TY - JOUR A1 - Staat, Manfred T1 - Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels N2 - Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions. KW - Finite-Elemente-Methode KW - Grenzwertberechnung KW - Axialbelastung KW - FEM KW - Grenzwertberechnung KW - Axialbelastung KW - Traglastanalyse KW - Limit analysis KW - Global and local collapse KW - Axially cracked pipe KW - Pressure loaded crack-face Y1 - 2005 ER - TY - JOUR A1 - Staat, Manfred T1 - Direct finite element route for design-by-analysis of pressure components N2 - In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion. KW - Einspielen KW - Plastizität KW - Deformation KW - Analytischer Zulaessigkeitsnachweis KW - Einspiel-Analyse KW - fortschreitende plastische Deformation KW - alternierend Verformbarkeit KW - Einspiel-Kriterium KW - Design-by-analysis KW - Shakedown analysis KW - Progressive plastic deformation KW - Alternating plasticity KW - Shakedown criterion Y1 - 2005 ER - TY - JOUR A1 - Staat, Manfred T1 - Shakedown and ratchetting under tension-torsion loadings: analysis and experiments N2 - Structural design analyses are conducted with the aim of verifying the exclusion of ratchetting. To this end it is important to make a clear distinction between the shakedown range and the ratchetting range. The performed experiment comprised a hollow tension specimen which was subjected to alternating axial forces, superimposed with constant moments. First, a series of uniaxial tests has been carried out in order to calibrate a bounded kinematic hardening rule. The load parameters have been selected on the basis of previous shakedown analyses with the PERMAS code using a kinematic hardening material model. It is shown that this shakedown analysis gives reasonable agreement between the experimental and the numerical results. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. KW - Einspielen KW - Einspielen KW - Ratchetting KW - Zug-Druck Belastung KW - shakedown KW - ratchetting KW - tension–torsion loading Y1 - 2003 ER - TY - JOUR A1 - Staat, Manfred T1 - Basis Reduction for the Shakedown Problem for Bounded Kinematic Hardening Material N2 - Limit and shakedown analysis are effective methods for assessing the load carrying capacity of a given structure. The elasto–plastic behavior of the structure subjected to loads varying in a given load domain is characterized by the shakedown load factor, defined as the maximum factor which satisfies the sufficient conditions stated in the corresponding static shakedown theorem. The finite element dicretization of the problem may lead to very large convex optimization. For the effective solution a basis reduction method has been developed that makes use of the special problem structure for perfectly plastic material. The paper proposes a modified basis reduction method for direct application to the two-surface plasticity model of bounded kinematic hardening material. The considered numerical examples show an enlargement of the load carrying capacity due to bounded hardening. KW - Finite-Elemente-Methode KW - Einspielen KW - Basis Reduktion KW - konvexe Optimierung KW - FEM KW - Druckgeräte KW - Basis reduction KW - Convex optimization KW - FEM KW - Shakedown analysis Y1 - 2000 ER - TY - JOUR A1 - Staat, Manfred T1 - LISA - a European project for FEM-based limit and shakedown analysis N2 - The load-carrying capacity or the safety against plastic limit states are the central questions in the design of structures and passive components in the apparatus engineering. A precise answer is most simply given by limit and shakedown analysis. These methods can be based on static and kinematic theorems for lower and upper bound analysis. Both may be formulated as optimization problems for finite element discretizations of structures. The problems of large-scale analysis and the extension towards realistic material modelling will be solved in a European research project. Limit and shakedown analyses are briefly demonstrated with illustrative examples. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - Traglastanalyse KW - Einspielanalyse KW - FEM KW - limit analysis KW - shakedown analysis Y1 - 2001 ER - TY - JOUR A1 - Staat, Manfred T1 - Direct FEM Limit and Shakedown Analysis with Uncertain Data N2 - The structural reliability with respect to plastic collapse or to inadaptation is formulated on the basis of the lower bound limit and shakedown theorems. A direct definition of the limit state function is achieved which permits the use of the highly effective first order reliability methods (FORM) is achieved. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis. The limit state function and its gradient are obtained from a mathematical optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error, leading to highly effective and precise reliability analyses. KW - Finite-Elemente-Methode KW - Einspielen KW - FEM KW - Einspielanalyse KW - shakedown KW - limit load KW - reliability analysis KW - FEM KW - direct method Y1 - 2000 ER - TY - JOUR A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty JF - Tap chi Khoa hoc & ung dung - Dai hoc Ton Duc Thang Y1 - 2012 N1 - = Journal of Applied Sciences - Ton Duc Thang University VL - 19 SP - 45 EP - 47 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Unger, J. A1 - Spies, K. H. T1 - Härtebegriff im Zusammenhang mit Vernetzung, Bruchdehnung und Dauerfestigkeit eines Elastomers JF - Kautschuk Gummi Kunststoffe. 56 (2003), H. 11 Y1 - 2003 SN - 0948-3276 SP - 608 EP - 613 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Unger, J. T1 - Organisation und Strukturierung technischer Messungen JF - Werkstattstechnik. 88 (1998), H. 5 Y1 - 1998 SN - 1436-5006 SP - 223 EP - 226 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Spaltofski, R. A1 - Steinhilper, W. T1 - Hochmolekulare Additive für die Gleitlagerschmierung. Spaltofski, R.; Sponagel, S.; Steinhilper, W. JF - Tribologie und Schmierungstechnik. 35 (1988), H. 5 Y1 - 1988 SN - 0036-6218 SP - 236 EP - 241 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Spaltofski, R. T1 - Hochmolekulare Zusätze verbessern die Leichtlaufeigenschaft und die Tragfähigkeit von Schmierfilmen / Sponagel, S. ; Spaltofski, R. JF - Mineralöltechnik. 32 (1987), H. 3 Y1 - 1987 SN - 0341-1893 SP - 28 S. ER - TY - JOUR A1 - Sponagel, Stefan A1 - Müller, H. T1 - Exakte instationäre Lösungen der Navier-Stokes-Gleichung. H. Müller, S. Sponagel JF - Zeitschrift für angewandte Mathematik und Mechanik: ZAMM. 63 (1983) Y1 - 1983 SN - 0044-2267 N1 - weitere ISSN: 0946-8463 SP - T273 EP - T275 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Lutz, Th. T1 - Ein Beitrag zur Bestimmung der Haertewerte von Elastomeren JF - Kautschuk Gummi Kunststoffe. 43 (1990), H. 10 Y1 - 1990 SN - 0022-9520 SP - 861 EP - 865 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Lutz, T. T1 - Aggregatelager JF - Kautschuk Gummi Kunststoffe. 43 (1990), H. 5 Y1 - 1990 SN - 0022-9520 SP - 397 EP - 406 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Kilthau, G. A1 - Spies, K. H. T1 - Sealing mechanism of lip seals JF - Eleventh 11th International Conference on Fluid Sealing : proceedings of the 11th Internat. Conference on Fluid Sealing, held at Cannes, France 8 - 10 April, 1987 / organised and sponsored by BHRA, the Fluid Engineering Centre. Ed. B. S. Nau Y1 - 1987 SN - 3-540-51383-3 N1 - International Conference on Fluid Sealing <11, 1987, Cannes> SP - 748 EP - 772 PB - Elsevier CY - London ER - TY - JOUR A1 - Sponagel, Stefan A1 - Groling, G. T1 - Eine Bemerkung zum Beweis des π Theorems. G. Groling, S. Sponagel JF - Zeitschrift für angewandte Mathematik und Mechanik: ZAMM. 63 (1983) Y1 - 1983 SN - 0044-2267 N1 - weitere ISSN: 0946-8463 SP - T258 EP - T259 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Becker, E. T1 - Reibungsfreie, ebene Diffusorströmung mit beliebigem Einlaufprofil. E. Becker, S. Sponagel JF - Zeitschrift für angewandte Mathematik und Mechanik: ZAMM. 64 (1984) Y1 - 1984 SN - 0044-2267 N1 - weitere ISSN: 0946-8463 SP - T174 EP - T177 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, G. A1 - Steffen, T. A1 - Wu, J. T1 - Parameter identification for cement infiltration of osteoporotic bone JF - Poromechanics II : Proceedings of the Second Biot Conference on Poromechanics Grenoble, France 26 - 28 August 2002 / ed. by J.-L. Auriault ... Y1 - 2002 SN - 90-5809-394-8 SP - 55 EP - 58 PB - Balkema CY - Lisse [u.a.] ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, G. A1 - Falk, R. A1 - Crookshank, M. T1 - Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration. G. Baroud, R. Falk, M. Crookshank, S. Sponagel, T. Steffen JF - Journal of Biomechanics. 37 (2004), H. 2 Y1 - 2004 SN - 0021-9290 SP - 189 EP - 196 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, G. A1 - Falk, R. A1 - Crookshank, M. T1 - Corrigendum to “Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration”. Baroud, G.; Falk, R.; Crookshank, M.; Sponagel, S.; Steffen, T. JF - Journal of Biomechanics. 37 (2004), H. 2 Y1 - 2004 SN - 0021-9290 SP - 1802 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Akbay, U. A1 - Becker, E. A1 - Krozer, S. T1 - Instability of slow viscometric flow JF - Mechanics Research Communications. 7 (1980), H. 4 Y1 - 1980 SN - 0093-6413 SP - 199 EP - 204 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Akbay, U. A1 - Becker, E. T1 - Instability of plane Couette flow of viscoelastic liquids JF - Journal of non-Newtonian fluid mechanics. 18 (1985), H. 2 Y1 - 1985 SN - 0377-0257 SP - 123 EP - 141 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Akbay, U. T1 - Über den Mechanismus der Oberflächeninstabilität viskosimetrischer Strömungen JF - Rheologica Acta. 23 (1984), H. 2 Y1 - 1984 SN - 0035-4511 SP - 185 EP - 188 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Akbay, U. T1 - Über den Relaxationseinfluß auf die Stabilität der ebenen Couette-Strömung. Akbay, U. ; Sponagel, S. JF - Rheologica Acta. 23 (1984), H. 2 Y1 - 1984 SN - 0035-4511 SP - 177 EP - 184 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Akbay, S. T1 - Über die Stabilität viskometrischer Strömungen JF - Rheologica acta. 20 (1981), H. 6 Y1 - 1981 SN - 0035-4511 SP - 579 EP - 590 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Adbay, U. A1 - Becker, E. A1 - Krozer, S. T1 - A possible cause of viscoelastic turbulence JF - Rheology : proceedings of the 8th International Congress of Rheology, held in Naples, Italy, September 1 - 5, 1980 / Hrsg. von Giovanni Astarita, Vol. 2 Y1 - 1980 SN - 0-306-40465-6 SP - 79 EP - 84 PB - Plenum Pr. CY - New York ER - TY - JOUR A1 - Sponagel, Stefan T1 - Analytische Berechnung von Gummi- Metall- Verbindungen JF - Konstruktion : Zeitschrift für Produktentwicklung. 39 (1987), H. 4 Y1 - 1987 SN - 0373-3300 SP - 151 EP - 158 ER - TY - JOUR A1 - Sponagel, Stefan T1 - Der Mensch als Läufer JF - Orthopädie und Sport : [Bericht zum Stolberger Orthopädietag, 13. Juni 1998] Y1 - 1999 SN - 978-3-89124-540-8 N1 - Inhaltsverzeichnis unter http://www.m-m-sports.com/mm_objects/previews/978-3-89124-540-8p.pdf SP - 15 EP - 21 PB - Meyer & Meyer CY - Aachen ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Dünnschichtsensoren für die Schwermetallanalytik JF - GIT : Labor-Fachzeitschrift N2 - Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt. Y1 - 2012 SN - 0016-3538 VL - 56 IS - 4 SP - 285 EP - 287 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Dünnschichtsensoren für die Schwermetallanalytik : Mikroelektroden auf Chalkogenidglasbasis JF - GIT Labor-Fachzeitschrift N2 - Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt. Y1 - 2012 IS - 4 SP - 285 EP - 287 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schaffrath, Sophie A1 - Coppe, Thomas A1 - Rufi, Frederic A1 - Schöning, Michael Josef T1 - Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions JF - Physica status solidi (a) : applications and material science. 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 930 EP - 934 ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Self-aligned nanogaps and nanochannels via conventional photolithography and pattern-size reduction technique JF - Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI Y1 - 2009 SN - 0013-4686 SP - 6010 EP - 6014 ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Kirsanov, Dmitry A1 - Legin, Andrey A1 - Osterrath, Thomas A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Schöning, Michael Josef T1 - Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions JF - Physica Status Solidi (a) N2 - In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed. Y1 - 2012 SN - 1862-6319 U6 - http://dx.doi.org/10.1002/pssa.201100733 VL - 209 IS - 5 SP - 885 EP - 891 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Sousa, Marcos A. M. A1 - Siqueira, Jose R. Jr. A1 - Vercik, Andres A1 - Schöning, Michael Josef A1 - Oliveira, Osvaldo N. Jr. T1 - Determining the optimized layer-by-layer film architecture with dendrimer/carbon nanotubes for field-effect sensors JF - IEEE Sensors Journal N2 - The capacitive electrolyte–insulator–semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte–insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors. Y1 - 2017 U6 - http://dx.doi.org/10.1109/JSEN.2017.2653238 SN - 1558-1748 VL - 17 IS - 6 SP - 1735 EP - 1740 PB - IEEE CY - New York ER - TY - JOUR A1 - Slabu, Ioana A1 - Roeth, Anjali A. A1 - Engelmann, Ulrich M. A1 - Wiekhorst, Frank A1 - Buhl, Eva M. A1 - Neumann, Ulf P. A1 - Schmitz-Rode, Thomas T1 - Modeling of magnetoliposome uptake in human pancreatic tumor cells in vitro JF - Nanotechnology Y1 - 2019 U6 - http://dx.doi.org/10.1088/1361-6528/ab033e SN - 1361-6528 VL - 30 IS - 18 SP - 184004 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices JF - Physica status solidi (a). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 781 EP - 786 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Penicillin biosensor based on a capacitive field-effect structure functionalized with a dendrimer/carbon nanotube multilayer JF - Biosensors and Bioelectronics. 25 (2009), H. 2 Y1 - 2009 SN - 0956-5663 SP - 497 EP - 501 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Abouzar, Maryam H. A1 - Bäcker, Matthias A1 - Zucolotto, Valtencir A1 - Poghossian, Arshak A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Carbon nanotubes in nanostructured films: Potential application as amperometric and potentiometric field-effect (bio-)chemical sensors JF - physica status solidi (a) . 206 (2009), H. 3 Y1 - 2009 SN - 1862-6319 N1 - Special Issue: Engineering of Functional Interfaces (EnFI 08) SP - 462 EP - 467 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Werner, Frederik A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors JF - Journal of Physical Chemistry C. 113 (2009), H. 33 Y1 - 2009 SN - 1932-7455 SP - 14765 EP - 14770 PB - American Chemical Society CY - Washington, DC ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Molinnus, Denise A1 - Beging, Stefan A1 - Schöning, Michael Josef T1 - Incorporating a hybrid urease-carbon nanotubes sensitive nanofilm on capacitive field-effect sensors for urea detection JF - Analytical chemistry N2 - The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor’s surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance–voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (∼18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform. Y1 - 2014 U6 - http://dx.doi.org/10.1021/ac500458s SN - 1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print) VL - 86 IS - 11 SP - 5370 EP - 5375 PB - ACS Publications CY - Columbus ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Maki, Rafael M. A1 - Paulovich, Fernando V. A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Oliveira, Maria C. F. de A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Use of Information Visualization Methods Eliminating Cross Talk in Multiple Sensing Units Investigated for a Light-Addressable Potentiometric Sensor JF - Analytical Chemistry (2010) Y1 - 2010 SN - 0003-2700 SP - 61 EP - 65 ER - TY - JOUR A1 - Simonis, A. A1 - Ruge, C. A1 - Müller-Veggian, Mattea A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - A long-term stable macroporoustype EIS structure for electrochemical sensor applications JF - Sensors and Actuators B. 91 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 21 EP - 25 ER - TY - JOUR A1 - Simonis, A. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - Miniaturisierte Referenzelektroden in Siliziumtechnologie für elektrochemische Sensoranwendungen JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 847 EP - 850 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Simonis, A. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - New concepts of miniaturised reference electrodes in silicon technology for potentiometric sensor systems JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 429 EP - 435 ER - TY - JOUR A1 - Simonis, A. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - Strategies of miniaturised reference electrodes integrated in a silicon-based „one chip“ pH sensor JF - Sensors. 3 (2003), H. 9 Y1 - 2003 SN - 1424-8220 SP - 330 EP - 339 ER - TY - JOUR A1 - Simonis, A. A1 - Krings, T. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - A „hybrid“ thin-film pH sensor with integrated thick-film reference JF - Sensors. 1 (2001), H. 6 Y1 - 2001 SN - 1424-8220 SP - 183 EP - 192 ER - TY - JOUR A1 - Simonis, A. A1 - Dawgul, M. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technology JF - Electrochimica Acta. 51 (2005), H. 5 Y1 - 2005 SN - 0013-4686 U6 - http://dx.doi.org/10.1016/j.electacta.2005.04.063 SP - 930 EP - 937 ER - TY - JOUR A1 - Sildatke, Michael A1 - Karwanni, Hendrik A1 - Kraft, Bodo A1 - Zündorf, Albert T1 - A distributed microservice architecture pattern for the automated generation of information extraction pipelines JF - SN Computer Science N2 - Companies often build their businesses based on product information and therefore try to automate the process of information extraction (IE). Since the information source is usually heterogeneous and non-standardized, classic extract, transform, load techniques reach their limits. Hence, companies must implement the newest findings from research to tackle the challenges of process automation. They require a flexible and robust system that is extendable and ensures the optimal processing of the different document types. This paper provides a distributed microservice architecture pattern that enables the automated generation of IE pipelines. Since their optimal design is individual for each input document, the system ensures the ad-hoc generation of pipelines depending on specific document characteristics at runtime. Furthermore, it introduces the automated quality determination of each available pipeline and controls the integration of new microservices based on their impact on the business value. The introduced system enables fast prototyping of the newest approaches from research and supports companies in automating their IE processes. Based on the automated quality determination, it ensures that the generated pipelines always meet defined business requirements when they come into productive use. KW - Architectural design KW - Model-driven software engineering KW - Software and systems modeling KW - Enterprise information systems KW - Information extraction Y1 - 2023 U6 - http://dx.doi.org/10.1007/s42979-023-02256-4 SN - 2661-8907 N1 - Corresponding authors: Michael Sildatke, Hendrik Karwanni IS - 4, Article number: 833 PB - Springer Singapore CY - Singapore ER - TY - JOUR A1 - Seynnes, O. R. A1 - Bojsen-Moller, J. A1 - Albracht, Kirsten A1 - Arndt, A. A1 - Cronin, N. J. A1 - Finni, T. A1 - Magnusson, S. P. T1 - Ultrasound-based testing of tendon mechanical properties: a critical evaluation JF - Journal of Applied Physiology Y1 - 2015 U6 - http://dx.doi.org/10.1152/japplphysiol.00849.2014 SN - 8750-7587 VL - 118 IS - 2 SP - 133 EP - 141 ER - TY - JOUR A1 - Seifarth, Volker A1 - Schehl, D. A1 - Linder, Peter A1 - Gossmann, Matthias A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Porst, Dariusz A1 - Preiß, C. A1 - Kayser, Peter A1 - Pack, O. A1 - Temiz Artmann, Aysegül T1 - Ureplace: development of a bioreactor for in vitro culturing of cell seeded tubular vessels on collagen scaffolds N2 - The demand of replacements for inoperable organs exceeds the amount of available organ transplants. Therefore, tissue engineering developed as a multidisciplinary field of research for autologous in-vitro organs. Such three dimensional tissue constructs request the application of a bioreactor. The UREPLACE bioreactor is used to grow cells on tubular collagen scaffolds OPTIMAIX Sponge 1 with a maximal length of 7 cm, in order to culture in vitro an adequate ureter replacement. With a rotating unit, (urothelial) cells can be placed homogeneously on the inner scaffold surface. Furthermore, a stimulation is combined with this bioreactor resulting in an orientation of muscle cells. These culturing methods request a precise control of several parameters and actuators. A combination of a LabBox and the suitable software LabVision is used to set and conduct parameters like rotation angles, velocities, pressures and other important cell culture values. The bioreactor was tested waterproof successfully. Furthermore, the temperature controlling was adjusted to 37 °C and the CO2 - concentration regulated to 5 %. Additionally, the pH step responses of several substances showed a perfect functioning of the designed flow chamber. All used software was tested and remained stable for several days. KW - Tissue Engineering KW - Bioreaktor KW - Organkultur KW - Harnleiter Y1 - 2011 ER -