TY - CHAP A1 - Tymecki, Lukasz A1 - Glab, Stanislaw A1 - Koncki, Robert T1 - Miniaturized, planar ion-selective electrodes fabricated by means of thick-film technology N2 - Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thin- and thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and allows precise pattern control. Moreover, this is a highly economic technology, saving large amounts of the used inks. In the course of repetitions of the film-deposition procedure there is no waste of material due to additivity of this thick-film technology. Finally, the thick films can be easily and quickly deposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodes based on ionophores as well as crystalline ion-selective materials dedicated for potentiometric measurements are demonstrated. Analytical parameters of these sensors are comparable with those reported for conventional potentiometric electrodes. All mentioned thick-film strip electrodes have been totally fabricated in only one, fully automated thickfilm technology, without any additional manual, chemical or electrochemical steps. In all cases simple, inexpensive, commercially available materials, i.e. flexible, plastic substrates and easily cured polymer-based pastes were used. KW - Biosensor KW - Potentiometry KW - thick-film technology KW - screen-printing KW - ion-selective electrodes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1506 ER - TY - CHAP A1 - Chaiyboun, Ali A1 - Traute, Rüdiger A1 - Kiesewetter, Olaf A1 - Ahlers, Simon A1 - Müller, Gerhard A1 - Doll, Theodor T1 - Modular analytical multicomponent analysis in gas sensor arrays N2 - A multi-sensor system is a chemical sensor system which quantitatively and qualitatively records gases with a combination of cross-sensitive gas sensor arrays and pattern recognition software. This paper addresses the issue of data analysis for identification of gases in a gas sensor array. We introduce a software tool for gas sensor array configuration and simulation. It concerns thereby about a modular software package for the acquisition of data of different sensors. A signal evaluation algorithm referred to as matrix method was used specifically for the software tool. This matrix method computes the gas concentrations from the signals of a sensor array. The software tool was used for the simulation of an array of five sensors to determine gas concentration of CH4, NH3, H2, CO and C2H5OH. The results of the present simulated sensor array indicate that the software tool is capable of the following: (a) identify a gas independently of its concentration; (b) estimate the concentration of the gas, even if the system was not previously exposed to this concentration; (c) tell when a gas concentration exceeds a certain value. A gas sensor data base was build for the configuration of the software. With the data base one can create, generate and manage scenarios and source files for the simulation. With the gas sensor data base and the simulation software an on-line Web-based version was developed, with which the user can configure and simulate sensor arrays on-line. KW - Biosensor KW - Main sensitivity KW - cross sensitivity KW - matrix method KW - gas sensor array KW - modelling Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1358 ER - TY - CHAP A1 - Bukhari, Syed Faisal Ahmed A1 - Yang, Wuqiang T1 - Multi-interface level sensors and new development in monitoring and control of oil separators N2 - In the oil industry, huge saving may be made if suitable multi-interface level measurement systems are employed for effectively monitoring crude oil separators and efficient control of their operation. A number of techniques, e.g. externally mounted displacers, differential pressure transmitters and capacitance rod devices, have been developed to measure the separation process with gas, oil, water and other components. Because of the unavailability of suitable multi-interface level measurement systems, oil separators are currently operated by the trial-and-error approach. In this paper some conventional techniques, which have been used for level measurement in industry, and new development are discussed. KW - Biosensor KW - Level sensor KW - multi-interface measurement KW - electrical capacitance tomography KW - ECT Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1498 ER - TY - CHAP A1 - Näther, Niko A1 - Poghossian, Arshak A1 - Platen, J. A1 - Yoshinobu, T. A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing of both physical and (bio-)chemical quantities using the same transducer principle T2 - Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ... Y1 - 2006 SP - 172 EP - 181 CY - Warsaw ER - TY - CHAP A1 - Pfaff, Raphael A1 - Vinsonneau, B. A1 - Burnham, K. J. T1 - Multiple models for nonlinear systems T2 - Proceedings / Eigteenth International Conference on Systems Engineering : ICSE 2006 : 5 - 7 September 2006 ; [held at Coventry University, UK] Y1 - 2006 SN - 1-84600-013-0 SP - 347 EP - 352 ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus A1 - Welters, T. T1 - Neue Möglichkeiten der Klebstoffverarbeitung durch geschwindigkeitsproportionalen Handauftrag T2 - Adhesive bonding and hybrid bonding in body-in-white shop and assembly : proceedings, 25/26 April 2006, Bad Nauheim/Frankfurt Y1 - 2006 SP - 81 PB - Technik & Kommunikation Verl.-GmbH CY - Berlin ER - TY - CHAP A1 - Arida, Hassan A. A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations N2 - A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors. KW - Biosensor KW - Heavy metal detection KW - thin-film microsensors KW - organic PVC membranes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1545 ER - TY - CHAP A1 - Kowalski, Julia T1 - Numerical Debris Flow Simulation T2 - Schweizer Numerik Kolloquium : Book of Abstracts 12. April 2006 Y1 - 2006 ER - TY - CHAP A1 - Deterding, A. A1 - Tippkötter, Nils A1 - Ulber, R. ED - Beckmann, Dieter T1 - Online-Essigsäureanalytik in Fermentationsbrühen mittels Fließdiffusionstechnik (FDT) T2 - Technische Systeme für Biotechnologie und Umwelt : 13. Heiligenstädter Kolloquium, Heilbad Heiligenstadt, 25.09. - 27.09.2006 Y1 - 2006 SN - 978-3-00-018621-9 SP - 273 EP - 280 CY - Heiligenstadt ER - TY - CHAP A1 - Schuh, G. A1 - Gottschalk, S. A1 - Höhne, Tim A1 - Cloots, M. ED - Wenzel, Sigrid T1 - Parametrierung einer Schlupfregelung in der simulativen Produktionsplanung T2 - Simulation in Produktion und Logistik 2006 : Tagungsband zur 12. Fachtagung, Kassel, 26. - 27. September 2006 Y1 - 2006 SN - 3-936150-48-6 N1 - ASIM-Mitteilung ; 104 SP - 233 EP - 243 ER - TY - CHAP A1 - Wellmann, Judith T1 - Perspektiven eines Bauingenieurs im konstruktiven Ingenieurbau N2 - In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 7-12 Die Berufsperspektiven im konstruktiven Ingenieurbau werden trotz sinkendem Bedarf an Statikern positiv bewertet. KW - Ingenieurbau KW - Konstruktiver Ingenieurbau KW - Statiker KW - Berufsperspektiven Y1 - 2006 ER - TY - CHAP A1 - Pijanowska, Dorota G. A1 - Remiszewska, Elzbieta T1 - pH-based detection of phenylalnine by potentiometric and colorimetric methods N2 - In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration. KW - Biosensor KW - Phenylalanine determination KW - enzymatic methods KW - pH-based biosensing Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1536 ER - TY - CHAP A1 - Himmerich, Jörg T1 - Pipeline Integrity Management System - Probabilistische Bewertung von Bauwerken am Beispiel von Hochdruckleitungen N2 - In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 21-22. Zusammenfassung des Vortrags. KW - Hochdruckleitung KW - PIMS KW - Pipeline Integrity Management System Y1 - 2006 ER - TY - CHAP A1 - Gobbelé, Dirk T1 - Planung der Umbaumaßnahme Hauptbahnhof Aachen N2 - In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 13-15. Bericht über die infrastrukturellen Maßnahmen zum Umbau des Hauptbahnhofs Aachen. KW - Bauplanung KW - Umbauplanung KW - Verkehrsbau KW - Hauptbahnhof Aachen Y1 - 2006 ER - TY - CHAP A1 - Kretschmann, Lars T1 - Planung und Bauleitung Buschtunnel Aachen N2 - In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 16-17 Der Umbau des Aachener Buschtunnels im Rahmen des europäischen Hochgeschwindigkeitsschienennetzes wird im sogenannten "Neuen Österreichischen Tunnelbauverfahren (NOeT)", also ein Ausbau in Kalotte, Strosse und Sohle durchgeführt. KW - Bauplanung KW - Bauführung KW - Bauleitung KW - Tunnelbau Y1 - 2006 ER - TY - CHAP A1 - Augenstein, Eckardt A1 - Herbergs, S. A1 - Kuperjans, Isabel T1 - Planung und Bewertung der Gebäudeenergieversorgung mit TOP-Energy T2 - Heizungs- und Raumlufttechnik : 1. Fachtagung Leonberg, 31. Januar bis 1. Februar 2006. - (VDI-Berichte ; Nr. 1921) Y1 - 2006 SN - 3-18-091921-3 N1 - Posterbeitrag SP - 57 EP - 60 PB - VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Vedral, Andreas A1 - Wollert, Jörg T1 - Praktische Untersuchungen zum zeitlichen Übertragungs- und Bündelfehlerverhalten der IEEE 802.15.4 T2 - ZigBee & Co. - drahtlose Nahbereichsnetzwerke : 04. April 2006, München Y1 - 2006 PB - Design&Elektronik CY - Poing ER - TY - CHAP A1 - Vredal, Andreas A1 - Wollert, Jörg T1 - Praktische Untersuchungen zur Reduzierung der Restfehlerrate von Funksystemen T2 - Wireless Automation : Chancen, Lösungen, Risiken ; Tagung Darmstadt, 8. und 9. Mai 2006. (VDI-Berichte ; 1939) Y1 - 2006 SN - 3-18-091939-6 SP - 135 EP - 146 PB - VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Preface of the Special Issue of I3S 2005 in Jülich (Germany) N2 - International Symposium on Sensor Science, I3S 2005 <3; 2005; Juelich, Germany> In: Sensors 2006, 6, 260-261 ISSN 1424-8220 KW - Biosensor KW - I3S 2005 KW - International Symposium on Sensor Science Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1365 ER - TY - CHAP A1 - Staat, Manfred T1 - Problems and chances for probabilistic fracture mechanics in the analysis of steel pressure boundary reliability. - Überarb. Ausg. N2 - In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demon­strated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several addi­tional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings. KW - Bruchmechanik KW - probabilistic fracture mechanics KW - PFM Y1 - 2006 ER -