TY - JOUR A1 - Valero, Daniel A1 - Bung, Daniel Bernhard T1 - Vectrino profiler spatial filtering for shear flows based on the mean velocity gradient equation JF - Journal of Hydraulic Engineering N2 - A new methodology is proposed to spatially filter acoustic Doppler velocimetry data from a Vectrino profiler based on the differential mean velocity equation. Lower and upper bounds are formulated in terms of physically based flow constraints. Practical implementation is discussed, and its application is tested against data gathered from an open-channel flow over a stepped macroroughness surface. The method has proven to detect outliers occurring all over the distance range sampled by the Vectrino profiler and has shown to remain applicable out of the region of validity of the velocity gradient equation. Finally, a statistical analysis suggests that physically obtained bounds are asymptotically representative. Y1 - 2018 U6 - https://doi.org/10.1061/(ASCE)HY.1943-7900.0001485 SN - 0733-9429 N1 - Article number 04018037 VL - 144 IS - 7 PB - ASCE CY - Reston, Va. ER - TY - JOUR A1 - Heuermann, Holger A1 - Ibrahim, Irfan A1 - Hillebrand, J. T1 - Vector-Signal-Generator with Two ¿¿-PLL's / Ibrahim, I. ; Hillebrand, J. ; Heuermann, H. JF - European Conference on Wireless Technologies, 2007. ECWT 2007 ; 8 - 10 October 2007 Munich, Germany Y1 - 2007 SN - 978-2-87487-003-3 SP - 1 EP - 4 ER - TY - JOUR A1 - Pieper, Martin T1 - Vector hyperinterpolation on the sphere JF - Journal of approximation theory. 156 (2009), H. 2 Y1 - 2009 SN - 0021-9045 SP - 173 EP - 186 ER - TY - JOUR A1 - Giresini, Linda A1 - Sassu, Mauro A1 - Butenweg, Christoph A1 - Alecci, Valerio A1 - De Stefano, Mario T1 - Vault macro-element with equivalent trusses in global seismic analyses JF - Earthquakes and Structures N2 - This paper proposes a quick and simplified method to describe masonry vaults in global seismic analyses of buildings. An equivalent macro-element constituted by a set of six trusses, two for each transverse, longitudinal and diagonal direction, is introduced. The equivalent trusses, whose stiffness is calculated by fully modeled vaults of different geometry, mechanical properties and boundary conditions, simulate the vault in both global analysis and local analysis, such as kinematic or rocking approaches. A parametric study was carried out to investigate the influence of geometrical characteristics and mechanical features on the equivalent stiffness values. The method was numerically validated by performing modal and transient analysis on a three naves-church in the elastic range. Vibration modes and displacement time-histories were compared showing satisfying agreement between the complete and the simplified models. This procedure is particularly useful in engineering practice because it allows to assess, in a simplified way, the effectiveness of strengthening interventions for reducing horizontal relative displacements between vault supports. KW - vault KW - macro-element KW - equivalent stiffness KW - truss KW - churches Y1 - 2017 U6 - https://doi.org/10.12989/eas.2017.12.4.409 SN - 2092-7614 (Print) SN - 2092-7622 (Online) VL - 12 IS - 4 SP - 409 EP - 423 PB - Techno-Press CY - Taejŏn ER - TY - JOUR A1 - Conzen, Catharina A1 - Albanna, Walid A1 - Weiss, Miriam A1 - Kürten, David A1 - Vilser, Walthard A1 - Kotliar, Konstantin A1 - Zäske, Charlotte A1 - Clusmann, Hans A1 - Schubert, Gerrit Alexander T1 - Vasoconstriction and Impairment of Neurovascular Coupling after Subarachnoid Hemorrhage: a Descriptive Analysis of Retinal Changes JF - Translational Stroke Research N2 - Impaired cerebral autoregulation and neurovascular coupling (NVC) contribute to delayed cerebral ischemia after subarachnoid hemorrhage (SAH). Retinal vessel analysis (RVA) allows non-invasive assessment of vessel dimension and NVC hereby demonstrating a predictive value in the context of various neurovascular diseases. Using RVA as a translational approach, we aimed to assess the retinal vessels in patients with SAH. RVA was performed prospectively in 24 patients with acute SAH (group A: day 5–14), in 11 patients 3 months after ictus (group B: day 90 ± 35), and in 35 age-matched healthy controls (group C). Data was acquired using a Retinal Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and NVC using flicker-light excitation. Diameter of retinal vessels—central retinal arteriolar and venular equivalent—was significantly reduced in the acute phase (p < 0.001) with gradual improvement in group B (p < 0.05). Arterial NVC of group A was significantly impaired with diminished dilatation (p < 0.001) and reduced area under the curve (p < 0.01) when compared to group C. Group B showed persistent prolonged latency of arterial dilation (p < 0.05). Venous NVC was significantly delayed after SAH compared to group C (A p < 0.001; B p < 0.05). To our knowledge, this is the first clinical study to document retinal vasoconstriction and impairment of NVC in patients with SAH. Using non-invasive RVA as a translational approach, characteristic patterns of compromise were detected for the arterial and venous compartment of the neurovascular unit in a time-dependent fashion. Recruitment will continue to facilitate a correlation analysis with clinical course and outcome. Y1 - 2018 U6 - https://doi.org/10.1007/s12975-017-0585-8 SN - 1868-601X IS - 9 SP - 284 EP - 293 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Yazdanbakhsh, Pedram A1 - Solbach, Klaus A1 - Bitz, Andreas T1 - Variable power combiner for RF mode shimming in 7-T MR imaging JF - IEEE Transaction on Biomedical Engineering N2 - This contribution discusses the utilization of RF power in an MRI system with RF mode shimming which enables the superposition of circularly polarized modes of a transmit RF coil array driven by a Butler matrix. Since the required power for the individual modes can vary widely, mode-shimming can result in a significant underutilization of the total available RF power. A variable power combiner (VPC) is proposed to improve the power utilization: it can be realized as a reconfiguration of the MRI transmit system by the inclusion of one additional matrix network which receives the power from all transmit amplifiers at its input ports and provides any desired (combined) power distribution at its output ports by controlling the phase and amplitude of the amplifiers’ input signals. The power distribution at the output ports of the VPC is then fed into the “mode” ports of the coil array Butler matrix in order to superimpose the spatial modes at the highest achievable power utilization. The VPC configuration is compared to the standard configuration of the transmit chain of our MRI system with 8 transmit channels and 16 coils. In realistic scenarios, improved power utilization was achieved from 17% to 60% and from 14% to 55% for an elliptical phantom and a region of interest in the abdomen, respectively, and an increase of the power utilization of 1 dB for a region of interest in the upper leg. In general, it is found that the VPC allows significant improvement in power utilization when the shimming solution demands only a few modes to be energized, while the technique can yield loss in power utilization in cases with many modes required at high power level. Y1 - 2012 U6 - https://doi.org/10.1109/TBME.2012.2205926 SN - 1558-2531 VL - 59 IS - 9 SP - 2549 EP - 2557 PB - IEEE CY - New York ER - TY - JOUR A1 - Jablonowski, Nicolai David A1 - Kollmann, Tobias A1 - Nabel, Moritz A1 - Damm, Tatjana A1 - Klose, Holger A1 - Müller, Michael A1 - Bläsing, Marc A1 - Seebold, Sören A1 - Krafft, Simone A1 - Kuperjans, Isabel A1 - Dahmen, Markus A1 - Schurr, Ulrich T1 - Valorization of Sida (Sida hermaphrodita) biomass for multiple energy purposes JF - GCB [Global Change Biology] Bioenergy N2 - The performance and biomass yield of the perennial energy plant Sida hermaphrodita (hereafter referred to as Sida) as a feedstock for biogas and solid fuel was evaluated throughout one entire growing period at agricultural field conditions. A Sida plant development code was established to allow comparison of the plant growth stages and biomass composition. Four scenarios were evaluated to determine the use of Sida biomass with regard to plant development and harvest time: (i) one harvest for solid fuel only; (ii) one harvest for biogas production only; (iii) one harvest for biogas production, followed by a harvest of the regrown biomass for solid fuel; and (iv) two consecutive harvests for biogas production. To determine Sida's value as a feedstock for combustion, we assessed the caloric value, the ash quality, and melting point with regard to DIN EN ISO norms. The results showed highest total dry biomass yields of max. 25 t ha⁻¹, whereas the highest dry matter of 70% to 80% was obtained at the end of the growing period. Scenario (i) clearly indicated the highest energy recovery, accounting for 439 288 MJ ha⁻¹; the energy recovery of the four scenarios from highest to lowest followed this order: (i) ≫ (iii) ≫ (iv) > (ii). Analysis of the Sida ashes showed a high melting point of >1500 °C, associated with a net calorific value of 16.5–17.2 MJ kg⁻¹. All prerequisites for DIN EN ISO norms were achieved, indicating Sida's advantage as a solid energy carrier without any post-treatment after harvesting. Cell wall analysis of the stems showed a constant lignin content after sampling week 16 (July), whereas cellulose had already reached a plateau in sampling week 4 (April). The results highlight Sida as a promising woody, perennial plant, providing biomass for flexible and multipurpose energy applications. Y1 - 2016 U6 - https://doi.org/10.1111/gcbb.12346 SN - 1757-1707 (online) SN - 1757-1693 (print) N1 - Special Issue: Perennial biomass crops for a resource constrained world VL - 9 IS - 1 SP - 202 EP - 214 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - German, Laura A1 - Mikucki, Jill A. A1 - Welch, Susan A. A1 - Welch, Kathleen A. A1 - Lutton, Anthony A1 - Dachwald, Bernd A1 - Kowalski, Julia A1 - Heinen, Dirk A1 - Feldmann, Marco A1 - Francke, Gero A1 - Espe, Clemens A1 - Lyons, W. Berry T1 - Validation of sampling antarctic subglacial hypersaline waters with an electrothermal ice melting probe (IceMole) for environmental analytical geochemistry JF - International Journal of Environmental Analytical Chemistry N2 - Geochemical characterisation of hypersaline waters is difficult as high concentrations of salts hinder the analysis of constituents at low concentrations, such as trace metals, and the collection of samples for trace metal analysis in natural waters can be easily contaminated. This is particularly the case if samples are collected by non-conventional techniques such as those required for aquatic subglacial environments. In this paper we present the first analysis of a subglacial brine from Taylor Valley, (~ 78°S), Antarctica for the trace metals: Ba, Co, Mo, Rb, Sr, V, and U. Samples were collected englacially using an electrothermal melting probe called the IceMole. This probe uses differential heating of a copper head as well as the probe’s sidewalls and an ice screw at the melting head to move through glacier ice. Detailed blanks, meltwater, and subglacial brine samples were collected to evaluate the impact of the IceMole and the borehole pump, the melting and collection process, filtration, and storage on the geochemistry of the samples collected by this device. Comparisons between melt water profiles through the glacier ice and blank analysis, with published studies on ice geochemistry, suggest the potential for minor contributions of some species Rb, As, Co, Mn, Ni, NH4+, and NO2−+NO3− from the IceMole. The ability to conduct detailed chemical analyses of subglacial fluids collected with melting probes is critical for the future exploration of the hundreds of deep subglacial lakes in Antarctica. Y1 - 2021 U6 - https://doi.org/10.1080/03067319.2019.1704750 SN - 0306-7319 VL - 101 IS - 15 SP - 2654 EP - 2667 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Müller, Martin A1 - Hirschfeld, Julian A1 - Lambertz, Rita A1 - Schulze Lohoff, Andreas A1 - Lustfeld, Hans A1 - Pfeifer, Heinz A1 - Reißel, Martin T1 - Validation of a novel method for detecting and stabilizing malfunctioning areas in fuel cell stacks JF - Journal of power sources N2 - In this paper a setup for detecting malfunctioning areas of MEAs in fuel cell stacks is described. Malfunctioning areas generate electric cross currents inside bipolar plates. To exploit this we suggest bipolar plates consisting not of two but of three layers. The third one is a highly conducting layer and segmented such that the cross currents move along the segments to the surface of the stack where they can be measured by an inductive sensor. With this information a realistic model can be used to detect the malfunctioning area. Furthermore the third layer will prevent any current inhomogeneity of a malfunctioning cell to spread to neighbouring cells in the stack. In this work the results of measurements in a realistic cell setup will be compared with the results obtained in simulation studies with the same configuration. The basis for the comparison is the reliable characterisation of the electrical properties of the cell components and the implication of these results into the simulation model. The experimental studies will also show the limits in the maximum number of segments, which can be used for a reliable detection of cross currents. Y1 - 2014 U6 - https://doi.org/10.1016/j.jpowsour.2014.08.045 SN - 1873-2755 (E-Journal); 0378-7753 (Print) VL - 272 SP - 225 EP - 232 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Ihrig, H. T1 - Valence change and phase stability of 3d-doped BaTiO3 annealed in oxygen and hydrogen. Hagemann, H. J.; Ihrig, H. JF - Physical Review B.. 20 (1979), H. 9 Y1 - 1979 SN - 1095-3795 SP - 3871 EP - 3878 ER - TY - JOUR A1 - Blome, Hans-Joachim A1 - Priester, Wolfgang T1 - Vacuum energy in cosmic dynamics JF - Astrophysics and Space Science. 117 (1985), H. 2 Y1 - 1985 SN - 0004-640X SP - 327 EP - 335 ER - TY - JOUR A1 - Wagner, Torsten A1 - Miyamoto, K. A1 - Werner, Frederik A1 - Schöning, Michael Josef A1 - Yoshinobu, T. T1 - Utilising Digital Micro-Mirror Device (DMD) as Scanning Light Source for Light-Addressable Potentiometric Sensors (LAPS) Y1 - 2011 U6 - https://doi.org/10.1166/sl.2011.1620 VL - 9 IS - 2 SP - 812 EP - 815 PB - American Scientific Publishers CY - Stevenson Ranch, Calif. ER - TY - JOUR A1 - Hüning, Felix T1 - Using Trench PowerMOSFETs in Linear Mode JF - Power Electronics Europe (2012) N2 - If we think about applications for modern Power MOSFETs using trench technology, running them in linear mode may not be top of the priority list. Yet there are multiple uses for Trench Power MOSFETs in linear mode. In fact, even turning the device on and off in switching applications is a form of linear operation. Also, these components can be run in linear mode to protect the device against voltage surges. This article will illustrate the factors that need to be considered for linear operation and show how Trench Power MOSFETs are suited to it. Y1 - 2012 SN - 1748-3530 SP - 27 EP - 29 PB - DFA Media CY - Tonbridge ER - TY - JOUR A1 - Zange, Jochen A1 - Schopen, Kathrin A1 - Albracht, Kirsten A1 - Gerlach, Darius A. A1 - Frings-Meuthen, Petra A1 - Maffiuletti, Nicola A. A1 - Bloch, Wilhelm A1 - Rittweger, Jörn T1 - Using the Hephaistos orthotic device to study countermeasure effectiveness of neuromuscular electrical stimulation and dietary lupin protein supplementation, a randomised controlled trial JF - Plos one Y1 - 2017 U6 - https://doi.org/10.1371/journal.pone.0171562 VL - 12 IS - 2 ER - TY - JOUR A1 - Biener, Ernst A1 - Sasse, T. A1 - Wernhoff, T. T1 - Using harbour dredged material for combination sealing of the former Bockhorner Weg disposal site in Bremen, Germany JF - Proceedings of the International Harbour Congress. 13 (2003) Y1 - 2003 N1 - International Harbour Congress <13, 2003, Antwerpen> SP - 101 EP - 109 ER - TY - JOUR A1 - Ferrein, Alexander A1 - Fritz, Christian A1 - Lakemeyer, Gerhard T1 - Using Golog for Deliberation and Team Coordination in Robotic Soccer / Ferrein, Alexander ; Fritz, Christian ; Lakemeyer, Gerhard JF - Künstliche Intelligenz : KI. 19 (2005), H. 1 Y1 - 2005 SN - 0933-1875 SP - 24 EP - 30 ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro JF - Biosensors and Bioelectronics. 40 (2013), H. 1 Y1 - 2013 SN - 0956-5663 SP - 393 EP - 400 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Garhofer, Gerhard A1 - Bek, Toke A1 - Boehm, Andreas G. A1 - Gherghel, Doina A1 - Grundwald, Juan A1 - Jeppesen, Peter A1 - Kergoat, Hélène A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Lovasik, John V. A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Orgul, Selim A1 - Schmetterer, Leopold T1 - Use of the retinal vessel analyzer in ocular blood flow research JF - Acta Ophthalmol N2 - The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed. Y1 - 2010 U6 - https://doi.org/10.1111/j.1755-3768.2009.01587.x SN - 1755-3768 VL - 88 IS - 7 SP - 717 EP - 722 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Scheer, Nico A1 - Campos-Ortega, José A. T1 - Use of the Gal4-UAS technique for targeted gene expression in the zebrafish JF - Mechanism of Development Y1 - 1999 U6 - https://doi.org/10.1016/S0925-4773(98)00209-3 SN - 0925-4773 VL - 80 IS - 2 SP - 153 EP - 158 ER -