TY - CHAP A1 - Breuer, Lars A1 - Raue, Markus A1 - Mang, Thomas A1 - Schöning, Michael Josef A1 - Thoelen, Ronald A1 - Wagner, Torsten T1 - Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications T2 - 12. Dresdner Sensor-Symposium 2015 Y1 - 2015 U6 - http://dx.doi.org/10.5162/12dss2015/P5.8 SP - 206 EP - 209 ER - TY - CHAP A1 - Breuer, Lars A1 - Guthmann, Eric A1 - Schöning, Michael Josef A1 - Thoelen, Ronald A1 - Wagner, Torsten T1 - Light-Stimulated Hydrogels with Incorporated Graphene Oxide as Actuator Material for Flow Control in Microfluidic Applications T2 - Proceedings Eurosensors 2017 Conference, Paris, France, 3–6 September 2017 Y1 - 2017 U6 - http://dx.doi.org/10.3390/proceedings1040524 SP - 1 EP - 4 ER - TY - CHAP A1 - Braunstein, Bjoern A1 - Goldmann, Jan-Peter A1 - Albracht, Kirsten A1 - Sanno, Maximilian A1 - Willwacher, Steffen A1 - Heinrich, Kai A1 - Herrmann, Volker A1 - Brüggemann, Gert-Peter T1 - Joint specific contribution of mechanical power and work during acceleration and top speed in elite sprinters T2 - 31 International Conference on Biomechanics in Sports, Taipei, Taiwan, July 07 - July 22, 2013 Y1 - 2013 SN - 1999-4168 ER - TY - CHAP A1 - Bornheim, Tobias A1 - Grieger, Niklas A1 - Bialonski, Stephan T1 - FHAC at GermEval 2021: Identifying German toxic, engaging, and fact-claiming comments with ensemble learning T2 - Proceedings of the GermEval 2021 Workshop on the Identification of Toxic, Engaging, and Fact-Claiming Comments : 17th Conference on Natural Language Processing KONVENS 2021 Y1 - 2021 U6 - http://dx.doi.org/10.48415/2021/fhw5-x128 N1 - SP - 105 EP - 111 PB - Heinrich Heine University CY - Düsseldorf ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Living cell-based gas sensor system for the detection of acetone in air Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/3.2.3 SP - 269 EP - 272 ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Stütz, Evamaria A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Detection of toxic chromium species in water using cellbased sensor systems Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/P2.1.14 SP - 1364 EP - 1367 ER - TY - CHAP A1 - Bohrn, U. A1 - Stütz, E. A1 - Fleischer, M. A1 - Schöning, Michael Josef A1 - Wagner, P. ED - Abdelghani, Adnane ED - Schöning, Michael Josef T1 - Towards a paradigm change – mammalian cells as sensitive biosensor layers for the detection of unexpected toxic substances in air T2 - Nanoscale Science and Technology (NS&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012 Y1 - 2012 SP - 44 EP - 44 ER - TY - CHAP A1 - Blum, Yannik A1 - Albanna, Walid A1 - Benninghaus, Anne A1 - Kotliar, Konstantin ED - Staat, Manfred ED - Erni, Daniel T1 - Vasomotion in retinal vessels of patients presenting post hemorrhagic hydrocephalus following subarachnoid hemorrhage T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Clearance of blood components and fluid drainage play a crucial role in subarachnoid hemorrhage (SAH) and post hemorrhagic hydrocephalus (PHH). With the involvement of interstitial fluid (ISF) and cerebrospinal fluid (CSF), two pathways for the clearance of fluid and solutes in the brain are proposed. Starting at the level of capillaries, flow of ISF follows along the basement membranes in the walls of cerebral arteries out of the parenchyma to drain into the lymphatics and CSF [1]–[3]. Conversely, it is shown that CSF enters the parenchyma between glial and pial basement membranes of penetrating arteries [4]–[6]. Nevertheless, the involved structures and the contribution of either flow pathway to fluid balance between the subarachnoid space and interstitial space remains controversial. Low frequency oscillations in vascular tone are referred to as vasomotion and corresponding vasomotion waves are modeled as the driving force for flow of ISF out of the parenchyma [7]. Retinal vessel analysis (RVA) allows non-invasive measurement of retinal vessel vasomotion with respect to diameter changes [8]. Thus, the aim of the study is to investigate vasomotion in RVA signals of SAH and PHH patients. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 38 EP - 39 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Blaneck, Patrick Gustav A1 - Bornheim, Tobias A1 - Grieger, Niklas A1 - Bialonski, Stephan T1 - Automatic readability assessment of german sentences with transformer ensembles T2 - Proceedings of the GermEval 2022 Workshop on Text Complexity Assessment of German Text N2 - Reliable methods for automatic readability assessment have the potential to impact a variety of fields, ranging from machine translation to self-informed learning. Recently, large language models for the German language (such as GBERT and GPT-2-Wechsel) have become available, allowing to develop Deep Learning based approaches that promise to further improve automatic readability assessment. In this contribution, we studied the ability of ensembles of fine-tuned GBERT and GPT-2-Wechsel models to reliably predict the readability of German sentences. We combined these models with linguistic features and investigated the dependence of prediction performance on ensemble size and composition. Mixed ensembles of GBERT and GPT-2-Wechsel performed better than ensembles of the same size consisting of only GBERT or GPT-2-Wechsel models. Our models were evaluated in the GermEval 2022 Shared Task on Text Complexity Assessment on data of German sentences. On out-of-sample data, our best ensemble achieved a root mean squared error of 0:435. Y1 - 2022 U6 - http://dx.doi.org/10.48550/arXiv.2209.04299 N1 - Proceedings of the 18th Conference on Natural Language Processing/Konferenz zur Verarbeitung natürlicher Sprache (KONVENS 2022) 12-15 September, 2022 University of Potsdam Potsdam, Germany SP - 57 EP - 62 PB - Association for Computational Linguistics CY - Potsdam ER - TY - CHAP A1 - Birgel, Stefan A1 - Leschinger, Tim A1 - Wegmann, Kilian A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Calculation of muscle forces and joint reaction loads in shoulder area via an OpenSim based computer calculation T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 N1 - In der Druckausgabe des Abstractbandes ist dieser Beitrag lose als Erratum beigefügt. SP - 116 EP - 117 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Staat, Manfred ED - Erni, Daniel T1 - Female pelvic floor dysfunction: progress weakening of the support system T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen N2 - The structure of the female pelvic floor (PF) is an inter-related system of bony pelvis,muscles, pelvic organs, fascias, ligaments, and nerves with multiple functions. Mechanically, thepelvic organ support system are of two types: (I) supporting system of the levator ani (LA) muscle,and (II) the suspension system of the endopelvic fascia condensation [1], [2]. Significantdenervation injury to the pelvic musculature, depolimerization of the collagen fibrils of the softvaginal hammock, cervical ring and ligaments during pregnancy and vaginal delivery weakens thenormal functions of the pelvic floor. Pelvic organ prolapse, incontinence, sexual dysfunction aresome of the dysfunctions which increases progressively with age and menopause due toweakened support system according to the Integral theory [3]. An improved 3D finite elementmodel of the female pelvic floor as shown in Fig. 1 is constructed that: (I) considers the realisticsupport of the organs to the pelvic side walls, (II) employs the improvement of our previous FEmodel [4], [5] along with the patient based geometries, (III) incorporates the realistic anatomy andboundary conditions of the endopelvic (pubocervical and rectovaginal) fascia, and (IV) considersvarying stiffness of the endopelvic fascia in the craniocaudal direction [3]. Several computationsare carried out on the presented computational model with healthy and damaged supportingtissues, and comparisons are made to understand the physiopathology of the female PF disorders. Y1 - 2016 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 11 EP - 12 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Staat, Manfred ED - Fernandes, P.R. ED - Tavares, J. M. T1 - Pectopexy to repair vaginal vault prolapse: a finite element approach T2 - Proceedings CMBBE 2018 N2 - The vaginal prolapse after hysterectomy (removal of the uterus) is often associated with the prolapse of the vaginal vault, rectum, bladder, urethra or small bowel. Minimally invasive surgery such as laparoscopic sacrocolpopexy and pectopexy are widely performed for the treatment of the vaginal prolapse with weakly supported vaginal vault after hysterectomy using prosthetic mesh implants to support (or strengthen) lax apical ligaments. Implants of different shape, size and polymers are selected depending on the patient’s anatomy and the surgeon’s preference. In this computational study on pectopexy, DynaMesh®-PRP soft, GYNECARE GYNEMESH® PS Nonabsorbable PROLENE® soft and Ultrapro® are tested in a 3D finite element model of the female pelvic floor. The mesh model is implanted into the extraperitoneal space and sutured to the vaginal stump with a bilateral fixation to the iliopectineal ligament at both sides. Numerical simulations are conducted at rest, after surgery and during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues and prosthetic meshes are modeled as incompressible, isotropic hyperelastic materials. The positions of the organs are calculated with respect to the pubococcygeal line (PCL) for female pelvic floor at rest, after repair and during Valsalva maneuver using the three meshes. Y1 - 2018 N1 - 15th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering and 3rd Conference on Imaging and Visualization. CMBBE 2018. 26-29 March 2018, Lisbon, Portugal ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Biomechanical study of the female pelvic floor dysfunction using the finite element method T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen , Germany, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Staat, Manfred ED - Natal Jorge, Renato T1 - Significance of fibre geometry on passive-active response of pelvic muscles to evaluate pelvic dysfunction T2 - BioMedWomen: Proceedings of the international conference on clinical and bioengineering for women's health Y1 - 2016 SN - 978-1-138-02910-1 SP - 185 EP - 188 PB - CRC Press CY - Boca Raton ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Sora, M.-C. A1 - Staat, Manfred ED - Onate, E. T1 - A 3D finite element model of the female pelvic floor for the reconstruction of urinary incontinence T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20-25, 2014, Barcelona Y1 - 2014 SP - 1 EP - 12 ER - TY - CHAP A1 - Behbahani, Mehdi A1 - Rible, Sebastian A1 - Moulinec, Charles A1 - Fournier, Yvan A1 - Nicolai, Mike A1 - Crosetto, Paolo T1 - Simulation of the FDA Centrifugal Blood Pump Using High Performance Computing T2 - World Academy of Science, Engineering and Technology International Journal of Mechanical and Mechatronics Engineering Y1 - 2015 VL - 9 IS - 5 ER - TY - CHAP A1 - Beging, Stefan A1 - Poghossian, Arshak A1 - Mlynek, D. A1 - Hataihimakul, S. A1 - Pedraza, A. A1 - Dhawan, S. A1 - Laube, N. A1 - Kleinen, L. A1 - Baldsiefen, G. A1 - Busch, H. A1 - Schöning, Michael Josef T1 - Ion-selective sensors for the determination of the risk of urinary stone formation T2 - Micro- and Nanosystems in biochemical diagnosis : Principles and applications Y1 - 2010 SP - 74 EP - 80 CY - Warsaw ER - TY - CHAP A1 - Bayer, Robin A1 - Hescheler, Jürgen A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül ED - Staat, Manfred ED - Erni, Daniel T1 - Treating arterial hypertension in a cell culture well T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH AachenW N2 - Hypertension describes the pathological increase of blood pressure, which is most commonly associated with the increase of vascular wall stiffness [1]. Referring to the “Deutsche Bluthochdruck Liga” this pathology shows a growing trend in our aging society. In order to find novel pharmacological and probably personalized treatments, we want to present a functional approach to study biomechanical properties of a human aortic vascular model. In this method review we will give an overview of recent studies which were carried out with the CellDrum technology [2] and underline the added value to already existing standard procedures known from the field of physiology. Herein described CellDrum technology is a system to measure functional mechanical properties of cell monolayers and thin tissue constructs in-vitro. Additionally, the CellDrum enables to elucidate the mechanical response of cells to pharmacological drugs, toxins and vasoactive agents. Due to its highly flexible polymer support, cells can also be mechanically stimulated by steady and cyclic biaxial stretching. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 5 EP - 6 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Bassam, Rasha A1 - Digel, Ilya A1 - Artmann, Gerhard T1 - Effect of nitric oxide on protein thermal stability : [abstract] N2 - As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not. KW - Stickstoffmonoxid KW - Proteine KW - Hämoglobin KW - nitric oxide gas KW - protein KW - hemoglobin Y1 - 2009 ER - TY - CHAP A1 - Baronas, Romas A1 - Ivanauskas, Feliksas A1 - Kulys, Juozas T1 - Mathematical modeling of biosensors based on an array of enzyme microreactors N2 - This paper presents a two-dimensional-in-space mathematical model of biosensors based on an array of enzyme microreactors immobilised on a single electrode. The modeling system acts under amperometric conditions. The microreactors were modeled by particles and by strips. The model is based on the diffusion equations containing a nonlinear term related to the Michaelis-Menten kinetics of the enzymatic reaction. The model involves three regions: an array of enzyme microreactors where enzyme reaction as well as mass transport by diffusion takes place, a diffusion limiting region where only the diffusion takes place, and a convective region, where the analyte concentration is maintained constant. Using computer simulation, the influence of the geometry of the microreactors and of the diffusion region on the biosensor response was investigated. The digital simulation was carried out using the finite difference technique. KW - Biosensor KW - Reaction-diffusion KW - modeling biosensor KW - microreactor Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1569 ER - TY - CHAP A1 - Barek, Jiri A1 - Fischer, Jan A1 - Navratil, Tomas A1 - Peckova, Karolina A1 - Yosypchuk, Bogdan T1 - Silver solid amalgam electrodes as sensors for chemical carcinogens N2 - The applicability of differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) at a non-toxic meniscus-modified silver solid amalgam electrode (m-AgSAE) for the determination of trace amounts of genotoxic substances was demonstrated on the determination of micromolar and submicromolar concentrations of 3-nitrofluoranthene using methanol - 0.01 mol L-1 NaOH (9:1) mixture as a base electrolyte and of Ostazine Orange using 0.01 mol L-1 NaOH as a base electrolyte. KW - Biosensor KW - Solid amalgam electrodes KW - voltammetry KW - carcinogens KW - 3-nitrofluoranthene KW - Ostazine Orange Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1554 ER - TY - CHAP A1 - Ballmann, J. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - High stress intensities in focussing zones of waves N2 - The propagation of mechanical waves in plates of isotropic elastic material is investigated. After a short introduction to the understanding of focussing of stress waves in a plate with a curved boundary the method of characteristics is applied to a plate of hyperelastic material. Using this method the propagation of acceleration waves is discussed. Based on this a numerical difference scheme is developed for solving initial-boundary-value problems and applied to two examples: propagation of a point disturbance in a homogeneously finitely strained non-linear elastic plate and geometrical focussing in al linear elastic plate. KW - Technische Mechanik KW - Wellen KW - mechanical waves Y1 - 1985 U6 - http://dx.doi.org/10.1016/B978-0-444-42520-1.50015-3 ER - TY - CHAP A1 - Azar, Fouad A1 - Digel, Ilya ED - Staat, Manfred ED - Erni, Daniel T1 - Utilization of fluorescence spectroscopy and neural networks in clinical analysis T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Fluorescence topography of human urine in combination with learning algorithms can provide a variant pattern recognition method in analytical clinical chemistry and, eventually, diagnosis. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 40 EP - 41 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Artmann, Gerhard A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Zaccai, Giuseppe A1 - Büldt, Georg A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - The crucial role of water in a phase transition of hemoglobin at body temperature : [abstract] N2 - The observation of a temperature transition of hemoglobin occurring at a critical temperature close to body temperature KW - Hämoglobin KW - Erythrozyt KW - Körpertemperatur Y1 - 2010 ER - TY - CHAP A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Linder, Peter A1 - Temiz Artmann, Aysegül T1 - Biophysical and Engineering Contributions to Plant Research N2 - Tests with palm tree leaves have just started yet and scan data are in the process to be analyzed. The final goal of future project for palm tree gender and species recognition will be to develop optical scanning technology to be applied to date palm tree leaves for in–situ screening purposes. Depending on the software used and the particular requirements of the users the technology potentially shall be able to identify palm tree diseases, palm tree gender, and species of young date palm trees by scanning leaves. KW - Pflanzenphysiologie KW - Dattel KW - Pflanzenscanner KW - plant scanner KW - date palm tree Y1 - 2011 ER - TY - CHAP A1 - Arinkin, Vladimir A1 - Digel, Ilya T1 - Water bridge phenomenon : [abstract] N2 - One of interesting but not well known water properties is related to appearance of highly ordered structures in response to strong electrical field. In 1893 Sir William Armstrong placed a cotton thread between two wine glasses filled with chemically pure water. When high DC voltage was applied between the glasses, a connection consisting of water formed, producing a "water bridge" KW - Hydrodynamik KW - Elektrodynamik KW - Wasserbrücke KW - water bridge phenomenon Y1 - 2009 ER - TY - CHAP A1 - Arida, Hassan A. A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations N2 - A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors. KW - Biosensor KW - Heavy metal detection KW - thin-film microsensors KW - organic PVC membranes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1545 ER - TY - CHAP A1 - Abel, Thomas A1 - Bonin, Dominik A1 - Albracht, Kirsten A1 - Zeller, Sebastian A1 - Brüggemann, Gert-Peter A1 - Burkett, Brendan A1 - Strüder, Heiko K. T1 - Kinematic profile of the elite handcyclist T2 - 28th International Conference on Biomechanics in Sports, Marquette, Michigan, USA, July 19 – 23, 2010 Y1 - 2017 SN - 1999-4168 SP - 140 EP - 141 ER - TY - CHAP A1 - Abel, Alexander A1 - Pérez-Viana, Daniel A1 - Ciritsis, Bernard A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Prevention of femur neck fractures through femoroplasty T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 114 EP - 115 PB - Universität Duisburg-Essen CY - Duisburg ER -