TY - BOOK A1 - Uibel, Thomas A1 - Peterson, Leif Arne ED - Uibel, Thomas ED - Peterson, Leif Arne T1 - Tagungsband Aachener Holzbautagung 2017 Y1 - 2017 SN - 2197-4489 PB - FH Aachen CY - Aachen ER - TY - BOOK A1 - Uibel, Thomas A1 - Peterson, Leif Arne ED - Uibel, Thomas ED - Peterson, Leif Arne T1 - Tagungsband Aachener Holzbautagung 2015 Y1 - 2015 SN - 2197-4489 PB - FH Aachen CY - Aachen ER - TY - JOUR A1 - Laumann, Jörg A1 - Mainz, Stefan A1 - Krahwinkel, Manuel T1 - Traglastuntersuchungen an Koppelpfetten bei Biegung um die schwache Achse und Torsion JF - Stahlbau Y1 - 2017 U6 - https://doi.org/10.1002/stab.201710544 SN - 0038-9145 VL - 86 IS - 11 SP - 1005 EP - 1016 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Valero, Daniel A1 - Viti, Nicolo A1 - Gualtieri, Carlo T1 - Numerical Simulation of Hydraulic Jumps. Part 1: Experimental Data for Modelling Performance Assessment JF - Water Y1 - 2019 U6 - https://doi.org/10.3390/w11010036 SN - 2073-4441 VL - 11 IS - 1 SP - Art. Nr. 36 PB - MDPI CY - Basel ER - TY - JOUR A1 - Viti, Nicolo A1 - Valero, Daniel A1 - Gualtieri, Carlo T1 - Numerical Simulation of Hydraulic Jumps. Part 2: Recent Results and Future Outlook JF - Water Y1 - 2019 U6 - https://doi.org/10.3390/w11010028 SN - 2073-4441 VL - 11 IS - 1 SP - Art. Nr. 28 ER - TY - JOUR A1 - Richter, L. A1 - Wichern, M. A1 - Grömping, Markus A1 - Robecke, U. A1 - Haberkamp, J. T1 - Ammonium recovery from process water of digested sludge dewatering by membrane contactors JF - Water Practice and Technology N2 - Membrane contactors are a promising alternative for nitrogen removal and recovery from process water compared to other physicochemical and biological sidestream treatment processes. Münster wastewater treatment plant (WWTP) is the first municipal WWTP in Germany operating a full-scale membrane contactor system to improve the nitrogen elimination and recovery efficiency. Factors influencing the operation and membrane performance are investigated in an accompanying research project. Additional operational aspects of the applied membrane modules are investigated in detail using a bench-scale membrane contactor. First results of the full-scale application demonstrate a high nitrogen removal efficiency of >95%. Y1 - 2020 U6 - https://doi.org/10.2166/wpt.2020.002 SN - 1751-231X VL - 15 IS - 1 SP - 84 EP - 91 PB - IWA Publishing CY - London ER - TY - JOUR A1 - Kerres, Karsten A1 - Gredigk-Hoffmann, Sylvia A1 - Jathe, Rüdiger A1 - Orlik, Stefan A1 - Sariyildiz, Mustafa A1 - Schmidt, Torsten A1 - Sympher, Klaus-Jochen A1 - Uhlenbroch, Adrian T1 - Future approaches for sewer system condition assessment JF - Water Practice & Technology N2 - Different analytical approaches exist to describe the structural substance or wear reserve of sewer systems. The aim is to convert engineering assessments of often complex defect patterns into computational algorithms and determine a substance class for a sewer section or manhole. This analytically determined information is essential for strategic rehabilitation planning processes up to network level, as it corresponds to the most appropriate rehabilitation type and can thus provide decision-making support. Current calculation methods differ clearly from each other in parts, so that substance classes determined by the different approaches are only partially comparable with each other. The objective of the German R&D cooperation project ‘SubKanS’ is to develop a methodology for classifying the specific defect patterns resulting from the interaction of all the individual defects, and their severities and locations. The methodology takes into account the structural substance of sewer sections and manholes, based on real data and theoretical considerations analogous to the condition classification of individual defects. The result is a catalogue of defect patterns and characteristics, as well as associated structural substance classifications of sewer systems (substance classes). The methodology for sewer system substance classification is developed so that the classification of individual defects can be transferred into a substance class of the sewer section or manhole, eventually taking into account further information (e.g. pipe material, nominal diameter, etc.). The result is a validated methodology for automated sewer system substance classification. Y1 - 2020 U6 - https://doi.org/10.2166/wpt.2020.027 SN - 1751-231X IS - 15 (2) SP - 386 EP - 393 PB - IWA Publishing CY - London ER - TY - JOUR A1 - Hahn, Geogr W. A1 - Hebel, Christoph A1 - Manz, W. T1 - Die neuen Empfehlungen für Verkehrsnachfragemodellierung im Personenverkehr JF - Straßenverkehrstechnik N2 - Die neu erschienenen „Empfehlungen zum Einsatz von Verkehrsnachfragemodellen für den Personenverkehr“ liefern erstmals als Empfehlungspapier der Forschungsgesellschaft für Straßen- und Verkehrswesen einen umfassenden Überblick zu den verschiedenen Aspekten der Modellierung und geben dem Fachplaner konkrete Hilfestellung für die Konzeption von Nachfragemodellen. Das Empfehlungspapier zielt unter anderem darauf ab, die Erwartungen und das Anspruchsniveau in Hinblick auf Sachgerechtigkeit der Modelle, die erzielbare Modellqualität und den Detaillierungsgrad der Modellaussagen zu harmonisieren. Y1 - 2022 U6 - https://doi.org/10.53184/SVT10-2022-1 SN - 0039-2219 VL - 66 IS - 10 SP - 721 EP - 726 PB - Kirschbaum Verlag GmbH CY - Bonn ER - TY - JOUR A1 - Emig, J. A1 - Hebel, Christoph A1 - Schwark, A. T1 - Einsatzbereiche für Verkehrsnachfragemodelle JF - Straßenverkehrstechnik N2 - In der Praxis bestehen vielfältige Einsatzbereiche für Verkehrsnachfragemodelle. Mit ihnen können Kenngrößen des Verkehrsangebots und der Verkehrsnachfrage für den heutigen Zustand wie auch für zukünftige Zustände bereitgestellt werden, um so die Grundlagen für verkehrsplanerische Entscheidungen zu liefern. Die neuen „Empfehlungen zum Einsatz von Verkehrsnachfragemodellen für den Personenverkehr“ (EVNM-PV) (FGSV 2022) veranschaulichen anhand von typischen Planungsaufgaben, welche differenzierten Anforderungen daraus für die Modellkonzeption und -erstellung resultieren. Vor dem Hintergrund der konkreten Aufgabenstellung sowie deren spezifischer planerischer Anforderungen bildet die abzuleitende Modellspezifikation die verabredete Grundlage zwischen Auftraggeber und Modellersteller für die konkrete inhaltliche, fachliche Ausgestaltung des Verkehrsmodells. Y1 - 2022 U6 - https://doi.org/10.53184/SVT10-2022-2 SN - 0039-2219 VL - 66 IS - 10 SP - 727 EP - 736 PB - Kirschbaum Verlag GmbH CY - Bonn ER - TY - JOUR A1 - Kindmann, Rolf A1 - Kraus, Matthias A1 - Laumann, Jörg A1 - Vette, Jan T1 - Verallgemeinerte Berechnungsmethode für in Beton eingespannte Stahlprofile – Einspanntiefen, Tragfähigkeitsnachweise und Bemessungshilfen JF - Stahlbau N2 - Stützen und Träger aus Stahlprofilen können in Fundamente oder Wände aus Stahlbeton einbetoniert werden. Diese Anschlüsse wirken in der Regel wie Einspannungen, die eine ausreichende Einspanntiefe erfordern. Im Folgenden wird eine verallgemeinerte Berechnungsmethode für in Stahlbetonkonstruktionen eingespannte Stahlprofile aus gewalzten I-Profilen, geschweißten I-Profilen, runden Hohlprofilen, eckigen Hohlprofilen und einzelligen Kastenquerschnitten vorgestellt. Für Beanspruchungen infolge einachsiger Biegung um die starke und schwache Profilachse werden der profilabhängige Ansatz der Betondruckspannungen im Einspannbereich und die Ermittlung der Einspanntiefe behandelt. Unter Berücksichtigung der Normalkraft werden an den maßgebenden Stellen Tragfähigkeitsnachweise für die Stahlprofile geführt. Als Ergänzung zu den Berechnungsformeln werden Bemessungshilfen zur Verfügung gestellt, die die Wahl der mitwirkenden Breiten und der Einspanntiefen erleichtert. KW - Stahlprofile KW - Anschlüsse an Stahlbeton KW - Einspanntiefen KW - Eingespannte Stützen und Träger KW - steel profiles Y1 - 2022 U6 - https://doi.org/10.1002/stab.202200024 SN - 1437-1049 VL - 93 IS - Early View SP - 1 EP - 25 PB - Ernst & Sohn GmbH CY - Berlin ER - TY - BOOK A1 - Laumann, Jörg A1 - Feldmann, Markus A1 - Frickel, Jörg A1 - Krahwinkel, Manuel A1 - Kraus, Matthias A1 - Stranghöner, Natalie A1 - Ummenhofer, Thomas T1 - Petersen Stahlbau : Grundlagen der Berechnung und baulichen Ausbildung von Stahlbauten N2 - Die Theorie und Konstruktion der wichtigsten Bereiche der Stahlbautechnik werden von den Grundlagen her entwickelt und durch viele Beispiele praxisbezogen erläutert. Das Buch ist aus Vorlesungen im Grund- und Vertiefungsstudium des Bauingenieurwesens entstanden. Der Inhalt wird zum Teil systematisch, zum Teil exemplarisch dargestellt. Für Konstrukteure und Statiker in den technischen Büros, der Beratenden Ingenieure und der Prüfämter enthält das Buch aufbereitete Berechnungsverfahren und Konstruktionsvorschläge in großer Zahl. KW - Behälterbau KW - Bemessung KW - Brandschutz KW - Brückenbau KW - Festigkeitslehre Y1 - 2022 SN - 978-3-658-20510-2 U6 - https://doi.org/10.1007/978-3-658-20510-2 PB - Springer Vieweg CY - Wiesbaden ET - 5. Auflage ER - TY - RPRT A1 - Geißler, Karsten A1 - Prokop, Ines A1 - Bubner, André A1 - Egner, Ralf A1 - Heyde, Stefan A1 - Kempkes, Marian A1 - Kühn, Bertram A1 - Laumann, Jörg A1 - Lieberwirth, Peter A1 - Naumes, Johannes A1 - Ruga, Julija A1 - Schilling, Sivo A1 - Schmidt, Herbert A1 - Ummenhofer, Thomas T1 - Verbesserung der Praxistauglichkeit der Baunormen durch pränormative Arbeit – Teilantrag 3: Stahlbau, Abschlussbericht Y1 - 2015 SN - 978-3-8167-9539-1 PB - Fraunhofer IRB Verlag CY - Stuttgart ER - TY - JOUR A1 - Hörenbaum, Christoph A1 - Laumann, Jörg A1 - Prokop, Ines T1 - Zur Anwendung des Eurocode 3 Teil 1-2 für die Heißbemessung und Anregungen für dessen Novellierung JF - Stahlbau N2 - Die Eurocodes werden bis zum Jahr 2020 im Europäischen Komitee für Normung (CEN), Technisches Komitee TC 250, überarbeitet. In Vorbereitung auf die Eurocode-Novellierung haben engagierte Ingenieure im Rahmen der Initiative PraxisRegeln Bau (PRB) die für die praktische Anwendung häufig genutzten Teile des Eurocode 3 untersucht. Mit dem Ziel, die Praxistauglichkeit des Eurocode 3 für die Heißbemessung zu verbessern, wurden die bestehende Norm EN 1993 Teil 1-2 insbesondere in Bezug auf die Anwenderfreundlichkeit analysiert und Vorschläge für die europäische Novellierung erarbeitet. Die Analysen zeigen, dass durch Umstrukturierungen und durch die Einführung von Tabellen die Verständlichkeit und Anwenderfreundlichkeit der Regeln für die Heißbemessung bedeutend erhöht werden können. KW - EN 1993-1-2 KW - Tragwerksbemessung KW - Brandfall KW - Forschung, pränormativ KW - structural design Y1 - 2016 U6 - https://doi.org/10.1002/stab.201610382 SN - 1437-1049 VL - 85 IS - 6 SP - 429 EP - 434 PB - Ernst & Sohn GmbH CY - Berlin ER - TY - JOUR A1 - Höttges, Jörg T1 - QKan - Management of drainage system data with QGIS JF - Free and Open Source Software for Geospatial (FOSS4G) Conference Proceedings Y1 - 2017 VL - 17 IS - Article 13 SP - 95 EP - 100 ER - TY - CHAP A1 - Sparla, Peter T1 - Vermessung T2 - Übungsaufgaben und Berechnungen für den Baubetrieb Y1 - 2019 SN - 978-3-658-23127-9 U6 - https://doi.org/10.1007/978-3-658-23127-9_2 SP - 13 EP - 61 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Ulke, Bernd T1 - Der baurechtliche Vertrag T2 - Übungsaufgaben und Berechnungen für den Baubetrieb N2 - Anhand von kurzen theoretischen Einführungen werden anhand von Beispielen die wesentlichen Aspekte des baurechtlichen Vertrages erläutert. Nach einer Einführung über das Zustandekommen von (Bau-) Verträgen wird die für Streitfälle unerlässliche Dokumentation auf Baustellen erläutert. Hierbei werden Hinweise zur Erstellung von Protokollen, zum E-Mail bei Großprojekten und zur Dokumentation von Stundenlohnarbeiten gegeben. Des Weiteren wird eine Schriftverkehrsliste vorgestellt, die zur Nachverfolgung des Schriftverkehrs bei Großprojekten unerlässlich ist. Anschließend werden die typischen Vertragsarten vorgestellt, die bei der Abwicklung von Großprojekten zu beachten sind und die Unterschiede werden durch Fallbeispiele erläutert. Einen Schwerpunkt des Kapitels bilden auftragsnehmerseitige Verzüge sowie mangelbehaftete Leistungen. Hier werden Hinweise gegeben, wie in den entsprechenden Situationen zu reagieren ist. Y1 - 2019 SN - 978-3-658-23127-9 SP - 63 EP - 87 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Ulke, Bernd T1 - Baukosten und Finanzierung T2 - Übungsaufgaben und Berechnungen für den Baubetrieb Y1 - 2019 SN - 978-3-658-23127-9 U6 - https://doi.org/10.1007/978-3-658-23127-9_4 SP - 89 EP - 100 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Ulke, Bernd T1 - Arbeitsvorbereitung und Ablaufplanung T2 - Übungsaufgaben und Berechnungen für den Baubetrieb Y1 - 2019 SN - 978-3-658-23127-9 U6 - https://doi.org/10.1007/978-3-658-23127-9_6 SP - 117 EP - 154 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Ulke, Bernd T1 - Boden, Baugrube, Verbau T2 - Übungsaufgaben und Berechnungen für den Baubetrieb N2 - Im folgenden Kapitel werden die wichtigsten geotechnischen Nachweise sowie praxisnahe Beispiele für den Baubetrieb aufgeführt. Es wird im Wesentlichen auf die Bodenbeschreibung und Klassifikation nach DIN 18196 sowie nach DIN 18300 eingegangen, welche sowohl für die weiteren Berechnungen als auch für die Kalkulation von großer Bedeutung sind. Die aus der Praxis aufgeführten Beispiele verdeutlichen verschiedene Untersuchungs- und Auswertungsmethoden für direkte und indirekte Aufschlüsse, diese enthalten Labor- und Feldversuche, mit denen man die Verdichtbarkeit von Böden auswertet und quantifiziert, sowie viele andere Themenbereiche wie Erddruckberechnungen sowie Spannungs- und Setzungsberechnungen. Darüber hinaus werden exemplarisch bestimmte Verbauarten bezüglich ihrer Bemessung erläutert. Es wird ebenfalls auf das Thema Wasserhaltung eingegangen und die erforderlichen Maßnahmen beschrieben, um bestimmte Versagensmechanismen - wie z.B. den hydraulischen Grundbruch - zu verhindern. Y1 - 2019 SN - 978-3-658-23127-9 (Online) SN - 978-3-658-23126-2 (Print) U6 - https://doi.org/10.1007/978-3-658-23127-9_8 SP - 165 EP - 239 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Lemke, Jörg T1 - Arbeitssicherheit T2 - Übungsaufgaben und Berechnungen für den Baubetrieb Y1 - 2019 SN - 978-3-658-23127-9 U6 - https://doi.org/10.1007/978-3-658-23127-9_12 SP - 335 EP - 344 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Duffner, Markus A1 - Moorkamp, Wilfried A1 - Peterson, Leif Arne A1 - Uibel, Thomas ED - Kuhlmann, Ulrike T1 - Untersuchungen zur Tragfähigkeit und Steifigkeit eines neuartigen Wandelements in Holzbauweisen T2 - Doktorandenkolloquium Holzbau Forschung + Praxis : Stuttgart, 08./09. März 2018 Y1 - 2018 SP - 131 EP - 139 PB - Universität Stuttgart, Institut für Konstruktion und Entwurf CY - Stuttgart ER - TY - JOUR A1 - Gronsfeld, Richard A1 - Joachim, Klubert A1 - Malecha, Hartmut T1 - 3-D-Visualisierung von vorhandenen Staubauwerken zur holistischen Planung und Überwachung JF - Wasserwirtschaft Y1 - 2019 U6 - https://doi.org/10.1007/s35147-019-0075-x SN - 2192-8762 N1 - gedruckt in der Bereichsbibliothek Bayernallee unter der Signatur 13 Z 218 vorhanden VL - 109 IS - 5 SP - 82 EP - 85 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kuhnhenne, Markus A1 - Reger, Vitali A1 - Pyschny, Dominik A1 - Döring, Bernd T1 - Influence of airtightness of steel sandwich panel joints on heat losses JF - E3S Web of Conferences 12th Nordic Symposium on Building Physics (NSB 2020) N2 - Energy saving ordinances requires that buildings must be designed in such a way that the heat transfer surface including the joints is permanently air impermeable. The prefabricated roof and wall panels in lightweight steel constructions are airtight in the area of the steel covering layers. The sealing of the panel joints contributes to fulfil the comprehensive requirements for an airtight building envelope. To improve the airtightness of steel sandwich panels, additional sealing tapes can be installed in the panel joint. The influence of these sealing tapes was evaluated by measurements carried out by the RWTH Aachen University - Sustainable Metal Building Envelopes. Different installation situations were evaluated by carrying out airtightness tests for different joint distances. In addition, the influence on the heat transfer coefficient was also evaluated using the Finite Element Method (FEM). The combination of obtained air volume flow and transmission losses enables to create an "effective heat transfer coefficient" due to transmission and infiltration. This summarizes both effects in one value and is particularly helpful for approximate calculations on energy efficiency. Y1 - 2020 U6 - https://doi.org/10.1051/e3sconf/202017205008 VL - 172 IS - Art. 05008 PB - EDP Sciences CY - Les Ulis ER - TY - CHAP A1 - Uibel, Thomas A1 - Moorkamp, Wilfried T1 - Geh- und Radwegbrücken in NRW - Bestandsanalyse und Perspektiven T2 - Holzbrückenbau in der Offensive : Erhaltung, Ertüchtigung, Neubauten : 5. Internationale Holzbrückentage (IHB 2018) FILharmonie Filderstadt, Filderstadt/Stuttgart (DE), 17./18. April 2018 Y1 - 2018 SN - 978-3-906226-19-4 SP - 19 EP - 32 PB - forum-holzbau CY - Biel ER - TY - CHAP A1 - Jockwer, R. A1 - Kleiber, M. A1 - Uibel, Thomas ED - Görlacher, Rainer T1 - Criteria for Evaluating the Simplification of Design Rules for Dowel-type Fasteners T2 - International Network on Timber Engineering Research, INTER : proceedings, meeting 51, 10 - 13 August 2016, Tallinn, Estonia Y1 - 2018 SP - 461 EP - 466 PB - Timber Scientific Publishing, KIT Holzbau und Baukonstruktionen CY - Karlsruhe ER - TY - CHAP A1 - Bedbur, Christian A1 - Thull, J. A1 - Moorkamp, Wilfried A1 - Uibel, Thomas T1 - Standardbrücken für Geh- und Radwege T2 - Tagungsband 4. Aachener Holzbautagung 2019: 12. und 13. September an der FH Aachen Y1 - 2020 SN - 2197-4489 SP - 34 EP - 45 PB - FH Aachen CY - Aachen ER - TY - JOUR A1 - Reger, V. A1 - Döring, Bernd A1 - Kuhnhenne, M. T1 - Passive und aktive Maßnahmen zur Flächenkühlung im Stahl(leicht)bau JF - Bauingenieur N2 - Mit steigenden Dämmstandards und höheren Komfortanforderungen der Nutzer gerät die Problematik der sommerlichen Überhitzung zunehmend in den Fokus. Um die Überhitzung möglichst gering zu halten, sind Maßnahmen und Lösungen zu entwickeln, die den potenziellen Kühlbedarf eines Gebäudes vermeiden sowie reduzieren. Im Rahmen des europäischen Forschungsprojektes BATIMASS wurden Techniken untersucht, die die sommerliche Raumtemperatur ohne zusätzliche Kühlung (passiv) oder aber mit energieeffizienter wasserbasierter Flächenkühlung (aktiv) reduzieren und die besonders für Gebäude in Stahl(leicht)bauweise geeignet sind. Dafür wurde die Methodik der thermisch äquivalenten Decke weiterentwickelt, um das thermische Verhalten von Profilblechdecken in Gebäuden für beide Lösungsansätze analysieren zu können. Darüber hinaus wurde der Einsatz von Phasenwechselmaterial (PCM) zur Steigerung der Speicherfähigkeit von leichten Decken mit besonders geringer thermischer Masse in Simulationen sowie im Labor untersucht und bewertet. Y1 - 2016 U6 - https://doi.org/10.37544/0005-6650-2016-07-08-63 SN - 0005-6650 N1 - gedruckt in der Bereichsbibliothek Bayernallee unter der Signatur 13 Z 049 VL - 91 IS - Jul/Aug SP - 309 EP - 316 PB - VDI Fachmedien CY - Düsseldorf ER - TY - RPRT A1 - Sansom, M. A1 - Lawson, R.M. A1 - Tucho, R. A1 - Kendrick, C. A1 - Ogden, R. A1 - Resalati, S. A1 - Garay, R. A1 - Döring, Bernd A1 - Reger, V. A1 - Gilbert, J. A1 - Heikkinen, J. A1 - Hemmila, K. T1 - Building in active thermal mass into steel structures (BATIMASS) - EUR 28166EN N2 - The main objective of the BATIMASS project was to address how the energy balance in relatively lightweight steel buildings can be improved by building in ‘active thermal mass’ (ATM) into the building fabric. This was achieved through concept design, dynamic thermal modelling and testing of a number of potentially viable systems and concepts. A significant programme of thermal simulation modelling was undertaken utilising the thermally equivalent slab (TES) concept to model the passive thermal capacity effect of profiled, composite metal floor decks. It is apparent from the modelling results that thermal mass is a highly complex phenomenon which is highly dependent upon building type, occupancy patterns, climate and many other aspects of the building design and servicing strategy. The ATM systems developed, both conceptually and for prototype testing, focussed on water-cooled composite slabs, the Cofradal floor system and the phase change material (PCM) Energain. In addition to laboratory testing of prototypes, whole building monitoring was undertaken at the Kubik building in Spain and the RWTH test building in Germany. Advanced thermal modelling was also undertaken to estimate the likely benefits of the ATM concept designs developed and for comparison with the test results. In addition to thermal testing, structural tests were conducted on composite floor specimens incorporating embedded water pipes. This Final Report presents the results of the activities carried out under this RFCS contract RFSR CT 2012 00033. The work carried out is reported in six major sections corresponding to the technical Work Packages of the project. Only summaries of the work carried out are provided in this report; all work undertaken is fully reported in the formal project deliverables. KW - industrial research KW - iron and steel industry KW - research project KW - materials technology KW - resistance of materials KW - steel KW - metal structure KW - ingot KW - building industry KW - research report Y1 - 2016 SN - 978-92-79-63176-4 U6 - https://doi.org/10.2777/25999 SN - 1831-9424 PB - Publications Office of the European Union CY - Luxembourg ER - TY - RPRT A1 - Lawson, R.M. A1 - Baddoo, N.R. A1 - Vanier, G. A1 - Döring, Bernd A1 - Kuhnhenne, M. A1 - Nieminen, J. A1 - Beguin, P. A1 - Herbin, S. A1 - Caroli, G. A1 - Adetunji, I. A1 - Kozlowski, A. T1 - Renovation of buildings using steel technologies (Robust) - EUR 25335 N2 - Robust addresses the renovation and improvement of existing residential, industrial and commercial buildings using steel-based technologies, focusing on techniques such as over-cladding, over-roofing and roof-top extensions. Steel-intensive renovation techniques currently on the market were reviewed. Performance criteria were developed for over-cladding systems meeting current regulatory standards, with guidelines on how to achieve appropriate levels of air-tightness. KW - iron and steel industry KW - steel KW - materials technology KW - building materials KW - metal structure KW - building safety KW - testing KW - industrial research Y1 - 2013 SN - 978-92-79-24950-1 U6 - https://doi.org/10.2777/97860 SN - 1831-9424 PB - Publications Office of the European Union CY - Luxembourg ER - TY - RPRT A1 - Feldmann, M. A1 - Kuhnhenne, M. A1 - Döring, Bernd A1 - Pyschny, D. A1 - Lawson, R.M. A1 - Chuter, R.D. A1 - Boudjabeur, S. A1 - Lecomte-Labory, F. A1 - Airaksinen, M. A1 - Heikkinen, J. A1 - Laamanen, J. A1 - Albart, P. A1 - D'Haeyer, R. A1 - Chica, J.A. A1 - Maseda, J.M. A1 - Amundarain, A. A1 - Rips, M.O. A1 - Nuñez, J.A. A1 - Macías, O. A1 - Beguin, P. A1 - Ben Larbi, A. T1 - Energy and thermal improvements for construction in steel (ETHICS) - EUR 26010 N2 - ETHICS is concerned with evaluating, measuring and making improvements in the thermal and energy performance of steel-clad and steel-framed buildings. It addresses basic building physics performance at a laboratory and full-scale level, and the preparation of design guidance for commercial, industrial and residential buildings. It includes the development of design tools to assist users in assessing whole-building performance, and calibrates these tools against whole-building measurements, which will be obtained from this research. Opportunities for renewable energy and other energy-saving features will be assessed. This project focuses on objectives that are of particular interest for the design of new steel constructions regarding energy efficiency. ETHICS investigates the as-built performance by on-site tests regarding air tightness and heat transfer properties of the building envelope and by monitoring the energy consumption and thermal comfort of selected up-to-date steel buildings. As energy efficiency is a key requirement for design and construction of buildings in the future, this project provides well-founded scientific data, which prove the high energy performance of current steel constructions and work out details for further improvements to maintain and extend the position of steel products in the construction sector. KW - steel KW - metal structure KW - building technique KW - energy efficiency KW - thermal insulation KW - industrial research KW - research report Y1 - 2013 SN - 978-92-79-30789-8 U6 - https://doi.org/10.2777/17106 SN - 1831-9424 PB - Publications Office of the European Union CY - Luxembourg ER - TY - RPRT A1 - Kesti, Jyrki A1 - Mononen, Tarmo A1 - Lautso, Petteri A1 - Döring, Bernd A1 - Reger, Vitali A1 - Holopainen, R. A1 - Jung, N. A1 - Shemeikka, J. A1 - Nieminen, J. A1 - Reda, F. A1 - Lawson, Mark A1 - Botti, Andrea A1 - Hall, R. A1 - Zold, A. A1 - Buday, T. T1 - Zero energy solutions for multifunctional steel intensive commercial buildings (ZEMUSIC) - EUR 27627 N2 - The broad commercial objective of this project was the sustainable value creation in steel building technology by addressing the ways in which significant energy reductions can be made in the operation phase of multi-storey commercial buildings. A review on energy efficient commercial buildings in Europe has been carried out consisting of several case studies from different countries. The project included development of zero-energy concepts for reducing energy demand as well as concepts for heating, cooling and ventilation systems by utilising renewable energy sources in three different climates. Also alternative structural frame solutions were developed and analyzed in respect of structural and MEP (mechanical, electrical and plumbing solutions) features. An innovative long span floor system with integrated MEP routings promises a cost effective alternative for sophisticated ventilation distribution and radiant heating and cooling systems, allowing for high energy efficiency and high quality interior climate. The report includes also review of best architectural practices for integrated renewable energy solutions including different design strategies for building facades of zero energy buildings. Interesting results and design basis are also presented for steel energy pile concept, where structural foundation piles are utilized for ground energy harvesting. Life cycle cost calculations for near zero energy office building based on developed technologies show that a near zero energy construction is also profitable. The results and work methods of the project have been summarized in the form of design guidance that offers designers the knowledge gained in a form that can be easily understood. KW - steel KW - iron and steel industry KW - resistance of materials KW - materials technology KW - metal structure KW - research project KW - building industry KW - building materials KW - renewable energy KW - designs and models KW - research report KW - guide Y1 - 2015 SN - 978-92-79-54071-4 U6 - https://doi.org/10.2777/111520 SN - 1831-9424 N1 - Enthalten: Appendix Design Guide: Deliverable Report WP6.4 Design Guide for steel intensive nearly zero office buildings (83 Seiten) PB - Publications Office of the European Union CY - Luxembourg ER - TY - JOUR A1 - Pyschny, D. A1 - Döring, Bernd A1 - Feldmann, M. T1 - Ermittlung der thermischen Leistungsfähigkeit des neuartigen multifunktionalen Verbunddeckensystems InaDeck JF - Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen Y1 - 2014 SN - 0005-6650 N1 - Printausgabe in der Bibliothek Bayernallee vorhanden: 13 Z 049-2014 VL - 89 IS - 3 SP - 116 EP - 124 PB - VDI Fachmedien CY - Düsseldorf ER - TY - CHAP A1 - Feldmann, M. A1 - Döring, Bernd A1 - Pyschny, D. T1 - Floor systems; Sustainabilty analyses and assessments of steel bridges T2 - Sustainable steel buildings : a practical guide for structures and envelopes Y1 - 2016 SN - 978-1-118-74079-8 (PDF) SN - 978-1-118-74111-5 SP - 198 EP - 223 PB - Wiley Blackwell CY - Chichester, West Sussex ER - TY - JOUR A1 - Hennes, Philipp A1 - Laumann, Jörg T1 - Ansatz der Drehbehinderung aus Koppelpfetten mit dünnwandigen kaltgeformten Z-Profilen JF - Stahlbau Y1 - 2021 U6 - https://doi.org/10.1002/stab.202000104 SN - 1437-1049 VL - 90 IS - 3 SP - 158 EP - 168 PB - Ernst & Sohn CY - Berlin ER - TY - RPRT A1 - Kluge, Katharina A1 - Kirsch, Ansgar A1 - Budach, Christoph T1 - Digitale Lehre in der Geotechnik: Aktueller Stand und weitere Entwicklungen T2 - geotechntik N2 - Digitale Lehrmaterialien werden seit mehreren Jahren in den Hochschulen eingesetzt und eröffnen ganz neue Wege zur Vermittlung des Lehrstoffs. Die Erstellung dieser Lehrmaterialien kann allerdings je nach Art und Qualität sehr zeitintensiv sein und für Lehrende einen großen Mehraufwand bedeuten. Im Rahmen eines Kooperationsprojekts zur Erstellung von Lehrvideos für geotechnische Feld- und Laborversuche haben die Autoren dieses Beitrags allerdings die Erfahrung gemacht, dass das gemeinsame, hochschulübergreifende Erstellen von Lehrmaterialien viele Vorteile mit sich bringt. Dadurch inspiriert, führten die Autoren dieses Berichts eine Umfrage unter den deutschsprachigen Geotechnik-Lehrstühlen der (Technischen) Universitäten und (Fach-)Hochschulen durch. Nach drei Semestern, in denen Lehrveranstaltungen an den Hochschulen aufgrund der Corona-Pandemie überwiegend digital durchgeführt werden mussten, war es ein Ziel dieser Umfrage, den Bestand und den Einsatz digitaler Lehrmaterialien im Fachgebiet Geotechnik zu erheben. Ein weiteres Ziel war die Initiierung eines Netzwerks, in dem sich Geotechnik-Professorinnen und -Professoren zu Lehrthemen austauschen können und gemeinsam (digitale) Lehrmaterialien erstellen und nutzen. Der vorliegende Beitrag stellt das gemeinsame Lehrprojekt der Autoren vor, präsentiert die Ergebnisse der durchgeführten Umfrage und berichtet über die ersten Aktivitäten des neuen Netzwerks. KW - digitale Lehre KW - Geotechnik KW - digital teaching KW - geotechnical engineering KW - Didaktik Y1 - 2022 U6 - https://doi.org/10.1002/gete.202200013 SN - 0172-6145 (Print) SN - 2190-6653 (Online) IS - Early View PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Timmer, H. T1 - Energetische und betriebswirtschaftliche Bewertung von Kühlsystemen für Kühllager JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 1998 SN - 1436-5103 VL - 49 IS - 9 SP - 74 EP - 77 PB - Springer CY - Düsseldorf ER - TY - CHAP A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz A1 - Renz, Ulrich ED - Jamal, Rahman ED - Jaschinski, Hans T1 - Messwerterfassung und –auswertung mit LabView: Experimentelle Analyse der Mischungsgüte in Hybridzellenkühltürmen T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000 N2 - Zur Kühlung von Abwärmeströmen aus Kraftwerksprozessen werden in zunehmenden Maße Hybridzellenkühltürme mit Zwangskonvektion eingesetzt, deren wesentlicher Vorteil ihre geringe Bauhöhe ist. Um bei derartigen Kühltürmen eine Sichtbehinderung oder Glatteisgefährdung durch bodennahen Nebel zu vermeiden, muss durch eine optimale Vermischung des Trocken- und Naßluftanteils gewährleistet sein, daß aus der Kühlturmkrone keine Nebelschwaden austreten. In Zusammenarbeit mit der Industrie betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen einen Versuchsstand zur Erfassung der Mischungsgüte in Hybridzellenkühltürmen. In maßstabsgerechter Nachbildung können dabei am Modell alle relevanten Einflußgrößen wie Kühlturmgeometrie, Gestaltung zusätzlicher Mischeinbauten sowie die Betriebsparameter variiert werden. Mit Hilfe einer unter LabView 5.01 erstellten Software werden sowohl die l3etriebszustüncle online überwacht, als auch die benötigten Meßwerte zur Bestimmung der Mischungsgüte erfaßt. Über die grafische Oberfläche können sämtliche Meßoptionen gesteuert sowie alle Meßdaten visualisiert und kontrolliert werden. In das LabView-Programm sind darüber hinaus Routinen zur Auswertung der Daten implementiert worden, die sowohl eine direkte Darstellung der Ergebnisse in Form von Diagrammen ermöglichen, als auch zur Weiterverarbeitung einen Datenexport in eine Microsoft- Excel-Tabelle vorsehen. N2 - The Institute of Heat Transfer and Air Conditioning at the Aachen University of Technology operates in co-operation with industrial partners a test facility in order to investigate mixture quality in hybrid cooling towers. In a scaled mock-up a variation of all relevant data such as the geometry of the cooling tower, the design of additional mixers and the operation parameters could be realized. A software tool, created with LabView 5.01, offers the possibility to control the whole process and to measure all relevant quantities. The graphic user interface permits an online control and a visualization of the measured values. Beyond this the program is not only able to evaluate the data and to represent the results in form of diagrams, but also to export the data directly into an Microsoft-Excel-sheet for further analysing. Y1 - 2000 SN - 3-7785-2789-4 (print) SP - 54 EP - 60 PB - Hüthig CY - Heidelberg ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Thulfaut, Christian A1 - Renz, Ulrich ED - Jamal, Rahman ED - Jaschinski, Hans T1 - On-Line Simulation mit LabView: Experimentelle und numerische Analyse homogener Gasphasenreaktionen aus Kraftwerksprozessen, T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000 N2 - The institute of heat transfer and air conditioning at the Aachen University of Technology operates several test facilities in order to investigate homogeneous and catalytical processes for the reduction of gaseous pollutants (e.g. nitrous oxide) of flue gases in a tempeature range up to 900°C. One test facility consists of a stainless steel reactor in which the influence of reducing additives can be investigated. The software tool, created with LabVIEW 5.01, offers the possibility to measure, visualize and control all relevant physical quantities and to gain a numerical solution of the problem by solving the one dimensional, steady state conservation equations. N2 - Die bei Kohlekraftwerksprozessen entstehenden Rauchgase enthalten einen nicht unerheblichen Teil an Schadgaskomponenten (z.B. Stickoxide), die aus dem Gasstrom entfernt werden müssen. Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Prüfstände für Untersuchungen auf dem Gebiet der homogenen und heterogen-katalytischen Schadstoffreduktion heißer Rauchgase bei Temperaturen bis zu 900 °C. Für die Erforschung der Minderungspotentiale geeigneter, auf Distickstoffoxid reduzierend wirkender Additive, wie Wasserstoffperoxid, oder auch Katalysatoren, befindet sich ein Reaktor in Betrieb, der eine Untersuchung der Reaktionskinetik bei der Entfernung von Schadgaskomponenten aus einem lnertgasstrom ermöglicht. Wesentlich für den Erfolg der Forschungsarbeit ist eine auf das spezielle Projekt genau abgestimmte Meß- und Regelungstechnik. Neben der Auswahl geeigneter Hardwarekomponenten ist auch die Softwareentwicklung unter einer leistungsstarken und zuverlässigen Programmierumgebung von großer Bedeutung. Hierbei dient die unter LabVIEW 5.01 entwickelte Datenerfassung- und Auswertesoftware zum einen der Messung, Visualisierung und Regelung der relevanten Temperaturen, Drücke, Konzentrationen und Volumenströme einzelner Gaskomponenten. Zum anderen ermöglicht sie parallel eine numerische Simulation der Vorgänge innerhalb des Reaktors zur Anpassung reaktionskinetischer Parameter aus den sich ergebenden Versuchsdaten durch Lösung eindimensionaler, stationärer Erhaltungsgleichungen. Y1 - 2000 SN - 3-7785-2789-4 (print) SP - 103 EP - 108 PB - Hüthig CY - Heidelberg ER - TY - RPRT A1 - Christ, Ansgar A1 - Groß, Rolf Fritz A1 - Renz, Ulrich T1 - Strömungs-, Filterkuchen- und Abreinigungsmodelle für Heißgasfilter, Teilvorhaben "Numerische Simulation des Abreinigungsvorganges und der Rohgasströmung" KW - Prozesssimulation KW - Filterkuchen KW - Druckvergasung KW - Druckwirbelschichtfeuerung KW - Rauchgasreinigung Y1 - 1998 U6 - https://doi.org/10.2314/GBV:50431601X N1 - Verbundprojekt im Rahmen der Projektträgerschaft BEO des BMBF der Partner RWTH Aachen, Lehrstuhl für Wärmeübertragung und Klimatechnik Brandenburgische Technische Universität Cottbus, Lehrstuhl Regelungstechnik Universität Karlsruhe, Institut für Mechanische Verfahrenstechnik und Mechanik LLB Lurgi Lentjes Babcock Energietechnik GmbH, Oberhausen Förderkennzeichen: 0326831B Abschlußbericht ER - TY - CHAP A1 - Dautzenberg, H. A1 - Groß, Rolf Fritz A1 - Renz, Ulrich ED - Jamal, Rahman T1 - Meßtechnik auf dem Prüfstand: Forschung zur Heißgasfiltration T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 1996 N2 - Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Prüfstände für Untersuchungen auf dem Gebiet der Heißgasfiltration mit keramischen Filterelementen. Als wesentlicher Garant für den Erfolg der Forschungsarbeit muß die auf das jeweilige Projekt genau abgestimmte Meß- und Regelungstechnik angesehen werden. Hierbei zählt neben der Auswahl geeigneter Hardwarekomponenten auch die Softwareentwicklung unter einer leistungsstarken und zuverlässigen Programmierumgebung. Anhand des Aufbaus dreier Versuchsanlagen im Technikumsmaßstab soll das Anforderungsprofil an die Meßtechnik bis hin zur Umsetzung innerhalb der Anlage skizziert werden. Der Heißgasfiltrationsprüfstand im Heizkraftwerk der RWTH Aachen dient der Beobachtung des Reinigungsverhaltens keramischer Filterelemente bei der Heißgasentstaubung im Temperaturbereich bis 850 Grad C. Wesentlich für die Meßwerterfassung ist hierbei die Kopplung eines Orion-Datenloggers der Firma Schlumberger mit LabView 4.0. Im Hochtemperaturofen des Lehrstuhls werden instationäre Druckmessungen an einer keramischen Filterkerze während eines Abreinigungsimpulses bei 950 Grad C mit hoher Samplingrate durchgeführt. Hierbei übernimmt eine durch LabView 4.0 angesteuerte E-Series Karte der Firma National Instruments die Signalaufnahme. Die katalytische Schadstoffreduktion und Entstaubung heißer Rauchgase bei 900 Grad C sind Ziele der Untersuchungen in einer erstellten Versuchsanlage mit einem Quarzglasreaktor. Die Signalerfassung und -konditionierung erfolgt über SCXI in Verbindung mit LabView 4.0, die Steuerung der Anlage übernehmen zwei Multifunktionskarten (National Instruments). KW - keramischer Werkstoff KW - Filter (Stofftrennung) KW - Filtration KW - Entstaubung KW - Staubfilter Y1 - 1996 N1 - 5.-6. November 1996 Forum der Technik München, Germany SP - 202 EP - 208 PB - National Instruments Germany CY - München ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Müller, D. A1 - Herting, D. A1 - Schneemann, A. A1 - Renz, Ulrich ED - Rahman, Jamal ED - Jaschinski, Hans T1 - Modulare Messdatenerfassung in Forschung und Lehre T2 - Virtuelle Instrumente in der Praxis : Begleitband zum Kongress VIP '97 N2 - The Lehrstuhl für Wärmeübertragung und Klimatechnik at the Aachen University of Technology operates several test facilities to investigate fundamentals of heat and mass transfer supported by the Deutsche Forschungsgemeinschaft, the Minister für Forschung und Technologie and the industry. In order to get high-resolution and reproselection of hardware components is as critical as the design of software routines to perform successful and accurate measurements. In the following the development of the measurement and control system for three different test facilities is presented and discussed. Special attention is given to the education of students within the framework of laboratories and scientific experiments. Y1 - 1997 SN - 978-3-7785-2667-5 Pp. SP - 282 EP - 288 PB - Hüthig CY - Heidelberg ER - TY - RPRT A1 - Ayar, A. A1 - Fielenbach, C. A1 - Groß, Rolf Fritz A1 - Holfeld, T. A1 - Lockemann, S. A1 - Severin, C. A1 - Thulfaut, Christian A1 - Hillemacher, B. T1 - Druckkohlenstaubverbrennung von rheinischer Braunkohle : Abschlussbericht T1 - Pressure combustion of rhenish brown coal : final report N2 - Im Rahmen des Forschungsschwerpunkts 3 wurde experimentell und theoretisch die NO{sub x}-Bildung und -Reduktion bei der Druckkohlenstaubverbrennung untersucht. Der zuvor beschriebene Einfluss der Kohlemahlung auf die Flamme konnte auch anhand der NO{sub x}-Messungen an der DKSF-Anlage Aachen bestaetigt werden. Waehrend mit Braunkohle im Staubfeuerungsbetrieb noch keine eindeutige Druckabhaengigkeit nachgewiesen werden konnte, haben vom Lehrstuhl durchgefuehrte NO{sub x}-Messungen an der DKSF-Anlage Dorsten im Schmelzkammerfeuerungsbetrieb mit der Steinkohle Spitzbergen zwischen 9 und 13 bar ein Absinken der Stickoxidkonzentrationen mit steigendem Druck ergeben. Fuer die rheinische Braunkohle soll dieser Druckeinfluss in den naechsten Versuchsfahrten ausfuehrlicher untersucht werden. Es wurde anhand von numerischen Simulationen zu einer Braunkohleflamme der 6. Versuchsfahrt ein Vergleich zwischen der NO{sub x}-Modellierung im Standard-FLUENT-Code und in dem mit User Defined Subroutines der international flame research foundation (IFRF), Ijmuiden, erweiterten FLUENT-Code vorgenommen. Es zeigte sich, dass bei der Modellierung der Stickoxidbildung die unterschiedlich vorhergesagten Flammentemperaturen eine entscheidende Rolle spielen. Eine genauere Analyse der NO{sub x}-Modelle im Vergleich zu Messergebnissen ist bei einer Schmelzkammerfeuerung mit einer stabilen Flamme vorzunehmen. Es wurden zusaetzlich Messungen zur Untersuchung der Kinetik homogener Gasphasenreaktionen in Rauchgasen an einem Stahlreaktor durchgefuehrt. Dabei wurde sowohl der thermisch bedingte als auch der durch zudosierte Additive katalysierte Abbau nitroser Komponenten betrachtet. Vergleichend wurden mit einem am Lehrstuhl entwickelten Programm die Kinetik beschrieben. Hierbei wird mit einer Sensitivitaetsanalyse eine Reduzierung der detaillierten Darstellung der Reaktionskinetik erreicht, die es erlaubt, mit einem CFD-Code wie FLUENT zwei- und dreidimensionale Rechnungen zum Abbau verschiedener Rauchgaskomponenten durchzufuehren. Die Uebereinstimmung zwischen ein- und zweidimensionalen Rechnungen und den Messungen ist gut. N2 - NOx formation and reduction in the coal combustion process was investigated both experimentally and theoretically. The influence of coal grain size described in earlier publications was proved by the measurements at the DKSF test facility at Aachen. While no pressure dependence was established so far for lignite, measurements on Spitzbergen coal at 9 - 13 bar showed a decrease in NOx concentrations with increasing pressure. This effect will be investigated for Rhenish brown coal in further experiments. Modelling by the standard FLUENT code and by the user defined subroutines of the FLUENT code developed by the International Flame Research Foundation (IFRF), Ijmuiden, showed that the different predictions of flame temperatures have a decisive role in the modelling of NOx formation. A more accurate analysis of the NOx models as compared to ther measurements will be carried out in a melting chamber furnace with a stable flame. Additionally, measurements were carried out for investigating the kinetics of homogeneous gaseous phase reactions in flue gases, i.e. the thermal and additive-catalysed degradation of nitrous components was investigated. The kinetics of the process was also described by a code developed at Aachen University. On the base of a sensitivity analysis, a reduction of the detailed modelling of the reaction kinetics is achieved which permits 2D and 3D calculations on the decomposition of different flue gas components using a CFD code like FLUENT. The 1D and 2D calculations and the measurements were found to be in good agreement. Y1 - 2003 N1 - Druckkohlenstaubverbrennung von rheinischer Braunkohle Förderkennzeichen: 0327072 Abschlussbericht zum Forschungsvorhaben ausführende Stelle: Lehrstuhl fur Wärmeübertragung und Klimatechnik der RWTH Aachen Professor Dr.-Ing. U. Renz ER - TY - JOUR A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz T1 - Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenkühltürmen JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Zwangsbelüftete Nasskühltürme haben im Gegensatz zur Trockenkühlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßkühlung die spezifische Kühlleistung durch abgeführte Kondensationswärme höher als bei der Trockenkühlung. Hybridzellenkühltürme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftströme die Wasserdampf-Sättigungsgrenze nicht überschreitet. Durch das Mischungsverhältnis kann man den gewünschten Sättigungsgrad einstellen. Je dichter dieser an der Sättigungsgrenze liegt, desto höher ist die Kühlleistung. Der von unten zugeführte Luftstrom der Naßkühlung und der seitlich zugeführte trockene Abluftstrom müssen sehr gut durchmischt werden, um über den gesamten Austrittsquerschnitt des Kühlturms die Sättigungsgrenze nicht zu überschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. Über ein Raster von 10 mal 10 Punkten wurde die örtliche Temperaturverteilung ermittelt. Wärmebilanzen ergeben dann die Mischungsgüte in einer Ebene oberhalb der Zellenkrone. Während ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 % liegt erhöhen Einbauten den Trockenluftanteil auf 30 % bis über 40 %. Dabei wurde die Trockenluft auf jeder Kühlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftauslässe umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gewünschten Mittelwert zeigen Potential für die weitere Verbesserung der Einbauten. KW - Trockenkühlturm KW - Nasskühlturm KW - kombiniertes Verfahren KW - Mischen KW - Abluft Y1 - 2000 SN - 1436-5103 VL - 51 IS - 8 SP - 48 EP - 49 PB - Springer CY - Düsseldorf ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Hecken, M. A1 - Renz, Ulrich ED - Dittler, A. ED - Hemmer, G. ED - Kasper, G. T1 - Hot gas filtration with ceramic filter candles: experimental and numerical investigations on fluid flow during element cleaning T2 - High temperature gas cleaning. Vol. 2 N2 - Ceramic hot gas filters are widely used in combined cycles based on pressurised fluidised beds. They fulfil most of the demands with respect to cleaning efficiency and long time durability, but their operation regarding the consumption of pulse gas and energy still has to be optimised. Experimental investigations were carried out to measure the flow field, the pressure and the gas temperature inside the filter candle during pulse jet cleaning. These results are compared with the results of a numerical procedure based on a solution of the two - dimensional conservation equations for momentum and energy. The observed difficulties handling different flow regimes like highly turbulent flow as well as Darcy flow simultaneously are discussed. KW - 20 fossil-fueled power plants KW - hot gas cleanup KW - ceramics KW - filtration KW - gas flow Y1 - 1999 SN - 3-9805220-1-6 N1 - 4th International Symposium and Exhibition on Gas Cleaning at High Temperatures, 22.-24.09.1999, Karlsruhe SP - 862 EP - 873 PB - KIT Institut für Mechanische Verfahrenstechnik und Mechanik CY - Karlsruhe ER - TY - CHAP A1 - Groß, Rolf Fritz T1 - Möglichkeiten und Grenzen für Forschung an Fachhochschulen T2 - Smart Building Convention und BIMconvention in Aachen im September Y1 - 2018 N1 - 10. und 11. September 2018, Aachen ER - TY - RPRT A1 - Höfler, Matthias A1 - Groß, Rolf Fritz T1 - Optimierung der Oxidationskinetik von Sulfit zu Sulfat durch effiziente feinblasige Belüftung bei Anlagen zur Rauchgasentschwefelung fossil befeuerter Kraftwerke und Industrieanlagen mittels Seewasser ("Optiox") N2 - Das Forschungsvorhaben Optiox beschäftigt sich mit der Optimierung eines Belüftungsbeckens zur Rauchgasentschwefelung fossil befeuerter Kraftwerke mittels Seewasser. Unter Neutralisierung der entstehenden Hydroniumionen (H3O+) durch die natürliche Alkalität des Seewassers dissoziiert Schwefeldioxid aus dem Rauchgase im vorgeschalteten Absorber beim Phasenübergang von der Gas- in die Flüssigphase zu Sulfiten. Im Belüftungsbecken werden diese Sulfite mittels eingeblasener Luft zu Sulfaten oxidiert, was zu einer geringen Erhöhung der Sulfatfracht vor Einleitung ins Meer führt, die unterhalb der natürlichen Schwankungen liegt. Daneben dient das Belüftungsbecken der Konditionierung des Seewassers hinsichtlich pH-Wert und Sauerstoffgehalt und ist mit hoch effizienten Belüftern ausgestattet, deren Spezifikation den jeweiligen Randbedingungen, wie Abscheideleistung des Absorbers, Beckengeometrie sowie lokalen Gegebenheiten angepasst wird. Y1 - 2016 N1 - Projektlaufzeit: 10/2012 – 09/2015 Gefördert durch: BMBF – Förderkennlinie Ingenieurnachwuchs Kooperationspartner: Doosan Lentjes GmbH, Ratingen, FH Aachen, Fachbereich Energietechnik, Prof. Dr.-Ing. Rolf Groß ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. T1 - Quo Vadis - Ausblick in die Gebäudeleittechnik der Zukunft T1 - Whitherfacility management? An outlook to the future JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerstände bei der Durchdringung des Marktes. N2 - Producers and planners of facility management systems are still faced with building owners' reluctance, especially when it comes to private homes. Y1 - 2005 SN - 1436-5103 VL - 56 IS - 1 SP - 39 EP - 41 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. A1 - Groß, H. T1 - Gebäudeautomation - Betriebsdatenerfassung und Gebäudeleittechnik im Klartext T1 - Operating data- and facility management in clear JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 2003 SN - 1436-5103 VL - 54 IS - 2 SP - 81 PB - Springer CY - Düsseldorf ER - TY - THES A1 - Groß, Rolf Fritz T1 - Zur Kinetik homogener Gasphasenreaktionen nitroser Komponenten in Rauchgasen einer kohlebefeuerten Wirbelschicht KW - Kohlefeuerung KW - Wirbelschichtfeuerung KW - Stickstoffoxide KW - Reduktion KW - Rohrreaktor Y1 - 2002 SN - 3-8322-0004-5 (softcover) SN - 3-8322-0004-6 (elektronisch) N1 - Dissertation RWTH Aachen PB - Shaker CY - Aachen ER - TY - RPRT A1 - Christ, Ansgar A1 - Groß, Rolf Fritz A1 - Renz, Ulrich T1 - HGR: Untersuchung zur Minimierung von gasförmigen Schadstoffen aus Rauchgasen bei der Heißgasfiltration T1 - Hot gas filtration: investigations to remove gaseous pollutant components out of flue gas during hot gas filtration N2 - Gas- und Dampfturbinen-Kraftwerke mit Druckwirbelschicht- oder mit Druckvergasungsverfahren ermöglichen die Verstromung von Kohle mit hohem Wirkungsgrad und niedrigen Emissionen. Eine Voraussetzung für den Betrieb dieser Anlagen ist die Entstaubung der Rauchgase bei hohen Temperaturen und Drücken. Abreinigungsfilter mit keramischen Elementen werden dazu eingesetzt. Eine Reduzierung gasförmiger Schadstoffe unter den gleichen Bedingungen könnte Rauchgaswäsche ersetzen. Ziel des Gesamtvorhabens ist es, die Integration von Heißgasfiltration und katalytischem Abbau der Schadstoffe Kohlenmonoxid, Kohlenwasserstoffe und Stickoxide in einen Verfahrensschritt zu untersuchen. Die Arbeitsschwerpunkte dieses Teilvorhabens betreffen: die katalytische Wirkung eisenhaltiger Braunkohlenaschen, die Wirksamkeit des Calciumaluminat als Katalysator des Abbaus unverbrannter Kohlenwasserstoffe im Heißgasfilter, numerische Simulation der kombinierten Abscheidung von Partikeln und gasförmigen Schadstoffen aus Rauchgasen N2 - Power plants with gas and steam turbines in pressurized fluidized bed or pressurized gasification processes enable power generation of coal with high efficiancy and little emissions. To run these plants the cleaning of the flue gas is necessary before entering the turbines under the conditions of high temperature and pressure. Ceramic filter elements are the most probable method for hot gas cleaning. A simultaneous reduction of gaseous pollutant components under these conditions could help to make the whole process more efficiant. The aim of the project is to integrate the catalytic reduction of carbon monoxide, hydrocarbons and nitric oxides into the hot gas filtration with ceramic filter elements as a one step mecanism. The project is focused on: the catalytic behaviour of ferrugious ashes of brown coal, the effectiveness of calcinated aluminates as a catalyst to remove uncombuste hydrocarbons in a hot gas filtration unit, numerical simulation of the combined removal of particels and gaseous pollutant components out of the flue gas. KW - Kraftwerkstechnik KW - Stickstoffoxide KW - Kohlenmonoxidbelastung KW - Schadgas KW - Heterogene Katalyse Y1 - 1998 U6 - https://doi.org/10.2314/GBV:504318411 N1 - Verbundprojekt im Rahmen der Projektträgerschaft BEO des BMBF der Partner RWTH Aachen, Lehrstuhl für Wärmeübertragung und Klimatechnik uve Institut für Technische Chemie und Umweltschutz GmbH, Berlin-Adlershof Hugo Petersen, Gesellschaft für verfahrenstechnischen Anlagenbau mbH&Co.KG, Wiesbaden Förderkennzeichen: 0326819F [Abschlußdatum des Vorhabens: Dezember 1997] ER -