TY - JOUR A1 - Pieper, Martin T1 - Multiobjective optimization with expensive objectives applied to a thermodynamic material design problem JF - Proceedings in applied mathematics and mechanics : PAMM. 11 (2011), H. 1 Y1 - 2011 SN - 1617-7061 SP - 733 EP - 734 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER - TY - JOUR A1 - Paczkowski, Sebastian A1 - Weißbecker, Bernhard A1 - Schöning, Michael Josef A1 - Schütz, Stefan T1 - Biosensors on the Basis of Insect Olfaction JF - Insect biotechnology / Andreas Vilcinskas, ed. Y1 - 2011 SN - 978-90-481-9640-1 N1 - Biologically-inspired system ; 2 SP - 225 EP - 240 PB - Springer CY - Dordrecht [u.a.] ER - TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Schäfer, Lena C. A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Maderwald, Stefan T1 - Open design eight-channel transmit/receive coil for high-resolution and real-time ankle imaging at 7 T JF - Medical Physics N2 - Purpose: At 1.5 T, real-time MRI of joint movement has been shown to be feasible. However, 7 T, provides higher SNR and thus an improved potential for parallel imaging acceleration. The purpose of this work was to build an open, U-shaped eight-channel transmit/receive microstrip coil for 7 T MRI to enable high-resolution and real-time imaging of the moving ankle joint. Methods: A U-shaped eight-channel transmit/receive array for the human ankle was built.urn:x-wiley:00942405:mp3399:equation:mp3399-math-0001-parameters and urn:x-wiley:00942405:mp3399:equation:mp3399-math-0002-factor were measured. SAR calculations of different ankle postures were performed to ensure patient safety. Inhomogeneities in the transmit field consequent to the open design were compensated for by the use of static RF shimming. High-resolution and real-time imaging was performed in human volunteers. Results: The presented array showed good performance with regard to patient comfort and image quality. High acceleration factors of up to 4 are feasible without visible acceleration artifacts. Reasonable image homogeneity was achieved with RF shimming. Conclusions: Open, noncylindrical designs for transmit/receive coils are practical at 7 T and real-time imaging of the moving joint is feasible with the presented coil design. Y1 - 2011 U6 - https://doi.org/10.1118/1.3553399 SN - 2473-4209 VL - 38 IS - 3 SP - 1162 EP - 1167 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Oosterhuis, Koen A1 - Öhlschläger, Peter A1 - Berg, Joost H. van den A1 - Toebes, Mireille A1 - Gomez, Raquel A1 - Schumacher, Ton N. A1 - Haanen, John B. T1 - Preclinical development of highly effective and safe DNA vaccines directed against HPV 16 E6 and E7 JF - International Journal of Cancer Y1 - 2011 SN - 1097-0215 VL - 129 IS - 2 SP - 397 EP - 406 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Norda, Hannah A1 - Butenweg, Christoph T1 - Möglichkeiten und Grenzen der Anwendbarkeit statisch nichtlinearer Verfahren nach DIN EN 1998-1 JF - Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik. Beilage: D-A-CH-Mitteilungsblatt Y1 - 2011 SN - 1436-4867 (E-Journal); 0005-6650 (Print) N1 - Printausgabe in der Bibliothek Bayernallee vorhanden: 13 Z 049-2011 VL - Band 86 SP - S13 EP - S21 PB - VDI Fachmedien CY - Düsseldorf ER - TY - JOUR A1 - Niemüller, Tim A1 - Ferrein, Alexander A1 - Eckel, Gerhard A1 - Pirro, David A1 - Podbregar, Patrick A1 - Kellner, Tobias A1 - Rath, Christoph A1 - Steinbauer, Gerald T1 - Providing Ground-truth Data for the Nao Robot Platform JF - RoboCup 2010: Robot Soccer World Cup XIV Y1 - 2011 SN - 978-3-642-20217-9 N1 - Lecture Notes in Computer Science ; 6556 SP - 133 EP - 144 PB - Springer CY - Berlin ER - TY - JOUR A1 - Niehaus, F. A1 - Gabor, E. A1 - Wieland, S. A1 - Siegert, Petra A1 - Maurer, Karl-Heinz A1 - Eck, J. T1 - Enzymes for the laundry industries: tapping the vast metagenomic pool of alkaline proteases JF - Microbial biotechnology Y1 - 2011 SN - 1432-0614 (E-Journal); 0171-1741 (Print); 0175-7598 (Print); 0340-2118 (Print) VL - Vol. 4 IS - Iss. 6 SP - 767 EP - 776 PB - Springer CY - Berlin ER - TY - JOUR A1 - Nguyen-Xuan, H. A1 - Rabczuk, T. A1 - Nguyen-Thoi, T. A1 - Tran, Thanh Ngoc A1 - Nguyen-Thanh, N. T1 - Computation of limit and shakedown loads using a node-based smoothed finite element method JF - International Journal for Numerical Methods in Engineering N2 - This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods. Y1 - 2011 U6 - https://doi.org/10.1002/nme.3317 SN - 1097-0207 VL - 90 IS - 3 SP - 287 EP - 310 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Mukherjee, Krishnendu A1 - Ramazani, Ali A1 - Yang, Li A1 - Prahl, Ulrich A1 - Bleck, Wolfgang A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Abdurakhmanov, Aydemir T1 - Characterization of gas metal arc welded hot rolled DP600 steel JF - Steel research international Y1 - 2011 SN - 1869-344X (E-Book); 1611-3683 (Print) VL - Vol. 82 IS - Iss. 12 SP - 1408 EP - 1416 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Mottaghy, Darius A1 - Pechnig, Renate A1 - Vogt, Christian T1 - The geothermal project Den Haag: 3D numerical models for temperature prediction and reservoir simulation JF - Geothermics N2 - The proposed Den Haag Zuidwest district heating system of the city of The Hague consists of a deep doublet in a Jurassic sandstone layer that is designed for a production temperature of 75 °C and a reinjection temperature of 40 °C at a flow rate of 150 m3 h−1. The prediction of reservoir temperature and production behavior is crucial for success of the proposed geothermal doublet. This work presents the results of a study of the important geothermal and geohydrological issues for the doublet design. In the first phase of the study, the influences of the three-dimensional (3D) structures of anticlines and synclines on the temperature field were examined. A comprehensive petrophysical investigation was performed to build a large scale 3D-model of the reservoir. Several bottomhole temperatures (BHTs), as well as petrophysical logs were used to calibrate the model using thermal conductivity measurements on 50 samples from boreholes in different lithological units in the study area. Profiles and cross sections extracted from the calculated temperature field were used to study the temperature in the surrounding areas of the planned doublet. In the second phase of the project, a detailed 3D numerical reservoir model was set up, with the aim of predicting the evolution of the producer and injector temperatures, and the extent of the cooled area around the injector. The temperature model from the first phase provided the boundary conditions for the reservoir model. Hydraulic parameters for the target horizons, such as porosity and permeability, were taken from data available from the nearby exploration wells. The simulation results are encouraging as no significant thermal breakthrough is predicted. For the originally planned location of the producer, the extracted water temperature is predicted to be around 79 °C, with an almost negligible cooling in the first 50 years of production. When the producer is located shallower parts of the reservoir, the yield water temperatures is lower, starting at ≈76 °C and decreasing to ≈74 °C after 50 years of operation. This comparatively larger decrease in temperature with time is caused by the structural feature of the reservoir, namely a higher dip causes the cooler water to easily move downward. In view of the poor reservoir data, the reservoir simulation model is constructed to allow iterative updates using data assimilation during planned drilling, testing, and production phases. Measurements during an 8 h pumping test carried out in late 2010 suggest that a flow rate of 150 m3 h−1 is achievable. Fluid temperatures of 76.5 °C were measured, which is very close to the predicted value. Y1 - 2011 U6 - https://doi.org/10.1016/j.geothermics.2011.07.001 SN - 0375-6505 VL - 40 IS - 3 SP - 199 EP - 210 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Yoshida, Midori A1 - Sakai, Taito A1 - Matsuzaka, Atsushi A1 - Wagner, Torsten A1 - Kanoh, Sanoh A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - Differential setup of light-addressable potentiometric sensor with an enzyme reactor in a flow channel JF - Japanese Journal of Applied Physics. 50 (2011) Y1 - 2011 SN - 0021-4922 SP - 04DL08-1 EP - 04DL08-5 PB - Japan Society of Applied Physics CY - Bristol ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Kanoh, Shin`ichiro A1 - Schöning, Michael Josef T1 - Phase-mode LAPS and its application to chemical imaging JF - Sensors and Actuators B: Chemical. 154 (2011), H. 1 Y1 - 2011 SN - 1873-3077 SP - 28 EP - 32 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Kanoh, Shin`ichiro A1 - Schöning, Michael Josef T1 - Phase-mode operation of FDM-LAPS JF - Sensor letters Y1 - 2011 SN - 1546-1971 VL - 9 IS - 2 SP - 691 EP - 694 PB - American Scientific Publishers CY - Stevenson Ranch, Calif. ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Mimura, Shuhei A1 - Kanoh, Shiníchiro A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - Constant-phase-mode operation of the light-addressable potentiometric sensor JF - Sensors and Actuators B: Chemical. 154 (2011), H. 2 Y1 - 2011 SN - 1873-3077 N1 - EUROSENSORS XXIII SP - 119 EP - 123 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, K. A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, T. T1 - Multi-well structure for cell culture on the chemical imaging sensor Y1 - 2011 N1 - 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS) , Date: 5-9 June 2011 SP - 2130 EP - 2132 PB - IEEE CY - New York ER - TY - JOUR A1 - Mischke, Winfried A1 - Girkens, Hans-Peter T1 - Kostenvorschuss beim selbständigen Beweisverfahren : zur Kostentragung, wenn der Antragsteller den für die Durchführung erforderlichen Vorschuss für den Sachverständigen nicht zahlt JF - Zeitschrift für die Anwaltspraxis : ZAP Y1 - 2011 SN - 0936-7292 IS - Fach 13 SP - 1739 EP - 1740 PB - Westlaw Datenbank GmbH CY - Frankfurt a. M. ER - TY - JOUR A1 - Milnickel, Birte A1 - Grap, Rolf Dietmar ED - Suntrop, Carsten T1 - Chemielogistik im Kontext allgemeiner logistischer Anforderungen JF - Chemielogistik : Markt, Geschäftsmodelle, Prozesse Y1 - 2011 SN - 978-3-527-32531-3 SP - 3 EP - 22 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Mikielewicz, Marek A1 - Kotliar, Konstantin A1 - Barraquer, Rafael I. A1 - Michael, Ralph T1 - Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus JF - British Journal of Ophthalmology (eBJO) Y1 - 2011 SN - 1468-2079 VL - 95 IS - 6 SP - 793 EP - 798 PB - BMJ Publ. Group CY - London ER - TY - JOUR A1 - Maus, Stefan A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Forensic Analysis of Geodata in Android Smartphones Y1 - 2011 N1 - Cyberforensics 2011, Glasgow SP - 1 EP - 11 ER - TY - JOUR A1 - Martins, Berta M. A1 - Blaser, Martin A1 - Feliks, Mikolaj A1 - Ullmann, Matthias G. A1 - Buckel, Wolfgang A1 - Selmer, Thorsten T1 - Structural basis for a Kolbe-type decarboxylation catalyzed by a glycyl radical enzyme JF - Journal of the American Chemical Society Y1 - 2011 N1 - Just accepted manuscript SP - 1 EP - 33 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Manea, Marilena A1 - Leurs, Ulrike A1 - Orban, Erika A1 - Baranyai, Zsuzsa A1 - Öhlschläger, Peter A1 - Marquardt, Andreas A1 - Schulcz, Akos A1 - Tejeda, Miguel T1 - Enhanced Enzymatic Stability and Antitumor Activity of Daunorubicin-GnRH-III Bioconjugates Modified in Position 4 JF - Bioconjugate Chemistry Y1 - 2011 SN - 1520-4812 VL - 22 IS - 7 SP - 1320 EP - 1329 PB - ACS CY - Washington, DC ER - TY - JOUR A1 - Malzahn, Kerstin A1 - Windmiller, Joshua Ray A1 - Valdés-Ramírez, Gabriela A1 - Wang, Joseph A1 - Schöning, Michael Josef T1 - Wearable electrochemical sensors for in situ analysis in marine environments JF - Analyst. 136 (2011), H. 14 Y1 - 2011 SN - 0003-2654 SP - 2912 EP - 2917 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Maier, M. M. A1 - Feucht, N. A1 - Winkler von Mohrenfels, C. A1 - Kotliar, Konstantin A1 - Fabian, E. A1 - Lohmann, C. P. T1 - Nahtlose Cerclage mit Skleratunnelfixation. Sutureless Encircling Band - Clinical Experience JF - Klinische Monatsblätter für Augenheilkunde Y1 - 2011 SN - 0344-6360 VL - 228 IS - 5 SP - 473 EP - 476 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Lustfeld, H. A1 - Hirschfeld, J. A. A1 - Reißel, Martin A1 - Steffen, B. T1 - Enhancement of precision and reduction of measuring points in tomographic reconstructions JF - Physics Letters A Y1 - 2011 SN - 0375-9601 VL - 375 IS - 8 SP - 1167 EP - 1171 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Lind, Thorsten Patric T1 - Handelndenhaftung bei Vorrats- oder Mantel-GmbH nur für vor Offenlegung der wirtschaftlichen Neugründung ohne Zustimmung aller Gesellschafter vorgenommene Geschäfte : BGH, Urteil vom 12.07.2011 - II ZR 71/11 : Anmerkung JF - Fachdienst Zivilrecht - LMK - Kommentierte BGH-Rechtsprechung, Lindenmaier-Möhring Y1 - 2011 SN - 1611-1095 IS - 11 PB - Beck CY - München ER - TY - JOUR A1 - Lind, Thorsten Patric T1 - Keine Beseitigung der Zahlungsunfähigkeit und ihrer Kenntnis durch Patronatserklärung : BGH, Urteil vom 19.05.2011 - IX ZR 9/10 : Anmerkung JF - Fachdienst Zivilrecht - LMK - Kommentierte BGH-Rechtsprechung, Lindenmaier-Möhring Y1 - 2011 SN - 1611-1095 IS - Ausg. 8 SP - 320922 PB - Beck CY - München ER - TY - JOUR A1 - Lanzl, Ines M. A1 - Seidova, Seid-Fatima A1 - Maier, Mathias A1 - Schmidt-Trucksäss, Arno A1 - Halle, Martin A1 - Kotliar, Konstantin T1 - Dynamic retinal vessel response to flicker in age-related macular degeneration patients before and after vascular endothelial growth factor inhibitor injection JF - Acta Ophthalmologica Y1 - 2011 SN - 1755-3768 VL - 89 IS - 5 SP - 472 EP - 479 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Landers, Ernst Ulrich A1 - Kern, Alexander T1 - Future evolution of risk management for structures : Advancement for the future IEC 62305-2 Ed3 Y1 - 2011 N1 - XI International Symposium on Lightning Protection (SIPDA), Fortaleza (Brasilien), 2011. SP - 1 EP - 6 PB - IEEE CY - New York ER - TY - JOUR A1 - Kurulgan Demirci, Eylem A1 - Demirci, T. A1 - Trzewik, Jürgen A1 - Linder, Peter A1 - Karakulah, G. A1 - Artmann, Gerhard A1 - Sakizli, M. A1 - Temiz Artmann, Aysegül T1 - Genome-Wide Gene Expression Analysis of NIH 3T3 Cell Line Under Mechanical Stimulation JF - Cellular and molecular bioengineering. 4 (2011), H. 1 Y1 - 2011 SN - 1865-5025 SP - 46 EP - 55 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kuperjans, Isabel T1 - Gute Planung ist alles : Energieeffizienz in der Pharmaproduktion JF - Pharma + Food Y1 - 2011 SN - 1434-8942 VL - 2011 IS - 2 SP - 8 EP - 10 PB - Hüthig CY - Heidelberg ER - TY - JOUR A1 - Krott, Daniel A1 - Gerhards, Michael A1 - Skorupa, Sascha A1 - Sander, Volker T1 - NHiLA - Bridging the Gap Between .NET and UNICORE JF - UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.) Y1 - 2011 SN - 9783893367504 N1 - UNICORE Summit ; (2011 ; 2011.07.07-08 ; Torun) ; Schriften des Forschungszentrums Jülich IAS Series 9 SP - 77 EP - 86 PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Kroll-Ludwigs, Kathrin T1 - Anmerkung zu EuGH, Urt. v. 1.3.2011, Rs. C-236/09 Association belge des Consomma-teurs Test-Achats JF - JuristenZeitung (JZ) Y1 - 2011 U6 - https://doi.org/10.1628/002268811796448996 SN - 1868-7067 VL - 66 IS - 14 SP - 734 EP - 737 PB - Mohr Siebeck CY - Tübingen ER - TY - JOUR A1 - Kroll-Ludwigs, Kathrin T1 - Anmerkung zu EuGH, Urt. v. 22. 12. 2010, Rs. C-208/09 - Sayn-Wittgenstein JF - GPR : Zeitschrift für das Privatrecht der Europäischen Union Y1 - 2011 U6 - https://doi.org/10.1515/gpr.2011.8.5.242 SN - 2193-9519 IS - 5 SP - 242 EP - 245 PB - Verlag Dr. Otto Schmidt CY - Köln ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Breyer, Tobias A1 - Kruszona, Stefan A1 - Maderwald, Stefan A1 - Brote, Irina A1 - Gizewski, Elke R. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - A transmit/receive radiofrequency array for imaging the carotid arteries at 7 Tesla: coil design and first in vivo results JF - Investigative Radiology N2 - Objective: To develop a transmit/receive radiofrequency (RF) array for magnetic resonance imaging (MRI) of the carotid arteries at 7 T. The prototype is characterized in numerical simulations and bench measurements, and the feasibility of plaque imaging at 7 T is demonstrated in first in vivo images. Materials and Methods: The RF phased array coil consists of 8 surface loop coils. To allow imaging of both sides of the neck, the RF array is divided into 2 coil clusters, each with 4 overlapping loop elements. For safety validation, numerical computations of the RF field distribution and the corresponding specific absorption rate were performed on the basis of a heterogeneous human body model. To validate the coil model, maps of the transmit B1+ field were compared between simulation and measurement. In vivo images of a healthy volunteer and a patient (ulcerating plaque and a 50% stenosis of the right internal carotid artery) were acquired using a 3-dimensional FLASH sequence with a high isotropic spatial resolution of 0.54 mm as well as using pulse-triggered proton density (PD)/T2-weighted turbo spin echo sequences. Results: Measurements of the S-parameters yielded a reflection and isolation of the coil elements of better than −18 and −13 dB, respectively. Measurements of the g-factor indicated good image quality for parallel imaging acceleration factors up to 2.4. A similar distribution and a very good match of the absolute values were found between the measured and simulated B1+ transmit RF field for the validation of the coil model. In vivo images revealed good signal excitation of both sides of the neck and a high vessel-to-background image contrast for the noncontrast-enhanced 3-dimensional FLASH sequence. Imaging at 7 T could depict the extent of stenosis, and revealed the disruption and ulcer of the plaque. Conclusions: This study demonstrates that 2 four-channel transmit/receive RF arrays for each side of the neck is a suitable concept for in vivo MRI of the carotid arteries at 7 Tesla. Further studies are needed to explore and exploit the full potential of 7 T high-field MRI for carotid atherosclerotic plaque imaging. Y1 - 2011 U6 - https://doi.org/10.1097/RLI.0b013e318206cee4 SN - 1536-0210 VL - 46 IS - 4 SP - 246 EP - 254 PB - Wolters Kluwer CY - Köln ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines M. A1 - Schmidt-Trucksäss, A. A1 - Sitnikova, Diana A1 - Ali, Mohammad A1 - Blume, Katharina A1 - Halle, Martin A1 - Hansser, Henner T1 - Dynamic retinal vessel response to flicker in obesity: A methodological approach JF - Microvascular Research Y1 - 2011 SN - 0026-2862 VL - 81 IS - 1 SP - 123 EP - 128 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines M. T1 - Can vascular function be assessed by the interpretation of retinal vascular diameter changes? JF - Investigative Ophthalmology & Visual Science, IOVS. 52 (2011), H. 1 Y1 - 2011 SN - 0146-0404 SP - 635 EP - 636 PB - ARVO CY - Rockville, Md. ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Baumann, Marcus A1 - Vilser, Walthard A1 - Lanzl, Ines M. T1 - Pulse wave velocity in retinal arteries of healthy volunteers JF - British Journal of Ophthalmology (eBJO) Y1 - 2011 SN - 1468-2079 VL - 95 IS - 11 SP - 675 EP - 679 PB - BMJ Publ. Group CY - London ER - TY - JOUR A1 - Kleefeld, Andreas A1 - Reißel, Martin T1 - The Levenberg–Marquardt method applied to a parameter estimation problem arising from electrical resistivity tomography JF - Applied Mathematics and Computation Y1 - 2011 SN - 0096-3003 VL - 217 IS - 9 SP - 4490 EP - 4501 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirschner-Hermanns, Ruth A1 - Klementz, T. A1 - Haselhuhn, Angelika A1 - Jakse, Gerhard A1 - Heidenreich, A. A1 - Brehmer, Bernhard T1 - Drangsymptomatik nach onkologisch erfolgreicher Prostatakarzinomtherapie : prospektive Studie zum Einfluss von Therapiemodalität, Morbidität und epidemiologischen Faktoren auf die Lebensqualität JF - Der Urologe Y1 - 2011 SN - 1433-0563 VL - Vol. 50 IS - Iss. 11 SP - 1412 EP - 1419 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Suso, Henri-Pierre A1 - Kupyna, Andriy A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Optimisation and fabrication of a calorimetric gas sensor built up on a polyimide substrate for H2O2 monitoring JF - Physica status solidi (a) : applications and material science. 208 (2011), H. 6 Y1 - 2011 SN - 1862-6319 SP - 1235 EP - 1240 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Kirchner, Patrick A1 - Li, Bin A1 - Spelthahn, Heiko A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Thin-film calorimetric H2O2 gas sensor for the validation of germicidal effectivity in aseptic filling processes JF - Sensors and Actuators B: Chemical. 154 (2011), H. 2 Y1 - 2011 SN - 1873-3077 N1 - EUROSENSORS XXIII SP - 257 EP - 263 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Probability of lightning strikes to air-terminations of structures using the electro-geometrical model theory and the statistics of lightning current parameters JF - Atmospheric Research. 104 (2011) Y1 - 2011 SN - 0169-8095 N1 - Article in Press PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Detaillierte Berechnung der Einfangwirksamkeiten von Fangeinrichtungen mit einem dynamischen elektro-geometrischen Modell - Detailed calculation of the interception efficiencies for airtermination systems using a dynamic electro-geometrical model Y1 - 2011 N1 - 9. VDE/ABB-Blitzschutztagung, Neu-Ulm 2011 SP - 1 EP - 5 ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Calculation of interception efficiencies for airterminations using a dynamic electro-geometrical model Y1 - 2011 N1 - XI International Symposium on Lightning Protection (SIPDA), Fortaleza (Brasilien), 2011. SP - 1 EP - 6 PB - IEEE CY - New York ER - TY - JOUR A1 - Kern, Alexander A1 - Scheibe, Klaus T1 - Die neuen internationalen Blitzschutz-Standards der Reihe IEC 62305:2010 : Überblick und Stand der Umsetzung in die nationale Normenreihe DIN EN 62305 JF - 9. VDE/ABB-Blitzschutztagung : Vorträge der 9. VDE/ABB-Fachtagung vom 27. bis 28. Oktober 2011 in Neu-Ulm / Veranst.: Ausschuss für Blitzschutz und Blitzforschung (ABB) im VDE Verband der Elektrotechnik Elektronik Informationstechnik e.V. Wiss. Tagungsleitung: K. Stimper Y1 - 2011 SN - 978-3-8007-3380-4 N1 - VDE/ABB-Blitzschutztagung ; (9 ; 2011.10.27-28 ; Neu-Ulm) SP - 7 EP - 12 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Karamanidis, Kiros A1 - Albracht, Kirsten A1 - Braunstein, Bjoern A1 - Catala, Maria Moreno A1 - Goldmann, Jan-Peter A1 - Brüggemann, Gert-Peter T1 - Lower leg musculoskeletal geometry and sprint performance JF - Gait and Posture N2 - The purpose of this study was to investigate whether sprint performance is related to lower leg musculoskeletal geometry within a homogeneous group of highly trained 100-m sprinters. Using a cluster analysis, eighteen male sprinters were divided into two groups based on their personal best (fast: N = 11, 10.30 ± 0.07 s; slow: N = 7, 10.70 ± 0.08 s). Calf muscular fascicle arrangement and Achilles tendon moment arms (calculated by the gradient of tendon excursion versus ankle joint angle) were analyzed for each athlete using ultrasonography. Achilles tendon moment arm, foot and ankle skeletal geometry, fascicle arrangement as well as the ratio of fascicle length to Achilles tendon moment arm showed no significant (p > 0.05) correlation with sprint performance, nor were there any differences in the analyzed musculoskeletal parameters between the fast and slow sprinter group. Our findings provide evidence that differences in sprint ability in world-class athletes are not a result of differences in the geometrical design of the lower leg even when considering both skeletal and muscular components. Y1 - 2011 U6 - https://doi.org/10.1016/j.gaitpost.2011.03.009 SN - 0966-6362 VL - 34 IS - 1 SP - 138 EP - 141 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kallweit, Stephan A1 - Korculanin, O. A1 - Fröhlig, F. A1 - Gabi, M. A1 - Mattern, P. T1 - Photogrammetrische Rekonstruktion von Partikelpositionen mittels Rückprojektion für 3D-PIV JF - Lasermethoden in der Strömungsmesstechnik : 19. Fachtagung, 6. - 8. September 2011, Ilmenau ; [Tagungsband enthält ... Beiträge, die anlässlich der 19. Fachtagaung "Lasermethoden in der Strömungsmesstechnik" ... vorgetragen und diskutiert wurden] / veranst. von der Deutschen Gesellschaft für Laser-Anemometrie GALA e.V. Hrsg. A. Thess... Y1 - 2011 SN - 978-3-9805613-7-2 N1 - Fachtagung Lasermethoden in der Strömungsmesstechnik <19, 2011, Ilmenau> ; Deutsche Gesellschaft für Laser-Anemometrie SP - 28/1 EP - 28/6 PB - Dt. Ges. für Laser-AnemometrieGALA e. V. CY - Karlsruhe ER - TY - JOUR A1 - Jordan, Sabine D. A1 - Krüger, Markus A1 - Willmes, Diana M. A1 - Redemann, Nora A1 - Wunderlich, F. Thomas A1 - Brönneke, Hella S. A1 - Merkwirth, Carsten A1 - Kashkar, Hamid A1 - Olkkonen, Vesa M. A1 - Böttger, Thomas A1 - Braun, Thomas A1 - Seibler, Jost A1 - Brüning, Jens C. T1 - Obesity-induced overexpression of miRNA-143 inhibits insulin-stimulated AKT activation and impairs glucose metabolism JF - Nature Cell Biology N2 - The contribution of altered post-transcriptional gene silencing to the development of insulin resistance and type 2 diabetes mellitus so far remains elusive. Here, we demonstrate that expression of microRNA (miR)-143 and 145 is upregulated in the liver of genetic and dietary mouse models of obesity. Induced transgenic overexpression of miR-143, but not miR-145, impairs insulin-stimulated AKT activation and glucose homeostasis. Conversely, mice deficient for the miR-143–145 cluster are protected from the development of obesity-associated insulin resistance. Quantitative-mass-spectrometry-based analysis of hepatic protein expression in miR-143-overexpressing mice revealed miR-143-dependent downregulation of oxysterol-binding-protein-related protein (ORP) 8. Reduced ORP8 expression in cultured liver cells impairs the ability of insulin to induce AKT activation, revealing an ORP8-dependent mechanism of AKT regulation. Our experiments provide direct evidence that dysregulated post-transcriptional gene silencing contributes to the development of obesity-induced insulin resistance, and characterize the miR-143–ORP8 pathway as a potential target for the treatment of obesity-associated diabetes. Y1 - 2011 U6 - https://doi.org/10.1038/ncb2211 SN - 1465-7392 VL - 13 IS - 4 SP - 434 EP - 446 PB - Nature CY - New York ER -