TY - JOUR A1 - Zhubanova, А. A1 - Mansurov, Z.A. A1 - Digel, Ilya A1 - Saviskaya, I.S. A1 - Akimbekov, Nuraly S. T1 - Designing of Heterogeneous Nanobiocomposites for Biotechnology JF - KazNU Bulletin. Biology series Y1 - 2013 SN - 1563-0218 VL - 59 IS - No 3/1 SP - 89 EP - 93 ER - TY - JOUR A1 - Buniatyan, V. A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Aroutiounian, V. M. A1 - Schöning, Michael Josef T1 - BaxSr1-x TiO3/pc-Si heterojunction JF - Armenian journal of physics Y1 - 2013 SN - 1829-1171 VL - 6 IS - 4 SP - 177 EP - 187 PB - National Academy of Sciences of Armenia CY - Yerevan ER - TY - JOUR A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers JF - Physica Status Solidi (A) N2 - Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution. Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200941 SN - 1521-396X ; 0031-8965 VL - 210 IS - 5 SP - 905 EP - 910 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Akimbekov, Nuraly S. A1 - Digel, Ilya A1 - Savitkaya, I.S. A1 - Zhubanova, A.A. A1 - Tastambek, K.T. T1 - Investigations of LPS endotoxin elimination in the flowing column conditions with the sorbent on the basis of carbonized rice husk JF - KazNU Bulletin. Biology series Y1 - 2013 SN - 1563-0218 N1 - Original in russischer Sprache VL - 57 IS - 1 SP - 124 EP - 127 ER - TY - JOUR A1 - Fabo, Sabine ED - Mohr, Klaus T1 - Pepräsentatives Dösen JF - Idiopendent Lyfestile (Boxhorn ; 27) Y1 - 2013 SN - 1864-2535 SP - 134 EP - 139 PB - FH CY - Aachen ER - TY - JOUR A1 - Wolf, Martin R. A1 - Altgen, Jannik T1 - IT Service Management in der Region Aachen : White Paper Y1 - 2013 SP - 1 EP - 13 ER - TY - JOUR A1 - Weemstra, Monique A1 - Eilmann, Britta A1 - Sass-Klaassen, Ute G. W. A1 - Sterck, Frank J. T1 - Summer droughts limit tree growth across 10 temperate species on a productive forest site JF - Forest Ecology and Management Y1 - 2013 U6 - https://doi.org/doi:10.1016/j.foreco.2013.06.007 SN - 0378-1127 (Print) SN - 1872-7042 (Online) VL - 2013 IS - 306 SP - 142 EP - 149 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abulnaga, El-Hussiny A1 - Pinkenburg, Olaf A1 - Schiffels, Johannes A1 - E-Refai, Ahmed A1 - Buckel, Wolfgang A1 - Selmer, Thorsten T1 - Effect of an Oxygen-Tolerant Bifurcating Butyryl Coenzyme A Dehydrogenase/Electron-Transferring Flavoprotein Complex from Clostridium difficile on Butyrate Production in Escherichia coli JF - Journal of bacteriology Y1 - 2013 SN - 1098-5530 [E-Journal] SN - 0021-9193 [Print] VL - 195 IS - 16 SP - 3704 EP - 3713 ER - TY - JOUR A1 - Laack, Walter van T1 - Our world is well ordered in measurement and number : or why natural constants are as they are JF - American Journal of Humanities and Social Sciences (AHSS) N2 - All the important natural constants can be logically explained with and derived from the first four ordinal numbers, 1, 2, 3 and 4, its addition to ten and finally the standard values for obviously maximal feasibility Ω and the optimum in our world, the Golden Section (GS), i.e. the number sequences 273 and 618. They both are the first three numbers of irrational results by an arithmetical transformation of simple geometrical relationships by creating multiplicity out of singularity. Both of them show that the infinite is inherent in finiteness and explain in a simple way the smallest deviations and fluctuations between the physical AS-IS state and the obvious spiritual ideal behind: Wherever we look in this world, and especially in important key-positions, we regularly find these sequences. All of the above mentioned numbers so seem to be key players in our world, what can be demonstrated by the derivation of natural constants. Y1 - 2013 U6 - https://doi.org/10.11634/232907811301390 SN - 2329-079X SN - 2329-0781 VL - 1 IS - 4 SP - 219 EP - 221 ER - TY - JOUR A1 - Lévesque, Mathieu A1 - Saurer, Matthias A1 - Siegwolf, Rolf A1 - Eilmann, Britta A1 - Brang, Peter A1 - Bugmann, Harald A1 - Rigling, Andreas T1 - Drought response of five conifer species under contrasting water availability suggests high vulnerability of Norway spruce and European larch JF - Global Change Biology Y1 - 2013 U6 - https://doi.org/10.1111/gcb.12268 SN - 1365-2486 (Online) SN - 1354-1013 (Print) VL - 19 IS - 10 SP - 3184 EP - 3199 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Özerdem, Celal A1 - Rieger, Jan A1 - Kellmann, Peter A1 - Santoro, Davide A1 - Lindel, Tomasz D. A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Niendorf, Thoralf T1 - Modular 32-channel transceiver coil array for cardiac MRI at 7.0T JF - Magnetic Resonance in Medicine N2 - Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T. Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24903 SN - 1522-2594 VL - 72 IS - 1 SP - 276 EP - 290 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Eilmann, Britta A1 - de Vries, Sven M. G. A1 - den Ouden, Jan A1 - Mohren, Godefridus M. J. A1 - Sauren, Pascal A1 - Sass-Klaassen, Ute G. W. T1 - Origin matters! Difference in drought tolerance and productivity of coastal Douglas-fir (Pseudotsuga menziesii (Mirb.)) provenances JF - Forest Ecology and Management Y1 - 2013 U6 - https://doi.org/doi:10.1016/j.foreco.2013.03.031 SN - 1872-7042 (Online) SN - 0378-1127 (Print) VL - 2013 IS - 302 SP - 133 EP - 143 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wegner, Lena A1 - von Arx, Georg A1 - Sass-Klaassen, Ute G. W. A1 - Eilmann, Britta T1 - ROXAS – an efficient and accurate tool to detect vessels in diffuse-porous species JF - IAWA Journal / International Association of Wood Anatomists Y1 - 2013 U6 - https://doi.org/10.1163/22941932-00000034 SN - 0928-1541 (Print) SN - 2294-1932 (Online) VL - 34 IS - 4 SP - 425 EP - 432 PB - Brill CY - Leiden ER - TY - JOUR A1 - Gaiser, Lorenz ED - Mohr, Klaus T1 - Rapidshare Kinocharts JF - Idiopendent Lyfestile (Boxhorn ; 27) Y1 - 2013 SN - 1864-2535 SP - 150 EP - 153 PB - FH CY - Aachen ER - TY - JOUR A1 - Mohr, Klaus T1 - DEBEDE DE HAKAPE JF - Idiopendent Lyfestile (Boxhorn ; 27) Y1 - 2013 SN - 1864-2535 SP - 40 EP - 45 PB - Fachhochschule Aachen CY - Aachen ER - TY - JOUR A1 - Poghossian, Arshak A1 - Weil, M. A1 - Cherstvy, A. G. A1 - Schöning, Michael Josef T1 - Electrical monitoring of polyelectrolyte multilayer formation by means of capacitive field-effect devices JF - Analytical and bioanalytical chemistry N2 - The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte–insulator–semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance–voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed. Y1 - 2013 U6 - https://doi.org/10.1007/s00216-013-6951-9 SN - 1432-1130 ; 1618-2642 VL - 405 IS - 20 SP - 6425 EP - 6436 PB - Springer CY - Berlin ER - TY - JOUR A1 - Laack, Walter van A1 - Levers, A. A1 - Staat, Manfred T1 - Gonarthrosetherapie auf Kernspinresonanzbasis mit MBST-Vierjahresbeobachtungen JF - Orthopädische Nachrichten : Zeitung für Orthopädie und Unfallchirurgie. 2013, H. 7/8 Y1 - 2013 SN - 1437-2193 SP - 13 PB - Biermann CY - Köln ER - TY - JOUR A1 - Kramer, Friederike A1 - Halamkova, Lenka A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny A1 - Halamek, Jan T1 - Biocatalytic analysis of biomarkers for forensic identification of ethnicity between Caucasian and African American JF - The analyst. August 2013 Y1 - 2013 SN - 1364-5528 (E-Journal); 0003-2654 (Print) VL - Vol. 138 SP - 6251 EP - 6257 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Bäcker, Matthias A1 - Rakowski, D. A1 - Poghossian, Arshak A1 - Biselli, Manfred A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis JF - Journal of Biotechnology N2 - A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses. Y1 - 2013 U6 - https://doi.org/10.1016/j.jbiotec.2012.03.014 SN - 0168-1656 VL - 163 IS - 4 SP - 371 EP - 376 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bäcker, Matthias A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Degradationsverhalten bioabbaubarer Polymere : siliziumbasierte Sensorik zur Überwachung JF - GIT Labor-Fachzeitschrift Y1 - 2013 SN - 0016-3538 SP - 32 EP - 33 PB - Wiley-VCH CY - Weinheim ER -