TY - JOUR A1 - Artmann, Gerhard A1 - Trzewik, Jürgen A1 - Ates, M. T1 - A novel method to quantify mechanical tension in cell monolayers. Trzewik, Jürgen; Ates, M., Artmann, Gerhard Michael JF - Biomedizinische Technik. 47 (2002), H. Suppl. 1. Pt. 1 Y1 - 2002 SN - 0013-5585 N1 - Druckausgabe unter 63 Z 47 vorhanden SP - 379 EP - 381 ER - TY - JOUR A1 - Maggakis-Kelemen, Christina A1 - Biselli, Manfred A1 - Artmann, Gerhard T1 - Determination of the elastic shear modulus of cultured human red blood cells JF - Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1 Y1 - 2002 SN - 0013-5585 N1 - Druckausgabe unter 63 Z 471 vorhanden SP - 106 EP - 109 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zhou-Stache, J. A1 - Buettner, R. A1 - Mittermayer, C. [u.a.] T1 - Inhibition of TNF-alpha induced cell death in HUVEC and Jurkat cells by protocatechuic acid. Zhou-Stache, J.; Buettner, R.; Artmann, Gerhard Michael; Mittermayer, C.; Bosserhoff, A. K. JF - Medical and Biological Engineering and Computing. 40 (2002), H. 6 Y1 - 2002 SN - 0140-0118 SP - 698 EP - 703 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Wang, Josepf A1 - Krause, Robin A1 - Block, Kirstin A1 - Musameh, Mustafa A1 - Mulchandani, Ashok A1 - Mulchandani, Priti A1 - Chen, Wilfred T1 - Dual amperometric-potentiometric biosensor detection system for monitoring organophosphorus neurotoxins JF - Analyica Chimica Acta. 469 (2002), H. 2 Y1 - 2002 SN - 0378-4304 SP - 197 EP - 203 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. A1 - Mourzina, Y. A1 - Schubert, J. T1 - A first step towards a microfabricated thin-film sensor array on the basis of chalcogenide glass materials JF - Sensors. 2 (2002), H. 9 Y1 - 2002 SN - 1424-8220 SP - 356 EP - 365 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Simonis, A. A1 - Krings, T. A1 - Lüth, H. A1 - Wang, J. T1 - Evaluation of a chip-based thin-film / thick-film sensor hybrid for (bio-)chemical analysis JF - Electroanalysis Y1 - 2002 SN - 1040-0397 VL - 14 IS - 13 SP - 955 EP - 958 ER - TY - JOUR A1 - Ermelenko, Y. A1 - Yoshinobu, T A1 - Mourzina, Y. A1 - Levichev, S. A1 - Furuichi, K. A1 - Vlasov, Y. A1 - Schöning, Michael Josef A1 - Iwasaki, H. T1 - Photocurable membranes for ion-selective light-addressable potentiometric sensors JF - Sensors and Actuators B. 85 (2002), H. 1-2 Y1 - 2002 SN - 0925-4005 SP - 79 EP - 85 ER - TY - JOUR A1 - Vlasov, Y. G. A1 - Mourzina, Y. G. A1 - Legin, A. V. A1 - Ermelenko, Y. E. A1 - Schubert, J. A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Solid-state thin film sensors based on chalcogenide materials prepared by planar technology and pulsed laser deposition JF - Russian Journal of Applied Chemistry. 75 (2002), H. 3 Y1 - 2002 SN - 1070-4272 SP - 351 EP - 356 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, G. A1 - Steffen, T. A1 - Wu, J. T1 - Parameter identification for cement infiltration of osteoporotic bone JF - Poromechanics II : Proceedings of the Second Biot Conference on Poromechanics Grenoble, France 26 - 28 August 2002 / ed. by J.-L. Auriault ... Y1 - 2002 SN - 90-5809-394-8 SP - 55 EP - 58 PB - Balkema CY - Lisse [u.a.] ER - TY - JOUR A1 - Ermelenko, Y. A1 - Yoshinobu, T. A1 - Mourzina, Y. A1 - Schöning, Michael Josef A1 - Vlasov, Y. A1 - Iwasaki, H. T1 - The hybrid K+/Ca2+ sensor based on laser scanned silicon transducer for multi-component analysis JF - Proceedings of ICAS 2001, IUPAC [3rd] International Congress on Analytical Sciences 2001 : August 6 - 10, 2001, Waseda University, Tokyo Y1 - 2002 N1 - International Congress on Analytical Sciences <2001, Tokyo> ; International Union of Pure and Applied Chemistry. Pure and applied chemistry ; 73,10. ; Analytical sciences ; 17.2001, special issue SP - i777 EP - i780 PB - Japan Society for Analytical Chemistry CY - Tokyo ER - TY - JOUR A1 - Schäfer, Horst A1 - Heil, Günter T1 - Modeling and Graphic Presentation of Acid–Base Titration Curves. Presentation of an Alternative Method JF - The Chemical Educator. 7 (2002), H. 6 Y1 - 2002 SN - 1430-4171 SP - 339 EP - 346 ER - TY - JOUR A1 - Mourzina, Y. A1 - Yoshinobu, T. A1 - Ermelenko, Y. A1 - Furuichi, K. A1 - Vlasov, Y. A1 - Schöning, Michael Josef A1 - Iwasaki, H. T1 - Technology of photocurable membranes for ion sensors based on laser scanned semiconductor transducer (LSST) JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 254 EP - 257 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Krause, R. A1 - Block, K. A1 - Musameh, M. A1 - Mulchandani, A. A1 - Wang, J. T1 - A dual amperometric / potentiometric FIA-based biosensor for the distinctive detection of organophosphorus pesticides JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 76 EP - 79 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Otto, R. A1 - Furuichi, K. A1 - Mourzina, Yu A1 - Ermelenko, Yu A1 - Iwasaki, I. T1 - Portable light-addressable potentiometric sensor (LAPS) for multisensor applications JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 898 EP - 901 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Keusgen, M. A1 - Jünger, M. A1 - Schöning, Michael Josef T1 - Biosensoric detection of the cysteine sulphoxide alliin JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 1175 EP - 1178 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Schmitt, G. A1 - Werner, C. A1 - Schöning, Michael Josef T1 - Microelectrochemical efficiency evaluation of inhibitors for CO2 corrosion of carbon steel under high shear stress gradients JF - Corrosion 2002. Conference Proceedings. NACExpo, 57th Annual Conference and Exhibition, Denver, US, Apr 7-11, 2002 Y1 - 2002 N1 - Paper 02280 SP - 1 EP - 11 PB - NACE International CY - Houston, Texas ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Cesari, V. A1 - De Nardo, L. A1 - Colautti, P. T1 - First microdosimetric measurements with a 10b-loaded TEPC JF - Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2001 (2002) Y1 - 2002 SN - 88-7337-002-0 N1 - LNL-INFN(REP)-182/2002 SP - 110 EP - 111 ER - TY - JOUR A1 - Heinrich, U. A1 - Blum, A. A1 - Bussmann, N. A1 - Engels, R. A1 - Kemmerling, G. A1 - Weber, S. A1 - Ziemons, Karl T1 - Statistical studies on the light output and energy resolution of small LSO single crystals with different surface treatments combined with various reflector materials JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The optimization of light output and energy resolution of scintillators is of special interest for the development of high resolution and high sensitivity PET. The aim of this work is to obtain statistically reliable results concerning optimal surface treatment of scintillation crystals and the selection of reflector material. For this purpose, raw, mechanically polished and etched LSO crystals (size 2×2×10 mm3) were combined with various reflector materials (Teflon tape, Teflon matrix, BaSO4) and exposed to a 22Na source. In order to ensure the statistical reliability of the results, groups of 10 LSO crystals each were measured for all combinations of surface treatment and reflector material. Using no reflector material the light output increased up to 551±35% by mechanical polishing the surface compared to 100±5% for raw crystals. Etching the surface increased the light output to 441±29%. The untreated crystals had an energy resolution of 24.6±4.0%. By mechanical polishing the surface it was possible to achieve an energy resolution of 13.2±0.8%, by etching of 14.8±0.7%. In combination with BaSO4 as reflector material the maximum increase of light output has been established to 932±57% for mechanically polished and 895±61% for etched crystals. The combination with BaSO4 also caused the best improvement of the energy resolution up to 11.6±0.2% for mechanically polished and 12.2±0.3% for etched crystals. Relating to the light output there was no significant statistical difference between the two surface treatments in combination with BaSO4. In contrast to this, the statistical results of the energy resolution have shown the combination of mechanical polishing and BaSO4 as the optimum. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 60 EP - 66 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system with free running ADCs JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 18 EP - 21 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Coincidence detection by digital processing of free-running sampled pulses JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns. Y1 - 2002 SN - 0168-9002 VL - 487 IS - 3 SP - 530 EP - 534 ER -