TY - JOUR A1 - Dantism, Shahriar A1 - Röhlen, Desiree A1 - Wagner, Torsten A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - A LAPS-based differential sensor for parallelized metabolism monitoring of various bacteria JF - Sensors N2 - Monitoring the cellular metabolism of bacteria in (bio)fermentation processes is crucial to control and steer them, and to prevent undesired disturbances linked to metabolically inactive microorganisms. In this context, cell-based biosensors can play an important role to improve the quality and increase the yield of such processes. This work describes the simultaneous analysis of the metabolic behavior of three different types of bacteria by means of a differential light-addressable potentiometric sensor (LAPS) set-up. The study includes Lactobacillus brevis, Corynebacterium glutamicum, and Escherichia coli, which are often applied in fermentation processes in bioreactors. Differential measurements were carried out to compensate undesirable influences such as sensor signal drift, and pH value variation during the measurements. Furthermore, calibration curves of the cellular metabolism were established as a function of the glucose concentration or cell number variation with all three model microorganisms. In this context, simultaneous (bio)sensing with the multi-organism LAPS-based set-up can open new possibilities for a cost-effective, rapid detection of the extracellular acidification of bacteria on a single sensor chip. It can be applied to evaluate the metabolic response of bacteria populations in a (bio)fermentation process, for instance, in the biogas fermentation process. Y1 - 2019 U6 - https://doi.org/10.3390/s19214692 SN - 1424-8220 VL - 19 IS - 21 PB - MDPI CY - Basel ER - TY - JOUR A1 - Karschuck, T. L. A1 - Filipov, Y. A1 - Bollella, P. A1 - Schöning, Michael Josef A1 - Katz, E. T1 - Not-XOR (NXOR) logic gate based on an enzyme-catalyzed reaction JF - International Journal of Unconventional Computing N2 - Enzyme-catalyzed reactions have been designed to mimic various Boolean logic gates in the general framework of unconventional biomolecular computing. While some of the logic gates, particularly OR, AND, are easy to realize with biocatalytic reactions and have been reported in numerous publications, some other, like NXOR, are very challenging and have not been realized yet with enzyme reactions. The paper reports on a novel approach to mimicking the NXOR logic gate using the bell-shaped enzyme activity dependent on pH values. Shifting pH from the optimum value to the acidic or basic values by using acid or base inputs (meaning 1,0 and 0,1 inputs) inhibits the enzyme reaction, while keeping the optimum pH (assuming 0,0 and 1,1 input combinations) preserves a high enzyme activity. The challenging part of the present approach is the selection of an enzyme with a well-demonstrated bell-shape activity dependence on the pH value. While many enzymes can satisfy this condition, we selected pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase as this enzyme has the optimum pH center-located on the pH scale allowing the enzyme activity change by the acidic and basic pH shift from the optimum value corresponding to the highest activity. The present NXOR gate is added to the biomolecular “toolbox” as a new example of Boolean logic gates based on enzyme reactions. Y1 - 2019 SN - 1548-7199 VL - 14 IS - 3-4 SP - 235 EP - 242 PB - Old City Publishing CY - Philadelphia ER - TY - JOUR A1 - Kreyer, Jörg A1 - Müller, Marvin A1 - Esch, Thomas T1 - A Calculation Methodology for Predicting Exhaust Mass Flows and Exhaust Temperature Profiles for Heavy-Duty Vehicles JF - SAE International Journal of Commercial Vehicles N2 - The predictive control of commercial vehicle energy management systems, such as vehicle thermal management or waste heat recovery (WHR) systems, are discussed on the basis of information sources from the field of environment recognition and in combination with the determination of the vehicle system condition. In this article, a mathematical method for predicting the exhaust gas mass flow and the exhaust gas temperature is presented based on driving data of a heavy-duty vehicle. The prediction refers to the conditions of the exhaust gas at the inlet of the exhaust gas recirculation (EGR) cooler and at the outlet of the exhaust gas aftertreatment system (EAT). The heavy-duty vehicle was operated on the motorway to investigate the characteristic operational profile. In addition to the use of road gradient profile data, an evaluation of the continuously recorded distance signal, which represents the distance between the test vehicle and the road user ahead, is included in the prediction model. Using a Fourier analysis, the trajectory of the vehicle speed is determined for a defined prediction horizon. To verify the method, a holistic simulation model consisting of several hierarchically structured submodels has been developed. A map-based submodel of a combustion engine is used to determine the EGR and EAT exhaust gas mass flows and exhaust gas temperature profiles. All simulation results are validated on the basis of the recorded vehicle and environmental data. Deviations from the predicted values are analyzed and discussed. Y1 - 2020 U6 - https://doi.org/10.4271/02-13-02-0009 SN - 1946-3928 VL - 13 IS - 2 SP - 129 EP - 143 PB - SAE International CY - Warrendale, Pa. ER - TY - JOUR A1 - Fagan, Andrew J. A1 - Bitz, Andreas A1 - Björkman-Burtscher, Isabella M. A1 - Collins, Christopher M. A1 - Kimbrell, Vera A1 - Raaijmakers, Alexander J. E. T1 - 7T MR Safety JF - Journal of Magnetic Resonance Imaging (JMRI) Y1 - 2021 U6 - https://doi.org/10.1002/jmri.27319 SN - 1522-2586 VL - 53 IS - 2 SP - 333 EP - 346 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Henriques, A. A1 - Jurado, B. A1 - Grieser, M. A1 - Denis-Petit, D. A1 - Chiron, T. A1 - Gaudefroy, L. A1 - Glorius, J. A1 - Langer, Christoph A1 - Litvinov, Yu. A. A1 - Mathieu, L. A1 - Meot, V. A1 - Perez-Sanchez, R. A1 - Pibernat, J. A1 - Reifarth, R. A1 - Roig, O. A1 - Thomas, B. A1 - Thomas, B. A. A1 - Thomas, J. C. A1 - Tsekhanovich, I. T1 - Indirect measurements of neutron cross-secti at heavy-ion storage rings JF - Journal of Physics: Conference Series N2 - Cross sections for neutron-induced reactions of short-lived nuclei are essential for nuclear astrophysics since these reactions in the stars are responsible for the production of most heavy elements in the universe. These reactions are also key in applied domains like energy production and medicine. Nevertheless, neutron-induced cross-section measurements can be extremely challenging or even impossible to perform due to the radioactivity of the targets involved. Indirect measurements through the surrogate-reaction method can help to overcome these difficulties. The surrogate-reaction method relies on the use of an alternative reaction that will lead to the formation of the same excited nucleus as in the neutron-induced reaction of interest. The decay probabilities (for fission, neutron and gamma-ray emission) of the nucleus produced via the surrogate reaction allow one to constrain models and the prediction of the desired neutron cross sections. We propose to perform surrogate reaction measurements in inverse kinematics at heavy-ion storage rings, in particular at the CRYRING@ESR of the GSI/FAIR facility. We present the conceptual idea of the most promising setup to measure for the first time simultaneously the fission, neutron and gamma-ray emission probabilities. The results of the first simulations considering the 238U(d,d') reaction are shown, as well as new technical developments that are being carried out towards this set-up. Y1 - 2020 U6 - https://doi.org/10.1088/1742-6596/1668/1/012019 VL - 1668 IS - Art. 012019 PB - IOP CY - Bristol ER - TY - JOUR A1 - Varga, Laszlo A1 - Davinson, Thomas A1 - Glorius, Jan A1 - Jurado, Beatrix A1 - Langer, Christoph A1 - Lederer-Woods, Claudia A1 - Litvinov, Yuri A. A1 - Reifarth, Rene A1 - Slavkovska, Zuzana A1 - Stöhlker, Thomas A1 - Woods, Phil J. A1 - Xing, Yuan Ming T1 - Towards background-free studies of capture reaction in a heavy-ion storage ring JF - Journal of Physics: Conference Series N2 - Stored and cooled, highly-charged ions offer unprecedented capabilities for precision studies in the realm of atomic, nuclear structure and astrophysics[1]. After the successful investigation of the 96Ru(p,7)97Rh reaction cross section in 2009[2], the first measurement of the 124Xe(p,7)125Cs reaction cross section has been performed with decelerated, fully-ionized 124Xe ions in 2016 at the Experimental Storage Ring (ESR) of GSI[3]. Using a Double Sided Silicon Strip Detector, introduced directly into the ultra-high vacuum environment of a storage ring, the 125Cs proton-capture products have been successfully detected. The cross section has been measured at 5 different energies between 5.5AMeV and 8AMeV, on the high energy tail of the Gamow-window for hot, explosive scenarios such as supernovae and X-ray binaries. The elastic scattering on the H2 gas jet target is the major source of background to count the (p,7) events. Monte Carlo simulations show that an additional slit system in the ESR in combination with the energy information of the Si detector will enable background free measurements of the proton-capture products. The corresponding hardware is being prepared and will increase the sensitivity of the method tremendously. Y1 - 2020 VL - 1668 IS - Art 012046 PB - IOP CY - Bristol ER - TY - JOUR A1 - Quittmann, Oliver J. A1 - Meskemper, Joshua A1 - Albracht, Kirsten A1 - Abel, Thomas A1 - Foitschik, Tina A1 - Strüder, Heiko K. T1 - Normalising surface EMG of ten upper-extremity muscles in handcycling: Manual resistance vs. sport-specific MVICs JF - Journal of Electromyography and Kinesiology N2 - Muscular activity in terms of surface electromyography (sEMG) is usually normalised to maximal voluntary isometric contractions (MVICs). This study aims to compare two different MVIC-modes in handcycling and examine the effect of moving average window-size. Twelve able-bodied male competitive triathletes performed ten MVICs against manual resistance and four sport-specific trials against fixed cranks. sEMG of ten muscles [M. trapezius (TD); M. pectoralis major (PM); M. deltoideus, Pars clavicularis (DA); M. deltoideus, Pars spinalis (DP); M. biceps brachii (BB); M. triceps brachii (TB); forearm flexors (FC); forearm extensors (EC); M. latissimus dorsi (LD) and M. rectus abdominis (RA)] was recorded and filtered using moving average window-sizes of 150, 200, 250 and 300 ms. Sport-specific MVICs were higher compared to manual resistance for TB, DA, DP and LD, whereas FC, TD, BB and RA demonstrated lower values. PM and EC demonstrated no significant difference between MVIC-modes. Moving average window-size had no effect on MVIC outcomes. MVIC-mode should be taken into account when normalised sEMG data are illustrated in handcycling. Sport-specific MVICs seem to be suitable for some muscles (TB, DA, DP and LD), but should be augmented by MVICs against manual/mechanical resistance for FC, TD, BB and RA. Y1 - 2020 U6 - https://doi.org/10.1016/j.jelekin.2020.102402 SN - 1050-6411 VL - 51 IS - Article 102402 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wollbrink, Moritz A1 - Maslo, Semir A1 - Zimmer, Daniel A1 - Abbas, Karim A1 - Arntz, Kristian A1 - Bergs, Thomas T1 - Clamping and substrate plate system for continuous additive build-up and post-processing of metal parts JF - Procedia CIRP N2 - The manufacturing share of laser powder bed fusion (L-PBF) increases in industrial application, but still many process steps are manually operated. Additionally, it is not possible to achieve tight dimensional tolerances or low surfaces roughness. Hence, a process chain has to be set up to combine additive manufacturing (AM) with further machining technologies. To achieve a continuous workpiece flow as basis for further industrialization of L-PBF, the paper presents a novel substrate system and its application on L-PBF machines and post-processing. The substrate system consists of a zero-point clamping system and a matrix-like interface of contact pins to be substantially connected to the workpiece within the L-PBF process. Y1 - 2020 U6 - https://doi.org/10.1016/j.procir.2020.04.015 SN - 2212-8271 VL - 93 SP - 108 EP - 113 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Meyer, Max-Arno A1 - Granrath, Christian A1 - Feyerl, Günter A1 - Richenhagen, Johannes A1 - Kaths, Jakob A1 - Andert, Jakob T1 - Closed-loop platoon simulation with cooperative intelligent transportation systems based on vehicle-to-X communication JF - Simulation Modelling Practice and Theory Y1 - 2021 U6 - https://doi.org/10.1016/j.simpat.2020.102173 SN - 1569-190X VL - 106 IS - Art. 102173 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Serror, Martin A1 - Hack, Sacha A1 - Henze, Martin A1 - Schuba, Marko A1 - Wehrle, Klaus T1 - Challenges and Opportunities in Securing the Industrial Internet of Things JF - IEEE Transactions on Industrial Informatics Y1 - 2021 U6 - https://doi.org/10.1109/TII.2020.3023507 SN - 1941-0050 VL - 17 IS - 5 SP - 2985 EP - 2996 PB - IEEE CY - New York ER - TY - JOUR A1 - Kopp, Alexander A1 - Schunck, Laura A1 - Gosau, Martin A1 - Smeets, Ralf A1 - Burg, Simon A1 - Fuest, Sandra A1 - Kröger, Nadja A1 - Zinser, Max A1 - Krohn, Sebastian A1 - Behbahani, Mehdi A1 - Köpf, Marius A1 - Lauts, Lisa A1 - Rutkowski, Rico T1 - Influence of the casting concentration on the mechanical and optical properties of Fa/CaCl2-derived silk fibroin membranes JF - International Journal of Molecular Sciences N2 - In this study, we describe the manufacturing and characterization of silk fibroin membranes derived from the silkworm Bombyx mori. To date, the dissolution process used in this study has only been researched to a limited extent, although it entails various potential advantages, such as reduced expenses and the absence of toxic chemicals in comparison to other conventional techniques. Therefore, the aim of this study was to determine the influence of different fibroin concentrations on the process output and resulting membrane properties. Casted membranes were thus characterized with regard to their mechanical, structural and optical assets via tensile testing, SEM, light microscopy and spectrophotometry. Cytotoxicity was evaluated using BrdU, XTT, and LDH assays, followed by live–dead staining. The formic acid (FA) dissolution method was proven to be suitable for the manufacturing of transparent and mechanically stable membranes. The fibroin concentration affects both thickness and transparency of the membranes. The membranes did not exhibit any signs of cytotoxicity. When compared to other current scientific and technical benchmarks, the manufactured membranes displayed promising potential for various biomedical applications. Further research is nevertheless necessary to improve reproducible manufacturing, including a more uniform thickness, less impurity and physiological pH within the membranes. Y1 - 2020 U6 - https://doi.org/10.3390/ijms21186704 SN - 1422-0067 N1 - Special issue: Optimization of Biomaterials for Reconstructive and Regenerative Medicine VL - 21 IS - 18 art. no. 6704 PB - MDPI CY - Basel ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Clemens, Markus A1 - Bitz, Andreas T1 - Safety of subjects during radiofrequency exposure in ultra-high-field magnetic resonance imaging JF - IEEE Letters on Electromagnetic Compatibility Practice and Applications N2 - Magnetic resonance imaging (MRI) is one of the most important medical imaging techniques. Since the introduction of MRI in the mid-1980s, there has been a continuous trend toward higher static magnetic fields to obtain i.a. a higher signal-to-noise ratio. The step toward ultra-high-field (UHF) MRI at 7 Tesla and higher, however, creates several challenges regarding the homogeneity of the spin excitation RF transmit field and the RF exposure of the subject. In UHF MRI systems, the wavelength of the RF field is in the range of the diameter of the human body, which can result in inhomogeneous spin excitation and local SAR hotspots. To optimize the homogeneity in a region of interest, UHF MRI systems use parallel transmit systems with multiple transmit antennas and time-dependent modulation of the RF signal in the individual transmit channels. Furthermore, SAR increases with increasing field strength, while the SAR limits remain unchanged. Two different approaches to generate the RF transmit field in UHF systems using antenna arrays close and remote to the body are investigated in this letter. Achievable imaging performance is evaluated compared to typical clinical RF transmit systems at lower field strength. The evaluation has been performed under consideration of RF exposure based on local SAR and tissue temperature. Furthermore, results for thermal dose as an alternative RF exposure metric are presented. Y1 - 2020 SN - 2637-6423 U6 - https://doi.org/10.1109/LEMCPA.2020.3029747 VL - 2 IS - 3 SP - 1 EP - 8 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Molinnus, Denise A1 - Beging, Stefan A1 - Lowis, Carsten A1 - Schöning, Michael Josef T1 - Towards a multi-enzyme capacitive field-effect biosensor by comparative study of drop-coating and nano-spotting technique JF - Sensors N2 - Multi-enzyme immobilization onto a capacitive field-effect biosensor by nano-spotting technique is presented. The nano-spotting technique allows to immobilize different enzymes simultaneously on the sensor surface with high spatial resolution without additional photolithographical patterning. The amount of applied enzymatic cocktail on the sensor surface can be tailored. Capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors with Ta2O5 as pH-sensitive transducer layer have been chosen to immobilize the three different (pL droplets) enzymes penicillinase, urease, and glucose oxidase. Nano-spotting immobilization is compared to conventional drop-coating method by defining different geometrical layouts on the sensor surface (fully, half-, and quarter-spotted). The drop diameter is varying between 84 µm and 102 µm, depending on the number of applied drops (1 to 4) per spot. For multi-analyte detection, penicillinase and urease are simultaneously nano-spotted on the EIS sensor. Sensor characterization was performed by C/V (capacitance/voltage) and ConCap (constant capacitance) measurements. Average penicillin, glucose, and urea sensitivities for the spotted enzymes were 81.7 mV/dec, 40.5 mV/dec, and 68.9 mV/dec, respectively. Y1 - 2020 SN - 1424-8220 U6 - https://doi.org/10.3390/s20174924 N1 - Special issue: Multisensor Systems and Signal Processing in Analytical Chemistry VL - 20 IS - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Hüning, Felix A1 - Backes, Andreas T1 - Direct observation of large Barkhausen jump in thin Vicalloy wires JF - IEEE Magnetics Letters Y1 - 2020 SN - 1949-307X U6 - https://doi.org/10.1109/LMAG.2020.3046411 VL - 11 IS - Art. 2506504 SP - 1 EP - 4 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Gazda, Quentin A1 - Maurischat, Andreas T1 - Special functions and Gauss-Thakur sums in higher rank and dimension Y1 - 2020 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Conzen, Catharina A1 - Albanna, Walid A1 - Weiss, Miriam A1 - Kürten, David A1 - Vilser, Walthard A1 - Kotliar, Konstantin A1 - Zäske, Charlotte A1 - Clusmann, Hans A1 - Schubert, Gerrit Alexander T1 - Vasoconstriction and Impairment of Neurovascular Coupling after Subarachnoid Hemorrhage: a Descriptive Analysis of Retinal Changes JF - Translational Stroke Research N2 - Impaired cerebral autoregulation and neurovascular coupling (NVC) contribute to delayed cerebral ischemia after subarachnoid hemorrhage (SAH). Retinal vessel analysis (RVA) allows non-invasive assessment of vessel dimension and NVC hereby demonstrating a predictive value in the context of various neurovascular diseases. Using RVA as a translational approach, we aimed to assess the retinal vessels in patients with SAH. RVA was performed prospectively in 24 patients with acute SAH (group A: day 5–14), in 11 patients 3 months after ictus (group B: day 90 ± 35), and in 35 age-matched healthy controls (group C). Data was acquired using a Retinal Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and NVC using flicker-light excitation. Diameter of retinal vessels—central retinal arteriolar and venular equivalent—was significantly reduced in the acute phase (p < 0.001) with gradual improvement in group B (p < 0.05). Arterial NVC of group A was significantly impaired with diminished dilatation (p < 0.001) and reduced area under the curve (p < 0.01) when compared to group C. Group B showed persistent prolonged latency of arterial dilation (p < 0.05). Venous NVC was significantly delayed after SAH compared to group C (A p < 0.001; B p < 0.05). To our knowledge, this is the first clinical study to document retinal vasoconstriction and impairment of NVC in patients with SAH. Using non-invasive RVA as a translational approach, characteristic patterns of compromise were detected for the arterial and venous compartment of the neurovascular unit in a time-dependent fashion. Recruitment will continue to facilitate a correlation analysis with clinical course and outcome. Y1 - 2018 U6 - https://doi.org/10.1007/s12975-017-0585-8 SN - 1868-601X IS - 9 SP - 284 EP - 293 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Bernecker, Andreas A1 - Boyer, Pierre C. A1 - Gathmann, Christina T1 - The Role of Electoral Incentives for Policy Innovation: Evidence from the US Welfare Reform JF - American Economic Journal: Economic Policy Y1 - 2021 U6 - https://doi.org/10.1257/pol.20190690 SN - 1945-774X VL - 13 IS - 2 SP - 26 EP - 57 PB - American Economic Association CY - Nashville, Tenn. ER - TY - JOUR A1 - Hugenroth, Kristin A1 - Borchardt, Ralf A1 - Ritter, Philine A1 - Groß‑Hardt, Sascha A1 - Meyns, Bart A1 - Verbelen, Tom A1 - Steinseifer, Ulrich A1 - Kaufmann, Tim A. S. A1 - Engelmann, Ulrich M. T1 - Optimizing cerebral perfusion and hemodynamics during cardiopulmonary bypass through cannula design combining in silico, in vitro and in vivo input JF - Scientific Reports N2 - Cardiopulmonary bypass (CPB) is a standard technique for cardiac surgery, but comes with the risk of severe neurological complications (e.g. stroke) caused by embolisms and/or reduced cerebral perfusion. We report on an aortic cannula prototype design (optiCAN) with helical outflow and jet-splitting dispersion tip that could reduce the risk of embolic events and restores cerebral perfusion to 97.5% of physiological flow during CPB in vivo, whereas a commercial curved-tip cannula yields 74.6%. In further in vitro comparison, pressure loss and hemolysis parameters of optiCAN remain unaffected. Results are reproducibly confirmed in silico for an exemplary human aortic anatomy via computational fluid dynamics (CFD) simulations. Based on CFD simulations, we firstly show that optiCAN design improves aortic root washout, which reduces the risk of thromboembolism. Secondly, we identify regions of the aortic intima with increased risk of plaque release by correlating areas of enhanced plaque growth and high wall shear stresses (WSS). From this we propose another easy-to-manufacture cannula design (opti2CAN) that decreases areas burdened by high WSS, while preserving physiological cerebral flow and favorable hemodynamics. With this novel cannula design, we propose a cannulation option to reduce neurological complications and the prevalence of stroke in high-risk patients after CPB. Y1 - 2021 U6 - https://doi.org/10.1038/s41598-021-96397-2 SN - 2045-2322 VL - 11 IS - Art. No. 16800 SP - 1 EP - 12 PB - Springer CY - Berlin ER - TY - JOUR A1 - Brockhaus, Moritz K. A1 - Behbahani, Mehdi A1 - Muris, Farina A1 - Jansen, Sebastian V. A1 - Schmitz- Rode, Thomas A1 - Steinseifer, Ulrich A1 - Clauser, Johanna C. T1 - In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept JF - Artificial Organs N2 - Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential. Y1 - 2021 U6 - https://doi.org/10.1111/aor.14046 SN - 1525-1594 VL - 45 IS - 12 SP - 1513 EP - 1521 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Albracht, Kirsten T1 - Adaptational responses of the human Achilles tendon by modulation of the applied cyclic strain magnitude JF - Journal of Experimental Biology Y1 - 2007 U6 - https://doi.org/10.1242/jeb.003814 SN - 0022-0949 VL - 210 IS - 15 SP - 2743 EP - 2753 ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Influence of the mechanical properties of the muscle-tendon unit on force generation in runners with different running economy JF - Biological Cybernetics Y1 - 2006 U6 - https://doi.org/10.1007/s00422-006-0070-z SN - 1432-0770 VL - 95 IS - 1 SP - 87 EP - 96 ER - TY - JOUR A1 - Sousa, Marcos A. M. A1 - Siqueira, Jose R. Jr. A1 - Vercik, Andres A1 - Schöning, Michael Josef A1 - Oliveira, Osvaldo N. Jr. T1 - Determining the optimized layer-by-layer film architecture with dendrimer/carbon nanotubes for field-effect sensors JF - IEEE Sensors Journal N2 - The capacitive electrolyte–insulator–semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte–insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors. Y1 - 2017 U6 - https://doi.org/10.1109/JSEN.2017.2653238 SN - 1558-1748 VL - 17 IS - 6 SP - 1735 EP - 1740 PB - IEEE CY - New York ER - TY - JOUR A1 - Reinhardt, T. A1 - Bitz, Andreas A1 - El Ouardi, A. A1 - Streckert, J. A1 - Sommer, A. A1 - Lerchl, A. A1 - Hansen, V. T1 - Exposure set-ups for in vivo experiments using radial waveguides JF - Radiation Protection Dosimetry Y1 - 2007 U6 - https://doi.org/10.1093/rpd/ncm370 SN - 1742-3406 VL - 124 IS - 1 SP - 21 EP - 26 ER - TY - JOUR A1 - Sommer, Angela M. A1 - Bitz, Andreas A1 - Streckert, Joachim A1 - Hansen, Volkert W. A1 - Lerchl, Alexander T1 - Lymphoma development in mice chronically exposed to UMTS-modulated radiofrequency electromagnetic fields JF - Radiation Research Y1 - 2007 U6 - https://doi.org/10.1667/RR0857.1 SN - 1938-5404 VL - 168 IS - 1 SP - 72 EP - 80 ER - TY - JOUR A1 - Sukhotina, Irina A1 - Streckert, Joachim R. A1 - Bitz, Andreas A1 - Hansen, Volkert W. A1 - Lerchl, Alexander T1 - 1800 MHz electromagnetic field effects on melatonin release from isolated pineal glands JF - Journal of Pineal Research Y1 - 2006 U6 - https://doi.org/10.1111/j.1600-079X.2005.00284.x SN - 1600-079X VL - 40 IS - 1 SP - 86 EP - 91 ER - TY - JOUR A1 - Franke, Helmut A1 - Streckert, Joachim A1 - Bitz, Andreas A1 - Goeke, Johannes A1 - Hansen, Volkert A1 - Ringelstein, E. Bernd A1 - Nattkämper, Heiner A1 - Galle, Hans-Joachim A1 - Stögbauer, Florian T1 - Effects of Universal Mobile Telecommunications System (UMTS) electromagnetic fields on the blood-brain barrier in vitro JF - Radiation Research Y1 - 2005 U6 - https://doi.org/10.1667/RR3424.1 SN - 1938-5404 VL - 164 IS - 3 SP - 258 EP - 269 ER - TY - JOUR A1 - Wissen, M. A1 - Bogdanski, N. A1 - Scheer, H.-C. A1 - Bitz, Andreas A1 - Ahrens, G. A1 - Gruetzner, G. T1 - Implication of the light polarisation for UV curing of pre-patterned resists JF - Microelectronic Engineering Y1 - 2005 U6 - https://doi.org/10.1016/j.mee.2004.12.099 SN - 0167-9317 VL - 78-79 SP - 659 EP - 664 ER - TY - JOUR A1 - Ndoumbè Mbonjo Mbonjo, H. A1 - Streckert, J. A1 - Bitz, Andreas A1 - Hansen, V. A1 - Glasmachers, A. A1 - Gencol, S. A1 - Rozic, D. T1 - Generic UMTS test signal for RF bioelectromagnetic studies JF - Bioelectromagnetics Y1 - 2004 U6 - https://doi.org/10.1002/bem.20007 SN - 1521-186X VL - 25 IS - 6 SP - 415 EP - 425 ER - TY - JOUR A1 - Sommer, Angela M. A1 - Streckert, Joachim A1 - Bitz, Andreas A1 - Hansen, Volkert W. A1 - Lerchl, Alexander T1 - No effects of GSM-modulated 900 MHz electromagnetic fields on survival rate and spontaneous development of lymphoma in female AKR/J mice JF - BMC Cancer Y1 - 2004 U6 - https://doi.org/10.1186/1471-2407-4-77 VL - 77 IS - 4 ER - TY - JOUR A1 - Hansen, Volkert W. A1 - Bitz, Andreas A1 - Streckert, Joachim R. T1 - RF Exposure of Biological Systems in Radial Waveguides JF - IEEE Transactions on Electromagnetic Compatibility Y1 - 1999 U6 - https://doi.org/10.1109/15.809852 SN - 1558-187X VL - 41 IS - 4 SP - 487 EP - 493 ER - TY - JOUR A1 - Arreola, Julio A1 - Oberländer, Jan A1 - Mätzkow, M. A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Surface functionalization for spore-based biosensors with organosilanes JF - Electrochimica Acta N2 - In the present work, surface functionalization of different sensor materials was studied. Organosilanes are well known to serve as coupling agent for biomolecules or cells on inorganic materials. 3-aminopropyltriethoxysilane (APTES) was used to attach microbiological spores time to an interdigitated sensor surface. The functionality and physical properties of APTES were studied on isolated sensor materials, namely silicon dioxide (SiO2) and platinum (Pt) as well as the combined material on sensor level. A predominant immobilization of spores could be demonstrated on SiO2 surfaces. Additionally, the impedance signal of APTES-functionalized biosensor chips has been investigated. Y1 - 2017 U6 - https://doi.org/10.1016/j.electacta.2017.04.157 SN - 0013-4686 VL - 241 SP - 237 EP - 243 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Rieke, Christian A1 - Stollenwerk, Dominik A1 - Dahmen, Markus A1 - Pieper, Martin T1 - Modeling and optimization of a biogas plant for a demand-driven energy supply JF - Energy N2 - Due to the Renewable Energy Act, in Germany it is planned to increase the amount of renewable energy carriers up to 60%. One of the main problems is the fluctuating supply of wind and solar energy. Here biogas plants provide a solution, because a demand-driven supply is possible. Before running such a plant, it is necessary to simulate and optimize the process. This paper provides a new model of a biogas plant, which is as accurate as the standard ADM1 model. The advantage compared to ADM1 is that it is based on only four parameters compared to 28. Applying this model, an optimization was installed, which allows a demand-driven supply by biogas plants. Finally the results are confirmed by several experiments and measurements with a real test plant. Y1 - 2018 U6 - https://doi.org/10.1016/j.energy.2017.12.073 SN - 0360-5442 VL - 145 SP - 657 EP - 664 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Oberländer, Jan A1 - Mayer, Marlena A1 - Greeff, Anton A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Spore-based biosensor to monitor the microbicidal efficacy of gaseous hydrogen peroxide sterilization processes JF - Biosensors and Bioelectronics N2 - In this work, a spore-based biosensor is evaluated to monitor the microbicidal efficacy of sterilization processes applying gaseous hydrogen peroxide (H2O2). The sensor is based on interdigitated electrode structures (IDEs) that have been fabricated by means of thin-film technologies. Impedimetric measurements are applied to study the effect of sterilization process on spores of Bacillus atrophaeus. This resilient microorganism is commonly used in industry to proof the sterilization efficiency. The sensor measurements are accompanied by conventional microbiological challenge tests, as well as morphological characterizations with scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The sensor measurements are correlated with the microbiological test routines. In both methods, namely the sensor-based and microbiological one, a tailing effect has been observed. The results are evaluated and discussed in a three-dimensional calibration plot demonstrating the sensor's suitability to enable a rapid process decision in terms of a successfully performed sterilization. Y1 - 2018 U6 - https://doi.org/10.1016/j.bios.2017.12.045 SN - 0956-5663 VL - 104 SP - 87 EP - 94 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Braband, Henrik A1 - Paulßen, Elisabeth A1 - Abram, Ulrich T1 - Nitridorhenium(V) Complexes with 1,3-Dialkyl-4,5-dimethylimidazole-2-ylidenes JF - Zeitschrift für anorganische und allgemeine Chemie : ZAAC = Journal of inorganic and general chemistry Y1 - 2006 U6 - https://doi.org/10.1002/zaac.200600002 SN - 1521-3749 VL - 632 IS - 6 SP - 1051 EP - 1056 ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Schweighöfer, Philip V. A1 - Abram, Ulrich T1 - Reactions of [ReOX3(PPh3)2] Complexes (X = Cl, Br) with Phenylacetylene and the Structures of the Products JF - Zeitschrift für anorganische und allgemeine Chemie : ZAAC = Journal of inorganic and general chemistry N2 - Oxorhenium(V) complexes [ReOX3(PPh3)2] (X = Cl, Br) react with phenylacetylene under formation of complexes with ylide-type ligands. Compounds of the compositions [ReOCl3(PPh3){C(Ph)C(H)(PPh3)}] (1), [ReOBr3(OPPh3){C(Ph)C(H)(PPh3)}] (2), and [ReOBr3(OPPh3){C(H)C(Ph)(PPh3)}] (3) were isolated and characterized by X-ray diffraction. They contain a ligand, which was formed by a nucleophilic attack of released PPh3 at coordinated phenylacetylene. The structures of the products show that there is no preferable position for this attack. Cleavage of the Re–C bond in 3 and dimerization of the organic ligand resulted in the formation of the [{(PPh3)(H)CC(Ph)}2]2+ cation, which crystallized as its [(ReOBr4)(OReO3)]2– salt. Y1 - 2010 U6 - https://doi.org/10.1002/zaac.200900478 SN - 1521-3749 VL - 636 IS - 5 SP - 779 EP - 783 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Kückmann, Theresa A1 - Abram, Ulrich T1 - Silver(I) Complexes of 1,3-Dialkyl-4,5-dimethylimidazol-2-ylidenes and their Use as Precursors for the Synthesis of Rhenium(V) NHC Complexes JF - Zeitschrift für anorganische und allgemeine Chemie : ZAAC = Journal of inorganic and general chemistry Y1 - 2007 U6 - https://doi.org/10.1002/zaac.200700021 SN - 1521-3749 VL - 633 IS - 5-6 SP - 830 EP - 834 ER - TY - JOUR A1 - Braband, Henrik A1 - Yegen, Eda A1 - Paulßen, Elisabeth A1 - Abram, Ulrich T1 - [{ReN(PMe2Ph)3}{ReO3N}]2 – Structural Evidence for the Nitridotrioxorhenate(VII) Anion, [ReO3N]2− JF - Zeitschrift für anorganische und allgemeine Chemie : ZAAC = Journal of inorganic and general chemistry Y1 - 2005 U6 - https://doi.org/10.1002/zaac.200500240 SN - 1521-3749 VL - 631 IS - 12 SP - 2408 EP - 2410 ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Alberto, Roger A1 - Abram, Ulrich T1 - Synthesis, Characterization, and Structures of R3EOTcO3 Complexes (E = C, Si, Ge, Sn, Pb) and Related Compounds JF - Inorganic Chemistry N2 - AgTcO4 reacts with R3ECl compounds (E = C, Si, Ge, Sn, Pb; R = Me, iPr, tBu, Ph), tBu2SnCl2, or PhMgCl under formation of novel trioxotechnetium(VII) derivatives. The carbon and silicon derivatives readily undergo decomposition, which was proven by 99Tc NMR spectroscopy and the isolation of decomposition products such as [TcOCl3(THF)(OH2)]. Compounds [Ph3GeOTcO3], [(THF)Ph3SnOTcO3], [(O3TcO)SntBu2(OH)]2, and [(THF)4Mg(OTcO3)2] are more stable and were isolated in crystalline form and characterized by X-ray diffraction. Y1 - 2010 U6 - https://doi.org/10.1021/ic1001094 SN - 1520-510X VL - 49 IS - 7 SP - 3525 EP - 3530 PB - American Chemical Society CY - Washington ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Kong, Shushu A1 - Arciszewski, Pawel A1 - Wielbalck, Swantje A1 - Abram, Ulrich T1 - Aryl and NHC Compounds of Technetium and Rhenium JF - Journal of the American Chemical Society N2 - Air- and water-stable phenyl complexes with nitridotechnetium(V) cores can be prepared by straightforward procedures. [TcNPh2(PPh3)2] is formed by the reaction of [TcNCl2(PPh3)2] with PhLi. The analogous N-heterocyclic carbene (NHC) compound [TcNPh2(HLPh)2], where HLPh is 1,3,4-triphenyl-1,2,4-triazol-5-ylidene, is available from (NBu4)[TcNCl4] and HLPh or its methoxo-protected form. The latter compound allows the comparison of different Tc–C bonds within one compound. Surprisingly, the Tc chemistry with such NHCs does not resemble that of corresponding Re complexes, where CH activation and orthometalation dominate. Y1 - 2012 U6 - https://doi.org/10.1021/ja3033718 SN - 1520-5126 VL - 134 IS - 22 SP - 9118 EP - 9121 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Barbazán, Paula A1 - Hagenbach, Adelheid A1 - Paulßen, Elisabeth A1 - Abram, Ulrich A1 - Carballo, Rosa A1 - Rodriguez-Hermida, Sabina A1 - Vázquez-López, Ezequiel M. T1 - Tricarbonyl Rhenium(I) and Technetium(I) Complexes with Hydrazones Derived from 4,5-Diazafluoren-9-one and 1,10-Phenanthroline-5,6-dione JF - European Journal of Inorganic Chemistry N2 - Tricarbonylrhenium(I) and -technetium(I) halide (halide = Cl and Br) complexes of ligands derived from 4,5-diazafluoren-9-one (df) and 1,10-phenanthroline-5,6-dione (phen) derivatives of benzoic and 2-hydroxybenzoic acid hydrazides have been prepared. The complexes have been characterized by elemental analysis, MS, IR, 1H NMR and absorption and emission UV/Vis spectroscopic methods. The metal centres (ReI and TcI) are coordinated through the nitrogen imine atoms and establish five-membered chelate rings, whereas the hydrazone groups stand uncoordinated. The 1H NMR spectra suggest the same behaviour in solution on the basis of only marginal variations in the chemical shifts of the hydrazine protons. Y1 - 2010 U6 - https://doi.org/10.1002/ejic.201000522 SN - 1099-0682 IS - 29 SP - 4622 EP - 4630 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Ngyugen, Hung Huy A1 - Kahlcke, Nils A1 - Deflon, Victor M. A1 - Abram, Ulrich T1 - Tricarbonyltechnetium(I) and -rhenium(I) complexes with N′-thiocarbamoylpicolylbenzamidines JF - Polyhedron N2 - N,N-Dialkylamino(thiocarbonyl)-N′-picolylbenzamidines react with (NEt4)2[M(CO)3X3] (M = Re, X = Br; M = Tc, X = Cl) under formation of neutral [M(CO)3L] complexes in high yields. The monoanionic NNS ligands bind in a facial coordination mode and can readily be modified at the (CS)NR1R2 moiety. The complexes [99Tc(CO)3(LPyMor)] and [Re(CO)3(L)] (L = LPyMor, LPyEt) were characterized by X-ray diffraction. Reactions of [99mTc(CO)3(H2O)3]+ with the N′-thiocarbamoylpicolylbenzamidines give the corresponding 99mTc complexes. The ester group in HLPyCOOEt allows linkage between biomolecules and the metal core. Y1 - 2012 U6 - https://doi.org/10.1016/j.poly.2012.04.008 SN - 0277-5387 VL - 40 IS - 1 SP - 153 EP - 158 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Pellegrini, Paul A. A1 - Howell, Nicholas R. A1 - Shepherd, Rachael K. A1 - Lengkeek, Nigel A. A1 - Paulßen, Elisabeth A1 - Katsifis, Andrew G. A1 - Greguric, Ivan T1 - Synthesis and Radiolabelling of DOTA-Linked Glutamine Analogues with 67,68Ga as Markers for Increased Glutamine Metabolism in Tumour Cells JF - Molecules Y1 - 2013 U6 - https://doi.org/10.3390/molecules18067160 SN - 1420-3049 VL - 18 IS - 6 SP - 7160 EP - 7178 PB - MDPI CY - Basel ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Le, Van So A1 - Lengkeek, Nigel A1 - Pellegrini, Paul A1 - Jackson, Tim A1 - Greguric, Ivan A1 - Weiner, Ron T1 - Influence of Metal Ions on the 68Ga-labeling of DOTATATE JF - Applied Radiation and Isotopes Y1 - 2013 U6 - https://doi.org/10.1016/j.apradiso.2013.08.010 SN - 1872-9800 VL - 82 SP - 232 EP - 238 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Lengkeek, Nigel A. A1 - Le, Van So A1 - Pellegrini, Paul A. A1 - Greguric, Ivan A1 - Weiner, Ron T1 - The role of additives in moderating the influence of Fe(III) and Cu(II) on the radiochemical yield of [⁶⁸Ga(DOTATATE)] JF - Applied Radiation and Isotopes N2 - [⁶⁸Ga(DOTATATE)] has demonstrated its clinical usefulness. Both Fe³⁺ and Cu²⁺, potential contaminants in Gallium-68 generator eluent, substantially reduce the radiochemical (RC) yield of [⁶⁸Ga(DOTATATE)] if the metal/ligand ratio of 1:1 is exceeded. A variety of compounds were examined for their potential ability to reduce this effect. Most had no effect on RC yield. However, addition of phosphate diminished the influence of Fe³⁺ by likely forming an insoluble iron salt. Addition of ascorbic acid reduced Cu²⁺ and Fe³⁺ to Cu⁺ and Fe²⁺ respectively, both of which have limited impact on RC yields. At low ligand amounts (5 nmol DOTATATE), the addition of 30 nmol phosphate (0.19 mM) increased the tolerance of Fe3⁺ from 4 nmol to 10 nmol (0.06 mM), while the addition of ascorbic acid allowed high RC yields (>95%) in the presence of 40 nmol Fe³⁺ (0.25 mM) and 100 nmol Cu²⁺ (0.63 mM). The effect of ascorbic acid was highly pH-dependant, and gave optimal results at pH 3. Y1 - 2016 U6 - https://doi.org/10.1016/j.apradiso.2015.09.008 SN - 1872-9800 VL - 107 SP - 13 EP - 16 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Hoehr, Cornelia A1 - Hou, Xinchi A1 - Hanemaayer, Victoire A1 - Zeisler, Stefan A1 - Adam, Michael J. A1 - Ruth, Thomas J. A1 - Celler, Anna A1 - Buckley, Ken A1 - Benard, Francois A1 - Schaffer, Paul T1 - Production of Y-86 and other radiometals for research purposes using a solution target system JF - Nuclear medicine and biology Y1 - 2015 U6 - https://doi.org/10.1016/j.nucmedbio.2015.06.005 SN - 1872-9614 VL - 42 IS - 11 SP - 842 EP - 849 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hoehr, Cornelia A1 - Paulßen, Elisabeth A1 - Benard, Francois A1 - Lee, Chris Jaeil A1 - Hou, Xinchi A1 - Badesso, Brian A1 - Ferguson, Simon A1 - Miao, Qing A1 - Yang, Hua A1 - Buckley, Ken A1 - Hanemaayer, Victoire A1 - Zeisler, Stefan A1 - Ruth, Thomas A1 - Celler, Anna A1 - Schaffer, Paul T1 - ⁴⁴ᶢSc production using a water target on a 13 MeV cyclotron JF - Nuclear medicine and biology N2 - Access to promising radiometals as isotopes for novel molecular imaging agents requires that they are routinely available and inexpensive to obtain. Proximity to a cyclotron center outfitted with solid target hardware, or to an isotope generator for the metal of interest is necessary, both of which can introduce significant hurdles in development of less common isotopes. Herein, we describe the production of ⁴⁴Sc (t₁⸝₂ = 3.97 h, Eavg,β⁺ = 1.47 MeV, branching ratio = 94.27%) in a solution target and an automated loading system which allows a quick turn-around between different radiometallic isotopes and therefore greatly improves their availability for tracer development. Experimental yields are compared to theoretical calculations. Y1 - 2014 U6 - https://doi.org/10.1016/j.nucmedbio.2013.12.016 SN - 1872-9614 VL - 41 IS - 5 SP - 401 EP - 406 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Infantino, Angelo A1 - Paulßen, Elisabeth A1 - Mostacci, Domiziano A1 - Schaffer, Paul A1 - Trinczek, Michael A1 - Hoehr, Cornelia T1 - Assessment of the production of medical isotopes using the Monte Carlo code FLUKA: Simulations against experimental measurements JF - Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms N2 - The Monte Carlo code FLUKA is used to simulate the production of a number of positron emitting radionuclides, ¹⁸F, ¹³N, ⁹⁴Tc, ⁴⁴Sc, ⁶⁸Ga, ⁸⁶Y, ⁸⁹Zr, ⁵²Mn, ⁶¹Cu and ⁵⁵Co, on a small medical cyclotron with a proton beam energy of 13 MeV. Experimental data collected at the TR13 cyclotron at TRIUMF agree within a factor of 0.6 ± 0.4 with the directly simulated data, except for the production of ⁵⁵Co, where the simulation underestimates the experiment by a factor of 3.4 ± 0.4. The experimental data also agree within a factor of 0.8 ± 0.6 with the convolution of simulated proton fluence and cross sections from literature. Overall, this confirms the applicability of FLUKA to simulate radionuclide production at 13 MeV proton beam energy. Y1 - 2016 U6 - https://doi.org/10.1016/j.nimb.2015.10.067 SN - 1872-9584 VL - 366 SP - 117 EP - 123 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Liu, Z. A1 - Schaap, K. S. A1 - Ballemans, L. A1 - de Blois, E. A1 - Rohde, M. A1 - Paulßen, Elisabeth T1 - Measurement of reaction kinetics of [177Lu]Lu-DOTA-TATE using a microfluidic system JF - Dalton Transactions Y1 - 2017 U6 - https://doi.org/10.1039/C7DT01830D SN - 1477-9234 VL - 46 IS - 42 SP - 14669 EP - 14676 ER - TY - JOUR A1 - Schuh, G. A1 - Gottschalk, S. A1 - Höhne, Tim T1 - High Resolution Production Management JF - CIRP Annals Y1 - 2007 U6 - https://doi.org/10.1016/j.cirp.2007.05.105 SN - 0007-8506 VL - 56 IS - 1 SP - 439 EP - 442 ER - TY - JOUR A1 - Laura, C.O. A1 - Drechsler, Klaus A1 - Erdt, M. A1 - Wesarg, S. A1 - Bale, R. T1 - Intervention assessment tool for primary tumors in the liver JF - Current Directions in Biomedical Engineering N2 - After a liver tumor intervention the medical doctor has to compare both pre and postoperative CT acquisitions to ensure that all carcinogenic cells are destroyed. A correct assessment of the intervention is of vital importance, since it will reduce the probability of tumor recurrence. Some methods have been proposed to support the medical doctors during the assessment process, however, all of them focus on secondary tumors. In this paper a tool is presented that enables the outcome validation for both primary and secondary tumors. Therefore, a multiphase registration (preoperative arterial and portal phases) followed by a registration between the pre and postoperative CT images is carried out. The first registration is in charge of the primary tumors that are only visible in the arterial phase. The secondary tumors will be incorporated in the second registration step. Finally, the part of the tumor that was not covered by the necrosis is quantified and visualized. The method has been tested in 9 patients, with an average registration error of 1.41 mm. Y1 - 2018 U6 - https://doi.org/10.1515/cdbme-2018-0081 SN - 2364-5504 VL - 4 IS - 1 SP - 337 EP - 340 PB - De Gruyter CY - Berlin ER -