TY - JOUR A1 - Weckesser, Martin A1 - Grießmeier, Martin A1 - Schmidt, Daniela A1 - Sonnenberg, Frank A1 - Ziemons, Karl A1 - Kemna, Lars A1 - Holschbach, Marcus A1 - Langen, Karl-J. A1 - Müller-Gärtner, Hans-W. T1 - Iodine-123 α-methyl tyrosine single-photon emission tomography of cerebral gliomas: standardised evaluation of tumour uptake and extent JF - European Journal of Nuclear Medicine N2 - Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7%±6.1% (range 2.7%–25.0%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0.0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment. Y1 - 1998 SN - 1619-7089 VL - 25 IS - 2 SP - 150 EP - 156 ER - TY - JOUR A1 - Ziemons, Karl A1 - Kleines, H. A1 - Erken, I. A1 - Knoben, J. A1 - Zwoll, K. ED - Lehmann, Thomas T1 - IME-DV Projekt: M-FIRBe, Multi-Modality Functional Imaging for Brain Research JF - Bildverarbeitung für die Medizin : Algorithmen - Systeme - Anwendungen Y1 - 1997 SN - 3-86073-519-5 N1 - Proceedings des Aachener Workshops am 8. u. 9. November 1996 ; WG_005 Arbeitsgruppenvorstellungen SP - 363 EP - 366 PB - Verl. der. Augustinus-Buchh. CY - Aachen ER - TY - JOUR A1 - Kleines, H. A1 - Erki, I. A1 - Ziemons, Karl A1 - Zwoll, K. ED - Lehmann, Thomas T1 - ATM- und Multimedia Pilotsystem im Rahmen des Projektes M-FIBRe Aufbau und Erfahrungen JF - Bildverarbeitung für die Medizin : Algorithmen - Systeme - Anwendungen Y1 - 1997 SN - 3-86073-519-5 N1 - Proceedings des Aachener Workshops am 8. u. 9. November 1996 ; PP_001 Posterpräsentation SP - 241 EP - 248 PB - Verl. der. Augustinus-Buchh. CY - Aachen ER - TY - JOUR A1 - Erki, I. A1 - Kleines, H. A1 - Ziemons, Karl A1 - Zwoll, K. ED - Lehmann, Thomas T1 - Interaktives System zur Darstellung funktionaler Bilddaten JF - Bildverarbeitung für die Medizin : Algorithmen - Systeme - Anwendungen Y1 - 1997 SN - 3-86073-519-5 N1 - Proceedings des Aachener Workshops am 8. u. 9. November 1996 ; PP_002 Posterpräsentation SP - 249 EP - 254 PB - Verl. der. Augustinus-Buchh. CY - Aachen ER - TY - JOUR A1 - Langen, Karl J. A1 - Ziemons, Karl A1 - Kiwit, Jürgen C. W. A1 - Herzog, Hans A1 - Kuwert, Torsten A1 - Bock, Wolfgang A1 - Stöcklin, Gerhard A1 - Feinendegen, Ludwig E. A1 - Müller-Gärtner, Hans-W. T1 - 3-[123I]iodo-α-methyltyrosine and [methyl-11C]-L-methionine uptake in cerebral gliomas: a compara-tive study using SPECT and PET JF - Journal of Nuclear Medicine Y1 - 1997 SN - 0161-5505 VL - 38 IS - 4 SP - 517 EP - 522 ER - TY - JOUR A1 - Weckesser, Matthias A1 - Hufnagel, Andreas A1 - Ziemons, Karl A1 - Grießmeier, Martin A1 - Sonnenberg, Frank A1 - Hackländer, Thomas A1 - Langen, Karl-J. A1 - Holschbach, Markus A1 - Elger, Christian E. A1 - Müller-Gärtner, Hans-W. T1 - Effect of partial volume correction on muscarinic cholinergic receptor imaging with single-photon emission tomography in patients with temporal lobe epilepsy JF - European Journal of Nuclear Medicine N2 - Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [123I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration. Y1 - 1997 SN - 1619-7089 VL - 24 IS - 9 SP - 1156 EP - 1161 ER - TY - JOUR A1 - Schmidt, Daniela A1 - Langen, Karl-J. A1 - Herzog, Hans A1 - Wirths, Jochen A1 - Holschbach, Markus A1 - Kiwit, Jürgen C. W. A1 - Ziemons, Karl A1 - Coenen, Heinz-H. A1 - Müller-Gärtner, Hans-W. T1 - Whole-body kinetics and dosimetry of L-3[123I]-iodo-α-methyltyrosine JF - European Journal of Nuclear Medicine Y1 - 1997 SN - 1619-7089 VL - 24 IS - 9 SP - 1162 EP - 1166 ER - TY - JOUR A1 - Grießmeier, M. A1 - Sonnenberg, F. A1 - Weckesser, M. A1 - Ziemons, Karl A1 - Langen, K.-J. A1 - Müller-Gärtner, H. W. T1 - Improvement of SPECT quantification in small brain structures by using experiment based recovery-coefficient corrections JF - European Journal of Nuclear Medicine Y1 - 1996 SN - 1619-7089 N1 - Abstracts ; PSu827 VL - 23 IS - 9 SP - 1238 EP - 1238 ER - TY - JOUR A1 - Boecker, Henning A1 - Kuwert, Torsten A1 - Langen, Karl-J. A1 - Lange, Herwig W. A1 - Czech, Norbert A1 - Ziemons, Karl A1 - Herzog, Hans A1 - Shikare, Shekar A1 - Weindl, Anton A1 - Feinendegen, Ludwig E. T1 - SPECT with HMPAO compared to PET with FDG in Huntington disease JF - Journal of Computer Assisted Tomography Y1 - 1994 SN - 1532-3145 VL - 18 IS - 4 SP - 542 EP - 548 ER - TY - JOUR A1 - Ziemons, Karl T1 - A measurement of the ratio of the nucleon structure function in copper and deuterium JF - Zeitschrift für Physik C Particles and Fields N2 - Results are presented on the ratios of the nucleon structure function in copper to deuterium from two separate experiments. The data confirm that the nucleon structure function,F 2, is different for bound nucleons than for the quasi-free ones in the deuteron. The redistribution in the fraction of the nucleon's momentum carried by quarks is investigated and it is found that the data are compatible with no integral loss of quark momenta due to nuclear effects. Y1 - 1993 SN - 1431-5858 N1 - European Muon Collaboration VL - 57 IS - 2 SP - 211 EP - 218 ER - TY - JOUR A1 - Ziemons, Karl T1 - Muoproduction of J/ψ and the gluon distribution of the nucleon JF - Zeitschrift für Physik C Particles and Fields N2 - Measurements are presented of the inclusive distributions of the J/Ψ meson produced by muons of energy 200 GeV from an ammonia target. The gluon distribution of the nucleon has been derived from the data in the range 0.04