TY - JOUR A1 - Horstmann, Marie-Therese A1 - Bialonski, Stephan A1 - Noenning, Nina A1 - Mai, Heinke A1 - Prusseit, Jens A1 - Wellmer, Jörg A1 - Hinrichs, Hermann A1 - Lehnertz, Klaus T1 - State dependent properties of epileptic brain networks: Comparative graph–theoretical analyses of simultaneously recorded EEG and MEG JF - Clinical Neurophysiology N2 - Objective To investigate whether functional brain networks of epilepsy patients treated with antiepileptic medication differ from networks of healthy controls even during the seizure-free interval. Methods We applied different rules to construct binary and weighted networks from EEG and MEG data recorded under a resting-state eyes-open and eyes-closed condition from 21 epilepsy patients and 23 healthy controls. The average shortest path length and the clustering coefficient served as global statistical network characteristics. Results Independent on the behavioral condition, epileptic brains exhibited a more regular functional network structure. Similarly, the eyes-closed condition was characterized by a more regular functional network structure in both groups. The amount of network reorganization due to behavioral state changes was similar in both groups. Consistent findings could be achieved for networks derived from EEG but hardly from MEG recordings, and network construction rules had a rather strong impact on our findings. Conclusions Despite the locality of the investigated processes epileptic brain networks differ in their global characteristics from non-epileptic brain networks. Further methodological developments are necessary to improve the characterization of disturbed and normal functional networks. Significance An increased regularity and a diminished modulation capability appear characteristic of epileptic brain networks. Y1 - 2010 U6 - https://doi.org/10.1016/j.clinph.2009.10.013 SN - 1388-2457 VL - 121 IS - 2 SP - 172 EP - 185 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Knackstedt, Ralf A1 - Eggert, Mathias A1 - Gräwe, Lena A1 - Spittka, Jan T1 - Forschungsportal für Rechtsinformatik und Informationsrecht - Weg zu einer disziplinenübergreifenden Forschungsübersicht JF - MMR - Multimedia und Recht N2 - Die Entwicklungen der Rechtsinformatik und des Informationsrechts zeigen, dass diese Disziplinen aktuell vor der Herausforderung stehen, eine interdisziplinäre Zusammenarbeit zwischen ihnen und anderen Disziplinen zu etablieren. Unterschiedliche Publikationskulturen erschweren die Erreichung dieses Ziels. Forschungsportale stellen themenspezifische, internetbasierte Verzeichnisse dar, die bereits vorhandene Informationen strukturiert zugänglich machen. Sie können die Beziehungen zwischen den Disziplinen fördern, indem sie bereits erzielte Arbeitsergebnisse disziplinenübergreifend bekannt machen und dadurch dazu beitragen, Synergiepotenziale und mögliche Kooperationspartner zu identifizieren. Y1 - 2010 SN - 1434-596X IS - 8 SP - 528 EP - 533 PB - Beck CY - München ER - TY - JOUR A1 - Kroll-Ludwigs, Kathrin T1 - Die Zukunft des verbraucherschützenden Widerrufsrechts in Europa JF - Zeitschrift für europäisches Privatrecht : ZEuP N2 - Das verbraucherschützende Widerrufsrecht ist in die Jahre gekommen. Als Ergebnis der zunehmenden Rechtszersplitterung im europäischen Richtlinienrecht hat sich eine unüberschaubare Bandbreite an Ausgestaltungsformen in den mitgliedstaatlichen Rechtssystemen herausgebildet. Effektivitätseinbußen, Wettbewerbsverzerrungen und ein hohes Maß an Rechtsunsicherheit sind die Folgen. Zurückführen lässt sich die kostenintensive Fragmentierung des Verbrauchervertragsrechts auf die bisherige Regelungspolitik der Mindestharmonisierung, die es den Mitgliedstaaten erlaubt, von dem durch die Richtlinien gesetzten Mindeststandard durch „überschießende Umsetzung” abzuweichen. Der Unionsgesetzgeber versucht dem vermehrt durch einen Prozess der Vollharmonisierung zu begegnen: Neben Reformen der Richtlinie über Verbraucherkredite (VerbrKrRL) sowie der Timesharing-Richtlinie (TimesharingRL), liegt seit dem 8. Oktober 2008 nunmehr auch der Entwurf einer Rahmenrichtlinie über die Rechte der Verbraucher (VRRL-E) vor. Danach sollen die bisherigen Richtlinien über Haustürgeschäfte (HaustürgeschäfteRL), Fernabsatzverträge (FARL), missbräuchliche Klauseln sowie Verbrauchsgüterkäufe vereinigt werden. Für das verbraucherschützende Widerrufsrecht ist damit zum einen die Herausbildung einheitlicher Kernelemente verbunden, zum anderen tritt es in Konkurrenz zu umfassenden Informationspflichten, die ebenfalls den Schutz des Verbrauchers vor dem unüberlegten Abschluss riskanter bzw. nachteiliger Verträge zum Ziel haben. Angesichts dieser Entwicklung stellt sich im Folgenden die Frage nach der Zukunft des unionsrechtlichen Widerrufsrechts. Von besonderer Bedeutung ist dabei die Klärung des Verhältnisses zu den verbraucherschützenden Informationspflichten. Dazu bedarf es zunächst der Herausarbeitung einheitlicher Kernelemente des Widerrufsrechts im vollharmonisierten Richtlinienrecht (II.) sowie einer Systematisierung der sekundärrechtlichen Informationspflichten im Anschluss eine kritische Gegenüberstellung der Vor- und Nachteile beider Schutzinstrumente erfolgen kann (IV.). Y1 - 2010 SN - 0943-3929 VL - 18 IS - 3 SP - 509 EP - 534 PB - Beck CY - München ER - TY - JOUR A1 - Esch, Thomas T1 - Trends in commercial vehicle powertrains JF - ATZautotechnology N2 - Low emission zones and truck bans, the rising price of diesel and increases in road tolls: all of these factors are putting serious pressure on the transport industry. Commercial vehicle manufacturers and their suppliers are in the process of identifying new solutions to these challenges as part of their efforts to meet the EEV (enhanced environmentally friendly vehicle) limits, which are currently the most robust European exhaust and emissions standards for trucks and buses. KW - European Transient Cycle KW - Common Rail Injection System KW - Commercial Vehicle KW - Selective Catalytic Reduction KW - Diesel Engine Y1 - 2010 U6 - https://doi.org/10.1007/BF03247185 SN - 2192-886X VL - 2010 IS - 10 SP - 26 EP - 31 PB - Vieweg & Sohn CY - Wiesbaden ER - TY - JOUR A1 - Nabil, F. A1 - Peterson, Leif Arne A1 - Schmidt, A. A1 - Geerdes, D. T1 - Die Holzkuppel des Neuen Palais in Potsdam JF - Bauingenieur Y1 - 2010 SN - 0005-6650 VL - 85 IS - 8 SP - 324 EP - 330 PB - Springer-VDI-Verlag CY - Düsseldorf ER - TY - JOUR A1 - Becker, Meike A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Krombach, Gabriele A. A1 - Kremer, Ute A1 - Koppers, Benedikt A1 - Butenweg, Christoph A1 - Goemmel, Andreas A1 - Utting, Jane F. A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T JF - European Radiology N2 - Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders KW - Magnetic resonance imaging (MRI) KW - MR-stethoscope KW - Magnetic field strength KW - Left ventriular function KW - Cardiovascular MRI Y1 - 2010 U6 - https://doi.org/10.1007/s00330-009-1676-z SN - 1432-1084 (Onlineausgabe) SN - 0938-7994 (Druckausgabe) VL - 20 SP - 1344 EP - 1355 PB - Springer CY - Berlin ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - de Geyer d'Orth, Thibaut A1 - Dieringer, Matthias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Prothmann, Marcel A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla JF - Journal of Cardiovascular Magnetic Resonance N2 - Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T. KW - Interval Time Series KW - Image Quality Score KW - Image Quality Assessment KW - Sound Pressure Level KW - Cardiovascular Magnetic Resonance Y1 - 2010 U6 - https://doi.org/10.1186/1532-429X-12-67 SN - 1532-429X VL - 12 IS - 1 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Frauenrath, Tobias A1 - Prothmann, Marcel A1 - Dieringer, Matthias A. A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - Kretschel, Kerstin A1 - Niendorf, Thoralf A1 - Schulz-Menger, Jeanette T1 - Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study N2 - Objectives Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. Methods A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. Results All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. Conclusions This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T. Y1 - 2010 U6 - https://doi.org/10.1007/s00330-010-1888-2 SN - 0938-7994 VL - 20 SP - 2844 EP - 2852 PB - Springer CY - Berlin, Heidelberg ER -