TY - JOUR A1 - Meliß, Michael A1 - Neskakis, A. A1 - Plettner-Marliani, J. A1 - Lange, C. A1 - Hövelmann, A. A1 - Schumacher, J. T1 - Waste water recycling supplied by renewable energies : basic conditions and possible treatment technologies JF - Renewable energy. Vol. 14 (1998), iss. 1-4. 6th Arab International Solar Energy Conference: Bringing Solar Energy into the Daylight, Muscat, Sultanate of Oman, 29.03.-01.04.1998 Y1 - 1998 SN - 1879-0682 (E-Book); 0960-1481 (Print) SP - 325 EP - 331 ER - TY - JOUR A1 - Meliß, Michael T1 - Regenerative Energiequellen JF - Brennstoff, Wärme, Kraft : BWK ; das Energie-Fachmagazin. Bd. 50 (1998), H. 4 Y1 - 1998 SN - 0006-9612 (Print) ; 1436-4883 (E-Journal) N1 - Printausg. in der Bibliothek vorhanden: 63 Z 609-1998 SP - 74 EP - 81 ER - TY - RPRT A1 - Schwarzer, Klemens A1 - Höller, Robert T1 - EOS Ertragsverbesserung und Optimierung von Energie Systemen. Abschlussbericht BMBF 1700796 Y1 - 1998 ER - TY - CHAP A1 - Meliß, Michael T1 - Regenerative Energieträger T2 - Lexikon der Bioethik / hrsg. im Auftr. der Görres-Gesellschaft von Wilhelm Korff. Bd. 3 Y1 - 1998 SP - 168 EP - 175 PB - Gütersloher Verlagshaus CY - Gütersloh ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Timmer, H. T1 - Energetische und betriebswirtschaftliche Bewertung von Kühlsystemen für Kühllager JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 1998 SN - 1436-5103 VL - 49 IS - 9 SP - 74 EP - 77 PB - Springer CY - Düsseldorf ER - TY - RPRT A1 - Christ, Ansgar A1 - Groß, Rolf Fritz A1 - Renz, Ulrich T1 - Strömungs-, Filterkuchen- und Abreinigungsmodelle für Heißgasfilter, Teilvorhaben "Numerische Simulation des Abreinigungsvorganges und der Rohgasströmung" KW - Prozesssimulation KW - Filterkuchen KW - Druckvergasung KW - Druckwirbelschichtfeuerung KW - Rauchgasreinigung Y1 - 1998 U6 - http://dx.doi.org/10.2314/GBV:50431601X N1 - Verbundprojekt im Rahmen der Projektträgerschaft BEO des BMBF der Partner RWTH Aachen, Lehrstuhl für Wärmeübertragung und Klimatechnik Brandenburgische Technische Universität Cottbus, Lehrstuhl Regelungstechnik Universität Karlsruhe, Institut für Mechanische Verfahrenstechnik und Mechanik LLB Lurgi Lentjes Babcock Energietechnik GmbH, Oberhausen Förderkennzeichen: 0326831B Abschlußbericht ER - TY - RPRT A1 - Christ, Ansgar A1 - Groß, Rolf Fritz A1 - Renz, Ulrich T1 - HGR: Untersuchung zur Minimierung von gasförmigen Schadstoffen aus Rauchgasen bei der Heißgasfiltration T1 - Hot gas filtration: investigations to remove gaseous pollutant components out of flue gas during hot gas filtration N2 - Gas- und Dampfturbinen-Kraftwerke mit Druckwirbelschicht- oder mit Druckvergasungsverfahren ermöglichen die Verstromung von Kohle mit hohem Wirkungsgrad und niedrigen Emissionen. Eine Voraussetzung für den Betrieb dieser Anlagen ist die Entstaubung der Rauchgase bei hohen Temperaturen und Drücken. Abreinigungsfilter mit keramischen Elementen werden dazu eingesetzt. Eine Reduzierung gasförmiger Schadstoffe unter den gleichen Bedingungen könnte Rauchgaswäsche ersetzen. Ziel des Gesamtvorhabens ist es, die Integration von Heißgasfiltration und katalytischem Abbau der Schadstoffe Kohlenmonoxid, Kohlenwasserstoffe und Stickoxide in einen Verfahrensschritt zu untersuchen. Die Arbeitsschwerpunkte dieses Teilvorhabens betreffen: die katalytische Wirkung eisenhaltiger Braunkohlenaschen, die Wirksamkeit des Calciumaluminat als Katalysator des Abbaus unverbrannter Kohlenwasserstoffe im Heißgasfilter, numerische Simulation der kombinierten Abscheidung von Partikeln und gasförmigen Schadstoffen aus Rauchgasen N2 - Power plants with gas and steam turbines in pressurized fluidized bed or pressurized gasification processes enable power generation of coal with high efficiancy and little emissions. To run these plants the cleaning of the flue gas is necessary before entering the turbines under the conditions of high temperature and pressure. Ceramic filter elements are the most probable method for hot gas cleaning. A simultaneous reduction of gaseous pollutant components under these conditions could help to make the whole process more efficiant. The aim of the project is to integrate the catalytic reduction of carbon monoxide, hydrocarbons and nitric oxides into the hot gas filtration with ceramic filter elements as a one step mecanism. The project is focused on: the catalytic behaviour of ferrugious ashes of brown coal, the effectiveness of calcinated aluminates as a catalyst to remove uncombuste hydrocarbons in a hot gas filtration unit, numerical simulation of the combined removal of particels and gaseous pollutant components out of the flue gas. KW - Kraftwerkstechnik KW - Stickstoffoxide KW - Kohlenmonoxidbelastung KW - Schadgas KW - Heterogene Katalyse Y1 - 1998 U6 - http://dx.doi.org/10.2314/GBV:504318411 N1 - Verbundprojekt im Rahmen der Projektträgerschaft BEO des BMBF der Partner RWTH Aachen, Lehrstuhl für Wärmeübertragung und Klimatechnik uve Institut für Technische Chemie und Umweltschutz GmbH, Berlin-Adlershof Hugo Petersen, Gesellschaft für verfahrenstechnischen Anlagenbau mbH&Co.KG, Wiesbaden Förderkennzeichen: 0326819F [Abschlußdatum des Vorhabens: Dezember 1997] ER - TY - JOUR A1 - Göttsche, Joachim A1 - Hove, T. T1 - Mapping global, diffuse and beam solar radiation over Zimbabwe / T. Hove ; J. Göttsche JF - Renewable energy. 18 (1999), H. 4 Y1 - 1999 SN - 1879-0682 SP - 535 EP - 556 ER - TY - CHAP A1 - Meliß, Michael A1 - Späte, Frank A1 - Lange, Harald T1 - The Solar-Campus Jülich - an interdisciplinary project T2 - Building a new century. 5th Conference on Solar Architecture and Design, Bonn, 27th of May 1998. Ed. by Eurosolar e.V. Ed. by Irm Pontenagel. Y1 - 1999 SN - 3-933745-03-9 SP - 382 EP - 387 PB - Eurosolar-Verl. CY - Bonn ER - TY - BOOK A1 - Meliß, Michael T1 - REGLOB 99 : Globale Betrachtung regenerativer Energieressourcen und ihrer technischen Nutzungsmöglichkeiten Y1 - 1999 PB - Solar-Institut CY - Jülich ER - TY - CHAP A1 - Meliß, Michael T1 - Ein Hochschul-Curriculum für erneuerbare Energien T2 - Building a new century : 5th Conference on Solar Architecture and Design; Bonn, 27th of May 1998 / ed. by EUROSOLAR e. V. / ed. by Irm Pontenagel Y1 - 1999 SN - 3-933745-03-9 SP - 198 EP - 207 PB - Bonn CY - Eurosolar-Verl. ER - TY - RPRT A1 - Schwarzer, Klemens A1 - Hafner, Bernd T1 - Aufbau und Erprobung eines Latentwärmespeichers für den Einsatz in Raumheizungssystemen. Abschlussbericht BMBF 1700297 Y1 - 1999 ER - TY - JOUR A1 - Velraj, R. A1 - Seeniraj, R. V. A1 - Hafner, B. A1 - Faber, Christian A1 - Schwarzer, Klemens T1 - Heat transfer enhancement in a latent heat storage system JF - Solar energy. Vol. 65, iss. 3 Y1 - 1999 SN - 0038-092X SP - 171 EP - 180 ER - TY - JOUR A1 - Herrmann, Ulf A1 - Lippke, F. T1 - The influence of transients on the design of DSG solar fields JF - Journal de Physique IV : proceedings Y1 - 1999 SN - 2-86883-402-7 U6 - http://dx.doi.org/10.1051/jp4:1999377 SN - 1764-7177 (Online) SN - 1155-4339 (Print) VL - 9 IS - PR3 SP - 489 EP - 494 ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Hecken, M. A1 - Renz, Ulrich ED - Dittler, A. ED - Hemmer, G. ED - Kasper, G. T1 - Hot gas filtration with ceramic filter candles: experimental and numerical investigations on fluid flow during element cleaning T2 - High temperature gas cleaning. Vol. 2 N2 - Ceramic hot gas filters are widely used in combined cycles based on pressurised fluidised beds. They fulfil most of the demands with respect to cleaning efficiency and long time durability, but their operation regarding the consumption of pulse gas and energy still has to be optimised. Experimental investigations were carried out to measure the flow field, the pressure and the gas temperature inside the filter candle during pulse jet cleaning. These results are compared with the results of a numerical procedure based on a solution of the two - dimensional conservation equations for momentum and energy. The observed difficulties handling different flow regimes like highly turbulent flow as well as Darcy flow simultaneously are discussed. KW - 20 fossil-fueled power plants KW - hot gas cleanup KW - ceramics KW - filtration KW - gas flow Y1 - 1999 SN - 3-9805220-1-6 N1 - 4th International Symposium and Exhibition on Gas Cleaning at High Temperatures, 22.-24.09.1999, Karlsruhe SP - 862 EP - 873 PB - KIT Institut für Mechanische Verfahrenstechnik und Mechanik CY - Karlsruhe ER - TY - JOUR A1 - Meliß, Michael A1 - Späte, Frank T1 - The solar heating system with seasonal storage at the Solar-Campus Jülich JF - Solar energy. Vol. 69 (2000), iss. 6 Y1 - 2000 SN - 0038-092X SP - 525 EP - 533 ER - TY - CHAP A1 - Späte, Frank A1 - Hafner, B. A1 - Schwarzer, Klemens T1 - A system for solar process heat for decentralized applications in developing countries T2 - ISES 1999 Solar World Congress, Jerusalem, Israel, July 4-9, 1999 : conference proceedings / ed. Gershon Grossman. Vol. 3 Y1 - 2000 SN - 0-080-043895-4 SP - 236 EP - 291 PB - Elsevier CY - Oxford ER - TY - JOUR A1 - Wemhöner, Carsten A1 - Hafner, Bernd A1 - Schwarzer, Klemens T1 - Simulation of solar thermal systems with CARNOT blockset in the environment MATLAB-Simulink Y1 - 2000 SP - 1 EP - 6 ER - TY - JOUR A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz T1 - Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenkühltürmen JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Zwangsbelüftete Nasskühltürme haben im Gegensatz zur Trockenkühlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßkühlung die spezifische Kühlleistung durch abgeführte Kondensationswärme höher als bei der Trockenkühlung. Hybridzellenkühltürme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftströme die Wasserdampf-Sättigungsgrenze nicht überschreitet. Durch das Mischungsverhältnis kann man den gewünschten Sättigungsgrad einstellen. Je dichter dieser an der Sättigungsgrenze liegt, desto höher ist die Kühlleistung. Der von unten zugeführte Luftstrom der Naßkühlung und der seitlich zugeführte trockene Abluftstrom müssen sehr gut durchmischt werden, um über den gesamten Austrittsquerschnitt des Kühlturms die Sättigungsgrenze nicht zu überschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. Über ein Raster von 10 mal 10 Punkten wurde die örtliche Temperaturverteilung ermittelt. Wärmebilanzen ergeben dann die Mischungsgüte in einer Ebene oberhalb der Zellenkrone. Während ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 % liegt erhöhen Einbauten den Trockenluftanteil auf 30 % bis über 40 %. Dabei wurde die Trockenluft auf jeder Kühlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftauslässe umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gewünschten Mittelwert zeigen Potential für die weitere Verbesserung der Einbauten. KW - Trockenkühlturm KW - Nasskühlturm KW - kombiniertes Verfahren KW - Mischen KW - Abluft Y1 - 2000 SN - 1436-5103 VL - 51 IS - 8 SP - 48 EP - 49 PB - Springer CY - Düsseldorf ER - TY - CHAP A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz A1 - Renz, Ulrich ED - Jamal, Rahman ED - Jaschinski, Hans T1 - Messwerterfassung und –auswertung mit LabView: Experimentelle Analyse der Mischungsgüte in Hybridzellenkühltürmen T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000 N2 - Zur Kühlung von Abwärmeströmen aus Kraftwerksprozessen werden in zunehmenden Maße Hybridzellenkühltürme mit Zwangskonvektion eingesetzt, deren wesentlicher Vorteil ihre geringe Bauhöhe ist. Um bei derartigen Kühltürmen eine Sichtbehinderung oder Glatteisgefährdung durch bodennahen Nebel zu vermeiden, muss durch eine optimale Vermischung des Trocken- und Naßluftanteils gewährleistet sein, daß aus der Kühlturmkrone keine Nebelschwaden austreten. In Zusammenarbeit mit der Industrie betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen einen Versuchsstand zur Erfassung der Mischungsgüte in Hybridzellenkühltürmen. In maßstabsgerechter Nachbildung können dabei am Modell alle relevanten Einflußgrößen wie Kühlturmgeometrie, Gestaltung zusätzlicher Mischeinbauten sowie die Betriebsparameter variiert werden. Mit Hilfe einer unter LabView 5.01 erstellten Software werden sowohl die l3etriebszustüncle online überwacht, als auch die benötigten Meßwerte zur Bestimmung der Mischungsgüte erfaßt. Über die grafische Oberfläche können sämtliche Meßoptionen gesteuert sowie alle Meßdaten visualisiert und kontrolliert werden. In das LabView-Programm sind darüber hinaus Routinen zur Auswertung der Daten implementiert worden, die sowohl eine direkte Darstellung der Ergebnisse in Form von Diagrammen ermöglichen, als auch zur Weiterverarbeitung einen Datenexport in eine Microsoft- Excel-Tabelle vorsehen. N2 - The Institute of Heat Transfer and Air Conditioning at the Aachen University of Technology operates in co-operation with industrial partners a test facility in order to investigate mixture quality in hybrid cooling towers. In a scaled mock-up a variation of all relevant data such as the geometry of the cooling tower, the design of additional mixers and the operation parameters could be realized. A software tool, created with LabView 5.01, offers the possibility to control the whole process and to measure all relevant quantities. The graphic user interface permits an online control and a visualization of the measured values. Beyond this the program is not only able to evaluate the data and to represent the results in form of diagrams, but also to export the data directly into an Microsoft-Excel-sheet for further analysing. Y1 - 2000 SN - 3-7785-2789-4 (print) SP - 54 EP - 60 PB - Hüthig CY - Heidelberg ER -