TY - JOUR A1 - Rausch, Valentin A1 - Harbrecht, Andreas A1 - Kahmann, Stephanie Lucina A1 - Fenten, Thomas A1 - Jovanovic, Nebojsa A1 - Hackl, Michael A1 - Müller, Lars P. A1 - Staat, Manfred A1 - Wegmann, Kilian T1 - Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws JF - The Journal of Hand Surgery N2 - Purpose The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model. Methods A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine. Results Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup. Conclusions Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability. Clinical relevance Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties. Y1 - 2020 U6 - https://doi.org/10.1016/j.jhsa.2020.04.010 SN - 0363-5023 VL - 45 IS - 10 SP - 987.e1 EP - 987.e8 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Direct static FEM approach to limit and shakedown analysis N2 - Safety and reliability of structures may be assessed indirectly by stress distributions. Limit and shakedown theorems are simplified but exact methods of plasticity that provide safety factors directly in the loading space. These theorems may be used for a direct definition of the limit state function for failure by plastic collapse or by inadaptation. In a FEM formulation the limit state function is obtained from a nonlinear optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error. Moreover, the direct way leads to highly effective and precise reliability analyses. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis. KW - Einspielen KW - Nichtlineare Optimierung KW - Shakedown KW - Shakedown KW - limit load KW - lower bound theorem KW - nonlinear optimization KW - reliability Y1 - 2000 ER - TY - JOUR A1 - Muschallik, Lukas A1 - Kipp, Carina Ronja A1 - Recker, Inga A1 - Bongaerts, Johannes A1 - Pohl, Martina A1 - Gelissen, Melanie A1 - Schöning, Michael Josef A1 - Selmer, Thorsten A1 - Siegert, Petra T1 - Synthesis of α-hydroxy ketones and vicinal diols with the Bacillus licheniformis DSM 13T butane-2, 3-diol dehydrogenase JF - Journal of Biotechnology N2 - The enantioselective synthesis of α-hydroxy ketones and vicinal diols is an intriguing field because of the broad applicability of these molecules. Although, butandiol dehydrogenases are known to play a key role in the production of 2,3-butandiol, their potential as biocatalysts is still not well studied. Here, we investigate the biocatalytic properties of the meso-butanediol dehydrogenase from Bacillus licheniformis DSM 13T (BlBDH). The encoding gene was cloned with an N-terminal StrepII-tag and recombinantly overexpressed in E. coli. BlBDH is highly active towards several non-physiological diketones and α-hydroxyketones with varying aliphatic chain lengths or even containing phenyl moieties. By adjusting the reaction parameters in biotransformations the formation of either the α-hydroxyketone intermediate or the diol can be controlled. Y1 - 2020 SN - 2590-1559 U6 - https://doi.org/10.1016/j.jbiotec.2020.09.016 VL - 202 IS - Vol. 324 SP - 61 EP - 70 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hunker, Jan L. A1 - Gossmann, Matthias A1 - Raman, Aravind Hariharan A1 - Linder, Peter T1 - Artificial neural networks in cardiac safety assessment: Classification of chemotherapeutic compound effects on hiPSC-derived cardiomyocyte contractility JF - Journal of Pharmacological and Toxicological Methods Y1 - 2021 U6 - https://doi.org/10.1016/j.vascn.2021.107044 SN - 1056-8719 VL - 111 IS - Article number 107044 PB - Elsevier CY - New York ER - TY - BOOK A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül A1 - Zhubanova, Azhar A. A1 - Digel, Ilya ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Biological, physical and technical basics of cell engineering Y1 - 2018 SN - 978-981-10-7903-0 PB - Springer CY - Singapore ER - TY - JOUR A1 - Staat, Manfred T1 - Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels N2 - Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions. KW - Finite-Elemente-Methode KW - Grenzwertberechnung KW - Axialbelastung KW - FEM KW - Grenzwertberechnung KW - Axialbelastung KW - Traglastanalyse KW - Limit analysis KW - Global and local collapse KW - Axially cracked pipe KW - Pressure loaded crack-face Y1 - 2005 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred A1 - Kreißig, R. T1 - Finite element shakedown and limit reliability analysis of thin shells N2 - A procedure for the evaluation of the failure probability of elastic-plastic thin shell structures is presented. The procedure involves a deterministic limit and shakedown analysis for each probabilistic iteration which is based on the kinematical approach and the use the exact Ilyushin yield surface. Based on a direct definition of the limit state function, the non-linear problems may be efficiently solved by using the First and Second Order Reliabiblity Methods (Form/SORM). This direct approach reduces considerably the necessary knowledge of uncertain technological input data, computing costs and the numerical error. In: Computational plasticity / ed. by Eugenio Onate. Dordrecht: Springer 2007. VII, 265 S. (Computational Methods in Applied Sciences ; 7) (COMPLAS IX. Part 1 . International Center for Numerical Methods in Engineering (CIMNE)). ISBN 978-1-402-06576-7 S. 186-189 KW - Finite-Elemente-Methode KW - Limit analysis KW - shakedown analysis KW - Exact Ilyushin yield surface KW - Random variable KW - First Order Reliabiblity Method Y1 - 2007 ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels N2 - Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2004 ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Staat, Manfred ED - Onate, E. T1 - A face-based smoothed finite element method for hyperelastic models and tissue growth T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20-25, 2014, Barcelona Y1 - 2014 SP - 1 EP - 12 ER - TY - CHAP A1 - Staat, Manfred T1 - Design by Analysis of Pressure Components by non-linear Optimization N2 - This paper presents the direct route to Design by Analysis (DBA) of the new European pressure vessel standard in the language of limit and shakedown analysis (LISA). This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for some examples from the DBA-Manual. One observation from the examples is, that the optimisation approach gives reliable and close lower bound solutions leading to simple and optimised design decision. KW - Analytischer Zulaessigkeitsnachweis KW - FEM KW - Einspiel-Analyse KW - design-by-analysis KW - finite element analysis KW - limit and shakedown analysis Y1 - 2003 ER - TY - JOUR A1 - Staat, Manfred A1 - Schwartz, M. A1 - Lang, H. A1 - Wirtz, K. A1 - Heitzer, M. T1 - Design by Analysis of Pressure Components by non-linear Optimization JF - The 10th International Conference on Pressure Vessel Technology, July 7-10, 2003, Vienna, Austria, Proceedings ICPVT-10 / Zeman, J. L. [ed] Y1 - 2003 SN - 3950152814 SP - 59 EP - 65 PB - ÖGS, Österreichische Gesellschaft für Schweißtechnik CY - Wien ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis with Uncertain Data JF - Stochastic optimization techniques : numerical methods and technical applications / Marti, K. [ed] Y1 - 2002 SN - 3-540-42889-5 SP - 241 EP - 254 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Jablonski, Melanie A1 - Münstermann, Felix A1 - Nork, Jasmina A1 - Molinnus, Denise A1 - Muschallik, Lukas A1 - Bongaerts, Johannes A1 - Wagner, Torsten A1 - Keusgen, Michael A1 - Siegert, Petra A1 - Schöning, Michael Josef T1 - Capacitive field‐effect biosensor applied for the detection of acetoin in alcoholic beverages and fermentation broths JF - physica status solidi (a) applications and materials science N2 - An acetoin biosensor based on a capacitive electrolyte–insulator–semiconductor (EIS) structure modified with the enzyme acetoin reductase, also known as butane-2,3-diol dehydrogenase (Bacillus clausii DSM 8716ᵀ), is applied for acetoin detection in beer, red wine, and fermentation broth samples for the first time. The EIS sensor consists of an Al/p-Si/SiO₂/Ta₂O₅ layer structure with immobilized acetoin reductase on top of the Ta₂O₅ transducer layer by means of crosslinking via glutaraldehyde. The unmodified and enzyme-modified sensors are electrochemically characterized by means of leakage current, capacitance–voltage, and constant capacitance methods, respectively. KW - acetoin KW - acetoin reductase KW - alcoholic beverages KW - biosensors KW - capacitive field-effect sensors Y1 - 2021 U6 - https://doi.org/10.1002/pssa.202000765 SN - 1862-6319 N1 - Corresponding author: Melanie Jablonski VL - 218 IS - 13 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Büldt, Georg A1 - Zaccai, Guiseppe A1 - Artmann, Gerhard T1 - Dynamics and interactions of hemoglobin in red blood cells JF - Tissue Engineering Part A. 14 (2008), H. 5 Y1 - 2008 SN - 1937-3341 N1 - TERMIS EU 2008 Porto Meeting June 22–26, 2008 Porto Congress Center–Alfândega Portugal SP - 724 EP - 724 ER - TY - JOUR A1 - Staat, Manfred A1 - Baroud, G. A1 - Topcu, M. A1 - Sponagel, Stefan T1 - Soft Materials in Technology and Biology – Characteristics, Properties, and Parameter Identification JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 253 EP - 315 PB - Springer CY - Berlin ER - TY - JOUR A1 - Akimbekov, Nuraly S. A1 - Digel, Ilya A1 - Tastambek, K. T. A1 - Zhubanova, A. A. T1 - Biocompatibility of carbonized rice husk with a rat heart cells line H9c2 JF - Experimental Biology Y1 - 2013 SN - 1563-0218 N1 - Original in russischer Sprache VL - 59 IS - 3/1 SP - 23 EP - 25 ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Staat, Manfred T1 - A computational study of organ relocation after laparoscopic pectopexy to repair posthysterectomy vaginal vault prolapse JF - Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization Y1 - 2019 U6 - https://doi.org/10.1080/21681163.2019.1670095 SN - 2168-1171 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Stresses produced by different textile mesh implants in a tissue equivalent JF - BioNanoMaterials N2 - Two single-incision mini-slings used for treating urinary incontinence in women are compared with respect to the stresses they produce in their surrounding tissue. In an earlier paper we experimentally observed that these implants produce considerably different stress distributions in a muscle tissue equivalent. Here we perform 2D finite element analyses to compare the shear stresses and normal stresses in the tissue equivalent for the two meshes and to investigate their failure behavior. The results clearly show that the Gynecare TVT fails for increasing loads in a zipper-like manner because it gradually debonds from the surrounding tissue. Contrary to that, the tissue at the ends of the DynaMesh-SIS direct may rupture but only at higher loads. The simulation results are in good agreement with the experimental observations thus the computational model helps to interpret the experimental results and provides a tool for qualitative evaluation of mesh implants. Y1 - 2014 U6 - https://doi.org/10.1515/bnm-2014-0003 SN - 2191-4672 (E-Journal); 2193-066X (E-Journal); 0011-8656 (Print); 1616-0177 (Print); 2193-0651 (Print) VL - 15 IS - 1-2 SP - 25 EP - 30 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Vu, Duc Khoi A1 - Staat, Manfred A1 - Tran, Ich Thinh T1 - Analysis of pressure equipment by application of the primal-dual theory of shakedown JF - Communications in Numerical Methods in Engineering. 23 (2007), H. 3 Y1 - 2007 SN - 1069-8299 SP - 213 EP - 225 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Khoi Duc T1 - Limit loads of circumferentially flawed pipes and cylindrical vessels under internal pressure JF - International Journal of Pressure Vessels and Piping. 83 (2006), H. 3 Y1 - 2006 SN - 0308-0161 SP - 188 EP - 196 ER -