TY - JOUR A1 - Stulpe, Werner A1 - Singer, Matthias T1 - Some Remarks on the Determination of Quantum States by Measurements JF - Foundations of Physics Letters. 3 (1990), H. 2 Y1 - 1990 SN - 1572-9524 SP - 153 EP - 166 ER - TY - JOUR A1 - Stulpe, Werner A1 - Singer, Matthias T1 - Phase-Space Representations of General Statistical Physical Theories. Singer, Matthias; Stulpe, Werner JF - Journal of Mathematical Physics. 33 (1992), H. 1 Y1 - 1992 SN - 1089-7658 SP - 131 EP - 142 ER - TY - JOUR A1 - Stulpe, Werner A1 - Scholz, Erhard T1 - Hilbert Space / Scholz, Erhard ; Stulpe, Werner JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 291 EP - 295 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner A1 - Ruch, Ernst T1 - Proof of the Mixing Theorem for Statistical Systems in Classical Physics. Ruch, Ernst; Stulpe, Werner JF - Acta Applicandae Mathematicae. 53 (1998), H. 3 Y1 - 1998 SN - 1572-9036 SP - 329 EP - 352 ER - TY - JOUR A1 - Stulpe, Werner A1 - Hellwig, K.-E. T1 - A Formulation of Quantum Stochastic Processes and Some of its Properties. Hellwig, K.-E.; Stulpe, W. JF - Foundations of Physics. 13 (1983), H. 7 Y1 - 1983 SN - 1572-9516 SP - 673 EP - 699 ER - TY - JOUR A1 - Stulpe, Werner A1 - Hellwig, K.-E. T1 - A Classical Reformulation of Finite-Dimensional Quantum Mechanics. Hellwig, K.-E.; Stulpe, W. JF - Quantum measurement, irreversibility and the physics of information / Symposium on the Foundations of Modern Physics 1993, Cologne, Germany 1 - 5 June 1993. Ed. Paul Busch Y1 - 1993 SN - 981021507X N1 - Symposium on the Foundations of Modern Physics ; <1993, Köln> SP - 209 EP - 214 PB - World Scientific CY - Singapore [u.a.] ER - TY - JOUR A1 - Stulpe, Werner A1 - Gudder, S. A1 - Hagler, J. T1 - An Uncertainty Relation for Joint Position-Momentum Measurements JF - Foundations of Physics Letters. 1 (1988), H. 3 Y1 - 1988 SN - 1572-9524 SP - 287 EP - 292 ER - TY - JOUR A1 - Stulpe, Werner A1 - Busch, Paul T1 - The structure of classical extensions of quantum probability theory JF - Journal of Mathematical Physics. 49 (2008), H. 3 Y1 - 2008 SN - 1089-7658 N1 - 032104 SP - 1 EP - 22 ER - TY - JOUR A1 - Stulpe, Werner A1 - Busch, P. A1 - Hellwig, K.-E. T1 - Classical Representations of Finite-Dimensional Quantum Mechanics. Busch, P.; Hellwig, K.-E.; Stulpe, W. JF - International Journal of Theoretical Physics. 32 (1993), H. 3 Y1 - 1993 SN - 1572-9575 SP - 399 EP - 405 ER - TY - JOUR A1 - Stulpe, Werner A1 - Bugajski, S. A1 - Hellwig, K.-E. T1 - On Fuzzy Random Variables and Statistical Maps. Bugajski, S.; Hellwig, K.-E.; Stulpe, W. JF - Reports on Mathematical Physics. 41 (1998), H. 1 Y1 - 1998 SN - 0034-4877 SP - 1 EP - 11 ER - TY - JOUR A1 - Stulpe, Werner A1 - Bjelakovic, Igor T1 - The Projective Hilbert Space as a Classical Phase Space for Nonrelativistic Quantum Dynamics. Bjelakovic, Igor; Stulpe, Werner JF - International Journal of Theoretical Physics. 44 (2005), H. 11 Y1 - 2005 SN - 1572-9575 SP - 2041 EP - 2049 ER - TY - JOUR A1 - Stulpe, Werner T1 - Conditional Expectations and Stochastic Processes in Quantum Probability JF - Information complexity and control in quantum physics : proceedings of the 4. Internat. Seminar on Mathematical Theory of Dynamical Systems and Microphysics, Udine, Sept. 4 - 13, 1985 / ed. by A. Blaquiere ... Y1 - 1987 SN - 3-211-81992-4 N1 - Courses and lectures / International Centre for Mechanical Sciences ; 294, International Seminar on Mathematical Theory of Dynamical Systems and Microphysics <4,1985, Udine> SP - 223 EP - 234 PB - Springer CY - Wien [u.a.] ER - TY - JOUR A1 - Stulpe, Werner T1 - Conditional Expectations, Conditional Distributions, and A Posteriori Ensembles in Generalized Probability Theory JF - International Journal of Theoretical Physics. 27 (1988), H. 5 Y1 - 1988 SN - 1572-9575 SP - 587 EP - 611 ER - TY - JOUR A1 - Stulpe, Werner T1 - On the Representation of Quantum Mechanics on Phase Space JF - International Journal of Theoretical Physics. 31 (1992), H. 9 Y1 - 1992 SN - 1572-9575 SP - 1785 EP - 1795 ER - TY - JOUR A1 - Stulpe, Werner T1 - On the Representation of Quantum Mechanics on a Classical Sample Space JF - International Journal of Theoretical Physics. 37 (1998), H. 1 Y1 - 1998 SN - 1572-9575 SP - 349 EP - 356 ER - TY - JOUR A1 - Stulpe, Werner T1 - Some Remarks on Classical Representations of Quantum Mechanics JF - Foundations of Physics . 24 (1994), H. 7 Y1 - 1994 SN - 1572-9516 SP - 1089 EP - 1094 ER - TY - JOUR A1 - Stulpe, Werner T1 - Density Operator JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 166 EP - 169 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - Operator JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 440 EP - 444 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - Projection JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 497 EP - 499 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - Self-Adjoint Operator JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 692 EP - 697 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - Unitary Operator JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 807 EP - 809 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - From the attempt of certain classical reformulations of quantum mechanics to quasi-probability representations JF - Journal of mathematical physics N2 - The concept of an injective affine embedding of the quantum states into a set of classical states, i.e., into the set of the probability measures on some measurable space, as well as its relation to statistically complete observables is revisited, and its limitation in view of a classical reformulation of the statistical scheme of quantum mechanics is discussed. In particular, on the basis of a theorem concerning a non-denseness property of a set of coexistent effects, it is shown that an injective classical embedding of the quantum states cannot be supplemented by an at least approximate classical description of the quantum mechanical effects. As an alternative approach, the concept of quasi-probability representations of quantum mechanics is considered. Y1 - 2013 U6 - http://dx.doi.org/10.1063/1.4861939 SN - 1089-7658 (Online) SN - 0022-2488 (Print) VL - 55 IS - 1 PB - American Institute of Physics ER - TY - JOUR A1 - Stulpe, Werner T1 - From the attempt of certain classical reformulations of quantum mechanics to quasi-probability representations JF - Journal of Mathematical Physics N2 - The concept of an injective affine embedding of the quantum states into a set of classical states, i.e., into the set of the probability measures on some measurable space, as well as its relation to statistically complete observables is revisited, and its limitation in view of a classical reformulation of the statistical scheme of quantum mechanics is discussed. In particular, on the basis of a theorem concerning a non-denseness property of a set of coexistent effects, it is shown that an injective classical embedding of the quantum states cannot be supplemented by an at least approximate classical description of the quantum mechanical effects. As an alternative approach, the concept of quasi-probability representations of quantum mechanics is considered. Y1 - 2014 U6 - http://dx.doi.org/10.1063/1.4861939 SN - 222-488 N1 - bereits unter gleichem Titel aufgenommen bei arxiv : http://arxiv.org/pdf/1307.2314.pdf VL - 55 IS - 1 PB - AIP Publishing CY - College Park, Md. ER - TY - JOUR A1 - Stulpe, Werner T1 - Aspects of the Quantum-Classical Connection Based on Statistical Maps JF - Foundations of Physics Y1 - 2019 U6 - http://dx.doi.org/10.1007/s10701-019-00269-9 VL - 49 IS - 6 SP - 677 EP - 692 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - Pairwise coexistence of effects versus coexistence JF - Journal of Physics: Conference Series Y1 - 2020 U6 - http://dx.doi.org/10.1088/1742-6596/1638/1/012004 SN - 1742-6596 VL - 1638 IS - 012004 SP - 1 EP - 21 PB - IOP CY - Bristol ER - TY - JOUR A1 - Streun, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - A compact PET detector readout using charge-to-time conversion JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics. Y1 - 2009 SN - 1082-3654 SP - 1868 EP - 1870 PB - IEEE CY - New York ER - TY - JOUR A1 - Streun, M. A1 - Christ, D. A1 - Hellendung, A. A1 - Larue, H. A1 - Ziemons, Karl A1 - Halling, H. T1 - Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 402 EP - 405 ER - TY - JOUR A1 - Streun, M. A1 - Chavan, U. A1 - Lame, H. A1 - Parl, C. A1 - Müller-Veggian, Mattea A1 - Ziemons, Karl T1 - Treating the Gain Non-Uniformity of Multi Channel PMTs by Channel-Specific Trigger Levels JF - 2006 IEEE Nuclear Science Symposium Conference Record, Vol. 2. Y1 - 2006 SN - 1082-3654 SP - 1301 EP - 1304 CY - San Diego, CA ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - 2000 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free running ADCs at a sampling rate of 40 MHz. A four-channel acquisition-board has been developed which is equipped with four 12 bit-ADCs connected to one FPGA (field programmable gate array). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware-trigger can be omitted. The method of free running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. These informations are crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows coping with very high count rates. Since this method is going to be employed in positron emission tomography (PET), the position of an event is another important information. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO-scintillators coupled to the PS-PMT are presented Y1 - 2000 SN - 1082-3654 SP - 9/179 EP - 9/181 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - IEEE Transactions on Nuclear Science N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free-running ADCs at a sampling rate of 40 MHz. A four-channel acquisition board has been developed which is equipped with four 12-bit ADCs connected to one field programmable gate array (FPGA). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware trigger can be omitted. The method of free-running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. This information is crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows very high count rates to be dealt with. Since this method is to be employed in positron emission tomography (PET), the position of an event is also important. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO scintillators coupled to the PS-PMT are presented here Y1 - 2001 SN - 0018-9499 VL - 48 IS - 3 SP - 524 EP - 526 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system with free running ADCs JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 18 EP - 21 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Coincidence detection by digital processing of free-running sampled pulses JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns. Y1 - 2002 SN - 0168-9002 VL - 487 IS - 3 SP - 530 EP - 534 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system based on data processing of free-running sampled pulses JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface. Y1 - 2002 SN - 1082-3654 SP - 693 EP - 694 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 1082-3654 SP - 1636 EP - 1639 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - IEEE Transactions on Nuclear Science N2 - A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 3 SP - 344 EP - 347 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER - TY - JOUR A1 - Streun, M. A1 - Beer, S. A1 - Hombach, T. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - PlanTIS: A positron emission tomograph for imaging 11C transport in plants JF - 2007 IEEE Nuclear Science Symposium Conference Record, Vol. 6 N2 - Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary. Y1 - 2008 SN - 1082-3654 SP - 4110 EP - 4112 ER - TY - JOUR A1 - Streese, Lukas A1 - Kotliar, Konstantin A1 - Deiseroth, Arne A1 - Infanger, Denis A1 - Gugleta, Konstantin A1 - Schmaderer, Christoph A1 - Hanssen, Henner T1 - Retinal endothelial function in cardiovascular risk patients: A randomized controlled exercise trial JF - Scandinavian Journal of Medicine and Science in Sports N2 - The aim of this study was to investigate, for the first time, the effects of high-intensity interval training (HIIT) on retinal microvascular endothelial function in cardiovascular (CV) risk patients. In the randomized controlled trial, middle-aged and previously sedentary patients with increased CV risk (aged 58 ± 6 years) with ≥ two CV risk factors were randomized into a 12-week HIIT (n = 33) or control group (CG, n = 36) with standard physical activity recommendations. A blinded examiner measured retinal endothelial function by flicker light-induced maximal arteriolar (ADmax) and venular (VDmax) dilatation as well as the area under the arteriolar (AFarea) and venular (VFarea) flicker curve using a retinal vessel analyzer. Standardized assessments of CV risk factors, cardiorespiratory fitness, and retinal endothelial function were performed before and after HIIT. HIIT reduced body mass index, fat mass, and low-density lipoprotein and increased muscle mass and peak oxygen uptake (VO2peak). Both ADmax (pre: 2.7 ± 2.1%, post: 3.0 ± 2.2%, P = .018) and AFarea (pre: 32.6 ± 28.4%*s, post: 37.7 ± 30.6%*s, P = .016) increased after HIIT compared with CG (ADmax, pre: 3.2 ± 1.8%, post: 2.9 ± 1.8%, P = .254; AFarea, pre: 41.6 ± 28.5%*s, post: 37.8 ± 27.0%*s, P = .186). Venular function remained unchanged after HIIT. There was a significant association between ∆-change VO2peak and ∆-changes ADmax and AFarea (P = .026, R² = 0.073; P = .019, R² = 0.081, respectively). 12-weeks of HIIT improved retinal endothelial function in middle-aged patients with increased CV risk independent of the reduction in classical CV risk factors. Exercise has the potential to reverse or at least postpone progression of small vessel disease in older adults with increased CV risk under standard medication. Dynamic retinal vessel analysis seems to be a sensitive tool to detect treatment effects of exercise interventions on retinal microvascular endothelial function in middle-aged individuals with increased CV risk. Y1 - 2020 U6 - http://dx.doi.org/10.1111/sms.13560 SN - 1600-0838 VL - 30 IS - 2 SP - 272 EP - 280 PB - Wiley CY - Oxford ER - TY - JOUR A1 - Steinseifer, Ulrich A1 - Kashefi, Ali A1 - Hormes, Marcus A1 - Schoberer, Mark A1 - Orlikowsky, Thorsten A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Schmitz-Rode, Thomas T1 - Miniaturization of ECMO Systems : Engineering Challenges and Methods JF - Artificial Organs. 33 (2009), H. 5 Y1 - 2009 SN - 1525-1594 N1 - Fifth International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion Abstracts SP - A55 EP - A55 ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Büldt, Georg A1 - Zaccai, Guiseppe A1 - Artmann, Gerhard T1 - Dynamics and interactions of hemoglobin in red blood cells JF - Tissue Engineering Part A. 14 (2008), H. 5 Y1 - 2008 SN - 1937-3341 N1 - TERMIS EU 2008 Porto Meeting June 22–26, 2008 Porto Congress Center–Alfândega Portugal SP - 724 EP - 724 ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Garvey, G. J. A1 - Bocahut, A. A1 - Sacquin-Mora, S. A1 - Digel, Ilya A1 - Schneider, G. J. A1 - Natali, F. A1 - Artmann, Gerhard A1 - Zaccai, G. T1 - Thermal fluctuations of haemoglobin from different species : adaptation to temperature via conformational dynamics JF - Journal of the Royal Society Interface N2 - Thermodynamic stability, configurational motions and internal forces of haemoglobin (Hb) of three endotherms (platypus, Ornithorhynchus anatinus; domestic chicken, Gallus gallus domesticus and human, Homo sapiens) and an ectotherm (salt water crocodile, Crocodylus porosus) were investigated using circular dichroism, incoherent elastic neutron scattering and coarse-grained Brownian dynamics simulations. The experimental results from Hb solutions revealed a direct correlation between protein resilience, melting temperature and average body temperature of the different species on the 0.1 ns time scale. Molecular forces appeared to be adapted to permit conformational fluctuations with a root mean square displacement close to 1.2 Å at the corresponding average body temperature of the endotherms. Strong forces within crocodile Hb maintain the amplitudes of motion within a narrow limit over the entire temperature range in which the animal lives. In fully hydrated powder samples of human and chicken, Hb mean square displacements and effective force constants on the 1 ns time scale showed no differences over the whole temperature range from 10 to 300 K, in contrast to the solution case. A complementary result of the study, therefore, is that one hydration layer is not sufficient to activate all conformational fluctuations of Hb in the pico- to nanosecond time scale which might be relevant for biological function. Coarse-grained Brownian dynamics simulations permitted to explore residue-specific effects. They indicated that temperature sensing of human and chicken Hb occurs mainly at residues lining internal cavities in the β-subunits. Y1 - 2012 U6 - http://dx.doi.org/10.1098/rsif.2012.0364 SN - 1742-5689 VL - 9 IS - 76 SP - 2845 EP - 2855 PB - The Royal Society CY - London ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Unruh, Tobias A1 - Büldt, Georg A1 - Zaccai, Guiseppe T1 - Cytoplasmic water and hydration layer dynamics in human red blood cells JF - Journal of the American Chemical Society. 50 (2008), H. 130 Y1 - 2008 SN - 1520-5126 SP - 16852 EP - 16853 ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Digel, Ilya A1 - Embs, Jan P. A1 - Unruh, Tobias A1 - Tehei, M. A1 - Zaccai, G. A1 - Büldt, G. A1 - Artmann, Gerhard T1 - From powder to solution : Hydration dependence of human hemoglobin dynamics correlated to body temperature JF - Biophysical Journal. 96 (2009), H. 12 Y1 - 2009 SN - 0006-3495 SP - 5073 EP - 5081 PB - Cell Press CY - Cambridge, Mass. ER - TY - JOUR A1 - Stadler, A. M. A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Embs, Jan P. A1 - Zaccai, Joe A1 - Büldt, Georg T1 - Hemoglobin Dynamics in Red Blood Cells: Correlation to Body Temperature JF - Biophysical Journal. 95 (2008), H. 11 Y1 - 2008 SN - 1542-0086 SP - 5449 EP - 5461 ER - TY - JOUR A1 - Staat, Manfred A1 - Wolters, J A1 - Bongarts, W. A1 - Hennings, W. (u.a.) T1 - Überarbeitete probabilistisch orientierte Sicherheitsanalyse für den HTR-Modul JF - Jahrestagung Kerntechnik '90 / Kerntechnische Gesellschaft e.V. ; Deutsches Atomforum e.V Y1 - 1990 SP - 143 EP - 146 PB - INFORUM CY - Bonn ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Khoi Duc T1 - Limit loads of circumferentially flawed pipes and cylindrical vessels under internal pressure JF - International Journal of Pressure Vessels and Piping. 83 (2006), H. 3 Y1 - 2006 SN - 0308-0161 SP - 188 EP - 196 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Duc-Khoi T1 - An Algorithm for Shakedown Analysis for Materials with Temperature Dependent Yield Stress JF - Proceedings in Applied Mathematics and Mechanics (PAMM). 4 (2004), H. 1 Y1 - 2004 SN - 1617-7061 SP - 231 EP - 233 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Duc-Khoi T1 - Limit analysis of flaws in pressurized pipes and cylindrical vessels. Part I: Axial defects JF - Engineering Fracture Mechanics. 74 (2007), H. 3 Y1 - 2007 SN - 0013-7944 SP - 431 EP - 450 ER -