TY - CHAP A1 - Edip, Kemal A1 - Garevski, Mihail A1 - Butenweg, Christoph A1 - Sheshov, Vlatko A1 - Bojadjieva, Julijana A1 - Gjorgjiev, Igor T1 - New coupled finite-infinite element approach for wave propagation simulation of unbounded soil media T2 - 2nd European Conference on Earthquake Engineering and Seismology 2014 (2nd ECEES) : joint event of the 15th European Conference on Earthquake Engineering and the 34th General Assembly of the European Seismological Commission : Istanbul, Turkey, 25-29 August 2014 / European Association for Earthquake Engineering (EAEE) ; Vol. 2 Y1 - 2014 SN - 978-1-5108-1021-1 SP - 1556 EP - 1561 PB - Curran Associates, Inc. CY - Red Hook, NY ER - TY - CHAP A1 - Dalguer, Luis A. A1 - Churilov, Sergey A1 - Butenweg, Christoph A1 - Renault, Philippe A1 - Hyun, An Jun T1 - Dynamic analysis of a reinforced concrete electrical nuclear building of SMART 2013 project subjected to earthquake excitation using ABAQUS T2 - Workshop SMART2013 : Paris, France, November 25th - 27th, 2014 Y1 - 2014 SP - 1 EP - 12 ER - TY - CHAP A1 - Altay, Okyay A1 - Butenweg, Christoph A1 - Klinkel, Sven A1 - Taddei, Francesca T1 - Vibration mitigation of wind turbine towers by tuned liquid column dampers T2 - Proceedings of the 9th European Conference on Structural Dynamics, EURODYN 2014 Porto, Portugal, 30 June - 2 July 2014 / A. Cunha, E. Caetano, .... (eds.) Y1 - 2014 SN - 978-972-752-165-4 SP - 1531 EP - 1538 CY - Porto ER - TY - CHAP A1 - Edip, Kemal A1 - Garevski, Mihail A1 - Butenweg, Christoph A1 - Sesov, Vlatko A1 - Bojadjieva, Julijana A1 - Gjorgjiev, Igor T1 - Boundary effects on seismic analysis of multi-storey frames considering soil structure interaction phenomenon T2 - Seismic design of industrial facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) ; [Aachen, 26. - 27. September 2013] / Chair of Structural Statics and Dynamics, RWTH Aachen. Sven Klinkel ..., ed Y1 - 2014 SN - 978-3-658-02809-1 (Print) ; 978-3-658-02810-7 U6 - https://doi.org/10.1007/978-3-658-02810-7_47 SP - 569 EP - 576 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Giresini, Linda A1 - Butenweg, Christoph A1 - Andreini, M. A1 - De Falco, A. A1 - Sassu, M. T1 - Numerical calibration of a macro-element for vaultes system in historic churches T2 - 9th International Conference on Structural Analyses of Historical Conctruction, 14 - 17 October, 2014, Mexico City Y1 - 2014 SP - 1 EP - 12 ER - TY - CHAP A1 - Rosin, Julia A1 - Butenweg, Christoph T1 - Seismic isolation of cylindrical liquid storage tanks T2 - Proceedings of the 9th European Conference on Structural Dynamics, EURODYN 2014 Porto, Portugal, 30 June - 2 July 2014 / A. Cunha, E. Caetano, .... (eds.) Y1 - 2014 SN - 978-972-752-165-4 SP - 3145 EP - 3152 CY - Porto ER - TY - CHAP A1 - Altay, Okyay A1 - Taddei, Francesca A1 - Butenweg, Christoph A1 - Klinkel, Sven T1 - Vibration mitigation of wind turbine towers with tuned mass dampers T2 - Wind turbine control and monitoring. (Advances in industrial control) N2 - Because of its minor environmental impact, electricity generation using wind power is getting remarkable. The further growth of the wind industry depends on technological solutions to the challenges in production and construction of the turbines. Wind turbine tower vibrations, which limit power generation efficiency and cause fatigue problems with high maintenance costs, count as one of the main structural difficulties in the wind energy sector. To mitigate tower vibrations auxiliary measures are necessary. The effectiveness of tuned mass damper is verified by means of a numeric study on a 5 MW onshore reference wind turbine. Hereby, also seismic-induced vibrations and soil–structure interaction are considered. Acquired results show that tuned mass damper can effectively reduce resonant tower vibrations and improve the fatigue life of wind turbines. This chapter is also concerned with tuned liquid column damper and a semiactive application of it. Due to its geometric versatility and low prime costs, tuned liquid column dampers are a good alternative to other damping measures, in particular for slender structures like wind turbines. Y1 - 2014 SN - 978-3-319-08412-1 (Print) ; 978-3-319-08413-8 (E-Book) U6 - https://doi.org/10.1007/978-3-319-08413-8_12 SP - 337 EP - 373 PB - Springer CY - Cham ; Heidelberg ; New York ; Dordrecht ; London ER - TY - BOOK A1 - Klinkel, Sven A1 - Butenweg, Christoph A1 - Lin, Gao A1 - Holtschoppen, Britta T1 - Seismic design of industrial facilities : Proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF) / Sven Klinkel, Christoph Butenweg, Gao Lin, Britta Holtschoppen Editors Y1 - 2014 SN - 978-3-658-02809-1 (Print) ; 978-365-80281-0-7 (E-Book) U6 - https://doi.org/10.1007/978-3-658-02810-7 PB - Springer Vieweg CY - Wiesbaden ER - TY - RPRT A1 - Butenweg, Christoph A1 - Kaiser, Diethelm T1 - Seismic hazard harmonisation in Europe (SHARE) : DGEB-Workshop in Frankfurt a.M., Germany, 27. May 2014 / Christoph Butenweg, Diethelm Kaiser (editors) Y1 - 2014 SN - 3-930108-12-7 PB - DGEB CY - Aachen ER - TY - CHAP A1 - Butenweg, Christoph A1 - Rajan, Sreelakshmy T1 - Design and construction techniques of AAC masonry buildings in earthquakes regions T2 - 10 years Xella research in Building Materials : Symposium on the 4th and 5th of September, Potsdam 2014 Y1 - 2014 ER - TY - CHAP A1 - Butenweg, Christoph A1 - Meyer, Udo A1 - Fehling, Ekkehard T1 - INSYSME: first activities of the German partners T2 - 9th International Masonry Conference 2014 in Guimaraes, Portugal, 2014 Y1 - 2014 ER - TY - CHAP A1 - Stollenwerk, Dominik A1 - Kuvarakul, T. A1 - Kuperjans, Isabel T1 - Renewable energy supply for power dominated, energy intense production processes - a systematic conversion approach for the anodizing process T2 - IOP conference series: Earth and environmental science (EES) Y1 - 2013 SN - 1755-1315 SN - 1755-1307 VL - Vol. 16 IS - H. 1 SP - 012142/1 EP - 012142/4 ER - TY - JOUR A1 - Sabitova, A. A1 - Ebert, Ph. A1 - Lenz, A. A1 - Schaafhausen, S. A1 - Ivanova, L. A1 - Dähne, M. A1 - Hoffmann, A. A1 - Dunin-Borkowski, R. E. A1 - Förster, Arnold A1 - Grandidier, B. A1 - Eisele, H. T1 - Intrinsic bandgap of cleaved ZnO(112¯0) surfaces JF - Applied physics letters Y1 - 2013 SN - 1077-3118 (E-Journal); 0003-6951 (Print) VL - Vol. 102 SP - 021608 ER - TY - CHAP A1 - Takenaga, Shoko A1 - Herrera, Cony F. A1 - Werner, Frederik A1 - Biselli, Manfred A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef A1 - Öhlschläger, Peter A1 - Wagner, Torsten T1 - Detection of the metabolic activity of cells by differential measurements based on a single light-addressable potentiometric sensor chip T2 - 11. Dresdner Sensor-Symposium : 9.-11.12.2013 Y1 - 2013 SN - 978-3-9813484-5-3 SP - 63 EP - 67 ER - TY - JOUR A1 - Mottaghy, Darius A1 - Schwamborn, G. A1 - Rath, V. T1 - Past climate changes and permafrost depth at the Lake El'gygytgyn site: implications from data and thermal modeling JF - Climate of the Past Y1 - 2013 U6 - https://doi.org/10.5194/cp-9-119-2013 SN - 1814-9332 VL - 9 IS - 1 SP - 119 EP - 133 PB - Copernicus CY - Katlenburg-Lindau ER - TY - JOUR A1 - Vogt, Christian A1 - Iwanowski-Strahser, Katha A1 - Marquart, Gabriele A1 - Arnold, Juliane A1 - Mottaghy, Darius A1 - Pechnig, Renate A1 - Gnjezda, Daniel A1 - Clauser, Christoph T1 - Modeling contribution to risk assessment of thermal production power for geothermal reservoirs JF - Renewable Energy Y1 - 2013 U6 - https://doi.org/10.1016/j.renene.2012.11.026 SN - 0960-1481 VL - 53 SP - 230 EP - 241 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Ziegler, M. A1 - Schüller, R. A1 - Mottaghy, Darius T1 - Numerical simulation of energy consumption of artificial ground freezing applications subject to water seepage T1 - Simulation numérique de la consummation d´énergie des applications pour la congélation artificielle du sol soumise au flux de l´eau souterraine T2 - Proceedings of the 18th International Conference on Soil Mechanics and Geotechnical Engineering, Paris 2013 Y1 - 2013 SP - 2985 EP - 2988 ER - TY - JOUR A1 - Marx, Ulrich A1 - Schenk, Friedrich A1 - Behrens, Jan A1 - Meyr, Ulrike A1 - Wanek, Paul A1 - Zang, Werner A1 - Schmitt, Robert A1 - Brüstle, Oliver A1 - Zenke, Martin A1 - Klocke, Fritz T1 - Automatic production of induced pluripotent stem cells JF - Procedia CIRP : First CIRP Conference on BioManufacturing Y1 - 2013 SN - 2212-8271 VL - Vol. 5 SP - 2 EP - 6 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Altay, Okyay A1 - Butenweg, Christoph A1 - Klinkel, Sven T1 - Vibration control of slender structures by semi-active tuned liquid column dampers T2 - Conference of the ASCE Engineering Mechanics Institute , Evanston, IL , USA , EMI 2013 , 2013-08-04 - 2013-08-07 Y1 - 2013 N1 - http://www.emi2013.northwestern.edu/openconf/modules/request.php?module=oc_program&action=view.php&a=&id=213&type=1 Seite kann nicht gefunden werden. ER - TY - CHAP A1 - Churilov, Sergej A1 - Dumova-Jovanoska, Elena A1 - Butenweg, Christoph ED - Adam, Christoph ED - Heuer, Rudolf ED - Lenhardt, Wolfgang ED - Schranz, Christian T1 - Seismic verification of existing masonry buildings and strengthening with reinforced concrete jackets T2 - Proceedings - Vienna Congress on Recent Advances in Earthquake Engineering and Structural Dynamics 2013 (VEESD 2013) N2 - A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia. Y1 - 2013 SN - 978-3-902749-04-8 N1 - Vienna Congress on Recent Advances in Earthquake Engineering and Structural Dynamics, Vienna, Austria, Paper No. 523 13. D-A-CH Tagung ; Vienna, Austria, 29. - 30. August 2013 http://hdl.handle.net/20.500.12188/15830 (Error - Cannot Connect to Server) ER -