TY - JOUR A1 - Ellerweg, Roland A1 - Ritz, Thomas A1 - Schuhmann, Stefan T1 - Anwendungsentwicklung für iPhone und Windows Mobile : ein bisschen von allem JF - iX : Magazin für professionelle Informationstechnik Y1 - 2009 SN - 0935-9680 (Print) SN - 1612-1392 (Online) IS - 3 SP - 132 EP - 135 ER - TY - JOUR A1 - Heuermann, Holger A1 - Schiek, Burkhard T1 - A Fast and Robust Procedure for the Determination of the Scattering Parameters for Network Analyzer Calibration Y1 - 1992 N1 - Precision electromagnetic measurements : conference Paris, 9-12 June 1992 = Conférence sur les Mesures Electromagnétiques de Précision. SP - 373 EP - 374 CY - Paris ER - TY - JOUR A1 - Ferrein, Alexander A1 - Fritz, Christian A1 - Lakemeyer, Gerhard T1 - On-Line Decision-Theoretic Golog for Unpredictable Domains / Ferrein, Alexander ; Fritz, Christian ; Lakemeyer, Gerhard JF - KI 2004: Advances in Artificial Intelligence : 27th Annual German Conference on AI, KI 2004, Ulm, Germany, September 20-24, 2004. Proceedings Y1 - 2004 N1 - Lecture Notes in Computer Science ; 3238 SP - 322 EP - 336 PB - Springer CY - Berlin ER - TY - JOUR A1 - Heuermann, Holger T1 - Selbstkalibrierverfahren zur Systemfehlerkorrektur von Streuparametermessungen auf Halbleitersubstraten JF - Mikrowellen und Optronik : Kongreßunterlagen = Microwaves and optronics / MIOP '95, 8. Kongreßmesse für Hochfrequenztechnik, Messehalle Sindelfingen, 30. Mai - 1. Juni 1995. [Hrsg.: Network GmbH] Y1 - 1995 SN - 3-924651-45-0 N1 - MIOP ; (8, 1995, Sindelfingen) SP - 23 EP - 29 CY - Hagenburg ER - TY - JOUR A1 - Heuermann, Holger A1 - Graf, W. T1 - Vergleich mehrerer Naeherungsverfahren zur Berechnung des Wellenwiderstandes von Mikrostreifenleitungen mit experimentellen Ergebnissen JF - Kleinheubacher Berichte : Vorträge und Berichte der gemeinsamen Tagung des U.R.S.I.-Landesausschusses in der Bundesrepublik Deutschland / Hrsg.: Deutsche Telekom AG. 39. 1996 (1996) Y1 - 1996 ER - TY - JOUR A1 - Heuermann, Holger A1 - Schiek, Burkhard T1 - Sichere on-wafer-Streuparameter-Messungen mit Selbstkalibrierverfahren JF - Kleinheubacher Berichte : Vorträge und Berichte der gemeinsamen Tagung des U.R.S.I.-Landesausschusses in der Bundesrepublik Deutschland / Hrsg.: Deutsche Telekom AG. 38. 1994 (1994) Y1 - 1994 SP - 611 EP - 622 ER - TY - JOUR A1 - Heuermann, Holger A1 - Emmrich, Thomas A1 - Bongartz, Simon T1 - Microwave spark plug to support ignitions with high compression ratios JF - IEEE Transactions on Plasma Science N2 - Upcoming gasoline engines should run with a larger number of fuels beginning from petrol over methanol up to gas by a wide range of compression ratios and a homogeneous charge. In this article, the microwave (MW) spark plug, based on a high-speed frequency hopping system, is introduced as a solution, which can support a nitrogen compression ratio up to 1:39 in a chamber and more. First, an overview of the high-speed frequency hopping MW ignition and operation system as well as the large number of applications are presented. Both gives an understanding of this new base technology for MW plasma generation. Focus of the theoretical part is the explanation of the internal construction of the spark plug, on the achievable of the high voltage generation as well as the high efficiency to hold the plasma. In detail, the development process starting with circuit simulations and ending with the numerical multiphysics field simulations is described. The concept is evaluated with a reference prototype covering the frequency range between 2.40 and 2.48 GHz and working over a large power range from 20 to 200 W. A larger number of different measurements starting by vector hot-S11 measurements and ending by combined working scenarios out of hot temperature, high pressure and charge motion are winding up the article. The limits for the successful pressure tests were given by the pressure chamber. Pressures ranged from 1 to 39 bar and charge motion up to 25 m/s as well as temperatures from 30◦ to 125◦. KW - Automotive application KW - ignition KW - microplasma KW - microwave (MW) plasma KW - plasma jet Y1 - 2022 U6 - https://doi.org/10.1109/TPS.2022.3183690 SN - 1939-9375 IS - Early Access SP - 1 EP - 6 PB - IEEE ER - TY - JOUR A1 - Wolf, Martin R. A1 - Armbruster, S. A1 - Schlick, Christopher A1 - Simon, S. T1 - Marktübersicht Telekooperationssysteme - Das IAW stellt im Internet umfangreiche Informationen über Telekooperationssysteme zur Verfügung / Wolf, M. ; Armbruster, S. ; Schlick, C. ; Simon, S. JF - FIR + IAW Mitteilungen. 29 (1997), H. 1 Y1 - 1997 SP - 11 EP - 12 PB - - ER - TY - JOUR A1 - Ritz, Thomas T1 - Personalized information services : an electronic information commodity and its production JF - International Journal of E-Business Strategy Management Y1 - 2000 SN - 1467-0305 VL - 2 IS - 2 ER - TY - JOUR A1 - Ferrein, Alexander A1 - Jacobs, Stefan A1 - Lakemeyer, Gerhard T1 - Unreal Golog Bots / Jacobs, Stefan ; Ferrein, Alexander ; Lakemeyer, Gerhard JF - IJCAI-05 Workshop on Reasoning, Representation, and Learning in Computer Games Y1 - 2005 SP - 31 EP - 36 ER - TY - JOUR A1 - Heuermann, Holger A1 - Schiek, B. T1 - Results of network analyzer measurements with leakage errors-corrected with direct calibration techniques JF - IEEE transactions on instrumentation and measurement : IM / Institute of Electrical and Electronics Engineers, Instrumentation and Measurement Group. 46 (1997), H. 5 Y1 - 1997 SN - 0018-9456 SP - 1120 EP - 1127 ER - TY - JOUR A1 - Ferrein, Alexander A1 - Böhnstedt, Lutz A1 - Lakemeyer, Gerhard T1 - Options in readylog reloaded -- generating decision-theoretic plan libraries in golog / Böhnstedt, Lutz ; Ferrein, Alexander ; Lakemeyer, Gerhard JF - KI 2007: advances in artificial intelligence : 30th Annual German Conference on AI, KI 2007, Osnabrück, Germany, September 10 - 13, 2007 ; proceedings Y1 - 2007 SN - 978-3-540-74564-8 N1 - Lecture Notes in Computer Science ; 4667 SP - 352 EP - 366 PB - Springer CY - Berlin ER - TY - JOUR A1 - Heuermann, Holger T1 - LZY: A Self-Calibration Approach in Competition to the LRM Method for On-Wafer Measurements Y1 - 1995 N1 - 45th ARFTG Conference digest, Spring 1995 : [conference topic: Testing and design of RFIC'S], May 19, 1995, Orange County Convention Center, Orlando, Florida / Automatic RF Techniques Group. Publications chairman: Ed Godshalk; ARFTG Conference digest ; 4 SP - 129 EP - 136 ER - TY - JOUR A1 - Heuermann, Holger A1 - Stolle, Reinhard A1 - Schiek, Burkhard T1 - Auswertemethoden zur Praezisions-Entfernungsmessung mit FMCW-Systemen und deren Anwendung im Mikrowellenbereich JF - tm - Technisches Messen. 62. 1995 (1995), H. 2 Y1 - 1995 SP - 66 EP - 73 ER - TY - JOUR A1 - Wolf, Martin R. A1 - Foltz, Christian A1 - Schlick, Christopher A1 - Luczak, Holger T1 - Development and evaluation of a groupware system to support chemical design processes / Wolf, Martin ; Foltz, Christian ; Schlick, Christopher ; Luczak, Holger JF - International Journal of Human-Computer Interaction . 14 (2002), H. 2 Y1 - 2002 SN - 1044-7318 SP - 181 EP - 198 PB - - ER - TY - JOUR A1 - Heuermann, Holger A1 - Sadeghfam, Arash T1 - Enhanced system architecture for rugged wide band data transmission / Sadeghfam, A. ; Heuermann, H. JF - European Radar Conference, 2009 : EuRAD 2009 ; Sept. 30 - Oct. 2 2009, Rome, Italy ; part of the European Microwave Week (EuMW) / sponsored by EuMA, European Microwave Association Y1 - 2009 SN - 978-2-87487-014-9 N1 - Proceedings of the 6th European Radar Conference SP - 347 EP - 350 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Frauenrath, Tobias A1 - Prothmann, Marcel A1 - Dieringer, Matthias A. A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - Kretschel, Kerstin A1 - Niendorf, Thoralf A1 - Schulz-Menger, Jeanette T1 - Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study N2 - Objectives Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. Methods A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. Results All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. Conclusions This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T. Y1 - 2010 U6 - https://doi.org/10.1007/s00330-010-1888-2 SN - 0938-7994 VL - 20 SP - 2844 EP - 2852 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Hagebeuker, Bianca A1 - Lange, Robert A1 - Ringbeck, Thorsten T1 - Bildverarbeitung mit der dritten Dimension : wenn die Pixel auch Laufzeiten auswerten JF - Sensor-Report : Sensorik, Messtechnik, Bildverarbeitung, Fabrikautomation. - 2004, H. 2 Y1 - 2004 SN - 0179-9592 SP - 11 EP - 17 PB - Rek & Thomas CY - St. Gallen ER - TY - JOUR A1 - Wolf, Martin R. T1 - Von Security Awareness zum Secure Behaviour JF - Hakin9 Extra – IT-Forensik N2 - Security Awareness ist derzeit ein viel diskutiertes Thema. Es reicht nicht, einfach nur ein paar technische Systeme (z.B. Firewalls) zu installieren, um ein angemessenes Schutzniveau zu erzielen. Neben einer guten Organisation von IT Security ist es auch notwendig, den Mitarbeiter einzubinden. Der vielzitierte "Faktor Mensch" ist derjenige, der die Technik korrekt anwenden muss und der durch falsches Verhalten technische und organisatorische Schutzmaßnahmen aushebeln kann. Deshalb reicht es nicht aus, wenn sich der Mitarbeiter der Gefahren bewusst ("aware") ist, er muss auch dementsprechend "sicher" handeln. Y1 - 2012 SN - 1733-7186 VL - 2012 IS - 5 SP - 18 EP - 19 PB - Software Wydawnictwo CY - Warszawa ER - TY - JOUR A1 - Fuchs, Britta A1 - Ritz, Thomas T1 - Absatzkanäle kaum verknüpft JF - IT-Mittelstand : IT-Business im Mittelstand Y1 - 2011 VL - 2011 IS - 9 SP - 16 PB - Medienhaus-Verlag CY - Bergisch-Gladbach ER -