TY - JOUR A1 - Scheele, S. A1 - Bongaerts, Johannes A1 - Maurer, K.-H. A1 - Freudl, R. T1 - Sekretion einer Kofaktor-haltigen Oxidase durch Corynebacterium glutamicum JF - Chemie - Ingenieur - Technik (CIT) Y1 - 2009 SN - 1522-2640 (E-Journal); 0009-286X (Print) VL - Vol. 81 IS - Iss. 8 SP - 1309 ER - TY - JOUR A1 - Scheele, Sandra A1 - Oertel, Dan A1 - Bongaerts, Johannes A1 - Evers, Stefan A1 - Hellmuth, Hendrik A1 - Maurer, Karl-Heinz A1 - Bott, Michael A1 - Freudl, Roland T1 - Secretory production of an FAD cofactor-containing cytosolic enzyme (sorbitol–xylitol oxidase from Streptomyces coelicolor) using the twin-arginine translocation (Tat) pathway of Corynebacterium glutamicum JF - Microbial biotechnology Y1 - 2013 SN - 1751-7915 SP - 202 EP - 206 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Pilas, Johanna A1 - Selmer, Thorsten A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Screen-printed carbon electrodes modified with graphene oxide for the design of a reagent-free NAD+-dependent biosensor array JF - Analytical Chemistry Y1 - 2019 U6 - http://dx.doi.org/10.1021/acs.analchem.9b04481 VL - 91 IS - 23 SP - 15293 EP - 15299 PB - ACS Publications CY - Washington ER - TY - JOUR A1 - Wiegand, Sandra A1 - Dietrich, Sascha A1 - Hertel, Robert A1 - Bongaerts, Johannes A1 - Evers, Stefan A1 - Volland, Sonja A1 - Daniel, Rolf A1 - Liesegang, Heiko T1 - RNA-Seq of Bacillus licheniformis: active regulatory RNA features expressed within a productive fermentation JF - BMC genomics Y1 - 2013 SN - 1471-2164 VL - Vol. 14 SP - 667 PB - BioMed Central CY - London ER - TY - CHAP A1 - Kirchner, Patrick A1 - Henkel, H. A1 - Näther, Niko A1 - Spelthahn, H. A1 - Schneider, A. A1 - Berger, J. A1 - Kolstad, J. A1 - Friedrich, P. A1 - Schöning, Michael Josef T1 - RFID-basiertes Sensorsystem zur Realisierung intelligenter Verpackungen für die Nahrungsmittelindustrie T2 - KMU - innovativ: IKT 2008. CD-ROM : BMBF-Statustagung KMU - innovativ: IKT, Darmstadt, 17. - 18. Nov. 2008 Y1 - 2008 IS - CD-ROM-Ausg. PB - BMBF CY - Berlin ER - TY - JOUR A1 - Förster, Arnold T1 - Resonant tunneling diodes operating as modern quantum transport devices JF - Proceedings of the Tenth International Workshop on the Physics of Semiconductor Devices : (December 14 - 18, 1999) / ed.: Vikram Kumar ... - Vol. 2 Y1 - 2000 SN - 81-7023-998-2 N1 - International Workshop on the Physics of Semiconductor Devices <10, 1999, Delhi> SP - 966 EP - 966 PB - Allied Publ. CY - New Delhi [u.a.] ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Danylyuk, S. V. A1 - Konakova, R. V. A1 - Sheka, D. I. T1 - Resonant spectroscopy of electric-field-induced superlattices JF - Journal of Applied Physics. 90 (2001), H. 6 Y1 - 2001 SN - 1089-7550 U6 - http://dx.doi.org/10.1063/1.1392956 SP - 2857 EP - 2861 ER - TY - JOUR A1 - Pourshahidi, Ali Mohammad A1 - Engelmann, Ulrich M. A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Resolving ambiguities in core size determination of magnetic nanoparticles from magnetic frequency mixing data JF - Journal of Magnetism and Magnetic Materials N2 - Frequency mixing magnetic detection (FMMD) has been widely utilized as a measurement technique in magnetic immunoassays. It can also be used for the characterization and distinction (also known as “colourization”) of different types of magnetic nanoparticles (MNPs) based on their core sizes. In a previous work, it was shown that the large particles contribute most of the FMMD signal. This leads to ambiguities in core size determination from fitting since the contribution of the small-sized particles is almost undetectable among the strong responses from the large ones. In this work, we report on how this ambiguity can be overcome by modelling the signal intensity using the Langevin model in thermodynamic equilibrium including a lognormal core size distribution fL(dc,d0,σ) fitted to experimentally measured FMMD data of immobilized MNPs. For each given median diameter d0, an ambiguous amount of best-fitting pairs of parameters distribution width σ and number of particles Np with R2 > 0.99 are extracted. By determining the samples’ total iron mass, mFe, with inductively coupled plasma optical emission spectrometry (ICP-OES), we are then able to identify the one specific best-fitting pair (σ, Np) one uniquely. With this additional externally measured parameter, we resolved the ambiguity in core size distribution and determined the parameters (d0, σ, Np) directly from FMMD measurements, allowing precise MNPs sample characterization. Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jmmm.2022.169969 SN - 0304-8853 VL - 563 IS - In progress, Art. No. 169969 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bäcker, M. A1 - Rakowski, D. A1 - Krappen, E. A1 - Schöning, Michael Josef T1 - Reinigungsprozesse in der Lebensmittelindustrie. Entwicklung eines Demonstrators zur Überwachung JF - GIT Labor-Fachzeitschrift Y1 - 2017 SN - 0016-3538 VL - 61 IS - 8 SP - 26 EP - 28 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Recent progress in silicon-based biologically sensitive field-effect devices JF - Current Opinion in Electrochemistry N2 - Biologically sensitive field-effect devices (BioFEDs) advantageously combine the electronic field-effect functionality with the (bio)chemical receptor’s recognition ability for (bio)chemical sensing. In this review, basic and widely applied device concepts of silicon-based BioFEDs (ion-sensitive field-effect transistor, silicon nanowire transistor, electrolyte-insulator-semiconductor capacitor, light-addressable potentiometric sensor) are presented and recent progress (from 2019 to early 2021) is discussed. One of the main advantages of BioFEDs is the label-free sensing principle enabling to detect a large variety of biomolecules and bioparticles by their intrinsic charge. The review encompasses applications of BioFEDs for the label-free electrical detection of clinically relevant protein biomarkers, deoxyribonucleic acid molecules and viruses, enzyme-substrate reactions as well as recording of the cell acidification rate (as an indicator of cellular metabolism) and the extracellular potential. Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.coelec.2021.100811 SN - 2451-9103 IS - Article number: 100811 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Recent developments of chemical imaging sensor systems based on the principle of the light-addressable potentiometric sensor JF - Sensors and actuators B: Chemical N2 - The light-addressable potentiometric sensor (LAPS) is an electrochemical sensor with a field-effect structure to detect the variation of the Nernst potential at its sensor surface, the measured area on which is defined by illumination. Thanks to this light-addressability, the LAPS can be applied to chemical imaging sensor systems, which can visualize the two-dimensional distribution of a particular target ion on the sensor surface. Chemical imaging sensor systems are expected to be useful for analysis of reaction and diffusion in various electrochemical and biological samples. Recent developments of LAPS-based chemical imaging sensor systems, in terms of the spatial resolution, measurement speed, image quality, miniaturization and integration with microfluidic devices, are summarized and discussed. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.snb.2014.09.002 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 207, Part B SP - 926 EP - 932 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Rysstad, G. A1 - Berger, J. A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 264 EP - 267 ER - TY - JOUR A1 - Kirchner, Patrick A1 - Spelthahn, H. A1 - Schöning, Michael Josef A1 - Henkel, H. A1 - Schneider, A. A1 - Friedrich, P. A1 - Kolstad, J. A1 - Berger, J. T1 - Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllanlagen JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 607 EP - 612 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Kirchner, Patrick A1 - Li, B. A1 - Spelthahn, H. A1 - Henkel, H. A1 - Schneider, A. A1 - Kolstad, J. A1 - Friedrich, P. A1 - Schöning, Michael Josef T1 - Realisierung eines miniaturisierten Gassensors in Chiptechnologie basierend auf einer Dünnschicht-Thermosäule zur H2O2-Detektion in aseptischen Abfüllanlagen JF - 9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.] Y1 - 2009 SN - 978-3-941298-44-6 N1 - Dresdner Sensor-Symposium ; (9, 2009, Dresden) SP - 293 EP - 296 PB - TUDpress CY - Dresden ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Rysstad, Gunnar A1 - Schöning, Michael Josef A1 - Keusgen, Michael T1 - Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Sensors and Actuators B: Chemical N2 - A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes. KW - Sterilisation process KW - Hydrogen peroxide KW - Polyimide KW - Calorimetric gas sensor Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2011.01.032 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 60 EP - 66 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bertz, Morten A1 - Molinnus, Denise A1 - Schöning, Michael Josef A1 - Homma, Takayuki T1 - Real-time monitoring of H₂O₂ sterilization on individual bacillus atrophaeus spores by optical sensing with trapping Raman spectroscopy JF - Chemosensors N2 - Hydrogen peroxide (H₂O₂), a strong oxidizer, is a commonly used sterilization agent employed during aseptic food processing and medical applications. To assess the sterilization efficiency with H₂O₂, bacterial spores are common microbial systems due to their remarkable robustness against a wide variety of decontamination strategies. Despite their widespread use, there is, however, only little information about the detailed time-resolved mechanism underlying the oxidative spore death by H₂O₂. In this work, we investigate chemical and morphological changes of individual Bacillus atrophaeus spores undergoing oxidative damage using optical sensing with trapping Raman microscopy in real-time. The time-resolved experiments reveal that spore death involves two distinct phases: (i) an initial phase dominated by the fast release of dipicolinic acid (DPA), a major spore biomarker, which indicates the rupture of the spore’s core; and (ii) the oxidation of the remaining spore material resulting in the subsequent fragmentation of the spores’ coat. Simultaneous observation of the spore morphology by optical microscopy corroborates these mechanisms. The dependence of the onset of DPA release and the time constant of spore fragmentation on H₂O₂ shows that the formation of reactive oxygen species from H₂O₂ is the rate-limiting factor of oxidative spore death. KW - DPA (dipicolinic acid) KW - sterilization KW - Bacillus atrophaeus spores KW - optical trapping KW - Raman spectroscopy KW - optical sensor setup Y1 - 2023 U6 - http://dx.doi.org/10.3390/chemosensors11080445 SN - 2227-9040 N1 - This article belongs to the Special Issue "Biosensors and Chemical Sensors for Food and Healthcare Monitoring—Celebrating the 10th Anniversary" VL - 8 IS - 11 PB - MDPI CY - Basel ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schusser, Sebastian A1 - Bäcker, M. A1 - Leinhos, Marcel A1 - Schöning, Michael Josef T1 - Real-time in-situ electrical monitoring of the degradation of biopolymers using semiconductor field-effect devices T2 - Biodegradable biopolymers. Vol. 1 Y1 - 2015 SN - 978-1-63483-632-6 SP - 135 EP - 153 PB - Nova Science Publ. CY - Hauppauge ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fleischer, M. A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 17 EP - 20 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Geissler, Hanno A1 - Schöning, Michael Josef T1 - Rapid methods and sensors for milk quality monitoring and spoilage detection JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2019.04.040 SN - 0956-5663 VL - 140 IS - Article 111272 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Grinsven, B. van A1 - Bon, N. vanden A1 - Grieten, L. A1 - Murib, M. A1 - Janssen, S. D. A1 - Haenen, K. A1 - Schneider, E. A1 - Ingebrandt, E. A1 - Schöning, Michael Josef A1 - Vermeeren, V. A1 - Ameloot, M. A1 - Michiels, L. A1 - Thoelen, R. A1 - Ceuninck, W. de A1 - Wagner, P. T1 - Rapid assessment of the stability of DNA duplexes by impedimetric real-time monitoring of chemically induced denaturation JF - Lab on a Chip Y1 - 2011 SN - 1473-0197 VL - 11 IS - 9 SP - 1656 EP - 1663 PB - Royal Society of Chemistry (RSC) CY - Cambridge ER -