - 246 SP - 234 EP - 241 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Welden, Rene A1 - Scheja, Sabrina A1 - Schöning, Michael Josef A1 - Wagner, Patrick A1 - Wagner, Torsten T1 - Electrochemical Evaluation of Light‐Addressable Electrodes Based on TiO2 for the Integration in Lab‐on‐Chip Systems JF - physica status solidi a : applications and materials sciences N2 - In lab-on-chip systems, electrodes are important for the manipulation (e.g., cell stimulation, electrolysis) within such systems. An alternative to commonly used electrode structures can be a light-addressable electrode. Here, due to the photoelectric effect, the conducting area can be adjusted by modification of the illumination area which enables a flexible control of the electrode. In this work, titanium dioxide based light-addressable electrodes are fabricated by a sol–gel technique and a spin-coating process, to deposit a thin film on a fluorine-doped tin oxide glass. To characterize the fabricated electrodes, the thickness, and morphological structure are measured by a profilometer and a scanning electron microscope. For the electrochemical behavior, the dark current and the photocurrent are determined for various film thicknesses. For the spatial resolution behavior, the dependency of the photocurrent while changing the area of the illuminated area is studied. Furthermore, the addressing of single fluid compartments in a three-chamber system, which is added to the electrode, is demonstrated. Y1 - 2018 U6 - http://dx.doi.org/10.1002/pssa.201800150 SN - 1862-6319 VL - 215 IS - 15 SP - Article number 1800150 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Murib, M. S. A1 - Grinsven, B. van A1 - Grieten, L. A1 - Janssens, S. D. A1 - Vermeeren, V. A1 - Eersels, K. A1 - Broeders, J. A1 - Ameloot, M. A1 - Michiels, L. A1 - Ceuninck, W. De A1 - Haenen, K. A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Electronic monitoring of chemical DNA denaturation on nanocrystalline diamond electrodes with different molarities and flow rates JF - Physica Status Solidi (A). Vol. 210 (2013), iss. 5 Y1 - 2013 SN - 0031-8965 SP - 911 EP - 917 PB - Wiley-VCH CY - Berlin ER - TY - GEN A1 - Ingebrandt, Sven A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Engineering of functional interfaces / guest eds. Sven Ingebrandt ; Patrick Wagner ; Michael J. Schöning T2 - Physica Status Solidi (A) Y1 - 2013 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - Vol. 210 IS - Iss. 5 SP - 845 ER -