TY - JOUR A1 - Poth, Sebastian A1 - Monzon, Magaly A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Lignocellulosic biorefinery: Process integration of hydrolysis and fermentation (SSF process) JF - Holzforschung N2 - The aim of the present work is the process integration and the optimization of the enzymatic hydrolysis of wood and the following fermentation of the products to ethanol. The substrate is a fiber fraction obtained by organosolv pre-treatment of beech wood. For the ethanol production, a co-fermentation by two different yeasts (Saccharomyces cerevisiae and Pachysolen tannophilus) was carried out to convert glucose as well as xylose. Two approaches has been followed: 1. A two step process, in which the hydrolysis of the fiber fraction and the fermentation to product are separated from each other. 2. A process, in which the hydrolysis and the fermentation are carried out in one single process step as simultaneous saccharification and fermentation (SSF). Following the first approach, a yield of about 0.15 g ethanol per gram substrate can be reached. Based on the SSF, one process step can be saved, and additionally, the gained yield can be raised up to 0.3 g ethanol per gram substrate. Y1 - 2011 N1 - 11th EWLP, Hamburg, Germany, August 16–19, 2010 VL - 65 IS - 5 SP - 633 EP - 637 PB - De Gruyter CY - Berlin ER - TY - CHAP A1 - Al-Kaidy, H. A1 - Ulber, Roland A1 - Tippkötter, Nils T1 - A platform technology for the automated reaction control in magnetizable micro-fluidic droplets T2 - Biomaterials - made in bioreactors : book of abstracts, May 26 - 28, 2014, Radisson Blu Park Hotel and Conference Dentre, Radebeul, Germany Y1 - 2014 SP - 21 EP - 22 PB - DECHEMA CY - Frankfurt am Main ER - TY - JOUR A1 - Gerigk, M. A1 - Bujnicki, R. A1 - Ganpo-Nkwenkwa, E. A1 - Bongaerts, Johannes A1 - Sprenger, G. A1 - Takors, Ralf T1 - Process control for enhanced L-phenylalanine production using different recombinant Escherichia coli strains JF - Biotechnology and bioengineering Y1 - 2002 SN - 1097-0290 (E-Journal); 0006-3592 (Print) VL - Vol. 80 IS - Iss. 7 SP - 746 EP - 754 ER - TY - JOUR A1 - Bongaerts, Johannes A1 - Bovenberg, Roel A1 - Krämer, Marco A1 - Müller, Ulrike A1 - Raeven, Leon A1 - Wubbolts, Marcel T1 - Metabolic engineering to produce fine chemicals in Escherichia coli JF - Chemie - Ingenieur - Technik (CIT) Y1 - 2002 SN - 1522-2640 (E-Journal); 0009-286X (Print) N1 - Printausg. in der Bibliothek vorhanden: 63 ZS 022 VL - Vol. 74 IS - Iss. 5 SP - 694 ER - TY - JOUR A1 - Bongaerts, Johannes A1 - Zoschke, Sascha A1 - Weidner, Uwe A1 - Linden, Gottfried T1 - Transcriptional regulation of the proton translocating NADH JF - Molecular microbiology Y1 - 1995 SN - 1365-2958 (E-Journal); 0950-382x (Print) VL - Vol. 16 IS - Iss. 3 SP - 521 EP - 534 ER - TY - JOUR A1 - Monakhova, Yulia A1 - Diehl, Bernd W.K. T1 - Novel approach of qNMR workflow by standardization using 2H integral: Application to any intrinsic calibration standard JF - Talanta N2 - Quantitative nuclear magnetic resonance (qNMR) is routinely performed by the internal or external standardization. The manuscript describes a simple alternative to these common workflows by using NMR signal of another active nuclei of calibration compound. For example, for any arbitrary compound quantification by NMR can be based on the use of an indirect concentration referencing that relies on a solvent having both 1H and 2H signals. To perform high-quality quantification, the deuteration level of the utilized deuterated solvent has to be estimated. In this contribution the new method was applied to the determination of deuteration levels in different deuterated solvents (MeOD, ACN, CDCl3, acetone, benzene, DMSO-d6). Isopropanol-d6, which contains a defined number of deuterons and protons, was used for standardization. Validation characteristics (precision, accuracy, robustness) were calculated and the results showed that the method can be used in routine practice. Uncertainty budget was also evaluated. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and can be applied in different application areas (purity determination, forensics, pharmaceutical analysis, etc.). KW - qNMR KW - Deuterium NMR KW - Deuterated solvents KW - Standardization Y1 - 2021 SN - 0039-9140 U6 - https://doi.org/10.1016/j.talanta.2020.121504 VL - 222 IS - Article number: 121504 PB - Elsevier ER - TY - JOUR A1 - Monakhova, Yulia A1 - Diehl, Bernd W.K. T1 - Multinuclear NMR screening of pharmaceuticals using standardization by 2H integral of a deuterated solvent JF - Journal of Pharmaceutical and Biomedical Analysis N2 - NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products. KW - NMR spectroscopy KW - Inorganic ions KW - Heparin KW - Standardization Y1 - 2022 SN - 0731-7085 U6 - https://doi.org/10.1016/j.jpba.2021.114530 VL - 209 IS - Article number: 114530 PB - Elsevier ER - TY - JOUR A1 - Block, Franziska A1 - May, Alexander A1 - Wetzel, Katharina A1 - Adels, Klaudia A1 - Elbers, Gereon A1 - Schulze, Margit A1 - Monakhova, Yulia T1 - What is the best spectroscopic method for simultaneous analysis of organic acids and (poly)saccharides in biological matrices: Example of Aloe vera extracts? JF - Talanta Open N2 - Several species of (poly)saccharides and organic acids can be found often simultaneously in various biological matrices, e.g., fruits, plant materials, and biological fluids. The analysis of such matrices sometimes represents a challenging task. Using Aloe vera (A. vera) plant materials as an example, the performance of several spectro-scopic methods (80 MHz benchtop NMR, NIR, ATR-FTIR and UV–vis) for the simultaneous analysis of quality parameters of this plant material was compared. The determined parameters include (poly)saccharides such as aloverose, fructose and glucose as well as organic acids (malic, lactic, citric, isocitric, acetic, fumaric, benzoic and sorbic acids). 500 MHz NMR and high-performance liquid chromatography (HPLC) were used as the reference methods. UV–vis data can be used only for identification of added preservatives (benzoic and sorbic acids) and drying agent (maltodextrin) and semiquantitative analysis of malic acid. NIR and MIR spectroscopies combined with multivariate regression can deliver more informative overview of A. vera extracts being able to additionally quantify glucose, aloverose, citric, isocitric, malic, lactic acids and fructose. Low-field NMR measurements can be used for the quantification of aloverose, glucose, malic, lactic, acetic, and benzoic acids. The benchtop NMR method was successfully validated in terms of robustness, stability, precision, reproducibility and limit of detection (LOD) and quantification (LOQ), respectively. All spectroscopic techniques are useful for the screening of (poly)saccharides and organic acids in plant extracts and should be applied according to its availability as well as information and confidence required for the specific analytical goal. Benchtop NMR spectroscopy seems to be the most feasible solution for quality control of A. vera products. KW - Spectroscopy KW - (Poly)saccharides KW - Organic acids KW - Aloe vera KW - qNMR Y1 - 2023 U6 - https://doi.org/10.1016/j.talo.2023.100220 SN - 2666-8319 VL - 7 IS - Art. No. 100220 SP - 1 EP - 9 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Adels, Klaudia A1 - Elbers, Gereon A1 - Diehl, Bernd A1 - Monakhova, Yulia T1 - Multicomponent analysis of dietary supplements containing glucosamine and chondroitin: comparative low- and high-field NMR spectroscopic study JF - Analytical Sciences N2 - With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500–600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500–600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride. KW - Glucosamine KW - Chondroitin sulfate KW - Polysaccharides KW - Dietary supplements KW - High-field NMR Y1 - 2023 U6 - https://doi.org/10.1007/s44211-023-00433-2 SN - 1348-2246 (Online) SN - 0910-6340 (Print) N1 - Corresponding author: Yulia Monakhova VL - 2023 PB - Springer Verlag CY - Cham ER - TY - JOUR A1 - Trapp, Svenja A1 - Lammers, Tom A1 - Engudar, Gokce A1 - Hoehr, Cornelia A1 - Denkova, Antonia G. A1 - Paulßen, Elisabeth A1 - de Kruijff, Robin M. T1 - Membrane-based microfluidic solvent extraction of Ga-68 from aqueous Zn solutions: towards an automated cyclotron production loop JF - EJNMMI Radiopharmacy and Chemistry KW - Microfluidic solvent extraction KW - Ga-68 KW - Cyclotron production KW - Medical radionuclide production KW - Metal contaminants Y1 - 2023 U6 - https://doi.org/10.1186/s41181-023-00195-2 SN - 2365-421X VL - 2023 IS - 8, Article number: 9 SP - 1 EP - 14 PB - Springer Nature ER - TY - JOUR A1 - Monakhova, Yulia A1 - Diehl, Bernd W. K. T1 - A step towards optimization of the qNMR workflow: proficiency testing exercise at an GxP-accredited laboratory JF - Applied Magnetic Resonance N2 - Quantitative nuclear magnetic resonance (qNMR) is considered as a powerful tool for multicomponent mixture analysis as well as for the purity determination of single compounds. Special attention is currently paid to the training of operators and study directors involved in qNMR testing. To assure that only qualified personnel are used for sample preparation at our GxP-accredited laboratory, weighing test was proposed. Sixteen participants performed six-fold weighing of the binary mixture of dibutylated hydroxytoluene (BHT) and 1,2,4,5-tetrachloro-3-nitrobenzene (TCNB). To evaluate the quality of data analysis, all spectra were evaluated manually by a qNMR expert and using in-house developed automated routine. The results revealed that mean values are comparable and both evaluation approaches are free of systematic error. However, automated evaluation resulted in an approximately 20% increase in precision. The same findings were revealed for qNMR analysis of 32 compounds used in pharmaceutical industry. Weighing test by six-fold determination in binary mixtures and automated qNMR methodology can be recommended as efficient tools for evaluating staff proficiency. The automated qNMR method significantly increases throughput and precision of qNMR for routine measurements and extends application scope of qNMR. Y1 - 2021 U6 - https://doi.org/10.1007/s00723-021-01324-3 SN - 1613-7507 N1 - Corresponding author: Yulia Monakhova VL - 52 SP - 581 EP - 593 PB - Springer Nature CY - Wien ER -