TY - CHAP A1 - Stollenwerk, Dominik A1 - Rieke, Christian A1 - Dahmen, Markus A1 - Pieper, Martin T1 - Biogas Production Modelling : A Control System Engineering Approach T2 - IOP Conference Series: Earth and Environmental Science. Bd. 32 Y1 - 2016 U6 - https://doi.org/10.1088/1755-1315/32/1/012008 SN - 1755-1315 N1 - ICARET 2016, International Conference on Advances in Renewable Energy and Technologies, Putrajaya, MY, Feb 23-25, 2016 SP - 012008/1 EP - 012008/4 ER - TY - THES A1 - Stollenwerk, Hannah T1 - Rabbit Hole : welchen Einfluss digitale Plattformen auf rechte Radikalisierungsprozesse haben N2 - Obwohl 2019 als das Jahr rechtsterroristischer Anschläge weltweit gilt und die rechte Szene in den letzten Jahren auch in der gesellschaftlichen Mitte deutlich an Zuwachs gewinnen konnte, ist das Thema rund um rechtsextreme Online-Radikalisierung noch verhältnismäßig wenig erforscht. Laut Expert*innen ist dabei jeder Mensch potenziell für eine Radikalisierung anfällig, wenn es die Umstände begünstigen. Dass unsere Leben on- und offline immer weiter miteinander verschmelzen, erhöht die Gefahr für eine mögliche Radikalisierung zusätzlich. »Rabbit Hole« wurde als monothematisch erscheinende Bookazine-Reihe konzipiert, welche pro Ausgabe ein Thema rund um die Gefahren, Herausforderungen und Phänomene, die das Internet und digitale Plattformen mit sich bringen, beleuchtet. Sie soll zur Aufklärung von insbesondere jungen Erwachsenen beitragen. Die erste Ausgabe wurde beispielhaft ausgearbeitet. KW - Editorial Design KW - Typografie KW - Rabbit Hole KW - Bookazine KW - Online-Radikalisierung Y1 - 2023 PB - FH Aachen CY - Aachen ER - TY - CHAP A1 - Stopforth, Riaan A1 - Davrajh, Shaniel A1 - Ferrein, Alexander T1 - South African robotics entity for a collaboration initiative T2 - Pattern Recognition Association of South Africa and Robotics and Mechatronics International Conference (PRASA-RobMech), 2016 Y1 - 2017 SN - 978-1-5090-3335-5 U6 - https://doi.org/10.1109/RoboMech.2016.7813144 N1 - PRASA-RobMech, Nov. 30 2016-Dec. 2 2016, Stellenbosch, South Africa SP - 1 EP - 6 PB - IEEE ER - TY - CHAP A1 - Stopforth, Riaan A1 - Davrajh, Shaniel A1 - Ferrein, Alexander T1 - Design considerations of the duo fugam dual rotor UAV T2 - 2017 Pattern Recognition Association of South Africa and Robotics and Mechatronics (PRASA-RobMech) Y1 - 2017 SN - 978-1-5386-2314-5 U6 - https://doi.org/10.1109/RoboMech.2017.8261115 SP - 7 EP - 13 ER - TY - CHAP A1 - Stopforth, Riaan A1 - Ferrein, Alexander A1 - Steinbauer, Gerald T1 - Europe and South African collaboration on the Mechatronics and Robotics systems as part of the SA Robotics Center T2 - ICRA 2015 Developing Countries Forum N2 - Mechatronics consist of the integration of mechanical engineering, electronic integration and computer science/ engineering. These broad fields are essential for robotic systems, yet it makes it difficult for the researchers to specialize and be experts in all these fields. Collaboration between researchers allow for the integration of experience and specialization, to allow optimized systems. Collaboration between the European countries and South Africa is critical, as each country has different resources available, which the other countries might not have. Applications with the need for approval of any restrictions, can also be obtained easier in some countries compared to others, thus preventing the delays of research. Some problems that have been experienced are discussed, with the Robotics Center of South Africa as a possible solution. Y1 - 2015 ER - TY - CHAP A1 - Stoschek, Oliver A1 - Potthoff, Michael A1 - Petersen, Ole Svenstrup A1 - Larsen, Ole A1 - Engels, Ralf T1 - Ökologische Modellierung von Gewässergüteparametern an der Tide-Elbe N2 - Dr.-Ing. Oliver Stoschek [u.a.] DHI Wasser und Umwelt GmbH, Syke. 14 S. (S. 45-58). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Ökologische Modelle zur Berechnung der Temperaturveränderung und den Einfluss von Kühlwasser auf die Wassertemperatur der Elbe. Die vorgelegte Arbeit wurde beauftragt und unterstützt von der ARGE Elbe im Zuge der Neuauflage des Wärmelastplans Elbe. KW - Wassergüte KW - Wasserwirtschaft KW - Wärmelastplan Y1 - 2009 ER - TY - CHAP A1 - Straube, A1 - Frohn, Jan T1 - Kundennutzen durch logistische Mehrwertleistungen T2 - Handbuch der Kontraktlogistik Y1 - 2007 SN - 9783527502035 SP - 181 EP - 198 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Streese, Lukas A1 - Kotliar, Konstantin A1 - Deiseroth, Arne A1 - Infanger, Denis A1 - Gugleta, Konstantin A1 - Schmaderer, Christoph A1 - Hanssen, Henner T1 - Retinal endothelial function in cardiovascular risk patients: A randomized controlled exercise trial JF - Scandinavian Journal of Medicine and Science in Sports N2 - The aim of this study was to investigate, for the first time, the effects of high-intensity interval training (HIIT) on retinal microvascular endothelial function in cardiovascular (CV) risk patients. In the randomized controlled trial, middle-aged and previously sedentary patients with increased CV risk (aged 58 ± 6 years) with ≥ two CV risk factors were randomized into a 12-week HIIT (n = 33) or control group (CG, n = 36) with standard physical activity recommendations. A blinded examiner measured retinal endothelial function by flicker light-induced maximal arteriolar (ADmax) and venular (VDmax) dilatation as well as the area under the arteriolar (AFarea) and venular (VFarea) flicker curve using a retinal vessel analyzer. Standardized assessments of CV risk factors, cardiorespiratory fitness, and retinal endothelial function were performed before and after HIIT. HIIT reduced body mass index, fat mass, and low-density lipoprotein and increased muscle mass and peak oxygen uptake (VO2peak). Both ADmax (pre: 2.7 ± 2.1%, post: 3.0 ± 2.2%, P = .018) and AFarea (pre: 32.6 ± 28.4%*s, post: 37.7 ± 30.6%*s, P = .016) increased after HIIT compared with CG (ADmax, pre: 3.2 ± 1.8%, post: 2.9 ± 1.8%, P = .254; AFarea, pre: 41.6 ± 28.5%*s, post: 37.8 ± 27.0%*s, P = .186). Venular function remained unchanged after HIIT. There was a significant association between ∆-change VO2peak and ∆-changes ADmax and AFarea (P = .026, R² = 0.073; P = .019, R² = 0.081, respectively). 12-weeks of HIIT improved retinal endothelial function in middle-aged patients with increased CV risk independent of the reduction in classical CV risk factors. Exercise has the potential to reverse or at least postpone progression of small vessel disease in older adults with increased CV risk under standard medication. Dynamic retinal vessel analysis seems to be a sensitive tool to detect treatment effects of exercise interventions on retinal microvascular endothelial function in middle-aged individuals with increased CV risk. Y1 - 2020 U6 - https://doi.org/10.1111/sms.13560 SN - 1600-0838 VL - 30 IS - 2 SP - 272 EP - 280 PB - Wiley CY - Oxford ER - TY - CHAP A1 - Streit, Wilfried T1 - Kalkulation T2 - Zahlentafeln für den Baubetrieb N2 - Das Kapitel behandelt die Kosten- und Preisermittlung, die Kostenvorgabe und Kostenkontrolle. Der Angebotspreis wird aufgeschlüsselt in die Einzelkosten der Teilleistungen, die Baustellengemeinkosten, die Allgemeinen Geschäftskosten und einen Zuschlag für Wagnis und Gewinn. Auf der Basis der Angebotskalkulation werden die Vorgaben für die Kostenkontrolle entwickelt. Y1 - 2016 SN - 978-3-658-02838-1 (Online) SN - 978-3-658-02837-4 (Print) U6 - https://doi.org/10.1007/978-3-658-02838-1_13 SP - 1391 EP - 1501 PB - Springer Vieweg CY - Wiesbaden ET - 9., überarb. und aktual. Aufl. ER - TY - CHAP A1 - Streit, Wilfried T1 - Kalkulation T2 - Übungsaufgaben und Berechnungen für den Baubetrieb Y1 - 2019 SN - 978-3-658-23127-9 U6 - https://doi.org/10.1007/978-3-658-23127-9_11 SP - 273 EP - 334 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Streun, M. A1 - Al-Kaddoum, R. A1 - Parl, C. A1 - Pietrzyk, U. A1 - Ziemons, Karl A1 - Waasen, S. van T1 - Simulation studies of optical photons in monolithic block scintillators T2 - 2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio. Y1 - 2012 SN - 978-1-4673-0120-6 (electronic ISBN) SN - 978-1-4673-0118-3 (print ISBN) U6 - https://doi.org/10.1109/NSSMIC.2011.6154621 SP - 1380 EP - 1382 PB - IEEE CY - New York ER - TY - JOUR A1 - Streun, M. A1 - Beer, S. A1 - Hombach, T. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - PlanTIS: A positron emission tomograph for imaging 11C transport in plants JF - 2007 IEEE Nuclear Science Symposium Conference Record, Vol. 6 N2 - Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary. Y1 - 2008 SN - 1082-3654 SP - 4110 EP - 4112 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 1082-3654 SP - 1636 EP - 1639 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - IEEE Transactions on Nuclear Science N2 - A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 3 SP - 344 EP - 347 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - IEEE Transactions on Nuclear Science N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free-running ADCs at a sampling rate of 40 MHz. A four-channel acquisition board has been developed which is equipped with four 12-bit ADCs connected to one field programmable gate array (FPGA). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware trigger can be omitted. The method of free-running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. This information is crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows very high count rates to be dealt with. Since this method is to be employed in positron emission tomography (PET), the position of an event is also important. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO scintillators coupled to the PS-PMT are presented here Y1 - 2001 SN - 0018-9499 VL - 48 IS - 3 SP - 524 EP - 526 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system with free running ADCs JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 18 EP - 21 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Coincidence detection by digital processing of free-running sampled pulses JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns. Y1 - 2002 SN - 0168-9002 VL - 487 IS - 3 SP - 530 EP - 534 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system based on data processing of free-running sampled pulses JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface. Y1 - 2002 SN - 1082-3654 SP - 693 EP - 694 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - 2000 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free running ADCs at a sampling rate of 40 MHz. A four-channel acquisition-board has been developed which is equipped with four 12 bit-ADCs connected to one FPGA (field programmable gate array). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware-trigger can be omitted. The method of free running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. These informations are crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows coping with very high count rates. Since this method is going to be employed in positron emission tomography (PET), the position of an event is another important information. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO-scintillators coupled to the PS-PMT are presented Y1 - 2000 SN - 1082-3654 SP - 9/179 EP - 9/181 ER - TY - JOUR A1 - Streun, M. A1 - Chavan, U. A1 - Lame, H. A1 - Parl, C. A1 - Müller-Veggian, Mattea A1 - Ziemons, Karl T1 - Treating the Gain Non-Uniformity of Multi Channel PMTs by Channel-Specific Trigger Levels JF - 2006 IEEE Nuclear Science Symposium Conference Record, Vol. 2. Y1 - 2006 SN - 1082-3654 SP - 1301 EP - 1304 CY - San Diego, CA ER - TY - JOUR A1 - Streun, M. A1 - Christ, D. A1 - Hellendung, A. A1 - Larue, H. A1 - Ziemons, Karl A1 - Halling, H. T1 - Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 402 EP - 405 ER - TY - JOUR A1 - Streun, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - A compact PET detector readout using charge-to-time conversion JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics. Y1 - 2009 SN - 1082-3654 SP - 1868 EP - 1870 PB - IEEE CY - New York ER - TY - CHAP A1 - Striebing, Clemens A1 - Müller, Jörg A1 - Schraudner, Martina A1 - Gewinner, Irina Valerie A1 - Guerrero Morales, Patricia A1 - Hochfeld, Katharina A1 - Hoffman, Shekinah A1 - Kmec, Julie A. A1 - Nguyen, Huu Minh A1 - Schneider, Jannick A1 - Sheridan, Jennifer A1 - Steuer-Dankert, Linda A1 - Trimble O'Connor, Lindsey A1 - Vandevelde-Rougale, Agnès T1 - Promoting diversity and combatting discrimination in research organizations: a practitioner’s guide T2 - Diversity and discrimination in research organizations N2 - The essay is addressed to practitioners in research management and from academic leadership. It describes which measures can contribute to creating an inclusive climate for research teams and preventing and effectively dealing with discrimination. The practical recommendations consider the policy and organizational levels, as well as the individual perspective of research managers. Following a series of basic recommendations, six lessons learned are formulated, derived from the contributions to the edited collection on “Diversity and Discrimination in Research Organizations.” KW - Inclusive work climate KW - lessons learned KW - policy recommendations KW - recommendations for actions KW - bullying Y1 - 2022 SN - 978-1-80117-959-1 (Print) SN - 978-1-80117-956-0 (Online) U6 - https://doi.org/10.1108/978-1-80117-956-020221012 SP - 421 EP - 442 PB - Emerald Publishing Limited CY - Bingley ER - TY - CHAP A1 - Striegan, C. A1 - Haj Ayed, A. A1 - Funke, Harald A1 - Loechle, S. A1 - Kazari, M. A1 - Horikawa, A. A1 - Okada, K. A1 - Koga, K. T1 - Numerical combustion and heat transfer simulations and validation for a hydrogen fueled "micromix" test combustor in industrial gas turbine applications T2 - Proceedings of the ASME Turbo Expo Y1 - 2017 SN - 978-079185085-5 U6 - https://doi.org/10.1115/GT2017-64719 N1 - ASME Turbo Expo 2017: Turbomachinery Technical Conference and Exposition, GT 2017; Charlotte; United States; 26 June 2017 through 30 June 2017 IS - Volume Part F130041-4B, 2017 ER - TY - CHAP A1 - Striegan, Constantin J. D. A1 - Struth, Benjamin A1 - Dickhoff, Jens A1 - Kusterer, Karsten A1 - Funke, Harald A1 - Bohn, Dieter T1 - Numerical Simulations of the Micromix DLN Hydrogen Combustion Technology with LES and Comparison to Results of RANS and Experimental Data T2 - Proceedings of International Gas Turbine Congress 2019 Tokyo, November 17-22, 2019, Tokyo, Japan. Y1 - 2019 SN - 978-4-89111-010-9 N1 - IGCT-2019-147 SP - 1 EP - 9 ER - TY - CHAP A1 - Stroetmann, Richard A1 - Lohse, Wolfram T1 - Stahlbau T2 - Wendehorst Beispiele aus der Baupraxis. - 4. Aufl. Y1 - 2012 SN - 978-3-8348-0999-5 ; 978-3-8348-8229-5 U6 - https://doi.org/10.1007/978-3-8348-8229-5_10 SP - 263 EP - 361 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Stroetmann, Richard A1 - Lohse, Wolfram ED - Vismann, Ulrich T1 - Stahlbau T2 - Wendehorst bautechnische Zahlentafeln / 35. Auflage N2 - Es ist zwischen Stählen bis S460 und solchen mit höherer Streckgrenze zu unterscheiden. Stähle bis S460 sind auch für die plastische Tragwerksberechnung nach dem Fließgelenkverfahren zugelassen. Bei Stählen oberhalb S460 bis S700 ist neben der elastischen eine nichtlineare plastische Tragwerksberechnung unter Berücksichtigung von Teilplastizierungen von Bauteilen in Fließzonen möglich. Y1 - 2015 SN - 978-3-658-01689-0 ; 978-3-410-24199-7 U6 - https://doi.org/10.1007/978-3-658-01689-0_13 SP - 657 EP - 859 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Stroetmann, Richard A1 - Lohse, Wolfram T1 - Stahlbau T2 - Wendehorst Beispiele aus der Baupraxis. / 5. Auflage Y1 - 2015 SN - 978-3-658-01689-0 ; 978-3-410-24199-7 U6 - https://doi.org/10.1007/978-3-658-01681-4_10 SP - 323 EP - 431 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Strohmeier, Andreas T1 - Wasserwirtschaft JF - Bautechnische Zahlentafeln : [jetzt mit neuer DIN 1052, DIN1053-1 und DIN 1054] / Wendehorst. Hrsg. von Otto W. Wetzell. Bearb. von: Herwig Baumgartner .... 31., vollst. überb. und aktualisierte Aufl. Y1 - 2004 SN - 3-410-13944-4 N1 - Abschnitt 15 SP - 1119 EP - 1258 PB - Teubner [u.a.] CY - Stuttgart [u.a.] ER - TY - JOUR A1 - Strohmeier, Andreas T1 - Neue Kläranlage Rostock - kombinierter Einsatz von Belebungs- und Aufstromfiltrationsverfahren JF - Wasser und Boden. 48 (1996), H. 8 Y1 - 1996 SN - 0043-0951 SP - 47 EP - 49 ER - TY - JOUR A1 - Strohmeier, Andreas T1 - Wasserrechtliche Notwendigkeit der weitergehenden Abwasserreinigung JF - Forum Städte-Hygiene. 33 (1982), H. 6 Y1 - 1982 SN - 0342-202X SP - 309 EP - 311 ER - TY - BOOK A1 - Strohmeier, Andreas T1 - Untersuchungsbericht zu einem neuartigen Verfahren über die Phosphat- Elimination in Simultanteichen unter Einsatz von Eisen-, Aluminiumsalzen und Kalziumionen Y1 - 1980 CY - Mölln ER - TY - BOOK A1 - Strohmeier, Andreas T1 - Eliminationsverhalten und Beeinflussung von ausgewählten umweltrelevanten biologisch schwer abbaubaren Kohlenwasserstoffverbindungen in verschiedenen Belebtschlammanlagen Y1 - 1985 N1 - Aachen, Techn. Hochsch., Diss., 1985 ER - TY - JOUR A1 - Strohmeier, Andreas T1 - Kläranlage Rostock : Optimierung der Abwasserreinigung durch den kombinierten Einsatz von Belebungs- und Aufstromfiltrationsverfahren ; erste Erfahrungen. JF - Österreichische Wasser- und Abfallwirtschaft : ÖWAW ; Zeitschrift für alle wissenschaftlichen, technischen, rechtlichen und wirtschaftlichen Fragen des gesamten Wasser- und Abfallwesens. 48 (1996), H. 7-8 Y1 - 1996 SN - 0945-358X SP - 232 EP - 236 ER - TY - JOUR A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft JF - Bautechnische Zahlentafeln / Wendehorst, Reinhard ; Wetzell, Otto W. [Hrsg.] 32., vollst. aktualisierte Aufl. Y1 - 2007 SN - 978-3-8351-0055-8 SP - 1193 EP - 1289 PB - Teubner CY - Stuttgart ER - TY - CHAP A1 - Strohmeier, Andreas ED - Vismann, Ulrich T1 - Siedlungswasserwirtschaft T2 - Wendehorst Bautechnische Zahlentafeln Y1 - 2012 SN - 978-3-8348-0960-5 U6 - https://doi.org/10.1007/978-3-8348-8613-2_19 N1 - Kapitel 19 SP - 1393 EP - 1498 PB - Vieweg + Teubner CY - Wiesbaden ET - 34 ER - TY - JOUR A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft JF - Wendehorst Beispiele aus der Baupraxis / Wetzell, Otto W. ; Baumgartner, Herwig ; Wendehorst, Reinhard [Hrsg.]. Y1 - 2007 SN - 978-3-8351-0069-5 N1 - Kapitel 14 SP - 395 EP - 431 PB - Teubner CY - Wiesbaden ER - TY - CHAP A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft T2 - Wendehorst bautechnische Zahlentafeln / hrsg. von Ulrich Vismann. Ernst Biener ... 35. Aufl. Y1 - 2015 SN - 978-3-658-01688-3 SP - 1157 EP - 1230 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft T2 - Wendehorst Beispiele aus der Baupraxis. - 4. Aufl. Y1 - 2012 SN - 978-3-8348-0999-5 ; 978-3-8348-8229-5 U6 - https://doi.org/10.1007/978-3-8348-8229-5_16 SP - 527 EP - 566 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft T2 - Wendehorst Beispiele aus der Baupraxis. - 3. Aufl. Y1 - 2009 SN - 978-3-8348-0684-0 ; 978-3-8348-9997-2 U6 - https://doi.org/10.1007/978-3-8348-9997-2_15 SP - 423 EP - 462 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Strohmeier, Andreas T1 - Wasserwirtschaft T2 - Wendehorst Beispiele aus der Baupraxis. - 1. Aufl. Y1 - 2005 SN - 3-519-00489-5 ; 978-3-519-00489-9 SP - 221 EP - 254 PB - Teubner CY - Stuttgart ER - TY - CHAP A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft T2 - Wendehorst Beispiele aus der Baupraxis. / 5. Auflage N2 - Nachfolgende Ausführungen und Berechnungsbeispiele beziehen sich auf Kapitel 19 Siedlungswasserwirtschaft im „Wendehorst: Bautechnische Zahlentafeln 35. Auflage 2015“ (abgekürzt: BZ). Für den Bau von Anlagen der Siedlungswasserwirtschaft sind ebenso die Grundlagen der Hydraulik zu berücksichtigen. Aus diesem Grunde sind auch die entsprechenden Ausführungen zur Hydraulik zu beachten. Y1 - 2015 SN - 978-3-658-01689-0 ; 978-3-410-24199-7 U6 - https://doi.org/10.1007/978-3-658-01681-4_16 SP - 635 EP - 678 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Strohmeier, Andreas A1 - Eichholz, Günter T1 - Elimination von Phosphaten in technisch belüfteten Abwasserteichen / Eichholz, Günter; Strohmeier, Andreas JF - Wasser und Boden. 33 (1981), H. 5 Y1 - 1981 SN - 0043-0951 SP - 230 EP - 239 ER - TY - BOOK A1 - Stulpe, Werner T1 - Bedingte Erwartungen und stochastische Prozesse in der generalisierten Wahrscheinlichkeitstheorie : Beschreibung sukzessiver Messungen mit zufälligem Ausgang Y1 - 1986 N1 - Berlin, Techn. Univ., Diss. CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - From the attempt of certain classical reformulations of quantum mechanics to quasi-probability representations JF - Journal of mathematical physics N2 - The concept of an injective affine embedding of the quantum states into a set of classical states, i.e., into the set of the probability measures on some measurable space, as well as its relation to statistically complete observables is revisited, and its limitation in view of a classical reformulation of the statistical scheme of quantum mechanics is discussed. In particular, on the basis of a theorem concerning a non-denseness property of a set of coexistent effects, it is shown that an injective classical embedding of the quantum states cannot be supplemented by an at least approximate classical description of the quantum mechanical effects. As an alternative approach, the concept of quasi-probability representations of quantum mechanics is considered. Y1 - 2013 U6 - https://doi.org/10.1063/1.4861939 SN - 1089-7658 (Online) SN - 0022-2488 (Print) VL - 55 IS - 1 PB - American Institute of Physics ER - TY - BOOK A1 - Stulpe, Werner T1 - Classical Representations of Quantum Mechanics Related to Statistically Complete Observables Y1 - 1997 SN - 3-89685-438-0 N1 - Zugl. Berlin, Techn. Univ., Habil.-Schr. 1997 PB - Wissenschaft und Technik Verl. CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - Pairwise coexistence of effects versus coexistence JF - Journal of Physics: Conference Series Y1 - 2020 U6 - https://doi.org/10.1088/1742-6596/1638/1/012004 SN - 1742-6596 VL - 1638 IS - 012004 SP - 1 EP - 21 PB - IOP CY - Bristol ER -