TY - CHAP A1 - Hagebeuker, Bianca A1 - Ringbeck, Thorsten A1 - Frydlewicz, Paul A1 - Jesorsky, Oliver A1 - Sünkel, Thomas ED - Grote, Caspar T1 - PMD-Sensoren als Schlüsselkomponenten für die mehrdimensionale Umfelderfassung des Fahrzeuginnenraums T2 - Begleittexte zum Entwicklerforum KFZ-Elektronik & FlexRay Solution Day : 15.Mai 2007, Ludwigsburg Y1 - 2007 N1 - Entwicklerforum Kfz-Elektronik <2007, Ludwigsburg> ; FlexRay Solution Day <2007, Ludwigsburg> SP - 287 EP - 296 PB - WEKA-Fachzeitschr.-Verl. CY - Poing ER - TY - CHAP A1 - Buxbaum, Bernd A1 - Schwarte, Rudolf A1 - Ringbeck, Thorsten ED - Korevaar, Eric John T1 - PMD-PLL: receiver structure for incoherent communication and ranging systems T2 - Optical wireless communications II / [SPIE Conference on Optical Wireless Communications II], 22 September 1999, Boston, Massachusetts. - (SPIE proceedings series ; 3850) Y1 - 1999 SN - 0-8194-3443-4 SN - 0038-7355 SN - 0277-786X N1 - Conference on Optical Wireless Communications <2, 1999, Boston, Mass.> SP - 116 EP - 130 PB - SPIE CY - Bellingham, Wash. ER - TY - CHAP A1 - Elsen, Ingo A1 - Kraiss, Karl-Friedrich A1 - Krumbiegel, Dirk T1 - Pixel based 3D object recognition with bidirectional associative memories T2 - International Conference on Neural Networks 1997 N2 - This paper addresses the pixel based recognition of 3D objects with bidirectional associative memories. Computational power and memory requirements for this approach are identified and compared to the performance of current computer architectures by benchmarking different processors. It is shown, that the performance of special purpose hardware, like neurocomputers, is between one and two orders of magnitude higher than the performance of mainstream hardware. On the other hand, the calculation of small neural networks is performed more efficiently on mainstream processors. Based on these results a novel concept is developed, which is tailored for the efficient calculation of bidirectional associative memories. The computational efficiency is further enhanced by the application of algorithms and storage techniques which are matched to characteristics of the application at hand. Y1 - 1997 SN - 0-7803-4122-8 N1 - June 9 - 12, 1997, Westin Galleria Hotel Houston, Texas, USA. SP - 1679 EP - 1684 PB - IEEE CY - New York ER - TY - JOUR A1 - Claessens, J. A1 - Fuchsberger, A. A1 - Günther, C. A1 - Horn, G. A1 - Howker, K. A1 - Hulsebosch, R.J. A1 - Mitchell, C. A1 - Paterson, K. A1 - Preneel, B. A1 - Schellekens, D. A1 - Schuba, Marko T1 - Pioneering Advanced Mobile Privacy and Security Y1 - 2003 N1 - electronic proceedings of the 18th IFIP International Information Security Conference, Athens, Greece, May 2003 SP - 1 EP - 17 ER - TY - JOUR A1 - Hulsebosch, R. J. A1 - Günther, C. A1 - Horn, C. A1 - Holtmanns, S. A1 - Howker, K. A1 - Paterson, K. A1 - Claessens, J. A1 - Schuba, Marko ED - Mitchell, Chris J. T1 - Pioneering Advanced Mobile Privacy and Security JF - Security for mobility Y1 - 2004 SN - 9781849190886 U6 - https://doi.org/10.1049/PBTE051E_ch N1 - IEE telecommunications series ; 51 SP - 383 EP - 432 PB - Institution of Electrical Engineers CY - London ER - TY - JOUR A1 - Prume, Klaus A1 - Muralt, P. A1 - Calame, F. A1 - Schmitz-Kempen, T. T1 - Piezoelectric thin films: evaluation of electrical and electromechanical characteristics for MEMS devices / Prume, K. ; Muralt, P. ; Calame, F. ; Schmitz-Kempen, T. ; Tiedke, S. ; JF - IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. 54 (2007), H. 1 Y1 - 2007 SN - 0885-3010 SP - 81 EP - 14 ER - TY - CHAP A1 - Brandes, Sinja A1 - Epple, U. A1 - Gligorevic, Snjezana A1 - Schnell, Michael A1 - Haindl, Bernhard A1 - Sajatovic, Miodrag T1 - Physical layer specification of the L-band Digital Aeronautical Communications System (L-DACS1) T2 - Integrated Communications, Navigation and Surveillance Conference : ICNS '09 : 13 - 15 May 2009, Arlington, Va. Y1 - 2009 SN - 978-1-4244-4733-6 ; 978-1-4244-4734-3 SP - 1 EP - 12 ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Gudat, W. A1 - Kunz, C. T1 - Photoabsorption of alloys of Al with transition metals V, Fe, Ni and Cu and Pr near the Al L₂,₃-edge JF - Solid State Communications N2 - The onset of Al 2p transitions of VAl₃, FeAl, NiAl, NiAl₃, CuAl₂, PrAl₂ and the disordered alloys V-Al (16 at % Al, 28%, 41%), Fe-Al (11%) is shifted up to 1.1 eV. New pronounced structure develops close to the onset which for NiAl agrees with a density of states calculation by Connolly and Johnson. Y1 - 1974 SN - 0038-1098 U6 - https://doi.org/10.1016/0038-1098(74)91165-X VL - 15 IS - 3 SP - 655 EP - 658 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Gudat, W. A1 - Kunz, C. T1 - Photoabsorption coefficient of alloys of Al with transition metals V, Fe, Ni and Cu and Pr from 30 to 150 eV photon energy JF - Physica status solidi b N2 - The absorption coefficient of VAI3, FeAI, NiAI, NiAl2, CuAI2, PrAl2, and of disordered V–AI (16 at% AI, 28%, 41%) and Fe–AI (11%) alloys has been measured in the region of the M₂,₃ absorption of the transition metals and the Labsorption of AI. The strong changes of the AI spectrum in the region of the 100 eV maximum upon alloying are explained as another evidence of the EXAFS (extended X-ray absorption fine structure) nature of these structures. The broad, prominent absorption peaks from the 3p excitations in V and Fe and from the 4d excitations in Pr are influenced only little on allyoing and thus appear to be of atomic origin. The fine structure at the onset of the Pr 4d transitions is identical in the metal and the alloy but differs from that of Pr oxide. The only M₂,₃ edge which is detectably shifted is that of Ni (up to 2.1 eV), whereas the onset of the AI L₂,₃ edge is shifted in all the alloys (up to 1.1 eV). The shifts are interpreted in accordance with X-ray fluorescence and nuclear resonance measurements as changes of the density of states in the valence band of the alloys. Y1 - 1976 SN - 0031-8957 U6 - https://doi.org/10.1002/pssb.2220740211 N1 - weitere ISSN 0370-1972 VL - 74 IS - 2 SP - 507 EP - 521 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Vos, Eline K. A1 - Maas, Marnix C. A1 - Bitz, Andreas A1 - Orzada, Stephan A1 - Uden, Mark J. van A1 - Kobus, Thiele A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - Phosphorus magnetic resonance spectroscopic imaging at 7 T in patients with prostate cancer JF - Investigative Radiology N2 - Objectives The aim of this study was to identify characteristics of phosphorus (³¹P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo ³¹P magnetic resonance spectroscopic imaging (MRSI) at 7 T. Materials and Methods In this institutional review board–approved study, 15 patients with biopsy-proven prostate cancer underwent T₂-weighted magnetic resonance imaging and 3-dimensional ³¹P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles. Phosphorus metabolite ratios were determined and compared between tissue types. Results Signals of phosphoethanolamine (PE) and phosphocholine (PC) were present and well resolved in most ³¹P spectra in the prostate. Glycerophosphocholine signals were observable in 43% of the voxels in malignant tissue, but in only 10% of the voxels in normal-appearing tissue away from the seminal vesicles. In many spectra, independent of tissue type, 2 peaks resonated in the chemical shift range of inorganic phosphate, possibly representing 2 separate pH compartments. The PC/PE ratio in the seminal vesicles was highly elevated compared with the prostate in 5 patients. A considerable overlap of ³¹P metabolite ratios was found between prostate cancer and normal-appearing prostate tissue, preventing direct discrimination of these tissues. The only 2 patients with high Gleason scores tumors (≥4+5) presented with high PC and glycerophosphocholine levels in their cancer lesions. Conclusions Phosphorus MRSI at 7 T shows distinct features of phospholipid metabolites in the prostate gland and its surrounding structures. In this exploratory study, no differences in ³¹P metabolite ratios were observed between prostate cancer and normal-appearing prostate tissue possibly because of the partial volume effects of small tumor foci in large MRSI voxels. Y1 - 2014 U6 - https://doi.org/10.1097/RLI.0000000000000012 SN - 1536-0210 VL - 49 IS - 5 SP - 363 EP - 372 PB - Lippincott Williams & Wilkins CY - Philadelphia, Pa. ER - TY - CHAP A1 - Harzheim, Thomas A1 - Heuermann, Holger T1 - Phase Repeatable Synthesizers as a New Harmonic Phase Standard for Nonlinear Network Analysis T2 - IEEE Transactions on Microwave Theory and Techniques Y1 - 2018 U6 - https://doi.org/10.1109/TMTT.2018.2817513 SP - 1 EP - 8 PB - IEEE ER - TY - JOUR A1 - Ritz, Thomas T1 - Personalized Information Services: Production and Distribution of these Services employing Mass-Customization Y1 - 2002 N1 - International Congress on Mass Media and Communications in the e-society of the 21st Century, Moskau, 17.-19.10.2002 ER - TY - CHAP A1 - Ritz, Thomas T1 - Personalized information services : an electronic information commodity and its production T2 - Electronic publishing '01 : 2001 in the digital publishing odyssey ; proceedings of an ICCC/IFIP conference held at the University of Kent at Canterbury, Kent, United Kingdom, 5 - 7 July, 2001 ; [proceedings of the Fifth Conference on Electronic Publishing] Y1 - 2001 SN - 1-58603-191-0 SP - 48 EP - 58 PB - IOS Press [u.a.] CY - Amsterdam ER - TY - JOUR A1 - Ritz, Thomas T1 - Personalized information services : an electronic information commodity and its production JF - International Journal of E-Business Strategy Management Y1 - 2000 SN - 1467-0305 VL - 2 IS - 2 ER - TY - JOUR A1 - Schuba, Marko A1 - Hermanns, Oliver T1 - Performance Investigations of the IP Multicast Architecture / Hermanns, Oliver ; Schuba, Marko JF - Performance of the IP Multicast Achitecture . Proceedings JENC 6. Proceedings of the 6th Joint European Networking Conference, Tel Aviv Y1 - 1995 N1 - Reprinted in Computer Networks and ISDN Systems 28 pp 429-439, 1996 SP - 121-1 EP - 121-8 ER - TY - JOUR A1 - Schuba, Marko A1 - Haverkort, Boudewijn R. A1 - Schneider, Gaby T1 - Performance evaluation of multicast communication in packet-switched networks / Schuba, Marko ; Haverkort, Boudewijn R. ; Schneider, Gaby JF - Performance Evaluation. 39 (2000), H. 1-4 Y1 - 2000 SN - 0166-5316 N1 - http://dx.doi.org/10.1016/S0166-5316(99)00058-9 SP - 61 EP - 80 ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Orzada, Stephan A1 - Flöser, Martina A1 - Rietsch, Stefan H. G. A1 - Schmidt, Simon A1 - Stelter, Jonathan K. A1 - Wittrich, Marco A1 - Quick, Harald H. A1 - Bitz, Andreas A1 - Ladd, Mark E. T1 - Performance and safety assessment of an integrated transmit array for body imaging at 7 T under consideration of specificabsorption rate, tissue temperature, and thermal dose JF - NMR in Biomedicine N2 - In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil. KW - body imaging at 7 T MRI KW - thermal dose KW - tissue temperature KW - transmit antenna arrays Y1 - 2022 U6 - https://doi.org/10.1002/nbm.4656 SN - 0952-3480 (Print) SN - 1099-1492 (Online) VL - 35 IS - 5 SP - 1 EP - 17 PB - Wiley ER - TY - JOUR A1 - Schuba, Marko T1 - Performance Analysis of Reliable Multicast Mechanisms for Widely Spread Distributed Applications in the Internet JF - International Conference on Parallel and Distributed Processing Techniques and Applications : PDPTA '99 ; June 28 - July 1, 1999, Las Vegas, Nevada, USA / ed.: Hamid R. Arabnia Y1 - 1999 SN - 1892512157 SP - 1 EP - 7 ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Orzada, Stephan A1 - Flöser, Martina A1 - Rietsch, Stefan H. G. A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - Performance analysis of integrated RF microstrip transmit antenna arrays with high channel count for body imaging at 7 T JF - NMR in Biomedicine N2 - The aim of the current study was to investigate the performance of integrated RF transmit arrays with high channel count consisting of meander microstrip antennas for body imaging at 7 T and to optimize the position and number of transmit ele- ments. RF simulations using multiring antenna arrays placed behind the bore liner were performed for realistic exposure conditions for body imaging. Simulations were performed for arrays with as few as eight elements and for arrays with high channel counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of freedom for RF shimming in the abdomen. Worst-case specific absorption rate (SARwc ), SAR overestimation in the matrix compression, the number of virtual obser- vation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming was performed in differently oriented regions of interest in the body, and the devia- tion from a target B1+ field was evaluated. Results show that integrated multiring arrays are able to generate homogeneous B1+ field distributions for large FOVs, espe- cially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical workflow; however, a low duty cycle or a high SAR is required to achieve homoge- neous B1+ distributions and to exploit the full potential. In conclusion, integrated arrays allow for high element counts that have high degrees of freedom for the pulse optimization but also produce high SARwc , which reduces the SAR accuracy in the VOP compression for low-SAR protocols, leading to a potential reduction in array performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a high number of VOPs, which increases the computational cost for VOP evaluation and makes online SAR monitoring or pulse optimization challenging. Arrays with interleaved rings showed the best results in the study. KW - body imaging at UHF MRI KW - integrated transmit coil arrays KW - VOP compression Y1 - 2021 U6 - https://doi.org/10.1002/nbm.4515 SN - 0952-3480 (ISSN) SN - 1099-1492 (eISSN) VL - 34 IS - 7 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Geittner, P. T1 - PCVD hybrid technology for single mode fibres. Hagemann, H. J.; Geittner, P. JF - Proceedings : papers presented at: the 8th Annual European Fibre Optic Communications and Local Area Networks Exposition Y1 - 1990 N1 - EFOC LAN <8, 1990, München> SP - 67 EP - 72 ER -