TY - JOUR A1 - Bergmann, Sandra A1 - Demuth, Bastian A1 - Sander, Volker T1 - A Web Framework for Workflow Submission and Monitoring via UNICORE 6 based on Distributable Scientific Workflow Templates JF - UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.) Y1 - 2011 SN - 9783893367504 N1 - UNICORE Summit ; (2011 ; 2011.07.07-08 ; Torun) ; Schriften des Forschungszentrums Jülich IAS Series 9 SP - 45 EP - 50 PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Krott, Daniel A1 - Gerhards, Michael A1 - Skorupa, Sascha A1 - Sander, Volker T1 - NHiLA - Bridging the Gap Between .NET and UNICORE JF - UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.) Y1 - 2011 SN - 9783893367504 N1 - UNICORE Summit ; (2011 ; 2011.07.07-08 ; Torun) ; Schriften des Forschungszentrums Jülich IAS Series 9 SP - 77 EP - 86 PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Gerhards, M. A1 - Skorupa, S. A1 - Sander, Volker A1 - Pfeiffer, P. A1 - Belloum, A. T1 - Towards a security framework for a WS-HumanTask processor JF - 7th International Conference on Network and Service Management (CNSM), 2011 Paris Y1 - 2011 SN - 978-3-901882-44-9 SP - 1 EP - 5 PB - IEEE CY - New York ER - TY - JOUR A1 - Bäcker, Matthias A1 - Raue, Markus A1 - Schusser, Sebastian A1 - Jeitner, C. A1 - Breuer, L. A1 - Wagner, P. A1 - Poghossian, Arshak A1 - Förster, Arnold A1 - Mang, Thomas A1 - Schöning, Michael Josef T1 - Microfluidic chip with integrated microvalves based on temperature- and pH-responsive hydrogel thin films JF - Physica Status Solidi (a) N2 - Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3–12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off. Y1 - 2012 U6 - http://dx.doi.org/10.1002/pssa.201100763 SN - 1862-6319 VL - 209 IS - 5 SP - 839 EP - 845 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Dünnschichtsensoren für die Schwermetallanalytik JF - GIT : Labor-Fachzeitschrift N2 - Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt. Y1 - 2012 SN - 0016-3538 VL - 56 IS - 4 SP - 285 EP - 287 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Novacek, V. A1 - Tran, Thanh Ngoc A1 - Klinge, U. A1 - Tolba, R. H. A1 - Staat, Manfred A1 - Bronson, D. G. A1 - Miesse, A. M. A1 - Whiffen, J. A1 - Turquier, F. T1 - Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design JF - Journal of Biomechanics N2 - The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge. KW - Variable height stapler design KW - Anastomotic leakage KW - Finite element modelling KW - End-to-end colorectal anastomosis KW - Surgical staplers Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.021 SN - 1873-2380 VL - 45 IS - 115 SP - 2693 EP - 2697 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nguyen, Nhu Huynh A1 - Duong, Minh Tuan A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Grottke, O. A1 - Tolba, R. A1 - Staat, Manfred T1 - Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs JF - Journal of Biomechanics N2 - The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines. KW - Autolysis KW - Decomposition KW - Freeze–thaw process KW - Spleen KW - Liver Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.008 SN - 1873-2380 VL - 45 IS - 14 SP - 2382 EP - 2386 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines M. T1 - Can vascular function be assessed by the interpretation of retinal vascular diameter changes? JF - Investigative Ophthalmology & Visual Science, IOVS. 52 (2011), H. 1 Y1 - 2011 SN - 0146-0404 SP - 635 EP - 636 PB - ARVO CY - Rockville, Md. ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Mücke, Bruno A1 - Vilser, Walthard A1 - Schilling, Rudolf T1 - Effect of aging on retinal artery blood column diameter measured along the vessel axis / Kotliar, Konstantin E. ; Mücke, Bruno ; Vilser, Walthard ; Schilling, Rudolf ; Lanzl, Ines M. JF - Investigative Ophthalmology & Visual Science, IOVS. 49 (2008), H. 5 Y1 - 2008 SN - 0146-0404 SP - 2094 EP - 2102 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines M. A1 - Hanssen, Henner A1 - Eberhardt, Karla A1 - Vilser, Walthard A1 - Halle, Martin A1 - Heemann, Uwe A1 - Schmidt-Trucksäss, Arno A1 - Baumann, Marcus T1 - Does increased blood pressure rather than aging influence retinal pulse wave velocity? JF - Investigative Ophthalmology & Visual Science, IOVS N2 - Purpose: It was demonstrated previously that retinal pulse wave velocity (rPWV) as a measure of retinal arterial stiffness is increased in aged anamnestically healthy volunteers compared with young healthy subjects. Using novel methodology of rPWV assessment this finding was confirmed and investigated whether it might relate to the increased blood pressure usually accompanying the aging process, rather than to the aging itself. Methods: A total of 12 young 25.5-year-old (24.0–28.8) [median(1st quartile–3rd quartile)] and 12 senior 68.5-year-old (63.8–71.8) anamnestically healthy volunteers; and 12 senior 63.0-year-old (60.8–65.0) validated healthy volunteers and 12 young 33.0-year-old (29.5–35.0) hypertensive patients were examined. Time-dependent alterations of vessel diameter were assessed by the Dynamic Vessel Analyzer in a retinal artery of each subject. The data were filtered and processed using mathematical signal analysis and rPWVs were calculated. Results: rPWV amounted to 1200 (990-1470) RU (relative units)/s in the hypertensive group and to 1040 (700-2230) RU/s in anamnestically healthy seniors. These differed significantly from rPWVs in young healthy group (410 [280–500] RU/s) and in validated healthy seniors (400 [320–510] RU/s). rPWV associated with age and mean arterial pressure (MAP) in the pooled cohort excluded validated healthy seniors. In a regression model these associations remain when alternately adjusted for MAP and age. When including validated healthy seniors in the pooled cohort only association with MAP remains. Conclusions: Both aging (with not excluded cardiovascular risk factors) and mild hypertension are associated with elevated rPWV. rPWV increases to a similar extent both in young mildly hypertensive subjects and in aged anamnestically healthy persons. Healthy aging is not associated with increased rPWV. Y1 - 2012 U6 - http://dx.doi.org/10.1167/iovs.11-8815 SN - 0146-0404 VL - 53 IS - 4 SP - 2119 EP - 2126 PB - ARVO CY - Rockville, Md. ER - TY - JOUR A1 - Lustfeld, H. A1 - Pithan, C. A1 - Reißel, Martin T1 - Metallic electrolyte composites in the framework of the brick-layer model JF - Journal of the European Ceramic Society N2 - It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jeurceramsoc.2011.10.017 SN - 0955-2219 VL - 32 IS - 4 SP - 859 EP - 864 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Detaillierte Berechnung der Einfangwirksamkeiten von Fangeinrichtungen JF - Elektro-Praktiker N2 - Im Beitrag wird zunächst das Verfahren eines dynamischen elektro-geometrischen Modells vorgestellt. Dieses arbeitet im Gegensatz zum klassischen Blitzkugel-Verfahren nicht mit konstanten Radien; vielmehr wird der Radius der Blitzkugel variiert. Dabei werden ausschließlich vorhandene und in internationalen Normen anerkannte Ergebnisse, blitzphysikalische Grundlagen und Untersuchungen verwendet, und auf deren Grundlage ein numerisches Verfahren erarbeitet. Mit dem dynamischen elektro-geometrischen Modell werden dann einige Beispiele des Schutzes mit Fangstangen, die gemäß dem klassischen Blitzkugel-Verfahren nach DIN EN 62305-3 für die Schutzklassen I – II – III – IV geplant sind, untersucht. Es wird gezeigt, dass die Einfangwirksamkeiten wesentlich höher sind als in der Normenreihe DIN EN 62305 selbst angegeben. Grund dafür ist die Tatsache, dass das Blitzkugel-Verfahren sehr konservativ aufgebaut ist und dem Planer von Blitzschutzsystemen nur die möglichen Stellen für einen Einschlag aufzeigt, ohne eine Bewertung der Einschlagshäufigkeit zu liefern. Andererseits bedeutet dies jedoch, dass man mit dem klassischen Blitzkugel-Verfahren stets auf der „sicheren Seite“ liegt. Y1 - 2012 SN - 0013-5569 VL - 66 IS - 4 PB - Huss Medien CY - Berlin ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fuchs, K. A1 - Fleischer, M. A1 - Schöning, Michael Josef A1 - Wagner, P. T1 - Monitoring of irritant gas using a whole-cell-based sensor system JF - Sensors and Actuators B: Chemical N2 - Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2012.05.088 SN - 0925-4005 VL - 175 SP - 208 EP - 217 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hillen, Walter A1 - Alper Selver, M. A1 - Fischer, Felix A1 - Kuntalp, Mehmet T1 - A software tool for interactive generation, representation, and systematical storage of transfer functions for 3D medical images / Alper Selver, M. ; Fischer, Felix ; Kuntalp, Mehmet ; Hillen, Walter JF - Computer Methods and Programs in Biomedicine. 86 (2007), H. 3 Y1 - 2007 SN - 0169-2607 SP - 270 EP - 280 PB - - ER - TY - JOUR A1 - Kurulgan Demirci, Eylem A1 - Demirci, Taylan A1 - Linder, Peter A1 - Trzewik, Jürgen A1 - Gierkowski, Jessica Ricarda A1 - Gossmann, Matthias A1 - Kayser, Peter A1 - Porst, Dariusz A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - rhAPC reduces the endothelial cell permeability via a decrease of contractile tensions induced by endothelial cells JF - Journal of Bioscience and Bioengineering N2 - All cells generate contractile tension. This strain is crucial for mechanically controlling the cell shape, function and survival. In this study, the CellDrum technology quantifying cell's (the cellular) mechanical tension on a pico-scale was used to investigate the effect of lipopolysaccharide (LPS) on human aortic endothelial cell (HAoEC) tension. The LPS effect during gram-negative sepsis on endothelial cells is cell contraction causing endothelium permeability increase. The aim was to finding out whether recombinant activated protein C (rhAPC) would reverse the endothelial cell response in an in-vitro sepsis model. In this study, the established in-vitro sepsis model was confirmed by interleukin 6 (IL-6) levels at the proteomic and genomic levels by ELISA, real time-PCR and reactive oxygen species (ROS) activation by florescence staining. The thrombin cellular contraction effect on endothelial cells was used as a positive control when the CellDrum technology was applied. Additionally, the Ras homolog gene family, member A (RhoA) mRNA expression level was checked by real time-PCR to support contractile tension results. According to contractile tension results, the mechanical predominance of actin stress fibers was a reason of the increased endothelial contractile tension leading to enhanced endothelium contractility and thus permeability enhancement. The originality of this data supports firstly the basic measurement principles of the CellDrum technology and secondly that rhAPC has a beneficial effect on sepsis influenced cellular tension. The technology presented here is promising for future high-throughput cellular tension analysis that will help identify pathological contractile tension responses of cells and prove further cell in-vitro models. KW - Cell permeability KW - Cellular force KW - Endothelial cells KW - Recombinant activated protein C KW - Lipopolysaccharide KW - Contractile tension KW - CellDrum Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiosc.2012.03.019 SN - 1347-4421 VL - 113 IS - 2 SP - 212 EP - 219 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hanssen, H. A1 - Nickel, T. A1 - Drexel, V. A1 - Hertel, G. A1 - Emslander, I. A1 - Sisic, Z. A1 - Lorang, D. A1 - Schuster, T. A1 - Kotliar, Konstantin A1 - Pressler, A. A1 - Schmidt-Trucksäss, A. A1 - Weis, M. A1 - Halle, M. T1 - Exercise-induced alterations of retinal vessel diameters and cardiovascular risk reduction in obesity JF - Atherosclerosis Y1 - 2011 SN - 0021-9150 VL - 216 IS - 2 SP - 433 EP - 439 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Reisert, Steffen A1 - Pütz, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Characterisation of polymeric materials as passivation layer for calorimetric H2O2 gas sensors JF - Physica Status Solidi (a) N2 - Calorimetric gas sensors for monitoring the H₂O₂ concentration at elevated temperatures in industrial sterilisation processes have been presented in previous works. These sensors are built up in form of a differential set-up of a catalytically active and passive temperature-sensitive structure. Although, various types of catalytically active dispersions have been studied, the passivation layer has to be established and therefore, chemically as well as physically characterised. In the present work, fluorinated ethylene propylene (FEP), perfluoralkoxy (PFA) and epoxy-based SU-8 photoresist as temperature-stable polymeric materials have been investigated for sensor passivation in terms of their chemical inertness against H₂O₂, their hygroscopic properties as well as their morphology. The polymeric materials were deposited via spin-coating on the temperature-sensitive structure, wherein spin-coated FEP and PFA show slight agglomerates. However, they possess a low absorption of humidity due to their hydrophobic surface, whereas the SU-8 layer has a closed surface but shows a slightly higher absorption of water. All of them were inert against gaseous H₂O₂ during the characterisation in H₂O₂ atmosphere that demonstrates their suitability as passivation layer for calorimetric H₂O₂ gas sensors. Y1 - 2012 U6 - http://dx.doi.org/10.1002/pssa.201100773 SN - 1862-6319 VL - 209 IS - 5 SP - 859 EP - 863 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Kirsanov, Dmitry A1 - Legin, Andrey A1 - Osterrath, Thomas A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Schöning, Michael Josef T1 - Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions JF - Physica Status Solidi (a) N2 - In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed. Y1 - 2012 SN - 1862-6319 U6 - http://dx.doi.org/10.1002/pssa.201100733 VL - 209 IS - 5 SP - 885 EP - 891 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlowa, O. V. A1 - Makarov, F. N. T1 - Biomechanical analysis of traditional and contemporary conceptions on pathogenesis of the primary open angle glaucoma / Koshitz, I. N. ; Svetlova, O. V. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A. JF - Glaukoma (2005) Y1 - 2005 N1 - Original in Russisch SP - 41 EP - 63 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Svetlova, O. V. A1 - Stegaev, V. A. A1 - Parkhomov, S. D. T1 - Biomechanical substantiation of relatively low efficiency of recurrent laser trabeculoplasty / Svetlova, O. V. ; Stagaev, V. A. ; Parkhomov, S. D. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A. ; Koshitz, I. N. JF - Glaukoma (2004) Y1 - 2004 N1 - Original in Russisch SP - 29 EP - 39 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Svetlova, O. V. A1 - Sourjikov, A. V. A1 - Zaseeva, M. V. T1 - Biomechanical peculiarities of aqueous humor production system and outflow regulation system / Svetlova, O. V. ; Sourjikov, A. V. ; Kotliar, K. E. ; Zaseeva, M. V. ; Shukhaev, S. V. ; Koshitz, I. N. JF - Glaukoma (2004) Y1 - 2004 N1 - Original in Russisch SP - 66 EP - 76 PB - - ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Kaneko, Kazumi A1 - Matsuo, Akira A1 - Wagner, Torsten A1 - Kanoh, Shiníchiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Miniaturized chemical imaging sensor system using an OLED display panel JF - Sensors and Actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated. KW - LAPS KW - Light-addressable potentiometric sensor KW - Chemical imaging sensor KW - Organic light-emitting diode display Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2011.02.029 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 82 EP - 87 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Leinhos, Marcel A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Characterization of biodegradable polymers with capacitive field-effect sensors JF - Sensors and actuators B: Chemical N2 - In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance–voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor. KW - Impedance spectroscopy KW - C–V method KW - Real-time monitoring KW - Poly(d,l-lacticacid) KW - (Bio)degradation KW - Field-effect sensor Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2012.07.099 SN - 0925-4005 N1 - Part of special issue "Selected Papers from the 14th International Meeting on Chemical Sensors" VL - 187 SP - 2 EP - 7 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Rysstad, Gunnar A1 - Schöning, Michael Josef A1 - Keusgen, Michael T1 - Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Sensors and Actuators B: Chemical N2 - A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes. KW - Sterilisation process KW - Hydrogen peroxide KW - Polyimide KW - Calorimetric gas sensor Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2011.01.032 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 60 EP - 66 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Atlas, Glen A1 - Brealey, David A1 - Dhar, Sunil A1 - Dikta, Gerhard A1 - Singer, Meryvn T1 - Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting JF - Journal of clinical monitoring and computing N2 - The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated. KW - Acceleration KW - Velocity KW - Kinetic energy KW - Force KW - Compliance KW - Afterload KW - Contractility KW - Volume status KW - Esophageal Doppler monitor Y1 - 2012 SN - 1573-2614 U6 - http://dx.doi.org/10.1007/s10877-012-9386-5 IS - 26 SP - 473 EP - 482 PB - Springer Nature CY - London ER - TY - JOUR A1 - Digel, Ilya T1 - Primary thermosensory events in cells JF - Transient receptor potential channels / Md. Shahidul Islam, ed. Y1 - 2011 SN - 978-94-007-0264-6 N1 - (Advances in experimental medicine and biology ; 704) SP - 451 EP - 468 PB - Springer CY - Dordrecht [u.a.] ER - TY - JOUR A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - The emperor's new body : seeking for a blueprint of limb regeneration in humans JF - Stem cell engineering : principles and applications / Gerhard M. Artmann ... eds. Y1 - 2011 SN - 978-3-642-11864-7 SP - 3 EP - 37 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Digel, Ilya T1 - Controlling microbial adhesion : a surface engineering approach JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 601 EP - 625 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Bassam, Rasha A1 - Hescheler, Jürgen A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Digel, Ilya T1 - Effects of spermine NONOate and ATP on the thermal stability of hemoglobin JF - BMC Biophysics N2 - Background Minor changes in protein structure induced by small organic and inorganic molecules can result in significant metabolic effects. The effects can be even more profound if the molecular players are chemically active and present in the cell in considerable amounts. The aim of our study was to investigate effects of a nitric oxide donor (spermine NONOate), ATP and sodium/potassium environment on the dynamics of thermal unfolding of human hemoglobin (Hb). The effect of these molecules was examined by means of circular dichroism spectrometry (CD) in the temperature range between 25°C and 70°C. The alpha-helical content of buffered hemoglobin samples (0.1 mg/ml) was estimated via ellipticity change measurements at a heating rate of 1°C/min. Results Major results were: 1) spermine NONOate persistently decreased the hemoglobin unfolding temperature T u irrespectively of the Na + /K + environment, 2) ATP instead increased the unfolding temperature by 3°C in both sodium-based and potassium-based buffers and 3) mutual effects of ATP and NO were strongly influenced by particular buffer ionic compositions. Moreover, the presence of potassium facilitated a partial unfolding of alpha-helical structures even at room temperature. Conclusion The obtained data might shed more light on molecular mechanisms and biophysics involved in the regulation of protein activity by small solutes in the cell. KW - Nitric Oxide Donor KW - NONOate KW - Circular Dichroism KW - Nitric Oxide Y1 - 2012 U6 - http://dx.doi.org/10.1186/2046-1682-5-16 SN - 2046-1682 VL - 5 PB - BioMed Central CY - London ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Digel, Ilya A1 - Embs, Jan P. A1 - Unruh, Tobias A1 - Tehei, M. A1 - Zaccai, G. A1 - Büldt, G. A1 - Artmann, Gerhard T1 - From powder to solution : Hydration dependence of human hemoglobin dynamics correlated to body temperature JF - Biophysical Journal. 96 (2009), H. 12 Y1 - 2009 SN - 0006-3495 SP - 5073 EP - 5081 PB - Cell Press CY - Cambridge, Mass. ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Unruh, Tobias A1 - Büldt, Georg A1 - Zaccai, Guiseppe T1 - Cytoplasmic water and hydration layer dynamics in human red blood cells JF - Journal of the American Chemical Society. 50 (2008), H. 130 Y1 - 2008 SN - 1520-5126 SP - 16852 EP - 16853 ER - TY - JOUR A1 - Digel, Ilya A1 - Kayser, Peter A1 - Artmann, Gerhard T1 - Molecular processes in biological thermosensation JF - Journal of Biophysics. 2008 (2008) Y1 - 2008 SN - 1687-8000 SP - 1 EP - 9 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Svetlova, O. V. A1 - Makarov, F. N. A1 - Zaseeva, M. V. T1 - Morfologicheskie i funktsional'nye osobennosti resnichnogo poiaska khrustalika kak kliuchevogo ispolnitel'nogo zvena v mekhanizme akkommodatsii glaza cheloveka = Morpho-functional characteristics of lens ciliary body as a key mechanism of accommodation in JF - Morfologiia (Saint Petersburg, Russia). 123 (2003), H. 3 Y1 - 2003 SN - 1026-3543 N1 - Original in Russisch, English abstract SP - 7 EP - 16 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Volkov, V. V. A1 - Koshits, I. N. A1 - Svetlova, O. V. T1 - Biomekhanicheskie osobennosti vzaimodeĭstviia drenazhno i akkomodatsionnoĭ reguliatornykh sistem glaza v norme i pri kontuzionnom podvyvikhe khrustalika / Volkov, V. V. ; Kotliar, K. E. ; Koshits, I. n. ; Svetlova, O. V. ; Smol´nikov, B. A. JF - Vestnik oftalmologii. 113 (1997), H. 3 Y1 - 1997 SN - 0042-465X N1 - Titelübersetzung: Biomechanical characteristics of interactions between the drainage and accommodation regulatory systems of the eye in health and in contusion lens subluxation ; Original in Russisch, English abstract SP - 5 EP - 7 PB - - ER - TY - JOUR A1 - Maier, M. M. A1 - Feucht, N. A1 - Winkler von Mohrenfels, C. A1 - Kotliar, Konstantin A1 - Fabian, E. A1 - Lohmann, C. P. T1 - Nahtlose Cerclage mit Skleratunnelfixation. Sutureless Encircling Band - Clinical Experience JF - Klinische Monatsblätter für Augenheilkunde Y1 - 2011 SN - 0344-6360 VL - 228 IS - 5 SP - 473 EP - 476 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Mikielewicz, Marek A1 - Kotliar, Konstantin A1 - Barraquer, Rafael I. A1 - Michael, Ralph T1 - Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus JF - British Journal of Ophthalmology (eBJO) Y1 - 2011 SN - 1468-2079 VL - 95 IS - 6 SP - 793 EP - 798 PB - BMJ Publ. Group CY - London ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Baumann, Marcus A1 - Vilser, Walthard A1 - Lanzl, Ines M. T1 - Pulse wave velocity in retinal arteries of healthy volunteers JF - British Journal of Ophthalmology (eBJO) Y1 - 2011 SN - 1468-2079 VL - 95 IS - 11 SP - 675 EP - 679 PB - BMJ Publ. Group CY - London ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines M. A1 - Schmidt-Trucksäss, A. A1 - Sitnikova, Diana A1 - Ali, Mohammad A1 - Blume, Katharina A1 - Halle, Martin A1 - Hansser, Henner T1 - Dynamic retinal vessel response to flicker in obesity: A methodological approach JF - Microvascular Research Y1 - 2011 SN - 0026-2862 VL - 81 IS - 1 SP - 123 EP - 128 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dashevsky, Alexey V. A1 - Lanzl, Ines M. A1 - Kotliar, Konstantin T1 - Non-penetrating intracanalicular partial trabeculectomy via the ostia of Schlemm's canal JF - Graefe's Archive for Clinical and Experimental Ophthalmology Y1 - 2011 SN - 0721-832x VL - 249 IS - 4 SP - 565 EP - 573 PB - Springer CY - Berlin ER - TY - JOUR A1 - Baumann, Marcus A1 - Schwarz, Sonja A1 - Kotliar, Konstantin A1 - Eynatten, Maximilian von A1 - Trucksaess, Arno A1 - Burckhardt, Klaus A1 - Lutz, Jens A1 - Heemann, Uwe A1 - Lanzl, Ines T1 - Non-diabetic chronic kidney disease influences retinal microvasculature JF - Kidney and Blood Pressure Research Y1 - 2009 SN - 1423-0143 VL - 32 IS - 6 SP - 428 EP - 433 PB - - ER - TY - JOUR A1 - Burkhardt, Klaus A1 - Schwarz, Sonja A1 - Pan, Chengrui A1 - Stelter, Felix A1 - Kotliar, Konstantin A1 - Eynatten, Maxilian von A1 - Sollinger, Daniel A1 - Lanzl, Ines A1 - Heemann, Uwe A1 - Baumann, Marcus T1 - Myeloid-related protein 8/14 complex describes microcirculatory alterations in patients with type 2 diabetes and nephropathy JF - Cardiovascular Diabetology Y1 - 2009 SN - 1475-2840 VL - 8 IS - 10 SP - 1 EP - 8 PB - - ER - TY - JOUR A1 - Gutheil, Inge A1 - Berg, Tommy A1 - Grotendorst, Johannes T1 - Performance Analysis of Parallel Eigensolvers of two Libraries on BlueGene/P JF - Journal of Mathematics and Systems Science N2 - Many applications in computational science and engineering require the computation of eigenvalues and vectors of dense symmetric or Hermitian matrices. For example, in DFT (density functional theory) calculations on modern supercomputers 10% to 30% of the eigenvalues and eigenvectors of huge dense matrices have to be calculated. Therefore, performance and parallel scaling of the used eigensolvers is of upmost interest. In this article different routines of the linear algebra packages ScaLAPACK and Elemental for parallel solution of the symmetric eigenvalue problem are compared concerning their performance on the BlueGene/P supercomputer. Parameters for performance optimization are adjusted for the different data distribution methods used in the two libraries. It is found that for all test cases the new library Elemental which uses a two-dimensional element by element distribution of the matrices to the processors shows better performance than the old ScaLAPACK library which uses a block-cyclic distribution. KW - performance analysis KW - Elemental KW - ScaLAPACK KW - eigensolvers KW - Numerical linear algebra Y1 - 2012 U6 - http://dx.doi.org/10.17265/2159-5291/2012.04.003 SN - 2159-5291 VL - 2 IS - 4 SP - 231 EP - 236 PB - David Publishing CY - Libertyville ER - TY - JOUR A1 - Grotendorst, Johannes T1 - Supercomputer programmieren - ein besonderes Studienangebot in Jülich JF - Junge Wissenschaft. 27 (2012), H. 94 Y1 - 2012 SN - 0179-8529 SP - 12 EP - 14 PB - - ER - TY - JOUR A1 - Grotendorst, Johannes T1 - IAS Winter School: Hierarchical Methods for Dynamics in Complex Molecular Systems JF - Innovatives Supercomputing in Deutschland : inSiDE. 10 (2012), H. 1 Y1 - 2012 SP - 104 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Kozlova, Tatiana V. A1 - Lanzl, Ines M. T1 - Postoperative aqueous outflow in the human eye after glaucoma filtration surgery: biofluidmechanical considerations JF - Biomedizinische Technik = Biomedical Engineering Y1 - 2009 SN - 1862-278X VL - 54 IS - 1 SP - 14 EP - 22 PB - - ER - TY - JOUR A1 - Seidova, Seid-Fatima A1 - Kotliar, Konstantin A1 - Foerger, Frauke A1 - Klopfer, Matthias A1 - Lanzl, Ines T1 - Functional retinal changes in Gaucher disease JF - Documenta Ophthalmologica Y1 - 2009 SN - 1573-2622 VL - 118 IS - 2 SP - 151 EP - 154 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines M. A1 - Maier, Mathias A1 - Feucht, Nikolaus T1 - Intraocular pressure effects of pegaptanib (macugen) injections in patients with and without glaucoma / Lanzl, Ines M. ; Maier, Mathias ; Feucht, Nikolaus ; Lohmann, Chris P. ; Kotliar, Konstantin E. JF - American Journal of Ophthalmology . 145 (2008), H. 1 Y1 - 2008 SN - 1879-1891 SP - 185 EP - 185 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Vilser, Walthatd A1 - Nagel, Edgar A1 - Lanzl, Ines M. T1 - Retinal vessel reaction in response to chromatic flickering light / Kotliar, Konstantin E. ; Vilser, Walthard ; Nagel, Edgar ; Lanzl, Ines M. JF - Graefe's Archive for Clinical and Experimental Ophthalmology. 242 (2004), H. 5 Y1 - 2004 SN - 1435-702X SP - 377 EP - 392 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Bauer, S. M. A1 - Zamuraev, L. A. T1 - Model of the transversely isotropic spherical layer for estimation of intraocular pressure changes after intravitreal injections / Bauer, S. M. ; Zamuraev, L. A. ; Kotliar, K. E. JF - Rossiiskii zhurnal biomekhaniki = Russian Journal of biomechanics. 10 (2006), H. 2 Y1 - 2006 SN - 1812-5123 SP - 41 EP - 47 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Svetlova, O. V. A1 - Zinoviewa, N. V. A1 - Krylova, I. S. T1 - Elaboration of the conception of the biomechanical model of the aqueous intraocular outflow / Svetlova, O. V. ; Zinoviewa, N. V. ; Krylova, I. S. ; Koshitz, I. N. ; Smolnikov, B. A. ; Fedorova, E. M. ; Kotliar, K. E. JF - Rossiiskii zhurnal biomekhaniki = Russian Journal of biomechanics. 5 (2001), H. 3 Y1 - 2001 SN - 1812-5123 SP - 23 EP - 27 PB - - ER -