TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER - TY - JOUR A1 - Christ, D. A1 - Hollendung, A. A1 - Larue, H. A1 - Parl, C. A1 - Streun, M. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. T1 - Homogenization of the MultiChannel PM gain by inserting light attenuating masks JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2. Y1 - 2004 SN - 1082-3654 SP - 2382 EP - 2385 ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Auffray, E. A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Streun, M. A1 - Christ, D. A1 - Hellendung, A. A1 - Larue, H. A1 - Ziemons, Karl A1 - Halling, H. T1 - Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 402 EP - 405 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Beer, S. A1 - Streun, M. A1 - Hombach, T. A1 - Buehler, J. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants JF - Physics in Medicine and Biology N2 - Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements. Y1 - 2010 U6 - https://doi.org/10.1088/0031-9155/55/3/006 SN - 1361-6560 VL - 55 IS - 3 SP - 635 EP - 646 PB - IOP CY - Bristol ER - TY - JOUR A1 - Herzog, Hans A1 - Pietrzyk, Uwe A1 - Shah, N. Jon A1 - Ziemons, Karl T1 - The current state, challenges and perspectives of MR-PET JF - Neuroimage N2 - Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop. Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.10.036 SN - 1053-8119 VL - 49 IS - 3 SP - 2072 EP - 2082 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER - TY - CHAP A1 - Streun, M. A1 - Al-Kaddoum, R. A1 - Parl, C. A1 - Pietrzyk, U. A1 - Ziemons, Karl A1 - Waasen, S. van T1 - Simulation studies of optical photons in monolithic block scintillators T2 - 2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio. Y1 - 2012 SN - 978-1-4673-0120-6 (electronic ISBN) SN - 978-1-4673-0118-3 (print ISBN) U6 - https://doi.org/10.1109/NSSMIC.2011.6154621 SP - 1380 EP - 1382 PB - IEEE CY - New York ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Suso, Henri-Pierre A1 - Rysstad, Gunnar A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes JF - Physica status solidi (a) N2 - A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests. KW - calorimetric gas sensor;hydrogen peroxide;wireless sensor system Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200920 SN - 1862-6319 VL - 210 IS - 5 SP - 877 EP - 883 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - CHAP A1 - Gerhards, Michael A1 - Sander, Volker A1 - Belloum, Adam T1 - Seamlessly enabling the use of cloud resources in workflows T2 - Cloud Computing 2013 : The Fourth International Conference on Cloud Computing, GRIDs, and Virtualization : May 27 - June 1, 2013 - Valencia, Spain Y1 - 2013 SN - 978-1-61208-271-4 SP - 108 EP - 114 PB - Curren CY - Red Hook, NY ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Ichimura, Hiroki A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel JF - Sensors and actuators. B: Chemical N2 - The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation. Y1 - 2013 U6 - https://doi.org/10.1016/j.snb.2013.04.057 SN - 1873-3077 (E-Journal); 0925-4005 (Print) N1 - Part of special issue "Selected Papers from the 26th European Conference on Solid-State Transducers" VL - 189 SP - 240 EP - 245 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Kayatekin, Muammer B. A1 - Uysal, N. A1 - Resmi, H. T1 - Does antioxidant supplementation alter the effects of acute exercise on erythrocyte aggregation, deformability and endothelium adhesion in untrained rats? Kayatekin, Muammer B.; Uysal N.; Resmi, H.; Bediz, Seref C.; Temiz Artmann, A.; Genç, S.; Tugyan, K. JF - International Journal for Vitamin and Nutrition Research. 75 (2005), H. 4 Y1 - 2005 SN - 0300-9831 SP - 243 EP - 250 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Resmi, Halil A1 - Akhunlar, Hülya A1 - Güner, Gül T1 - In vitro effects of high glucose concentrations on membrane protein sulfhydryl oxidation, G-actin and deformability of human erythrocytes. Resmi, Halil ; Akhunlar, Hülya ; Temiz Artmann, Aysegül ; Güner, Gül JF - Cell biochemistry and function. 23 (2005), H. 3 Y1 - 2005 SN - 0263-6484 SP - 163 EP - 168 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Cavdar, C. A1 - Yenicerioglu, Y. A1 - Caliskan, S. T1 - The effects of intravenous iron treatment on oxidant stress and erythrocyte deformability in haemodialysis patients. Cavdar, C.; Temiz, A.; Yenicerioglu, Y.; Caliskan, S.; Celik, A.; Sifil, A.; Onvural, B.; Camsari, T. JF - Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1 Y1 - 2003 SN - 0036-5599 SP - 77 EP - 82 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yalcin, Ozlem A1 - Resmi, Halil A1 - Baskurt, Oguz K. T1 - Can white blood cell activation be one of the major factors that affect hemorheological parameters during and after exercise? JF - Clinical Hemorheology and Microcirculation. 26 (2002), H. 3 Y1 - 2002 SN - 1386-0291 N1 - = The 11th European Symposium on Clinical Hemorheology, Rouen, France, 19-22 September 2000 SP - 189 EP - 193 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, Oguz K. A1 - Pekcetin, C. A1 - Kandemir, F. T1 - Leukocyte activation, oxidant stress and red blood cell properties after acute, exhausting exercise in rats. Temiz, A.; Baskurt, O. K., Pekcetin, C.; Kandemir, F.; Güre, A. JF - Clinical Hemorheology and Microcirculation. 22 (2000), H. 4 Y1 - 2000 SN - 1386-0291 SP - 253 EP - 259 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yolcuoglu, B. A1 - Onal, M. A. A1 - Sipahi, O. T1 - The effect of skin transplantation on tumour growth in mice. Yolcuoglu, B.; Onal, M. A.; Sipahi, O.; Temiz, A.; Pekcetin, C.; Acikgöz, O.; Kar, H.; Güre A. JF - The American Journal of Surgery. 178 (1999), H. 4 Y1 - 1999 SN - 0002-9610 SP - 329 EP - 330 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Ates, H. A1 - Üretmen, Ö. A1 - Andac, K. T1 - Erythrocyte deformability in high-tension and normal tension glaucoma. Ates, H.; Üretmen, Ö.; Temiz, A.; Andac, K. JF - International Ophthalmology. 22 (1998), H. 1 Y1 - 1998 SN - 0165-5701 SP - 7 EP - 12 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Meiselman, H. J. T1 - Effect of superoxide anions on red blood cell rheologic properties. Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Free Radical Biology and Medicine. 24 (1998), H. 1 Y1 - 1998 SN - 0891-5849 SP - 102 EP - 110 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Meiselman, H. J. T1 - Red blood cell aggregation in experimental sepsis . Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Journal of Laboratory and Clinical Medicine. 130 (1997), H. 2 Y1 - 1997 SN - 0022-2143 SP - 183 EP - 190 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Edremitlioglu, M. T1 - Effect of erythrocyte deformability on myocardial hematocrit gradient. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - American Journal of Physiology: Heart and Circulatory Physiology. 268 (1995), H. 1 Y1 - 1995 SN - 0363-6135 SP - 260 EP - 264 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Edremitlioglu, M. T1 - In vitro effects of in vivo activated leukocytes on red blood cell filterability and lipid peroxidation. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - Clinical Hemorheology. 14 (1994), H. 4 Y1 - 1994 SP - 591 EP - 596 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Akhisaroglu, M. A1 - Sercan, Z. A1 - Kayatekin, B. M. T1 - Adhesion of Erythrocytes to Endothelial Cells After Acute Exercise: Differences in Red Blood Cells from Juvenile and Adult Rats. Temiz Artmann, A.; Akhisaroglu, M.; Sercan, Z.; Kayatekin, BM.; Yorukoglu, K.; Kirkali, G. JF - Physiological Research (2005) Y1 - 2005 SN - 0862-8408 N1 - pre-press article ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Butzer, Paul L. T1 - Semi-groups and resolvent operators JF - Archive for Rational Mechanics and Analysis KW - Resolvent Operator KW - Electromagnetism KW - Complex System KW - Neural Network KW - Nonlinear Dynamics Y1 - 1968 U6 - https://doi.org/10.1007/BF00250941 SN - 0003-9527 VL - 30 IS - 2 SP - 127 EP - 147 PB - Springer CY - Berlin ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Weak smoothness conditions for the uniform convergence of Fourier-Jacobi series JF - Functiones et Approximatio. Commentarii Mathematici. 9 (1980) Y1 - 1980 SN - 0208-6573 N1 - Zentralblatt MATH: http://www.emis.de/MATH-item?0471.42018 SP - 9 EP - 13 ER - TY - JOUR A1 - Turek, Monika A1 - Ketterer, Lothar A1 - Claßen, Melanie A1 - Berndt, Heinz A1 - Elbers, Gereon A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development and Electrochemical Investigations of an EIS-(Electrolyte-Insulator-Semiconductor) based Biosensor for Cyanide Detection JF - Sensors Y1 - 2007 SN - 1424-8220 VL - 7 IS - 8 SP - 1415 EP - 1426 ER - TY - JOUR A1 - Wagner, Torsten A1 - Molina, Roberto A1 - Yoshinobu, Tatsuo A1 - Kloock, Joachim P. A1 - Biselli, Manfred A1 - Canzoneri, Michele A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef T1 - Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications JF - Electrochimica Acta. 53 (2007), H. 2 Y1 - 2007 SN - 0013-4686 SP - 305 EP - 311 ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Schmitt, W. A1 - Meissen, Th. T1 - Aachen 3D finger. 3D digitizer for application in dentistry / Schmitt, W. ; Pawelke, S. ; Meissen, Th. JF - Biomedizinische Technik. 35 (1990), H. 4 Y1 - 1990 SN - 0013-5585 SP - 69 EP - 71 ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Note on Jackson and Bernstein type approximation theorems in the case of approximation by algebraic polynomial in the spaces L and C JF - Studia Scientiarum Mathematicarum Hungarica. 36 (2000), H. 3-4 Y1 - 2000 SN - 0081-6906 SP - 353 EP - 358 ER - TY - JOUR A1 - Sander, Volker A1 - Erwin, Dietmar A1 - Huber, Valentina T1 - High-performance computer management based on Java JF - Future Generation Computer Systems. 15 (1999), H. 3 Y1 - 1999 SN - 0167-739X SP - 425 EP - 432 ER - TY - JOUR A1 - Sander, Volker A1 - Foster, Ian A1 - Roy, Alain A1 - Winkler, Linda T1 - A differentiated services implementation for high-performance TCP flows JF - Computer Networks. 34 (2000), H. 6 Y1 - 2000 SN - 1389-1286 SP - 915 EP - 929 ER - TY - JOUR A1 - Sander, Volker A1 - Czajkowski, K. A1 - Foster, I. A1 - Kesselman, C. T1 - SNAP: A Protocol for Negotiating Service Level Agreements and Coordinating Resource Management in Distributed Systems / Czajkowski, K. ; Foster, I. ; Kesselman, C. ; Sander, V. ; Tuecke, S. JF - Job Scheduling Strategies for Parallel Processing : 8th InternationalWorkshop, JSSPP 2002 Edinburgh, Scotland, UK, July 24, 2002. Revised Papers Y1 - 2002 SN - 3-540-00172-7 N1 - Lecture Notes in Computer Science ; 2537 ; JSSPP <8, 2002, Edinburgh > SP - 153 EP - 183 PB - Springer CY - Berlin ER - TY - BOOK A1 - Sander, Volker T1 - Design and evaluation of a bandwidth broker that provides network quality of service for grid applications Y1 - 2003 SN - 3-00-010002-4 N1 - NIC series ; 16 ; Zugl. Aachen, Techn. Hochsch., Diss., 2002 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Sander, Volker A1 - Roy, Alain T1 - GARA: A Uniform Quality of Service Architecture / Roy, Alain ; Sander, Volker JF - Grid resource management : state of the art and future trends / ed. by Jarek Nabrzyski; Jennifer M. Schopf; Jan W̜eglarz Y1 - 2004 SN - 1-4020-7575-8 N1 - International series in operations research & management science ; 64 SP - 377 EP - 394 PB - Kluwer Academic Publ. CY - Boston ER - TY - JOUR A1 - Sander, Volker A1 - Fidler, Markus T1 - A parameter based admission control for differentiated services networks / Fidler, Markus ; Sander, Volker JF - Computer Networks. 44 (2004), H. 4 Y1 - 2004 SN - 1389-1286 SP - 463 EP - 479 ER - TY - JOUR A1 - Sander, Volker A1 - Foster, Ian T. A1 - Fidler, Markus A1 - Roy, Alain T1 - End-to-end quality of service for high-end applications / Foster, Ian T. ; Fidler, Markus ; Roy, Alain ; Sander, Volker ; Winkler, Linda JF - Computer Communications. 27 (2004), H. 14 Y1 - 2004 SN - 0140-3664 SP - 1375 EP - 1388 ER - TY - JOUR A1 - Sander, Volker A1 - Fidler, Markus A1 - Klimala, Wojciech T1 - Traffic shaping in aggregate-based networks: implementation and analysis / Fidler, Markus ; Sander, Volker ; Klimala, Wojciech JF - Computer Communications. 28 (2005), H. 3 Y1 - 2005 SN - 0140-3664 SP - 274 EP - 286 ER - TY - BOOK A1 - Sander, Volker A1 - Roy, Alain T1 - Advance Reservation API / Roy, Alain ; Sander, Volker Y1 - 2002 N1 - GFD-E.5 Scheduling Working Group Category: Experimental PB - Global Grid Forum ER - TY - BOOK A1 - Sander, Volker T1 - Optical Network Infrastructure for Grid / Simeonidou, Dimitra ... (ed.) Y1 - 2004 N1 - GFD-I.036 Category: Informational ; GHPN-RG PB - Global Grid Forum ER - TY - BOOK A1 - Sander, Volker T1 - Networking Issues for Grid Infrastructure / Sander, Volker (ed.) Y1 - 2004 N1 - GFD-I.037 Category: Informational ; Grid High Performance Networking Research Group PB - Global Grid Forum ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kirchner, Patrick A1 - Ng, Yue Ann A1 - Spelthahn, Heiko A1 - Schneider, Andreas A1 - Henkel, Hartmut A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg A1 - Keusgen, Michael T1 - Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 787 EP - 792 ER - TY - JOUR A1 - Turek, Monik A1 - Heiden, Wolfgang A1 - Guo, Sharon A1 - Riesen, Alfred A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 817 EP - 823 ER -