TY - JOUR A1 - Zhubanova, Azhar A. A1 - Aknazarov, S. K. A1 - Mansurov, Zulkhair A1 - Digel, Ilya A1 - Kozhalakova, A. A. A1 - Akimbekov, Nuraly Shardarbekovich A1 - O'Heras, Carlos A1 - Tazhibayeva, S. A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Adsorption of bacterial Lipopolysaccharides and blood plasma proteins on modified carbonized materials N2 - Bacterial lipopolysaccharides (endotoxins) show strong biological effects at very low concentrations in human beings and many animals when entering the blood stream. These include affecting structure and function of organs and cells, changing metabolic functions, raising body temperature, triggering the coagulation cascade, modifying hemodynamics and causing septic shock. Because of this toxicity, the removal of even minute amounts is essential for safe parenteral administration of drugs and also for septic shock patients' care. The absence of a general method for endotoxin removal from liquid interfaces urgently requires finding new methods and materials to overcome this gap. Nanostructured carbonized plant parts is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study was comparative measurement of endotoxin- and blood proteins-related adsorption rate and adsorption capacity for different carboneous materials produced at different temperatures and under different surface modifications. As a main surface modificator, positively cbarged polymer, polyethileneimine (PEl) was used. Activated carbon materials showed good adsorption properties for LPS and some proteins used in the experiments. During the batch experiments, several techniques (dust removal, autoclaving) were used and optimized for improving the material's adsorption behavior. Also, with the results obtained it was possible to differentiate the materials according to their adsorption capacity and kinetic characteristics. Modification of the surface apparently has not affected hemoglobin binding to the adsorbent's surface. Obtained adsorption isotherms can be used as a powerful tool for designing of future column-based setups for blood purification from LPS, which is especially important for septic shock treatment. KW - Kohlenstofffaser KW - Lipopolysaccharide KW - nanostrukturierte carbonisierte Pflanzenteile KW - lipopolysaccharides KW - nanostructured carbonized plant parts Y1 - 2010 ER - TY - JOUR A1 - Wiescher, A. A1 - Kotliar, Konstantin A1 - Neuhann, T. A1 - Lanzl, Ines M. T1 - Rasch progrediente Visusminderung beider Augen bei einem jungen Patienten JF - Der Ophthalmologe N2 - Ein 34-jähriger männlicher Patient stellte sich zur Abklärung einer seit dem 9. Lebensjahr bestehenden und im letzten Jahr rasch progredienten Visusminderung beider Augen bei uns vor. Er beschrieb eine subjektiv zunehmende, im Spiegel für ihn selbst sichtbare, weißliche Trübung in der Pupille beidseits und eine starke Blendempfindlichkeit. Nebenbefundlich gab er rezidivierende Konjunktivitiden und morgens verklebte Lider an. Eine Allergie auf Gräserpollen und eine Unverträglichkeit auf Alkohol sowie mehrere Lebensmittel seien ebenfalls bekannt. Zusätzlich leidet der Patient an stark ausgeprägtem atopischem Ekzem. Dieses wurde nie systemisch, sondern nur bei Bedarf mit kortisonhaltiger Salbe therapiert. Y1 - 2010 U6 - http://dx.doi.org/10.1007/s00347-007-1586-x SN - 1433-0423 VL - 105 IS - 4 SP - 389 EP - 392 PB - Springer CY - Berlin ER - TY - JOUR A1 - Werner, Frederik A1 - Spelthahn, H. A1 - Schöning, Michael Josef A1 - Krumbe, C. A1 - Wagner, Torsten A1 - Yoshinobu, T. A1 - Keusgen, M. T1 - Neue Ansteuerungselektronik für LAPS-basierte Biosensoren zur gleichzeitig ortsaufgelösten Messung der pH-Konzentration JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 109 EP - 114 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Wagner, Torsten A1 - Werner, Frederik A1 - Miyamoto, Ko-ichiro A1 - Ackermann, Hans-Josef A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - FPGA-based LAPS device for the flexible design of sensing sites on functional interfaces JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 844 EP - 849 ER - TY - JOUR A1 - Wagner, Torsten A1 - Miyamoto, Ko-ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Novel combination of digital light processing (DLP) and light-addressable potentiometric sensors (LAPS) for flexible chemical imaging JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 520 EP - 523 ER - TY - JOUR A1 - Ullrich, Sebastian A1 - Grottke, Oliver A1 - Rossaint, Rolf A1 - Staat, Manfred A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Virtual Needle Simulation with Haptics for Regional Anaesthesia Y1 - 2010 N1 - IEEE Virtual Reality 2010, Workshop on Medical Virtual Environments, Waltham, MA, USA, March 21, 2010 SP - 1 EP - 3 ER - TY - JOUR A1 - Turek, Monik A1 - Heiden, Wolfgang A1 - Guo, Sharon A1 - Riesen, Alfred A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 817 EP - 823 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - RPRT A1 - Temiz Artmann, Aysegül T1 - Frühgeburtenrate mindern durch ein Prognoseverfahren für den vorzeitigen Blasensprung - PROMPT (Premature rupture of membranes prediction test) : Abschlussbericht ; Laufzeit des Vorhabens: 01.03.2007 - 31.12.2009 Y1 - 2010 U6 - http://dx.doi.org/10.2314/GBV:644277858 N1 - Förderkennzeichen BMBF 1772X07 PB - Technische Informationsbibliothek u. Universitätsbibliothek CY - Aachen ER - TY - JOUR A1 - Staat, Manfred A1 - Sponagel, Stefan A1 - Nguyen, Nhu Huynh T1 - Experiment and material model for soft tissue materials JF - Constitutive models for rubber VI : proceedings of the sixth European Conference on Constitutive Models for Rubber, Dresden, Germany, 7 - 10 September 2009 / eds. Gert Heinrich ... Y1 - 2010 SN - 978-0-415-56327-7 SP - 465 EP - 470 PB - CRC Press CY - Boca Raton [u.a.] ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schaffrath, Sophie A1 - Coppe, Thomas A1 - Rufi, Frederic A1 - Schöning, Michael Josef T1 - Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions JF - Physica status solidi (a) : applications and material science. 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 930 EP - 934 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices JF - Physica status solidi (a). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 781 EP - 786 ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Maki, Rafael M. A1 - Paulovich, Fernando V. A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Oliveira, Maria C. F. de A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Use of Information Visualization Methods Eliminating Cross Talk in Multiple Sensing Units Investigated for a Light-Addressable Potentiometric Sensor JF - Analytical Chemistry (2010) Y1 - 2010 SN - 0003-2700 SP - 61 EP - 65 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kirchner, Patrick A1 - Ng, Yue Ann A1 - Spelthahn, Heiko A1 - Schneider, Andreas A1 - Henkel, Hartmut A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg A1 - Keusgen, Michael T1 - Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 787 EP - 792 ER - TY - BOOK A1 - Schelthoff, Christof T1 - Mathematik im ingenieurwissenschaftlichen Bachelorstudium / 4., überarb. Aufl. Y1 - 2010 SN - 978-3-8322-9288-1 PB - Shaker CY - Aachen ER - TY - BOOK A1 - Schelthoff, Christof T1 - Mathematik im ingenieurwissenschaftlichen Bachelorstudium : Lösung der Übungs- und Klausuraufgaben Y1 - 2010 SN - 978-3-8322-9502-8 PB - Shaker CY - Aachen ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 913 EP - 918 ER - TY - JOUR A1 - Probst, M. A1 - Behbahani, Mehdi A1 - Borrmann, E. A1 - Elgeti, S. A1 - Nicolai, M. A1 - Behr, M. T1 - Hemodynamic Modeling for Numerical Analysis and Design of Medical Devices Y1 - 2010 N1 - Posterpresentation ; NIC Symposium 2010 ; 24 - 25 February 2010 Jülich, Germany ER - TY - JOUR A1 - Pressler, Axel A1 - Esefeld, Katrin A1 - Scherr, Johannes A1 - Ali, Mohammad A1 - Hanssen, Henner A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Halle, Martin A1 - Kaemmerer, Harald A1 - Schmidt-Trucksäss, Arno A1 - Hager, Alfred T1 - Structural alterations of retinal arterioles in adults late after repair of aortic isthmic coarctation JF - The American Journal of Cardiology N2 - Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5%, first to third quartile 2.1% to 4.5% vs 3.6%, first to third quartile 2.2% to 4.3%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.amjcard.2009.10.070 SN - 0002-9149 VL - 105 IS - 5 SP - 740 EP - 744 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, H. A1 - Schöning, Michael Josef T1 - Automatisiertes „wafer level“-Testsystem zur Charakterisierung von siliziumbasierten Chemo- und Biosensoren JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 89 EP - 92 PB - VDE Verlag CY - Berlin ER -