TY - JOUR A1 - Feldmann, Markus A1 - Döring, Bernd A1 - Kuhnhenne, Markus A1 - Sedlacek, Gerhard T1 - Zum Thema “Nachhaltigkeit” in der Stahlbauindustrie JF - Stahlbau Y1 - 2008 SN - 0038-9145 N1 - Printausg. in der Bibliothek Bayernallee vorhanden: 13 Z 181 VL - Vol. 77 IS - Iss. 10 SP - 713 EP - 720 ER - TY - RPRT A1 - Kesti, Jyrki A1 - Mononen, Tarmo A1 - Lautso, Petteri A1 - Döring, Bernd A1 - Reger, Vitali A1 - Holopainen, R. A1 - Jung, N. A1 - Shemeikka, J. A1 - Nieminen, J. A1 - Reda, F. A1 - Lawson, Mark A1 - Botti, Andrea A1 - Hall, R. A1 - Zold, A. A1 - Buday, T. T1 - Zero energy solutions for multifunctional steel intensive commercial buildings (ZEMUSIC) - EUR 27627 N2 - The broad commercial objective of this project was the sustainable value creation in steel building technology by addressing the ways in which significant energy reductions can be made in the operation phase of multi-storey commercial buildings. A review on energy efficient commercial buildings in Europe has been carried out consisting of several case studies from different countries. The project included development of zero-energy concepts for reducing energy demand as well as concepts for heating, cooling and ventilation systems by utilising renewable energy sources in three different climates. Also alternative structural frame solutions were developed and analyzed in respect of structural and MEP (mechanical, electrical and plumbing solutions) features. An innovative long span floor system with integrated MEP routings promises a cost effective alternative for sophisticated ventilation distribution and radiant heating and cooling systems, allowing for high energy efficiency and high quality interior climate. The report includes also review of best architectural practices for integrated renewable energy solutions including different design strategies for building facades of zero energy buildings. Interesting results and design basis are also presented for steel energy pile concept, where structural foundation piles are utilized for ground energy harvesting. Life cycle cost calculations for near zero energy office building based on developed technologies show that a near zero energy construction is also profitable. The results and work methods of the project have been summarized in the form of design guidance that offers designers the knowledge gained in a form that can be easily understood. KW - steel KW - iron and steel industry KW - resistance of materials KW - materials technology KW - metal structure KW - research project KW - building industry KW - building materials KW - renewable energy KW - designs and models KW - research report KW - guide Y1 - 2015 SN - 978-92-79-54071-4 U6 - http://dx.doi.org/10.2777/111520 SN - 1831-9424 N1 - Enthalten: Appendix Design Guide: Deliverable Report WP6.4 Design Guide for steel intensive nearly zero office buildings (83 Seiten) PB - Publications Office of the European Union CY - Luxembourg ER - TY - PAT A1 - Döring, Bernd A1 - Hechler, Oliver T1 - Verfahren und Vorrichtung zu Temperierung von Bauteilen : Offenlegungsschrift T1 - Device for tempering of component parts in which continuous gap exists between outer contour of pipe element and cavity contour of mineral component has arrangement whereby gap is filled completely with cellular material Y1 - 2003 PB - Deutsches Patent- und Markenamt CY - München ER - TY - CHAP A1 - Döring, Bernd A1 - Ziller, Claudia A1 - Hortmanns, M. T1 - Ventilation of double facades by external dynamic wind pressure T2 - 11th International Conference on Wind Engineering. 1 Y1 - 2003 SP - 721 EP - 730 PB - The Wind Science and Engineering Research Center CY - Lubbock, Tex. ER - TY - CHAP A1 - Blanke, Tobias A1 - Schmidt, Katharina S. A1 - Göttsche, Joachim A1 - Döring, Bernd A1 - Frisch, Jérôme A1 - van Treeck, Christoph ED - Weidlich, Anke ED - Neumann, Dirk ED - Gust, Gunther ED - Staudt, Philipp ED - Schäfer, Mirko T1 - Time series aggregation for energy system design: review and extension of modelling seasonal storages T2 - Energy Informatics N2 - Using optimization to design a renewable energy system has become a computationally demanding task as the high temporal fluctuations of demand and supply arise within the considered time series. The aggregation of typical operation periods has become a popular method to reduce effort. These operation periods are modelled independently and cannot interact in most cases. Consequently, seasonal storage is not reproducible. This inability can lead to a significant error, especially for energy systems with a high share of fluctuating renewable energy. The previous paper, “Time series aggregation for energy system design: Modeling seasonal storage”, has developed a seasonal storage model to address this issue. Simultaneously, the paper “Optimal design of multi-energy systems with seasonal storage” has developed a different approach. This paper aims to review these models and extend the first model. The extension is a mathematical reformulation to decrease the number of variables and constraints. Furthermore, it aims to reduce the calculation time while achieving the same results. KW - Energy system KW - Renewable energy KW - Mixed integer linear programming (MILP) KW - Typical periods KW - Time-series aggregation Y1 - 2022 U6 - http://dx.doi.org/10.1186/s42162-022-00208-5 SN - 2520-8942 N1 - Proceedings of the 11th DACH+ Conference on Energy Informatics, 15-16 September 2022, Freiburg, Germany. VL - 5 IS - 1, Article number: 17 SP - 1 EP - 14 PB - Springer Nature ER - TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - http://dx.doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - JOUR A1 - Döring, Bernd A1 - Hechler, O. A1 - Weber, F. A1 - Sedlacek, Gerhard T1 - Thermische Aktivierung von Fertigteildecken JF - HLH Lüftung/Klima, Heizung/Sanitär, Gebäudetechnik Y1 - 2004 SN - 1436-5103 N1 - Printausg. in der Bibliothek Bayernallee vorhanden: 13 Z 739 VL - Jg. 55 IS - Nr. 5 SP - 24 EP - 35 ER - TY - JOUR A1 - Döring, Bernd A1 - Kendrick, C. A1 - Lawson, R. M. T1 - Thermal capacity of composite floor slabs JF - Energy and buildings Y1 - 2013 SN - 1872-6178 (E-Journal); 0378-7788 (Print) VL - Vol. 67 SP - 531 EP - 539 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Döring, Bernd A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Feldmann, Markus A1 - Kesti, Jyrki A1 - Lawson, Mark A1 - Botti, Andrea T1 - Steel solutions for enabling zero-energy buildings JF - Steel Construction - Design and Research Y1 - 2015 U6 - http://dx.doi.org/10.1002/stco.201510029 SN - 1867-0539 N1 - The 13th Nordic Steel Construction Conference, Tampere, 2015 (NSCC-2015) VL - 8 IS - 3 SP - 194 EP - 200 PB - Ernst & Sohn CY - Berlin ER - TY - RPRT A1 - Conan, Yulian A1 - D'Haeyer, R. A1 - Béguin, P. A1 - Döring, Bernd A1 - Kuhnhenne, Markus A1 - Bayo, E. T1 - Steel in low-rise building : a symbiosis of cold formed sections and light rolled profiles : final report. Contract-No. 7215-PP/070. EUR 22080 en Y1 - 2006 SN - 92-79-02082-X PB - Office for Official Publications of the European Communities CY - Luxembourg ER - TY - PAT A1 - Döring, Bernd A1 - Feldmann, Markus A1 - Kuhnhenne, Markus T1 - Schallschutz-Wandaufbau für ein Bauwerk oder ein Bauteil in Metallleichtbauweise, das mit Solarzellen bestückt ist : Offenlegungsschrift T1 - Sound protection-wall structure i.e. sound protection-roof structure, for building e.g. industrial building, provided with photovoltaic solar modules, has metallic layers, insulation layer and energy storage arranged within structure Y1 - 2013 PB - Deutsches Patent- und Markenamt CY - München ER - TY - RPRT A1 - Lawson, R.M. A1 - Baddoo, N.R. A1 - Vanier, G. A1 - Döring, Bernd A1 - Kuhnhenne, M. A1 - Nieminen, J. A1 - Beguin, P. A1 - Herbin, S. A1 - Caroli, G. A1 - Adetunji, I. A1 - Kozlowski, A. T1 - Renovation of buildings using steel technologies (Robust) - EUR 25335 N2 - Robust addresses the renovation and improvement of existing residential, industrial and commercial buildings using steel-based technologies, focusing on techniques such as over-cladding, over-roofing and roof-top extensions. Steel-intensive renovation techniques currently on the market were reviewed. Performance criteria were developed for over-cladding systems meeting current regulatory standards, with guidelines on how to achieve appropriate levels of air-tightness. KW - iron and steel industry KW - steel KW - materials technology KW - building materials KW - metal structure KW - building safety KW - testing KW - industrial research Y1 - 2013 SN - 978-92-79-24950-1 U6 - http://dx.doi.org/10.2777/97860 SN - 1831-9424 PB - Publications Office of the European Union CY - Luxembourg ER - TY - JOUR A1 - Kuck, Herbert A1 - Döring, Bernd T1 - Regenerative Energien in Landesbauten : Land NRW unterstützt Einsatz erneuerbarer Energien 1997 mit 15 Mio. DM JF - Die Bauverwaltung mit Bauamt und Gemeindebau Y1 - 1997 SN - 0005-6847 VL - Bd. 70 IS - H. 8 SP - 384 EP - 386 ER - TY - JOUR A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Hachul, Helmut A1 - Döring, Bernd A1 - Blanke, Tobias A1 - Göttsche, Joachim T1 - Plusenergiegebäude 2.0 in Stahlleichtbauweise JF - Stahlbau Y1 - 2019 U6 - http://dx.doi.org/10.1002/stab.201900034 SN - 1437-1049 (E-journal), 0038-9145 (print) VL - 88 IS - 6 SP - 522 EP - 528 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Döring, Bernd A1 - Feldmann, Markus A1 - Kuhnhenne, Markus A1 - Müller, Dirk T1 - Phasenwechselmaterial im Metallleichtbau zur Optimierung von Energieeffizienz und sommerlicher Raumtemperatur JF - Stahlbau Y1 - 2011 SN - 1437-1049 (E-Journal); 0038-9145 (Print) VL - Vol. 80 IS - Iss. 9 SP - 666 EP - 672 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Reger, V. A1 - Döring, Bernd A1 - Kuhnhenne, M. T1 - Passive und aktive Maßnahmen zur Flächenkühlung im Stahl(leicht)bau JF - Bauingenieur N2 - Mit steigenden Dämmstandards und höheren Komfortanforderungen der Nutzer gerät die Problematik der sommerlichen Überhitzung zunehmend in den Fokus. Um die Überhitzung möglichst gering zu halten, sind Maßnahmen und Lösungen zu entwickeln, die den potenziellen Kühlbedarf eines Gebäudes vermeiden sowie reduzieren. Im Rahmen des europäischen Forschungsprojektes BATIMASS wurden Techniken untersucht, die die sommerliche Raumtemperatur ohne zusätzliche Kühlung (passiv) oder aber mit energieeffizienter wasserbasierter Flächenkühlung (aktiv) reduzieren und die besonders für Gebäude in Stahl(leicht)bauweise geeignet sind. Dafür wurde die Methodik der thermisch äquivalenten Decke weiterentwickelt, um das thermische Verhalten von Profilblechdecken in Gebäuden für beide Lösungsansätze analysieren zu können. Darüber hinaus wurde der Einsatz von Phasenwechselmaterial (PCM) zur Steigerung der Speicherfähigkeit von leichten Decken mit besonders geringer thermischer Masse in Simulationen sowie im Labor untersucht und bewertet. Y1 - 2016 U6 - http://dx.doi.org/10.37544/0005-6650-2016-07-08-63 SN - 0005-6650 N1 - gedruckt in der Bereichsbibliothek Bayernallee unter der Signatur 13 Z 049 VL - 91 IS - Jul/Aug SP - 309 EP - 316 PB - VDI Fachmedien CY - Düsseldorf ER - TY - RPRT A1 - Döring, Bernd T1 - Nutzung erneuerbarer Energien in Landesbauten : Dokumentation realisierter und geplanter Anlagen Y1 - 1997 SN - 3-930860-51-1 PB - Landesinstitut für Bauwesen des Landes Nordrhein-Westfalen CY - Aachen ER - TY - JOUR A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Ebbert, Thiemo A1 - Hachul, Helmut A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Nutzung erneuerbarer Energien durch thermische Aktivierung von Komponenten aus Stahl JF - Stahlbau N2 - Die Versorgung von Neubauten soll möglichst weitgehend unabhängig von fossilen Energieträgern erfolgen. Erneuerbare Energien spielen dafür eine gewichtige Rolle. Eine gute Möglichkeit, erneuerbare Energien ohne viel zusätzlichen Aufwand nutzbar zu machen, ist, bereits vorhandenen Komponenten im Gebäude zusätzliche Funktionen zu geben. Hier kann bspw. die Fassade oder das Dach solarthermisch aktiviert oder durch Fotovoltaikmodule ergänzt werden. Auch Tiefgründungen können neben der statischen Funktion noch eine geothermische Funktion zur Aufnahme oder Abgabe von Wärme erhalten. Neben der Erzeugung bietet sich auch für die Verteilung der Wärme oder Kälte im Gebäude die Integration in Bauteile an. Hier kann bspw. der Boden durch eine Fußbodenheizung oder die Decke durch Deckenstrahlplatten aktiviert werden. Im Rahmen der Veröffentlichung wird auf die thermische Aktivierung von Stahlkomponenten eingegangen. Es wird eine Lösung vorgestellt, die vorgehängte hinterlüftete Stahlfassade (VHF) solarthermisch zu aktivieren. Außerdem werden zwei Möglichkeiten zur geothermischen Aktivierung von Tiefgründungen mittels Stahlpfählen gezeigt. Zuletzt wird ein System zur thermischen Aktivierung von Stahltrapezprofilen an der Decke erläutert, welches Wärme zuführen oder bei Bedarf abführen kann. Y1 - 2020 U6 - http://dx.doi.org/10.1002/stab.202000031 SN - 1437-1049 VL - 2020 IS - Volume 89, Issue 6512-519 SP - 512 EP - 519 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Reger, Vitali A1 - Kuhnhenne, Markus T1 - Net-exergetic, hydraulic and thermal optimization of coaxial heat exchangers using fixed flow conditions instead of fixed flow rates JF - Geothermal Energy N2 - Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar fow and 60% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the fow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics. Y1 - 2021 U6 - http://dx.doi.org/10.1186/s40517-021-00201-3 SN - 2195-9706 N1 - Corresponding author: Tobias Blanke VL - 9 IS - Article number: 19 PB - Springer CY - Berlin ER - TY - CHAP A1 - Kuhnhenne, Markus A1 - Feldmann, Markus A1 - Döring, Bernd A1 - Spranger, Sascha T1 - Luftdichtheit im Stahlleichtbau - Gebäudehüllen in Sandwichbauweise T2 - Dichte Gebäudehülle, Thermografie und Wohnungslüftung : 2. Europäisches BlowerDoor-Symposium : 16.3. - 17.3. 2007, Kassel Y1 - 2007 SP - 121 EP - 134 PB - Energie + Umwelt-Zentrum ER -