TY - JOUR A1 - Amin, Rashid A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Lazarovici, Philip A1 - Lelkes, Peter I. T1 - Permeability of an In Vitro Model of Blood Brain Barrier (BBB) JF - 13th International Conference on Biomedical Engineering / Lim, Chwee Teck [Ed.] Y1 - 2009 SN - 978-3-540-92841-6 N1 - IFMBE Proceedings ; 23, Track 1 ; ICBME 2008 3–6 December 2008 Singapore SP - 81 EP - 84 ER - TY - JOUR A1 - Kuchler, Timon A1 - Günthner, Roman A1 - Ribeiro, Andrea A1 - Hausinger, Renate A1 - Streese, Lukas A1 - Wöhnl, Anna A1 - Kesseler, Veronika A1 - Negele, Johanna A1 - Assali, Tarek A1 - Carbajo-Lozoya, Javier A1 - Lech, Maciej A1 - Adorjan, Kristina A1 - Stubbe, Hans Christian A1 - Hanssen, Henner A1 - Kotliar, Konstantin A1 - Haller, Berhard A1 - Heemann, Uwe A1 - Schmaderer, Christoph T1 - Persistent endothelial dysfunction in post-COVID-19 syndrome and its associations with symptom severity and chronic inflammation N2 - Background Post-COVID-19 syndrome (PCS) is a lingering disease with ongoing symptoms such as fatigue and cognitive impairment resulting in a high impact on the daily life of patients. Understanding the pathophysiology of PCS is a public health priority, as it still poses a diagnostic and treatment challenge for physicians. Methods In this prospective observational cohort study, we analyzed the retinal microcirculation using Retinal Vessel Analysis (RVA) in a cohort of patients with PCS and compared it to an age- and gender-matched healthy cohort (n = 41, matched out of n = 204). Measurements and main results PCS patients exhibit persistent endothelial dysfunction (ED), as indicated by significantly lower venular flicker-induced dilation (vFID; 3.42% ± 1.77% vs. 4.64% ± 2.59%; p = 0.02), narrower central retinal artery equivalent (CRAE; 178.1 [167.5–190.2] vs. 189.1 [179.4–197.2], p = 0.01) and lower arteriolar-venular ratio (AVR; (0.84 [0.8–0.9] vs. 0.88 [0.8–0.9], p = 0.007). When combining AVR and vFID, predicted scores reached good ability to discriminate groups (area under the curve: 0.75). Higher PCS severity scores correlated with lower AVR (R = − 0.37 p = 0.017). The association of microvascular changes with PCS severity were amplified in PCS patients exhibiting higher levels of inflammatory parameters. Conclusion Our results demonstrate that prolonged endothelial dysfunction is a hallmark of PCS, and impairments of the microcirculation seem to explain ongoing symptoms in patients. As potential therapies for PCS emerge, RVA parameters may become relevant as clinical biomarkers for diagnosis and therapy management. KW - Endothelial dysfunction KW - Long COVID KW - Post-COVID-19 syndrome KW - retinal microvasculature Y1 - 2023 U6 - http://dx.doi.org/10.1007/s10456-023-09885-6 N1 - Corresponding author: Christoph Schmaderer VL - 26 SP - 547 EP - 563 PB - Springer Nature CY - Dordrecht ER - TY - CHAP A1 - Schartner, Karl-Heinz A1 - Loeb, H. W. A1 - Dachwald, Bernd A1 - Ohndorf, Andreas T1 - Perspectives of electric propulsion for outer planetary and deep space missions T2 - European Planetary Science Congress 2009 N2 - Solar-electric propulsion (SEP) is superior with respect to payload capacity, flight time and flexible launch window to the conventional interplanetary transfer method using chemical propulsion combined with gravity assists. This fact results from the large exhaust velocities of electric low–thrust propulsion and is favourable also for missions to the giant planets, Kuiper-belt objects and even for a heliopause probe (IHP) as shown in three studies by the authors funded by DLR. They dealt with a lander for Europa and a sample return mission from a mainbelt asteroid [1], with the TANDEM mission [2]; the third recent one investigates electric propulsion for the transfer to the edge of the solar system. All studies are based on triple-junction solar arrays, on rf-ion thrusters of the qualified RIT-22 type and they use the intelligent trajectory optimization program InTrance [3]. Y1 - 2009 N1 - European Planetary Science Congress 2009, 13-18 September, Potsdam, Germany SP - 416 EP - 416 ER - TY - JOUR A1 - Arinkin, Vladimir A1 - Digel, Ilya A1 - Porst, Dariusz A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Phenotyping date palm varieties via leaflet cross-sectional imaging and artificial neural network application JF - BMC bioinformatics N2 - Background True date palms (Phoenix dactylifera L.) are impressive trees and have served as an indispensable source of food for mankind in tropical and subtropical countries for centuries. The aim of this study is to differentiate date palm tree varieties by analysing leaflet cross sections with technical/optical methods and artificial neural networks (ANN). Results Fluorescence microscopy images of leaflet cross sections have been taken from a set of five date palm tree cultivars (Hewlat al Jouf, Khlas, Nabot Soltan, Shishi, Um Raheem). After features extraction from images, the obtained data have been fed in a multilayer perceptron ANN with backpropagation learning algorithm. Conclusions Overall, an accurate result in prediction and differentiation of date palm tree cultivars was achieved with average prediction in tenfold cross-validation is 89.1% and reached 100% in one of the best ANN. Y1 - 2014 U6 - http://dx.doi.org/10.1186/1471-2105-15-55 SN - 1471-2105 VL - 15 IS - 55 SP - 1 EP - 8 ER - TY - JOUR A1 - Heiligers, Jeannette A1 - Schoutetens, Frederic A1 - Dachwald, Bernd T1 - Photon-sail equilibria in the alpha centauri system JF - Journal of Guidance, Control, and Dynamics Y1 - 2021 U6 - http://dx.doi.org/10.2514/1.G005446 SN - 1533-3884 SN - 0731-5090 SN - 0162-3192 VL - 44 IS - 5 SP - 1053 EP - 1061 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Stadler, Andreas M. T1 - Physical discontinuities at body temperature in human red blood cells / Artmann, GM ; Zerlin, K ; Digel, I ; Stadler, A ; Zaccai, G ; Temiz, AA JF - Tissue Engineering. 13 (2007), H. 7 Y1 - 2007 SN - 1076-3279 N1 - TERMIS-EU Meeting Abstracts London, UK September 4–7, 2007 SP - 1778 EP - 1778 ER - TY - JOUR A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues JF - Asia pacific journal on computational engineering Y1 - 2015 U6 - http://dx.doi.org/10.1186/s40540-015-0015-x SN - 2196-1166 VL - 2 IS - 3 (December 2015) SP - 1 EP - 18 ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues T2 - Advances in Composite Material Y1 - 2017 SN - 978-1-61896-300-0 (Hardcover), 978-1-61896-299-7 (Paperback) N1 - Chapter 5 PB - Scientific Research Publishing CY - Wuhan ER - TY - JOUR A1 - Savitskaya, I. S. A1 - Kistaubayeva, A. S. A1 - Digel, Ilya A1 - Shokatayeva, D. H. T1 - Physicochemical and Antibacterial Properties of Composite Films Based on Bacterial Cellulose and Chitosan for Wound Dressing Materials JF - Eurasian Chemico-Technological Journal Y1 - 2017 U6 - http://dx.doi.org/10.18321/ectj670 SN - 2522-4867 VL - 19 IS - 3 SP - 255 EP - 264 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlova, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part I Initial theoretical presuppositions, hypotheses and facts / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotli JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 35 EP - 53 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlowa, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part II Promising algorithms of practical sparing applications / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotliar JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 51 EP - 70 PB - - ER - TY - JOUR A1 - Stadler, Alexander Maximilian A1 - Garvey, Christopher J. A1 - Embs, Jan Peter A1 - Koza, Michael Marek A1 - Unruh, Tobias A1 - Artmann, Gerhard A1 - Zaccai, Guiseppe T1 - Picosecond dynamics in haemoglobin from different species: A quasielastic neutron scattering study JF - Biochimica et biophysica acta (BBA): General Subjects Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.bbagen.2014.06.007 SN - 1872-8006 (E-Journal); 0304-4165 (Print) VL - 1840 IS - 10 SP - 2989 EP - 2999 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Nojima, H. T1 - Plasma cluster ions (PCI) influence on microbial cells viability : [abstract] N2 - Recently, SHARP corporation has developed the world’s first “Plasma Cluster Ions (PCI)” air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp. KW - Clusterion KW - Raumluft KW - Luftreiniger KW - Plasmacluster ion technology KW - Air purification Y1 - 2003 ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Nojima, H. A1 - Artmann, Gerhard T1 - Plasma-generated cluster ions' effects on indoor microflora : [abstract] N2 - Recently, SHARP corporation has developed the world’s first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered. KW - Clusterion KW - Raumluft KW - Luftreiniger KW - Plasmacluster ion technology KW - Air purification Y1 - 2003 ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels JF - Nuclear Engineering and Design. 234 (2004), H. 1-3 Y1 - 2004 SN - 0029-5493 SP - 25 EP - 43 ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels N2 - Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2004 ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Peper, Andreas A1 - Bierbaum, Stefanie A1 - Albracht, Kirsten T1 - Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain JF - Journal of Biomechanics N2 - The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.jbiomech.2010.08.014 SN - 0021-9290 VL - 43 IS - 16 SP - 3073 EP - 3079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Mademli, Lida A1 - Albracht, Kirsten T1 - Plasticity of the human tendon to short and long-term mechanical loading JF - Exercise and Sport Sciences Reviews Y1 - 2009 U6 - http://dx.doi.org/10.1097/JES.0b013e31819c2e1d SN - 1538-3008 VL - 37 IS - 2 SP - 66 EP - 72 ER - TY - JOUR A1 - Michael, Hackl A1 - Mayer, Katharina A1 - Weber, Mareike A1 - Staat, Manfred A1 - van Riet, Roger A1 - Burkhart, Klau Josef A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Plate osteosynthesis of proximal ulna fractures : a biomechanical micromotion analysis JF - The journal of hand surgery Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jhsa.2017.05.014 SN - 0363-5023 VL - 42 IS - 10 SP - 834.e1 EP - 834.e7 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Maggakis-Kelemen, Christina A1 - Digel, Ilya A1 - Artmann, Gerhard T1 - Polystyrene sulfonate/Polyallylamine hydrochloride microcapsules as potential artificial red blood cells - improvement of capsule flexibility JF - Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1 Y1 - 2005 SP - 324 EP - 326 ER - TY - JOUR A1 - Ciritsis, Alexander A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kuhl, Christiane K. A1 - Kraemer, Nils Andreas T1 - Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo JF - Journal of Biomedical Materials Research: Part B: Applied Biomaterials N2 - Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018. Y1 - 2018 U6 - http://dx.doi.org/10.1002/jbm.b.33877 SN - 1552-4981 VL - 106 IS - 2 SP - 827 EP - 833 PB - Wiley CY - New York, NY ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Kozlova, Tatiana V. A1 - Lanzl, Ines M. T1 - Postoperative aqueous outflow in the human eye after glaucoma filtration surgery: biofluidmechanical considerations JF - Biomedizinische Technik = Biomedical Engineering Y1 - 2009 SN - 1862-278X VL - 54 IS - 1 SP - 14 EP - 22 PB - - ER - TY - JOUR A1 - Jayaraman, Chandrasekaran A1 - Mummidisetty, Chaitanya Krishna A1 - Loesch, Alexandra A1 - Kaur, Sandi A1 - Hoppe-Ludwig, Shenan A1 - Staat, Manfred A1 - Jayaraman, Arun T1 - Postural and metabolic benefits of using a forearm support walker in older adults with impairments JF - Archives of Physical Medicine and Rehabilitation Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.apmr.2018.10.001 SN - 0003-9993 VL - Volume 100 IS - Issue 4 SP - 638 EP - 647 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dachwald, Bernd A1 - Baturkin, Volodymyr A1 - Coverstone, Victoria L. A1 - Dietrich, Benjamin A1 - Garbe, Gregory P. A1 - Görlich, Marianne A1 - Leipold, Manfred A1 - Lura, Franz A1 - Macdonald, Malcolm A1 - McInnes, Colin R. A1 - Mengali, Giovanni A1 - Quatra, Alessandro A. A1 - Rios-Reyes, Leonel A1 - Scheeres, Daniel J. A1 - Seboldt, Wolfgang A1 - Wie, Bong T1 - Potential Effects of Optical Solar Sail Degradation on Interplanetary Trajectory Design JF - Astrodynamics 2005 : proceedings of the AAS/AIAA astrodynamics conference held August 7 - 11, 2005, South Lake Tahoe, California / ed. by Bobby G. Williams. - Pt. 3. - (Advances in the astronautical sciences ; 123,3) Y1 - 2006 UR - http://www.spacesailing.net/paper/200508_LakeTahoe_Dachwald+.pdf SN - 0-87703-527-X N1 - Astrodynamics Conference <2005, South Lake Tahoe, Calif.> ; American Astronautical Society ; Number: AAS-05-413 SP - 2569 EP - 2592 PB - Univelt CY - San Diego, Calif. ER - TY - CHAP A1 - Dachwald, Bernd A1 - Baturkin, Volodymyr A1 - Coverstone, Victoria A1 - Diedrich, Ben A1 - Garbe, Gregory A1 - Görlich, Marianne A1 - Leipold, Manfred A1 - Lura, Franz A1 - Macdonald, Malcolm A1 - McInnes, Colin A1 - Mengali, Giovanni A1 - Quarta, Alessandro A1 - Rios-Reyes, Leonel A1 - Scheeres, Daniel J. A1 - Seboldt, Wolfgang A1 - Wie, Bong T1 - Potential effects of optical solar sail degredation on trajectory design T2 - AAS/AIAA Astrodynamics Specialist N2 - The optical properties of the thin metalized polymer films that are projected for solar sails are assumed to be affected by the erosive effects of the space environment. Their degradation behavior in the real space environment, however, is to a considerable degree indefinite, because initial ground test results are controversial and relevant inspace tests have not been made so far. The standard optical solar sail models that are currently used for trajectory design do not take optical degradation into account, hence its potential effects on trajectory design have not been investigated so far. Nevertheless, optical degradation is important for high-fidelity solar sail mission design, because it decreases both the magnitude of the solar radiation pressure force acting on the sail and also the sail control authority. Therefore, we propose a simple parametric optical solar sail degradation model that describes the variation of the sail film’s optical coefficients with time, depending on the sail film’s environmental history, i.e., the radiation dose. The primary intention of our model is not to describe the exact behavior of specific film-coating combinations in the real space environment, but to provide a more general parametric framework for describing the general optical degradation behavior of solar sails. Using our model, the effects of different optical degradation behaviors on trajectory design are investigated for various exemplary missions. Y1 - 2005 N1 - 2005 AAS/AIAA Astrodynamics Specialist Conference, 7-11.08.2005. Lake Tahoe, California https://www.space-flight.org/AAS_meetings/2005_astro/2005_astro.html SP - 1 EP - 23 ER - TY - JOUR A1 - Dachwald, Bernd A1 - Seboldt, Wolfgang A1 - Macdonald, Malcolm A1 - Mengali, Giovanni A1 - Quatra, Alessandro A. A1 - McInnes, Colin R. A1 - Rios-Reyes, Leonel A1 - Scheerers, Daniel J. A1 - Wie, Bong A1 - Görlich, Marianne A1 - Lura, Franz A1 - Diedrich, Benjamin A1 - Baturkin, Volodymyr A1 - Coverstone, Victoria L. A1 - Leipold, Manfred A1 - Garbe, Gregory P. T1 - Potential Solar Sail Degradation Effects on Trajectory and Attitude Control JF - AIAA Guidance, Navigation and Control Conference and Exhibit - AIAA Modeling and Simulation Technologies Conference and Exhibit - AIAA Atmospheric Flight Mechanics Conference and Exhibit : [San Francisco, California, 15 - 18 August 2005 ; papers]. - (AIAA meeting papers on disc ; [10.]2005,16-17) Y1 - 2005 SN - 1-56347-765-3 N1 - American Institute of Aeronautics and Astronautics ; AIAA Guidance, Navigation, and Control Conference and Exhibit <2005, San Francisco, Calif.> ; AIAA paper number: AIAA-2006-6172 Link "https://arc.aiaa.org/doi/book/10.2514/MGNC05" am 15.07.2022 nachgetragen Behr PB - American Institute of Aeronautics and Astronautics CY - Reston, Va. ER - TY - JOUR A1 - Savitskaya, Irina A1 - Zhantlessova, Sirina A1 - Kistaubayeva, Aida A1 - Ignatova, Ludmila A1 - Shokatayeva, Dina A1 - Sinyavsky, Yuriy A1 - Kushugulova, Almagul A1 - Digel, Ilya T1 - Prebiotic cellulose–pullulan matrix as a “vehicle” for probiotic biofilm delivery to the host large intestine JF - Polymers N2 - This study describes the development of a new combined polysaccharide-matrix-based technology for the immobilization of Lactobacillus rhamnosus GG (LGG) bacteria in biofilm form. The new composition allows for delivering the bacteria to the digestive tract in a manner that improves their robustness compared with planktonic cells and released biofilm cells. Granules consisting of a polysaccharide matrix with probiotic biofilms (PMPB) with high cell density (>9 log CFU/g) were obtained by immobilization in the optimized nutrient medium. Successful probiotic loading was confirmed by fluorescence microscopy and scanning electron microscopy. The developed prebiotic polysaccharide matrix significantly enhanced LGG viability under acidic (pH 2.0) and bile salt (0.3%) stress conditions. Enzymatic extract of feces, mimicking colon fluid in terms of cellulase activity, was used to evaluate the intestinal release of probiotics. PMPB granules showed the ability to gradually release a large number of viable LGG cells in the model colon fluid. In vivo, the oral administration of PMPB granules in rats resulted in the successful release of probiotics in the colon environment. The biofilm-forming incubation method of immobilization on a complex polysaccharide matrix tested in this study has shown high efficacy and promising potential for the development of innovative biotechnologies. KW - immobilization KW - prebiotic KW - bacterial cellulose KW - biofilms KW - Lactobacillus rhamnosus GG Y1 - 2023 U6 - http://dx.doi.org/10.3390/polym16010030 N1 - This article belongs to the Section "Polymer Composites and Nanocomposites" IS - 16(1) PB - MDPI CY - Basel ER - TY - JOUR A1 - Kezerashvili, Roman Ya A1 - Dachwald, Bernd T1 - Preface: Solar sailing: Concepts, technology, and missions II JF - Advances in Space Research Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.asr.2021.01.037 SN - 0273-1177 VL - 67 IS - 9 SP - 2559 EP - 2560 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Knott, Thomas C. A1 - Sofronia, Raluca E. A1 - Gerressen, Marcus A1 - Law, Yuen A1 - Davidescu, Arjana A1 - Savii, George G. A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Kuhlen, Torsten W. T1 - Preliminary bone sawing model for a virtual reality-based training simulator of bilateral sagittal split osteotomy T2 - Biomedical simulation : 6th International Symposium, ISBMS 2014, Strasbourg, France, October 16-17, 2014 : proceedings (Lecture notes in computer science : vol. 8789) N2 - Successful bone sawing requires a high level of skill and experience, which could be gained by the use of Virtual Reality-based simulators. A key aspect of these medical simulators is realistic force feedback. The aim of this paper is to model the bone sawing process in order to develop a valid training simulator for the bilateral sagittal split osteotomy, the most often applied corrective surgery in case of a malposition of the mandible. Bone samples from a human cadaveric mandible were tested using a designed experimental system. Image processing and statistical analysis were used for the selection of four models for the bone sawing process. The results revealed a polynomial dependency between the material removal rate and the applied force. Differences between the three segments of the osteotomy line and between the cortical and cancellous bone were highlighted. KW - Bone sawing KW - virtual reality KW - training simulator Y1 - 2014 SN - 978-3-319-12057-7 (Online) SN - 978-3-319-12056-0 (Print) U6 - http://dx.doi.org/10.1007/978-3-319-12057-7_1 SP - 1 EP - 10 PB - Springer CY - Cham ER - TY - CHAP A1 - Peloni, A. A1 - Ceriotti, M. A1 - Dachwald, Bernd T1 - Preliminary trajectory design of a multiple NEO rendezvous mission through solar sailing T2 - Proceedings of the International Astronautical Congress, IAC, Vol. 8, 2014 Y1 - 2015 SN - 978-1-63439-986-9 SP - 5352 EP - 5366 PB - Curran CY - Red Hook, NY ER - TY - JOUR A1 - Rausch, Valentin A1 - Kahmann, Stephanie Lucina A1 - Baltschun, Christoph A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study JF - The Journal of Hand Surgery N2 - Purpose Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state. Methods Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow. Results With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique. Conclusions Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon. Clinical relevance Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.01.006 SN - 0363-5023 VL - 45 IS - 8 SP - 776.e1 EP - 776.e9 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Abel, Alexander A1 - Pérez-Viana, Daniel A1 - Ciritsis, Bernard A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Prevention of femur neck fractures through femoroplasty T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 114 EP - 115 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Digel, Ilya T1 - Primary thermosensory events in cells JF - Transient receptor potential channels / Md. Shahidul Islam, ed. Y1 - 2011 SN - 978-94-007-0264-6 N1 - (Advances in experimental medicine and biology ; 704) SP - 451 EP - 468 PB - Springer CY - Dordrecht [u.a.] ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Staat, Manfred T1 - Probabilistic limit and shakedown analysis of thin plates and shells JF - Structural safety. 31 (2009), H. 1 Y1 - 2009 SN - 0167-4730 SP - 1 EP - 18 PB - - ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Probabilistic limit and shakedown problems JF - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. Y1 - 2003 SN - 3-00-010001-6 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael ED - Staat, Manfred ED - Heitzer, Michael T1 - Probabilistic limit and shakedown problems T2 - Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems Y1 - 2003 SN - 3-00-010001-6 N1 - NIC Series VL - 15 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Staat, Manfred T1 - Problems and chances for probabilistic fracture mechanics in the analysis of steel pressure boundary reliability. - Überarb. Ausg. N2 - In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demon­strated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several addi­tional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings. KW - Bruchmechanik KW - probabilistic fracture mechanics KW - PFM Y1 - 2006 ER - TY - JOUR A1 - Kopp, Alexander A1 - Schmeets, Ralf A1 - Gosau, Martin A1 - Friedrich, Reinhard E. A1 - Fuest, Sandra A1 - Behbahani, Mehdi A1 - Barbeck, Mike A1 - Rutkowski, Rico A1 - Burg, Simon A1 - Kluwe, Lan A1 - Henningsen, Anders T1 - Production and Characterization of Porous Fibroin Scaffolds for Regenerative Medical Application JF - In Vivo Y1 - 2019 U6 - http://dx.doi.org/10.21873/invivo.11536 SN - 1791-7549 VL - 33 IS - 3 SP - 757 EP - 762 ER - TY - JOUR A1 - Jiminez German, Salvador A1 - Behbahani, Mehdi A1 - Miettinen, Susanna A1 - Grijpma, Dirk W. A1 - Haimi, Suvi P. T1 - Proliferation and differentiation of adipose stem cells towards smooth muscle cells on poly(trimethylene carbonate) membranes JF - Macromolecular symposia Y1 - 2013 SN - 0258-0322 VL - Vol. 334 IS - Iss. 1 SP - 133 EP - 142 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Seboldt, Wolfgang A1 - Blome, Hans-Joachim A1 - Dachwald, Bernd A1 - Richter, Lutz T1 - Proposal for an integrated European space exploration strategy T2 - 55th International Astronautical Congress of the International Astronautical Federation, the International Academy of Astronautics, and the International Institute of Space Law N2 - Recently, in his vision for space exploration, US president Bush announced to extend human presence across the solar system, starting with a human return to the Moon as early as 2015 in preparation for human exploration of Mars and other destinations. In Europe, an exploration program, termed AURORA, was established by ESA in 2001 – funded on a voluntary basis by ESA member states – with a clear focus on Mars and the ultimate goal of landing humans on Mars around 2030 in international cooperation. In 2003, a Human Spaceflight Vision Group was appointed by ESA with the task to develop a vision for the role of human spaceflight during the next quarter of the century. The resulting vision focused on a European-led lunar exploration initiative as part of a multi-decade, international effort to strengthen European identity and economy. After a review of the situation in Europe concerning space exploration, the paper outlines an approach for a consistent positioning of exploration within the existing European space programs, identifies destinations, and develops corresponding scenarios for an integrated strategy, starting with robotic missions to the Moon, Mars, and near-Earth asteroids. The interests of the European planetary in-situ science community, which recently met at DLR Cologne, are considered. Potential robotic lunar missions comprise polar landings to search for frozen volatiles and a sample return. For Mars, the implementation of a modest robotic landing mission in 2009 to demonstrate the capability for landing and prepare more ambitious and complex missions is discussed. For near-Earth asteroid exploration, a low-cost in-situ technology demonstration mission could yield important results. All proposed scenarios offer excellent science and could therefore create synergies between ESA’s mandatory and optional programs in the area of planetary science and exploration. The paper intents to stimulate the European discussion on space exploration and reflects the personal view of the authors. Y1 - 2004 N1 - 55th International Astronautical Congress 2004 - Vancouver, Canada SP - 1 EP - 10 ER - TY - JOUR A1 - Blome, Hans-Joachim A1 - Seboldt, Wolfgang A1 - Dachwald, Bernd A1 - Richter, Lutz T1 - Proposal for an integrated European Space Exploration Study JF - Space Debris and Space Traffic Management Symposium 2004 : proceedings of the International Academy of Astronautics Space Debris and Space Traffic Management Symposium, held in conjunction with the 55th International Astronautical Congress (IAC), October 4 - 8, 2004, Vancouver, British Columbia, Canada / ed. by Joerg Bendisch Y1 - 2004 SN - 0-87703-523-7 N1 - Proceedings IAC-2004-IAA, 3.6.1.06; Space Debris and Space Traffic Management Symposium <2004, Vancouver, British Columbia> ; International Academy of Astronautics PB - Univelt CY - San Diego, Calif. ER - TY - CHAP A1 - Savitskaya, Irina S. A1 - Kistaubayeva, Aida S. A1 - Akimbekov, Nuraly A1 - Digel, Ilya A1 - Shokatayeva, Dina A1 - Zhubanova, Azhar Achmet T1 - Prospective Use of Probiotics Immobilized on Sorbents with Nanostructured Surfaces T2 - Carbon Nanomaterials in Biomedicine and the Environment N2 - Activated carbons are known as excellent adsorbents. Their applications include the adsorptive removal of color, odor, taste, undesirable organic and inorganic pollutants from drinking and waste water; air purification in inhabited spaces; purification of many chemicals, pharmaceutical products and many others. This chapter elucidates the role of normal microflora in the maintenance of human health and presents materials on possible clinical displays of microecological infringements and ways of their correction. It presents new developments concerning new probiotics with immobilized Lactobacillus and Bacillus. The chapter considers the mechanisms of the intestine disbacteriosis correction by sorbed probiotics. It demonstrates the advantages and creation prospects of immobilized probiotics developed on the basis of carbonized rice husk. There are great prospects for the development of medical biotechnology due to use of carbon sorbents with a nanostructured surface. Microbial communities form a biocenosis of the biotope and together with the host organism create permanent or temporary ecosystems. Y1 - 2020 SN - 978-981-4800-27-3 U6 - http://dx.doi.org/10.1201/9780429428647-12 SP - 229 EP - 267 PB - Jenny Stanford Publishing CY - Singapore ER - TY - JOUR A1 - Digel, Ilya A1 - Zerlin, Kay A1 - Temiz Artmann, Aysegül A1 - Engels, S. T1 - Protein dynamics in thermosensation JF - Regenerative medicine. 2 (2007), H. 5 Y1 - 2007 SN - 1746-0751 N1 - Proceedings of the 3rd World Congress on Regenerative Medicine. October 18-20, 2007. Leipzig, Germany SP - 533 EP - 533 ER - TY - JOUR A1 - Hackl, Michael A1 - Müller, Lars-Peter A1 - Staat, Manfred A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian T1 - Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques JF - Knee surgery, sports traumatology, arthroscopy N2 - Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 148 EP - 149 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Baumann, Marcus A1 - Vilser, Walthard A1 - Lanzl, Ines M. T1 - Pulse wave velocity in retinal arteries of healthy volunteers JF - British Journal of Ophthalmology (eBJO) Y1 - 2011 SN - 1468-2079 VL - 95 IS - 11 SP - 675 EP - 679 PB - BMJ Publ. Group CY - London ER - TY - CHAP A1 - Iomdina, Elena N. A1 - Kiseleva, Anna A. A1 - Kotliar, Konstantin A1 - Luzhnov, Petr V. T1 - Quantification of Choroidal Blood Flow Using the OCT-A System Based on Voxel Scan Processing T2 - 2020 International Conference on Biomedical Innovations and Applications (BIA) Y1 - 2020 SN - 978-1-7281-7073-2 U6 - http://dx.doi.org/10.1109/BIA50171.2020.9244511 SP - 41 EP - 44 ER - TY - JOUR A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow JF - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4468-z SN - 1433-7347 VL - 25 IS - 7 SP - 2280 EP - 2288 PB - Springer CY - Berlin ER - TY - CHAP A1 - Dachwald, Bernd T1 - Radiation pressure force model for an ideal laser-enhanced solar sail T2 - 4th International Symposium on Solar Sailing N2 - The concept of a laser-enhanced solar sail is introduced and the radiation pressure force model for an ideal laser-enhanced solar sail is derived. A laser-enhanced solar sail is a “traditional” solar sail that is, however, not solely propelled by solar radiation, but additionally by a laser beam that illuminates the sail. The additional laser radiation pressure increases the sail's propulsive force and can give, depending on the location of the laser source, more control authority over the direction of the solar sail’s propulsive force vector. This way, laser-enhanced solar sails may augment already existing solar sail mission concepts and make novel mission concepts feasible. Y1 - 2017 N1 - 4th International Symposium on Solar Sailing 17-20 January 2017, Kyōto, Japan SP - 1 EP - 5 ER - TY - CHAP A1 - Zingsheim, Jonas A1 - Grimmer, Timo A1 - Ortner, Marion A1 - Schmaderer, Christoph A1 - Hauser, Christine A1 - Kotliar, Konstantin ED - Staat, Manfred ED - Erni, Daniel T1 - Recognition of subjects with mild cognitive impairment (MCI) by the use of retinal arterial vessels. T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 36 EP - 37 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Kurulgan demirci, Eylem A1 - Fırat, Ipek Seda A1 - Oflaz, Hakan A1 - Artmann, Gerhard T1 - Recombinant activated protein C (rhAPC) affects lipopolysaccharide-induced mechanical compliance changes and beat frequency of mESC-derived cardiomyocyte monolayers JF - SHOCK KW - Septic cardiomyopathy KW - LPS KW - cardiomyocyte biomechanics KW - CellDrum KW - actin cytoskeleton Y1 - 2021 U6 - http://dx.doi.org/10.1097/SHK.0000000000001845 SN - 1540-0514 PB - Wolters Kluwer CY - Köln ER -