TY - JOUR A1 - Behbahani, Mehdi A1 - Tran, L. A1 - Waluga, C. A1 - Behr, M. A1 - Oedekoven, B. A1 - Mottaghy, K. T1 - Model-based Numerical Analysis of Platelet Adhesion, Thrombus Growth and Aggregation for Assist Devices JF - The International Journal of Artificial Organs. 32 (2009), H. 7 Y1 - 2009 SN - 0391-3988 N1 - Abstracts - Oral Presentations: XXXVI Annual ESAO Congress, 2-5 September 2009, Compiègne - France; European Society of Artificial Organs (ESAO), Compiegne, France, September 2-5, 2009 SP - 398 EP - 398 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Bauer, S. M. A1 - Zamuraev, L. A. T1 - Model of the transversely isotropic spherical layer for estimation of intraocular pressure changes after intravitreal injections / Bauer, S. M. ; Zamuraev, L. A. ; Kotliar, K. E. JF - Rossiiskii zhurnal biomekhaniki = Russian Journal of biomechanics. 10 (2006), H. 2 Y1 - 2006 SN - 1812-5123 SP - 41 EP - 47 PB - - ER - TY - CHAP A1 - Carzana, Livio A1 - Dachwald, Bernd A1 - Noomen, Ron T1 - Model and trajectory optimization for an ideal laser-enhanced solar sail T2 - 68th International Astronautical Congress N2 - A laser-enhanced solar sail is a solar sail that is not solely propelled by solar radiation but additionally by a laser beam that illuminates the sail. This way, the propulsive acceleration of the sail results from the combined action of the solar and the laser radiation pressure onto the sail. The potential source of the laser beam is a laser satellite that coverts solar power (in the inner solar system) or nuclear power (in the outer solar system) into laser power. Such a laser satellite (or many of them) can orbit anywhere in the solar system and its optimal orbit (or their optimal orbits) for a given mission is a subject for future research. This contribution provides the model for an ideal laser-enhanced solar sail and investigates how a laser can enhance the thrusting capability of such a sail. The term ”ideal” means that the solar sail is assumed to be perfectly reflecting and that the laser beam is assumed to have a constant areal power density over the whole sail area. Since a laser beam has a limited divergence, it can provide radiation pressure at much larger solar distances and increase the radiation pressure force into the desired direction. Therefore, laser-enhanced solar sails may make missions feasible, that would otherwise have prohibitively long flight times, e.g. rendezvous missions in the outer solar system. This contribution will also analyze exemplary mission scenarios and present optimial trajectories without laying too much emphasis on the design and operations of the laser satellites. If the mission studies conclude that laser-enhanced solar sails would have advantages with respect to ”traditional” solar sails, a detailed study of the laser satellites and the whole system architecture would be the second next step Y1 - 2017 N1 - 68th International Astronautical Congress: Unlocking Imagination, Fostering Innovation and Strengthening Security, IAC 2017, 2017-09-25 → 2017-09-29, Adelaide, Australia ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, I. M. T1 - Mit Statistik gemeistert: perfekte Augentropfen und idealer Screeningtest : Möglichkeiten und Grenzen statistischer Methoden beim Glaukom JF - Der Ophthalmologe: Zeitschrift Der Deutschen Ophthalmologischen Gesellschaft N2 - Hintergrund Die Anwendung und das Verständnis von Statistik sind sehr wichtig für die biomedizinische Forschung und für die klinische Praxis. Dies gilt insbesondere auch zur Abschätzung der Möglichkeiten unterschiedlichster Diagnostik- und Therapieoptionen beim Glaukom. Die scheinbare Komplexität der Statistik, die zum Teil dem „gesunden Menschenverstand“ zu widersprechen scheint, zusammen mit der nur vorsichtigen Akzeptanz der Statistik bei vielen Medizinern können zu bewussten und unbewussten Manipulationen bei der Datendarstellung und -interpretation führen. Ziel der Arbeit Ziel ist die verständliche Darstellung einiger typischer Fehler in der medizinisch-statistischen Datenbehandlung. Material und Methoden Anhand hypothetischer Beispiele aus der Glaukomdiagnostik erfolgen die Darstellung der Wirkung eines hypotensiven Medikamentes sowie die Beurteilung der Ergebnisse eines diagnostischen Tests. Es werden die typischsten statistischen Einsatzbereiche und Irrtumsquellen ausführlich und verständlich analysiert Ergebnisse Mechanismen von Datenmanipulation und falscher Dateninterpretation werden aufgeklärt. Typische Irrtumsquellen bei der statistischen Auswertung und Datendarstellung werden dabei erläutert. Schlussfolgerungen Die erläuterten praktischen Beispiele zeigen die Notwendigkeit, die Grundlagen der Statistik zu verstehen und korrekt anwenden zu können. Fehlendes Grundlagenwissen und Halbwissen der medizinischen Statistik können zu folgenschweren Missverständnissen und falschen Entscheidungen in der medizinischen Forschung, aber auch in der klinischen Praxis führen. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00347-016-0312-y SN - 0941-293X SN - 1433-0423 N1 - Englischer Titel: Mastered with statistics: perfect eye drops and ideal screening test : possibilities and limits of statistical methods for glaucoma IS - 113 SP - 838 EP - 843 PB - Springer CY - Berlin ER - TY - CHAP A1 - Borggräfe, Andreas A1 - Dachwald, Bernd T1 - Mission performance evaluation for solar sails using a refined SRP force model with variable optical coefficients T2 - 2nd International Symposium on Solar Sailing N2 - Solar sails provide ignificant advantages over other low-thrust propulsion systems because they produce thrust by the momentum exchange from solar radiation pressure (SRP) and thus do not consume any propellant.The force exerted on a very thin sail foil basically depends on the light incidence angle. Several analytical SRP force models that describe the SRP force acting on the sail have been established since the 1970s. All the widely used models use constant optical force coefficients of the reflecting sail material. In 2006,MENGALI et al. proposed a refined SRP force model that takes into account the dependancy of the force coefficients on the light incident angle,the sail’s distance from the sun (and thus the sail emperature) and the surface roughness of the sail material [1]. In this paper, the refined SRP force model is compared to the previous ones in order to identify the potential impact of the new model on the predicted capabilities of solar sails in performing low-cost interplanetary space missions. All force models have been implemented within InTrance, a global low-thrust trajectory optimization software utilizing evolutionary neurocontrol [2]. Two interplanetary rendezvous missions, to Mercury and the near-Earth asteroid 1996FG3, are investigated. Two solar sail performances in terms of characteristic acceleration are examined for both scenarios, 0.2 mm/s2 and 0.5 mm/s2, termed “low” and “medium” sail performance. In case of the refined SRP model, three different values of surface roughness are chosen, h = 0 nm, 10 nm and 25 nm. The results show that the refined SRP force model yields shorter transfer times than the standard model. Y1 - 2010 N1 - 2nd International Symposium on Solar Sailing, ISSS 2010, 2010-07-20 - 2010-07-22. New York City College of Technology of the City University of New York, USA SP - 1 EP - 6 ER - TY - JOUR A1 - Maiwald, Volker A1 - Dachwald, Bernd T1 - Mission Design for a Multiple-Rendezvous Mission to Jupiter's Trojans Y1 - 2010 N1 - COSPAR 2010 ; 38th COSPAR Scientific Assembly. Held 18-25 July 2010 in Bremen, Germany [Abstract] SP - 3 ER - TY - CHAP A1 - Dachwald, Bernd A1 - Wurm, P. T1 - Mission analysis for an advanced solar photon thruster T2 - 60th International Astronautical Congress 2009, IAC 2009 N2 - The so-called "compound solar sail", also known as "Solar Photon Thruster" (SPT), is a solar sail design concept, for which the two basic functions of the solar sail, namely light collection and thrust direction, are uncoupled. In this paper, we introduce a novel SPT concept, termed the Advanced Solar Photon Thruster (ASPT). This model does not suffer from the simplified assumptions that have been made for the analysis of compound solar sails in previous studies. We present the equations that describe the force, which acts on the ASPT. After a detailed design analysis, the performance of the ASPT with respect to the conventional flat solar sail (FSS) is investigated for three interplanetary mission scenarios: An Earth-Venus rendezvous, where the solar sail has to spiral towards the Sun, an Earth-Mars rendezvous, where the solar sail has to spiral away from the Sun, and an Earth-NEA rendezvous (to near-Earth asteroid 1996FG3), where a large orbital eccentricity change is required. The investigated solar sails have realistic near-term characteristic accelerations between 0.1 and 0.2mm/s2. Our results show that a SPT is not superior to the flat solar sail unless very idealistic assumptions are made. KW - Interplanetary flight Y1 - 2009 SN - 978-161567908-9 N1 - 60th International Astronautical Congress 2009, IAC 2009; Daejeon; South Korea; 12 October 2009 through 16 October 2009 VL - Vol. 8 SP - 6838 EP - 6851 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dachwald, Bernd A1 - Wurm, Patrick T1 - Mission analysis and performance comparison for an Advanced Solar Photon Thruster JF - Advances in Space Research Y1 - 2011 SN - 0273-1177 VL - 48 IS - 11 SP - 1858 EP - 1868 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dachwald, Bernd T1 - Minimum Transfer Times for Nonperfectly Reflecting Solar Sailcraft JF - Journal of Spacecraft and Rockets. 41 (2004), H. 4 Y1 - 2004 SN - 0022-4650 N1 - 2. ISSN: 1533-6794 SP - 693 EP - 695 ER - TY - JOUR A1 - Steinseifer, Ulrich A1 - Kashefi, Ali A1 - Hormes, Marcus A1 - Schoberer, Mark A1 - Orlikowsky, Thorsten A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Schmitz-Rode, Thomas T1 - Miniaturization of ECMO Systems : Engineering Challenges and Methods JF - Artificial Organs. 33 (2009), H. 5 Y1 - 2009 SN - 1525-1594 N1 - Fifth International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion Abstracts SP - A55 EP - A55 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Seidova, Seid-Fatima A1 - Lanzl, Ines T1 - Microstructural alterations of retinal arterial blood column along the vessel axis in systemic hypertension JF - Investigative Ophthalmology & Visual Science, IOVS N2 - Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension. Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530–600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation. Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05). Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation. Y1 - 2010 U6 - http://dx.doi.org/10.1167/iovs.09-3649 SN - 0146-0404 VL - 51 IS - 4 SP - 2165 EP - 2172 PB - ARVO CY - Rockville, Md. ER - TY - CHAP A1 - Digel, Ilya A1 - Akimbekov, Nuraly Sh. A1 - Kistaubayeva, Aida A1 - Zhubanova, Azhar A. ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Microbial Sampling from Dry Surfaces: Current Challenges and Solutions T2 - Biological, Physical and Technical Basics of Cell Engineering N2 - Sampling of dry surfaces for microorganisms is a main component of microbiological safety and is of critical importance in many fields including epidemiology, astrobiology as well as numerous branches of medical and food manufacturing. Aspects of biofilm formation, analysis and removal in aqueous solutions have been thoroughly discussed in literature. In contrast, microbial communities on air-exposed (dry) surfaces have received significantly less attention. Diverse surface sampling methods have been developed in order to address various surfaces and microbial groups, but they notoriously show poor repeatability, low recovery rates and suffer from lack of mutual consistency. Quantitative sampling for viable microorganisms represents a particular challenge, especially on porous and irregular surfaces. Therefore, it is essential to examine in depth the factors involved in microorganisms’ recovery efficiency and accuracy depending on the sampling technique used. Microbial colonization, retention and community composition on different dry surfaces are very complex and rely on numerous physicochemical and biological factors. This study is devoted to analyze and review the (a) physical phenomena and intermolecular forces relevant for microbiological surface sampling; (b) challenges and problems faced by existing sampling methods for viable microorganisms and (c) current directions of engineering and research aimed at improvement of quality and efficiency of microbiological surface sampling. KW - Sampling methods KW - Surface microorganisms KW - Dry surfaces KW - Microbial adhesion KW - Swabbing Y1 - 2018 SN - 978-981-10-7904-7 U6 - http://dx.doi.org/10.1007/978-981-10-7904-7_19 SP - 421 EP - 456 PB - Springer CY - Singapore ER - TY - JOUR A1 - Campen, R. A1 - Kowalski, Julia A1 - Lyons, W.B. A1 - Tulaczyk, S. A1 - Dachwald, Bernd A1 - Pettit, E. A1 - Welch, K. A. A1 - Mikucki, J.A. T1 - Microbial diversity of an Antarctic subglacial community and high‐resolution replicate sampling inform hydrological connectivity in a polar desert JF - Environmental Microbiology Y1 - 2019 U6 - http://dx.doi.org/10.1111/1462-2920.14607 SN - 1462-2920 IS - accepted article PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Finocchiaro, Thomas A1 - Heinke, Stefanie A1 - Leßmann, Marc T1 - Methods of design, simulation, and control for the development of new VAD/TAH concepts = Methoden zur Konstruktion, Simulation und Regelung für die Entwicklung von neuen VAD/TAH-Konzepten / Finocchiaro, Thomas ; Heinke, Stefanie ; Behbahani, Mehdi ; Leßma JF - Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5 Y1 - 2009 SN - 0013-5585 N1 - Printausgabe in der Bereichsbibliothek Jülich vorhanden : 63 Z 471 SP - 269 EP - 281 ER - TY - JOUR A1 - Nurispahic, A. A1 - Kotliar, Konstantin A1 - Lanzl, I. T1 - Messung der Akkommodation mittels optischer Biometrie JF - Der Ophthalmologe Y1 - 2008 SN - 1433-0423 VL - 105 IS - 4 SP - 369 EP - 375 PB - - ER - TY - JOUR A1 - Martin-Gonzalez, Anabel A1 - Kotliar, Konstantin A1 - Rios-Martinez, Jorge A1 - Lanzl, Ines A1 - Navab, Nassir T1 - Mediated-reality magnification for macular degeneration rehabilitation JF - Journal of Modern Optics Y1 - 2014 U6 - http://dx.doi.org/10.1080/09500340.2014.936110 SN - 1362-3044 VL - 61 IS - 17 SP - 1400 EP - 1408 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Werkhausen, Amelie A1 - Willwacher, Steffen A1 - Albracht, Kirsten T1 - Medial gastrocnemius muscle fascicles shorten throughout stance during sprint acceleration JF - Scandinavian Journal of Medicine & Science in Sports N2 - The compliant nature of distal limb muscle-tendon units is traditionally considered suboptimal in explosive movements when positive joint work is required. However, during accelerative running, ankle joint net mechanical work is positive. Therefore, this study aims to investigate how plantar flexor muscle-tendon behavior is modulated during fast accelerations. Eleven female sprinters performed maximum sprint accelerations from starting blocks, while gastrocnemius muscle fascicle lengths were estimated using ultrasonography. We combined motion analysis and ground reaction force measurements to assess lower limb joint kinematics and kinetics, and to estimate gastrocnemius muscle-tendon unit length during the first two acceleration steps. Outcome variables were resampled to the stance phase and averaged across three to five trials. Relevant scalars were extracted and analyzed using one-sample and two-sample t-tests, and vector trajectories were compared using statistical parametric mapping. We found that an uncoupling of muscle fascicle behavior from muscle-tendon unit behavior is effectively used to produce net positive mechanical work at the joint during maximum sprint acceleration. Muscle fascicles shortened throughout the first and second steps, while shortening occurred earlier during the first step, where negative joint work was lower compared with the second step. Elastic strain energy may be stored during dorsiflexion after touchdown since fascicles did not lengthen at the same time to dissipate energy. Thus, net positive work generation is accommodated by the reuse of elastic strain energy along with positive gastrocnemius fascicle work. Our results show a mechanism of how muscles with high in-series compliance can contribute to net positive joint work. KW - locomotion KW - muscle mechanics KW - running KW - sprint start KW - ultrasonography Y1 - 2021 U6 - http://dx.doi.org/10.1111/sms.13956 SN - 0905-7188 (Druckausgabe) SN - 1600-0838 (Onlineausgabe) VL - 31 IS - 7 SP - 1471 EP - 1480 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Becker, C. A1 - Wallang, C. A1 - Artmann, Gerhard A1 - Jakse, G. T1 - Mechanotransduction-bioreactor for tissue engineering of a ureter prosthesis JF - International Journal of Artificial Organs, The Y1 - 2008 SN - 0391-3988 N1 - Abstracts from the XXXV Congress of the European Society for Artificial Organs: 'Towards Future Biomedical Technologies' - ORAL PRESENTATIONS VL - 31 IS - 7 SP - 583 EP - 583 ER - TY - JOUR A1 - Bayer, Robin A1 - Temiz Artmann, Aysegül A1 - Digel, Ilya A1 - Falkenstein, Julia A1 - Artmann, Gerhard A1 - Creutz, Till A1 - Hescheler, Jürgen T1 - Mechano-pharmacological testing of L-Type Ca²⁺ channel modulators via human vascular celldrum model JF - Cellular Physiology and Biochemistry N2 - Background/Aims: This study aimed to establish a precise and well-defined working model, assessing pharmaceutical effects on vascular smooth muscle cell monolayer in-vitro. It describes various analysis techniques to determine the most suitable to measure the biomechanical impact of vasoactive agents by using CellDrum technology. Methods: The so-called CellDrum technology was applied to analyse the biomechanical properties of confluent human aorta muscle cells (haSMC) in monolayer. The cell generated tensions deviations in the range of a few N/m² are evaluated by the CellDrum technology. This study focuses on the dilative and contractive effects of L-type Ca²⁺ channel agonists and antagonists, respectively. We analyzed the effects of Bay K8644, nifedipine and verapamil. Three different measurement modes were developed and applied to determine the most appropriate analysis technique for the study purpose. These three operation modes are called, particular time mode" (PTM), "long term mode" (LTM) and "real-time mode" (RTM). Results: It was possible to quantify the biomechanical response of haSMCs to the addition of vasoactive agents using CellDrum technology. Due to the supplementation of 100nM Bay K8644, the tension increased approximately 10.6% from initial tension maximum, whereas, the treatment with nifedipine and verapamil caused a significant decrease in cellular tension: 10nM nifedipine decreased the biomechanical stress around 6,5% and 50nM verapamil by 2,8%, compared to the initial tension maximum. Additionally, all tested measurement modes provide similar results while focusing on different analysis parameters. Conclusion: The CellDrum technology allows highly sensitive biomechanical stress measurements of cultured haSMC monolayers. The mechanical stress responses evoked by the application of vasoactive calcium channel modulators were quantified functionally (N/m²). All tested operation modes resulted in equal findings, whereas each mode features operation-related data analysis. Y1 - 2020 U6 - http://dx.doi.org/10.33594/000000225 SN - 1421-9778 VL - 54 SP - 371 EP - 383 PB - Cell Physiol Biochem Press CY - Düsseldorf ER - TY - JOUR A1 - Goßmann, Matthias A1 - Frotscher, Ralf A1 - Linder, Peter A1 - Bayer, Robin A1 - Epple, U. A1 - Staat, Manfred A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Mechano-pharmacological characterization of cardiomyocytes derived from human induced pluripotent stem cells JF - Cellular physiology and biochemistry N2 - Background/Aims: Common systems for the quantification of cellular contraction rely on animal-based models, complex experimental setups or indirect approaches. The herein presented CellDrum technology for testing mechanical tension of cellular monolayers and thin tissue constructs has the potential to scale-up mechanical testing towards medium-throughput analyses. Using hiPS-Cardiac Myocytes (hiPS-CMs) it represents a new perspective of drug testing and brings us closer to personalized drug medication. Methods: In the present study, monolayers of self-beating hiPS-CMs were grown on ultra-thin circular silicone membranes and deflect under the weight of the culture medium. Rhythmic contractions of the hiPS-CMs induced variations of the membrane deflection. The recorded contraction-relaxation-cycles were analyzed with respect to their amplitudes, durations, time integrals and frequencies. Besides unstimulated force and tensile stress, we investigated the effects of agonists and antagonists acting on Ca²⁺ channels (S-Bay K8644/verapamil) and Na⁺ channels (veratridine/lidocaine). Results: The measured data and simulations for pharmacologically unstimulated contraction resembled findings in native human heart tissue, while the pharmacological dose-response curves were highly accurate and consistent with reference data. Conclusion: We conclude that the combination of the CellDrum with hiPS-CMs offers a fast, facile and precise system for pharmacological, toxicological studies and offers new preclinical basic research potential. KW - Inotropic compounds KW - Pharmacology KW - Ion channels KW - CellDrum KW - Heart tissue culture KW - Induced pluripotent stem cells KW - Cardiac myocytes Y1 - 2016 U6 - http://dx.doi.org/10.1159/000443124 SN - 1421-9778 (Online) SN - 1015-8987 (Print) VL - 38 IS - 3 SP - 1182 EP - 1198 PB - Karger CY - Basel ER -