TY - JOUR A1 - Pöttgen, Philipp A1 - Ederer, Thorsten A1 - Altherr, Lena A1 - Lorenz, Ulf A1 - Pelz, Peter F. T1 - Examination and optimization of a heating circuit for energy-efficient buildings JF - Energy Technology N2 - The conference center darmstadtium in Darmstadt is a prominent example of energy efficient buildings. Its heating system consists of different source and consumer circuits connected by a Zortström reservoir. Our goal was to reduce the energy costs of the system as much as possible. Therefore, we analyzed its supply circuits. The first step towards optimization is a complete examination of the system: 1) Compilation of an object list for the system, 2) collection of the characteristic curves of the components, and 3) measurement of the load profiles of the heat and volume-flow demand. Instead of modifying the system manually and testing the solution by simulation, the second step was the creation of a global optimization program. The objective was to minimize the total energy costs for one year. We compare two different topologies and show opportunities for significant savings. KW - energy transfer KW - heating system KW - programming KW - system optimization KW - technical operations research Y1 - 2015 SN - 2194-4296 U6 - http://dx.doi.org/10.1002/ente.201500252 VL - 4 IS - 1 SP - 136 EP - 144 PB - WILEY-VCH Verlag CY - Weinheim ER - TY - JOUR A1 - Noureddine, Yacine A1 - Bitz, Andreas A1 - Ladd, Mark E. A1 - Thürling, Markus A1 - Ladd, Susanne C. A1 - Schaefers, Gregor A1 - Kraff, Oliver T1 - Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study JF - Magnetic Resonance Materials in Physics, Biology and Medicine Y1 - 2015 U6 - http://dx.doi.org/10.1007/s10334-015-0499-y SN - 1352-8661 VL - 28 IS - 6 SP - 577 EP - 590 PB - Springer CY - Berlin ER - TY - JOUR A1 - Altherr, Lena A1 - Ederer, Thorsten A1 - Lorenz, Ulf A1 - Pelz, Peter F. A1 - Pöttgen, Philipp ED - Lübbecke, Marco ED - Koster, Arie ED - Letmathe, Peter ED - Madlener, Reihard ED - Peis, Britta ED - Walther, Grit T1 - Experimental validation of an enhanced system synthesis approach JF - Operations Research Proceedings 2014 N2 - Planning the layout and operation of a technical system is a common task for an engineer. Typically, the workflow is divided into consecutive stages: First, the engineer designs the layout of the system, with the help of his experience or of heuristic methods. Secondly, he finds a control strategy which is often optimized by simulation. This usually results in a good operating of an unquestioned sys- tem topology. In contrast, we apply Operations Research (OR) methods to find a cost-optimal solution for both stages simultaneously via mixed integer program- ming (MILP). Technical Operations Research (TOR) allows one to find a provable global optimal solution within the model formulation. However, the modeling error due to the abstraction of physical reality remains unknown. We address this ubiq- uitous problem of OR methods by comparing our computational results with mea- surements in a test rig. For a practical test case we compute a topology and control strategy via MILP and verify that the objectives are met up to a deviation of 8.7%. Y1 - 2014 SN - 978-3-319-28695-2 U6 - http://dx.doi.org/10.1007/978-3-319-28697-6_1 PB - Springer CY - Basel ER - TY - JOUR A1 - Siepmann, Thomas A1 - Pfeiffer, J. A1 - Teichmann, W. T1 - Expertensystem zur spanenden Bearbeitung JF - Technische Mitteilungen Krupp (1988) Y1 - 1988 CY - Essen ER - TY - JOUR A1 - Siepmann, Thomas T1 - Expertensysteme in der rechnerintegrierten Produktion JF - Einführung in die CIM-Praxis : rechnerintegrierte Produktion / hrsg. von Gerhard Neipp ... Y1 - 1991 SN - 3-18-401098-8 SP - 187 EP - 198 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Siepmann, Thomas T1 - Exploitation Plan of the TELEflow Project Y1 - 1999 N1 - 4th Framework Programme Report CY - Brussels ER - TY - JOUR A1 - Reinhardt, T. A1 - Bitz, Andreas A1 - El Ouardi, A. A1 - Streckert, J. A1 - Sommer, A. A1 - Lerchl, A. A1 - Hansen, V. T1 - Exposure set-ups for in vivo experiments using radial waveguides JF - Radiation Protection Dosimetry Y1 - 2007 U6 - http://dx.doi.org/10.1093/rpd/ncm370 SN - 1742-3406 VL - 124 IS - 1 SP - 21 EP - 26 ER - TY - JOUR A1 - Schlamann, Marc A1 - Voigt, Melanie A. A1 - Maderwald, Stefan A1 - Bitz, Andreas A1 - Kraff, Oliver A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Forsting, Michael A1 - Wilhelm, Hans T1 - Exposure to high-field MRI does not affect cognitive function JF - Journal of Magnetic Resonance Imaging N2 - Purpose To assess potential cognitive deficits under the influence of static magnetic fields at various field strengths some studies already exist. These studies were not focused on attention as the most vulnerable cognitive function. Additionally, mostly no magnetic resonance imaging (MRI) sequences were performed. Materials and Methods In all, 25 right-handed men were enrolled in this study. All subjects underwent one MRI examination of 63 minutes at 1.5 T and one at 7 T within an interval of 10 to 30 days. The order of the examinations was randomized. Subjects were referred to six standardized neuropsychological tests strictly focused on attention immediately before and after each MRI examination. Differences in neuropsychological variables between the timepoints before and after each MRI examination were assessed and P-values were calculated Results Only six subtests revealed significant differences between pre- and post-MRI. In these tests the subjects achieved better results in post-MRI testing than in pre-MRI testing (P = 0.013–0.032). The other tests revealed no significant results. Conclusion The improvement in post-MRI testing is only explicable as a result of learning effects. MRI examinations, even in ultrahigh-field scanners, do not seem to have any persisting influence on the attention networks of human cognition immediately after exposure. Y1 - 2010 U6 - http://dx.doi.org/10.1002/jmri.22065 SN - 1522-2586 VL - 31 IS - 5 SP - 1061 EP - 1066 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Ferrein, Alexander A1 - Fritz, Christian A1 - Lakemeyer, Gerhard T1 - Extending DTGOLOG with Options / Ferrein, Alexander ; Fritz, Christian ; Lakemeyer, Gerhard JF - IJCAI-03, Proceedings of the Eighteenth International Joint Conference on Artificial Intelligence, Acapulco, Mexico, August 9-15, 2003 Y1 - 2003 SP - 1391 EP - 1393 ER - TY - JOUR A1 - Prume, Klaus A1 - Muralt, Paul A1 - Calame, Florian A1 - Schmitz-Kempen, Thorsten T1 - Extensive electromechanical characterization of PZT thin films for MEMS applications by electrical and mechanical excitation signals / Prume, Klaus ; Muralt, Paul ; Calame, Florian ; Schmitz-Kempen, Thorsten ; Tiedke, Stephan JF - Journal of Electroceramics. 19 (2007), H. 4 Y1 - 2007 SN - 1385-3449 SP - 407 EP - 411 ER - TY - JOUR A1 - Oßmann, Martin A1 - Hattrup, C. A1 - Broeck, H. W. van der T1 - Fast estimation techniques for digital control of resonant converters / Hattrup, C.; van der Broeck, H.W.; Ossmann, M.; JF - IEEE Transaction on Power Electronics. 18 (2003), H. 1 Y1 - 2003 SN - 0885-8993 N1 - Part 2 SP - 365 EP - 372 ER - TY - JOUR A1 - Krause, Gregor A1 - Rodriguez, Jackson A1 - Stopic, Srecko A1 - Friedrich, Bernd T1 - Feasibility assessment of electrocoagulation towards a new sustainable wastewater treatment / Rodriguez, Jackson ; Stopic, Srecko ; Krause Gregor ; Friedrich, Bernd JF - Environmental Science and Pollution Research. 14 (2007), H. 7 Y1 - 2007 SN - 0944-1344 SP - 477 EP - 482 ER - TY - JOUR A1 - Maas, Marnix C. A1 - Vos, Eline K. A1 - Lagemaat, Miriam W. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Kobus, Thiele A1 - Kraff, Oliver A1 - Maderwald, Stefan A1 - Ladd, Mark E. A1 - Scheenen, Tom W. J. T1 - Feasibility of T₂-weighted turbo spin echo imaging of the human prostate at 7 tesla JF - Magnetic Resonance in Medicine N2 - Purpose To demonstrate that high quality T₂-weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only. Methods Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B₀ and radiofrequency shimming and localized flip angle calibration. T₁ and T₂ relaxation times were measured and used to define the T2w-TSE protocol. T2w imaging was performed using a TSE sequence (pulse repetition time/echo time 3000–3640/71 ms) with prolonged excitation and refocusing pulses to reduce specific absorption rate. Results High quality T2w TSE imaging was performed in less than 2 min in all subjects. Tumors of patients with gold-standard tumor localization (MR-guided biopsy or prostatectomy) were well visualized on 7 T imaging (n = 3). The number of consecutive slices achievable within a 10-g averaged specific absorption rate limit of 10 W/kg was ≥28 in all subjects, sufficient for full prostate coverage with 3-mm slices in at least one direction. Conclusion High quality T2w TSE prostate imaging can be performed routinely and within specific absorption rate limits at 7 T with an external transceive body array. Y1 - 2014 U6 - http://dx.doi.org/10.1002/mrm.24818 SN - 1522-2594 VL - 71 IS - 5 SP - 1711 EP - 1719 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Lepers, Heinrich T1 - Fehler bei der Systemanalyse aus stochastisch gestörten Sprungantworten JF - Regelungstechnik und Prozeß-Datenverarbeitung N2 - Es wird von Gleichungen ausgegangen, mit denen die Modellkoeffizienten von Regelstrecken mit Ausgleich aus der gemessenen Sprungantwort ermittelt werden können. Die Übertragungsfunktion der Regelstrecke hat einen konstanten Zähler und ein Nennerpolynom. Unter der Annahme, daß die ideale und exakte Sprungantwort des Systems durch ein stochastisches Signal gestört wird, wird untersucht, wie die Fehler der ermittelten Modellkoeffizienten von Kennwerten des Störsignals und von der Meßzeit für die Sprungantwort abhängen. Durch eine Simulation auf dem Digitalrechner wurden die Ergebnisse kontrolliert. Es zeigt sich, daß durch eine Filterung der gestörten Sprungantwort über einen Tiefpaß keine Verbesserung der Analyseergebnisse erreicht werden kann, da das Identifizierungsverfahren eine glättende Eigenschaft hat. Y1 - 1973 U6 - http://dx.doi.org/10.1524/auto.1973.21.112.229 SN - 0034-3226 VL - 21 IS - 7 SP - 229 EP - 233 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Heuermann, Holger T1 - Fehlerkorrigierte Mehrtormessungen für frequenzumsetzende Komponenten mit NonLin-S JF - HF-Report : Hochfrequenztechnik, Optoelektronik, Mikrowellentechnik, Kommunikationstechnik. 22 (2008), H. 4 Y1 - 2008 SN - 1431-827X SP - 39 EP - 44 ER - TY - JOUR A1 - Prume, Klaus A1 - Franken, Klaus A1 - Maier, Horst R. A1 - Waser, Rainer T1 - Finite-Element Analysis of Ceramic Multilayer Capacitors: Failure Probability Caused by Wave Soldering and Bending Loads / Franken, Klaus ; Maier, Horst R. ; Prume, Klaus ; Waser, Rainer JF - Journal of the American Ceramic Society. 83 (2000), H. 6 Y1 - 2000 SN - 0002-7820 SP - 1433 EP - 1440 ER - TY - JOUR A1 - Prume, Klaus A1 - Waser, Rainer A1 - Franken, Klaus A1 - Maier, Horst R. T1 - Finite-Element Analysis of Ceramic Multilayer Capacitors: Modeling and Electrical Impedance Spectroscopy for a Nondestructive Failure Test / Prume, Klaus ; Waser, Rainer ; Franken, Klaus ; Maier, Horst R. ; JF - Journal of the American Ceramic Society. 83 (2000), H. 5 Y1 - 2000 SN - 0002-7820 SP - 1153 EP - 1159 ER - TY - JOUR A1 - Prume, Klaus A1 - Waser, Rainer T1 - Finite-element simulation of coupled characteristics of ceramic multilayer capacitors under transient electrical loading / Prume, Klaus ; Waser, Rainer JF - Proceedings of the 2000 12th IEEE International Symposium on Applications of Ferroelectrics. Vol. 2 Y1 - 2000 N1 - ISAF 2000. Proceedings of the 2000 12th IEEE International Symposium on Applications of Ferroelectrics SP - 675 EP - 678 ER - TY - JOUR A1 - Umutlu, L. A1 - Maderwald, S. A1 - Kinner, S. A1 - Kraff, O. A1 - Bitz, Andreas A1 - Orzada, S. A1 - Johst, S. A1 - Wrede, K. A1 - Forsting, M. A1 - Ladd, M. E. A1 - Lauenstein, T. C. A1 - Quick, H. H. T1 - First-pass contrast-enhanced renal MRA at 7 Tesla: initial results JF - European Radiology Y1 - 2013 U6 - http://dx.doi.org/10.1007/s00330-012-2666-0 SN - 1432-1084 VL - 23 IS - 4 SP - 1059 EP - 1066 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Geittner, P. A1 - Mayr, W. A1 - Opitz, J. F. A. T1 - Folientechnologie für zukünftige keramische Vielschichtkondensatoren. Geittner, P.; Hagemann, H.-J.;Mayr, W. ; Opitz, J.F.A. ; Schmidl, B.; Warnier, J. JF - Ceramic forum international : cfi ; Berichte der Deutschen Keramischen Gesellschaft. 8 (1993), H. 5 Y1 - 1993 SN - 0173-9913 N1 - weitere ISSN 0196-6219 SP - 5 EP - 15 ER -