TY - JOUR A1 - Rietsch, Stefan H. G. A1 - Pfaffenrot, Viktor A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Brunheim, Sascha A1 - Lazik-Palm, Andrea A1 - Theysohn, Jens M. A1 - Ladd, Mark E. A1 - Quick, Harald H. A1 - Kraff, Oliver T1 - An 8-channel transceiver 7-channel receive RF coil setup for high SNR ultrahigh-field MRI of the shoulder at 7T JF - Medical Physics Y1 - 2017 U6 - http://dx.doi.org/10.1002/mp.12612 SN - 0094-2405 IS - Article in press PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Faßbender, Heinz A1 - Vogler, Heiko A1 - Wedel, Andrea T1 - An abstract machine for the E-Unification with macro tree transducer JF - 7th International Workshop on Unification : 13. 06. - 14. 06. 93 / Franz Baader ... (eds.). [Boston University, Boston, USA] Y1 - 1993 ER - TY - JOUR A1 - Schuba, Marko A1 - Reichl, Peter T1 - An Analysis of Retransmission Strategies for Reliable Multicast Protocols / Schuba, M. ; Reichl, P. JF - Performance of information and communication systems : IFIP TC 6,WG 6.3 Seventh International Conference on Performance of Information and Communication Systems (PICS '98), 25 - 28 May, Lund, Sweden / ed. by Ulf Körner ... Y1 - 1998 SN - 0-412-83730-7 SP - 1 EP - 12 PB - Chapman Hall CY - London ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Kruszona, Stefan A1 - Orzada, Stephan A1 - Schaefer, Lena C. A1 - Theysohn, Jens M. A1 - Maderwald, Stefan A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel phased array RF coil for spine MR imaging at 7 T JF - Investigative Radiology Y1 - 2009 U6 - http://dx.doi.org/10.1097/RLI.0b013e3181b24ab7 SN - 1536-0210 VL - 44 IS - 11 SP - 734 EP - 740 PB - Lippincott Williams & Wilkins ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Dammann, Philipp A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T JF - Medical Physics N2 - Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique. Y1 - 2010 U6 - http://dx.doi.org/10.1118/1.3517176 SN - 2473-4209 VL - 37 IS - 12 SP - 6368 EP - 6376 PB - Wiley CY - Hoboken, NJ ER - TY - JOUR A1 - Faßbender, Heinz A1 - Bühler, Gerhard T1 - An experimental command and control information system based on Enterprise Java bean technology JF - Proceedings of the 7th International Command and Control Research and Technology Symposium, September 2002, Quebec City, Kanada Y1 - 2002 SP - 1 EP - 8 ER - TY - JOUR A1 - Faßbender, Heinz A1 - Vogler, Heiko T1 - An implementation of syntax directed functional programming on nested-stack machines JF - Formal Aspects of Computing. 4 (1992), H. 4 Y1 - 1992 SN - 0934-5043 SP - 341 EP - 375 ER - TY - JOUR A1 - Kowalewski, Paul A1 - Bragard, Michael A1 - Hüning, Felix A1 - De Doncker, Rik W. T1 - An inexpensive Wiegand-sensor-based rotary encoder without rotating magnets for use in electrical drives JF - IEEE Transactions on Instrumentation and Measurement N2 - This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth. KW - Rotary encoder KW - Wiegand sensor Y1 - 2023 U6 - http://dx.doi.org/10.1109/TIM.2023.3326166 SN - 0018-9456 (Print) SN - 1557-9662 (Online) N1 - Early Access SP - 10 Seiten PB - IEEE ER - TY - JOUR A1 - Zastrow, Udo A1 - Panagiotopoulos, P. D. T1 - An integral "Equation" approach to the unilateral contact problem JF - ZAMM - Zeitschrift für angewandte Mathematik und Mechanik. 59 (1979), H. 8 Y1 - 1979 SN - 1521-4001 SP - 392 EP - 393 ER - TY - JOUR A1 - Hartung, Frank A1 - Kumwilaisak, W. T1 - An intraframe error concealment: nonlinear pattern alignment and directional interpolation / Kumwilaisak, W. ; Hartung, F. JF - Conference on Image Processing, 2004. ICIP '04. 2004 International / Vol. 2 . Y1 - 2004 N1 - http://dx.doi.org/10.1109/ICIP.2004.1419426 SP - 825 EP - 828 ER - TY - JOUR A1 - Schuba, Marko T1 - Analyse der Antwortzeit von zuverlässigen Multicast-Protokollen im Internet JF - Multicast - Protokolle und Anwendungen : 20. - 21. Mai 1999, Braunschweig; 1. GI-Workshop / [Workshop-Leitung: Martina Zitterbart ...] Y1 - 1999 SP - 1 EP - 14 CY - Braunschweig ER - TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Johst, Sören A1 - Gratz, Marcel A1 - Völker, Maximilian N. A1 - Kraff, Oliver A1 - Abuelhaija, Ashraf A1 - Fiedler, Thomas M. A1 - Solbach, Klaus A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - Analysis of an integrated 8-Channel Tx/Rx body array for use as a body coil in 7-Tesla MRI JF - Frontiers in Physics Y1 - 2017 U6 - http://dx.doi.org/10.3389/fphy.2017.00017 SN - 2296-424X N1 - Article number 17 VL - 5 IS - Jun ER - TY - JOUR A1 - Schuba, Marko T1 - Analysis of Feedback Error Control Schemes for Block Based Video Communication / Meggers, Jens ; Schuba, Marko Y1 - 1999 ER - TY - JOUR A1 - Prume, Klaus A1 - Peter, F. A1 - Rüdiger, A. A1 - Dittmann, R. T1 - Analysis of shape effects on the piezoresponse in ferroelectric nanograins with and without adsorbates / Peter, F. ; Rüdiger, A. ; Dittmann, R. ; Waser, R. ; Szot, K. ; Reichenberg, B. ; Prume, K. ; JF - Applied Physics Letters . 87 (2005), H. 8 Y1 - 2005 SN - 0003-6951 SP - 082901 EP - 082901-3 ER - TY - JOUR A1 - Zastrow, Udo T1 - Anisotrope Scheiben mit gemischten Randbedingungen JF - ZAMM - Zeitschrift für Angewandte Mathematik und Mechanik. 59 (1979), H. 5 Y1 - 1979 SN - 1521-4001 SP - T218 EP - T219 ER - TY - JOUR A1 - Lepers, Heinrich A1 - Jäger, G. A1 - Pütter, L. T1 - Anwendung eines Prozessmodells zur Regelung der Produktqualität bei der Zementklinker-Herstellung / Jaeger, G. ; Lepers, H. Puetter, L. [u.a.] JF - VDI-Berichte (1977) Y1 - 1977 SP - 87 EP - 93 ER - TY - JOUR A1 - Ellerweg, Roland A1 - Ritz, Thomas A1 - Schuhmann, Stefan T1 - Anwendungsentwicklung für iPhone und Windows Mobile : ein bisschen von allem JF - iX : Magazin für professionelle Informationstechnik Y1 - 2009 SN - 0935-9680 (Print) SN - 1612-1392 (Online) IS - 3 SP - 132 EP - 135 ER - TY - JOUR A1 - Faßbender, Heinz A1 - Bühler, Gerhard T1 - Applying Ada, Java and CORBA for making a command and control information system platform independent JF - Proceedings : (SIGAda '99) ; October 17 - 21, 1999 ; Crowne Plaza, Redondo Beach & Marine Hotel, Redondo Beach, CA, USA / ACM SIGAda Annual International Conference Y1 - 1999 SN - 1-58113-127-5 N1 - (Ada letters ; 19,3) SP - 83 EP - 88 PB - ACM CY - New York, NY ER - TY - JOUR A1 - Ferrein, Alexander A1 - Dylla, Frank A1 - Lakemeyer, Gerhard A1 - Murray, Jan T1 - Approaching a formal soccer theory from behaviour specifications in robotic soccer / Dylla, Frank ; Ferrein, Alexander ; Lakemeyer, Gerhard ; Murray, Jan ; Obst, Oliver ; Röfer, Thomas ; Schiffer, Stefan ; Stolzenburg, Frieder ; Visser, Ubbo ; Wagner, Tho JF - Computers in sport / editors: P Dabnichki Y1 - 2008 SN - 978-1-8456-4064-4 SP - 161 EP - 185 PB - WIT Press CY - Southampton ER - TY - JOUR A1 - Mayer, Claudia T1 - Aspekte der Wiedervereinigung in der aktuellen deutschen Literatur. JF - Forum Deutsch : Informationen, Meinungen, Materialien und Tips für kanadische Deutschlehrer / Ständige Konferenz kanadischer Deutschlehrer (1991) Y1 - 1991 SP - 16 EP - 22 ER -