TY - JOUR A1 - Müller-Veggian, Mattea A1 - Taras, P. A1 - Dehnhardt, W. A1 - Mills, S. J. T1 - Level properties in the even even nuclei ¹³⁰,¹³²,¹³⁴ Ce - further evidence for the back bending effect JF - Conférence européenne de physique nucléaire : Aix-en-Provence, 26 juin - 1. juillet 1972 ; comptes rendus des communication = European conference on nuclear physics / patronnée par La Société Française de Physique et La Société Européenne de Physique. Publ. avec le concours de Madeleine Porneuf Y1 - 1972 N1 - European Conference on Nuclear Physics <1972, Aix-en-Provence> ; Société Française de Physique ; European Physical Society ; Journal de physique Suppl.: Colloque ; 1972,C5 = [33],8/9,Suppl. SP - 102 CY - [Paris] ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Taras, P. A1 - Dehnhardt, W. A1 - Mills, S. J. T1 - High spin yrast states in ¹³² Ce JF - Physics letters B N2 - Yrast states up to spin 18 have been identified in ¹³²Ce. The energies and spins of the levels suggest the existence of two fairly well-behaved collective bands. The results are compared with those obtained in the rare-earth deformed region. Y1 - 1972 SN - 0031-9163 U6 - https://doi.org/10.1016/0370-2693(72)90582-5 N1 - 2. ISSN: 0370-2693 VL - 41 IS - 3 SP - 295 EP - 297 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Taras, P. A1 - Ward, D. A1 - Andrews, H. E. T1 - Etats "Yrast" a spin eleve dans les isotopes ¹³⁰,¹³²,¹³⁴ Ce JF - Rapport d'activité / Laboratoire de Physique Nucléaire. 9 (1974) Y1 - 1974 N1 - Laboratoire de Physique Nucléaire SP - 44 ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Turek, M. A1 - Colautti, P. T1 - The new Twin mini TEPC: an advanced tool for Boron Neutron Capture Therapy JF - Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 2004 (2005) Y1 - 2005 SN - 88-7337-008-X N1 - LNL-INFN(REP)-204/2005 SP - 244 EP - 245 ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Zuber, K. A1 - Gueven, H. T1 - In-beam study of ¹⁴³ Eu JF - Annual report 1987 / Kernforschungsanlage Jülich Institut für Kernphysik / Grümmer , F. (Hrsg.) . - (Spezielle Berichte der Kernforschungsanlage Jülich ; 442) Y1 - 1988 SP - 44 PB - Verlag des Forschungszentrums Jülich CY - Jülich ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Zuber, K. A1 - Gueven, H. T1 - In-beam study of 63 143 Eu 80 JF - Zeitschrift für Physik / A, Hadrons and nuclei. 330 (1988), H. 3 Y1 - 1988 SN - 1431-5831 N1 - 2. ISSN: 0340-2193 ; 3. ISSN 0930-1151 ; 4. ISSN 0939-7922 SP - 343 EP - 344 ER - TY - RPRT A1 - Nagl, Manfred A1 - Kraft, Bodo T1 - Graphbasierte Werkzeuge zur Unterstützung des konzeptuellen Gebäude-Entwurfs : Bericht über den 2. Förderzeitraum des Schwerpunktprogramms : DFG-Schwerpunktprogramm 1103 : Vernetzt-kooperative Planungsprozesse im Konstruktiven Ingenieurbau. - Auch unter dem Titel: Neue Software-Werkzeuge zur Unterstützung des konzeptuellen Gebäudeentwurfs N2 - Der konstruktive Entwurf wird in derzeitigen CAD-Systemen gut unterstützt, nicht aber der konzeptuelle Gebäude-Entwurf. Dieser abstrahiert von konstruktiven Elementen wie Linie, Wand oder Decke, um auf die Konzepte, d.h. die eigentlichen Funktionen, heraus zu arbeiten. Diese abstraktere, funktionale Sichtweise auf ein Gebäude ist während der frühen Entwurfsphase essentiell, um Struktur und Organisation des gesamten Gebäudes zu erfassen. Bereits in dieser Phase muss Fachwissen (z. B. rechtliche, ökonomische und technische Bestimmungen) berücksichtigt werden. Im Rahmen des vorliegenden Projekts werden Software-Werkzeuge integriert in industrielle CAD-Systeme entwickelt, die den konzeptuellen Gebäude-Entwurf ermöglichen und diesen gegen Fachwissen prüfen. Das Projekt ist in zwei Teile gegliedert. Im Top-Down-Ansatz werden Datenstrukturen und Methoden zur Strukturierung, Repräsentation und Evaluation von gebäudespezifischem Fachwissen erarbeitet. Dieser Teil baut auf den graphbasierten Werkzeugen PROGRES und UPGRADE des Lehrstuhls auf. Der Bottom-Up-Ansatz ist industriell orientiert und hat zum Ziel, das kommerzielle CAD-System ArchiCAD zu erweitern. Hierbei soll der frühe, konzeptuelle Gebäude-Entwurf in einem CAD-System ermöglicht werden. Der Entwurf kann darüber hinaus gegen das definierte Fachwissen geprüft werden. Im Rahmen des graphbasierten Top-Down-Ansatzes wurde zunächst eine neue Spezifikationsmethode für die Sprache PROGRES entwickelt. Das PROGRES-System erlaubt die Spezifikation von Werkzeugen in deklarativer Form. Üblicherweise wird domänenspezifisches Fachwissen in der PROGRES-Spezifikation codiert, das daraus generierte visuelle Werkzeug stellt dann die entsprechende Funktionalität zur Verfügung. Mit dieser Methode sind am Lehrstuhl für Informatik III Werkzeuge für verschie-dene Anwendungsdomänen entstanden. In unserem Fall versetzen wir einen Domänen-Experten, z. B. einen erfahrenen Architekten, in die Lage, Fachwissen zur Laufzeit einzugeben, dieses zu evaluieren, abzuändern oder zu ergänzen. Im Rahmen der bisherigen Arbeit wurde dazu eine parametrisierte PROGRES-Spezifikation und zwei darauf aufbauende Werkzeuge entwickelt, welche die dynamische Eingabe von gebäude-technisch relevantem Fachwissen erlauben und einen graphbasierten, konzeptuellen Gebäude-Entwurf ermöglichen. In diesem konzeptuellen Gebäude-Entwurf wird von Raumgrößen und Positionen abstrahiert, um die funktionale Struktur eines Gebäudes zu beschreiben. Das Fachwissen kann von einem Architekten visuell definiert werden. Es können semantische Einheiten, im einfachsten Fall Räume, nach verschiedenen Kriterien kategorisiert und klassifiziert werden. Mit Hilfe von Attributen und Relationen können die semantischen Einheiten präziser beschrieben und in Beziehung zueinander gesetzt werden. Die in PROGRES spezifizierten Konsistenz-Analysen erlauben die Prüfung eines graphbasierten konzeptuellen Gebäude-Entwurfs gegen das dynamisch eingefügte Fachwissen. Im zweiten Teil des Forschungsprojekts, dem Bottom-Up-Ansatz, wird das CAD-System ArchiCAD erweitert, um den integrierten konzeptuellen Gebäude-Entwurf zu ermöglichen. Der Architekt erhält dazu neue Entwurfselemente, die Raumobjekte, welche die relevanten semantischen Einheiten während der frühen Entwurfsphase repräsentieren. Mit Hilfe der Raumobjekte kann der Architekt in ArchiCAD den Grundriss und das Raumprogramm eines Gebäudes entwerfen, ohne von konstruktiven Details in seiner Kreativität eingeschränkt zu werden. Die Arbeitsweise mit Raumobjekten entspricht dem informellen konzeptuellen Entwurf auf einer Papierskizze und ist daher für den Architekten intuitiv und einfach zu verwenden. Durch die Integration in ArchiCAD ergibt sich eine weitere Unterstützung: Das im Top-Down-Ansatz spezifizierte Fach-wissen wird verwendet, um den konzeptuellen Gebäude-Entwurf des Architekten auf Regelverletzungen zu überprüfen. Entwurfsfehler werden angezeigt. Zum Abschluss des konzeptuellen Gebäude-Entwurfs mit Raumobjekten wird durch ein weiteres neu entwickeltes Werkzeug eine initiale Wandstruktur automatisch erzeugt, die als Grundlage für die folgenden konstruktiven Entwurfsphasen dient. Alle beschriebenen Erwei-terungen sind in ArchiCAD integriert, sie sind für den Architekten daher leicht zu erlernen und einfach zu bedienen. KW - CAD KW - CAD KW - Bauingenieurwesen KW - CAD KW - civil engineering Y1 - 2004 ER - TY - JOUR A1 - Nam, J. A1 - Arora, D. A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Benkowski, R. A1 - Behr, M. A1 - Pasquali, M. T1 - New computational method in hemolysis analysis for artificial heart pump Y1 - 2010 N1 - Posterpresentation ; American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 ER - TY - JOUR A1 - Neumaier, Felix A1 - Kotliar, Konstantin A1 - Haeren, Roel Hubert Louis A1 - Temel, Yasin A1 - Lüke, Jan Niklas A1 - Seyam, Osama A1 - Lindauer, Ute A1 - Clusmann, Hans A1 - Hescheler, Jürgen A1 - Schubert, Gerrit Alexander A1 - Schneider, Toni A1 - Albanna, Walid T1 - Retinal Vessel Responses to Flicker Stimulation Are Impaired in Ca v 2.3-Deficient Mice—An in- vivo Evaluation Using Retinal Vessel Analysis (RVA) JF - Frontiers in Neurology Y1 - 2021 U6 - https://doi.org/10.3389/fneur.2021.659890 VL - 12 SP - 1 EP - 11 PB - Frontiers ER - TY - JOUR A1 - Neumaier, Felix A1 - Weiss, Miriam A1 - Veldeman, Michael A1 - Kotliar, Konstantin A1 - Wiesmann, Martin A1 - Schulze-Steinen, Henna A1 - Höllig, Anke A1 - Clusmann, Hans A1 - Schubert, Gerrit Alexander A1 - Albanna, Walid T1 - Changes in endogenous daytime melatonin levels after aneurysmal subarachnoid hemorrhage – preliminary findings from an observational cohort study JF - Clinical Neurology and Neurosurgery N2 - Aneurysmal subarachnoid hemorrhage (aSAH) is associated with early and delayed brain injury due to several underlying and interrelated processes, which include inflammation, oxidative stress, endothelial, and neuronal apoptosis. Treatment with melatonin, a cytoprotective neurohormone with anti-inflammatory, anti-oxidant and anti-apoptotic effects, has been shown to attenuate early brain injury (EBI) and to prevent delayed cerebral vasospasm in experimental aSAH models. Less is known about the role of endogenous melatonin for aSAH outcome and how its production is altered by the pathophysiological cascades initiated during EBI. In the present observational study, we analyzed changes in melatonin levels during the first three weeks after aSAH. KW - constructive alignment KW - examination KW - long-term retention KW - multimodal KW - practical learning Y1 - 2021 U6 - https://doi.org/10.1016/j.clineuro.2021.106870 SN - 0303-8467 VL - 208 IS - Article No.: 106870 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ngamga, Eulalie Joelle A1 - Bialonski, Stephan A1 - Marwan, Norbert A1 - Kurths, Jürgen A1 - Geier, Christian A1 - Lehnertz, Klaus T1 - Evaluation of selected recurrence measures in discriminating pre-ictal and inter-ictal periods from epileptic EEG data JF - Physics Letters A N2 - We investigate the suitability of selected measures of complexity based on recurrence quantification analysis and recurrence networks for an identification of pre-seizure states in multi-day, multi-channel, invasive electroencephalographic recordings from five epilepsy patients. We employ several statistical techniques to avoid spurious findings due to various influencing factors and due to multiple comparisons and observe precursory structures in three patients. Our findings indicate a high congruence among measures in identifying seizure precursors and emphasize the current notion of seizure generation in large-scale epileptic networks. A final judgment of the suitability for field studies, however, requires evaluation on a larger database. Y1 - 2016 U6 - https://doi.org/10.1016/j.physleta.2016.02.024 SN - 0375-9601 VL - 380 IS - 16 SP - 1419 EP - 1425 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 12 ER - TY - JOUR A1 - Nguyen, Nhu Huynh A1 - Duong, Minh Tuan A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Grottke, O. A1 - Tolba, R. A1 - Staat, Manfred T1 - Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs JF - Journal of Biomechanics N2 - The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines. KW - Autolysis KW - Decomposition KW - Freeze–thaw process KW - Spleen KW - Liver Y1 - 2012 U6 - https://doi.org/10.1016/j.jbiomech.2012.07.008 SN - 1873-2380 VL - 45 IS - 14 SP - 2382 EP - 2386 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nguyen-Xuan, H. A1 - Rabczuk, T. A1 - Nguyen-Thoi, T. A1 - Tran, Thanh Ngoc A1 - Nguyen-Thanh, N. T1 - Computation of limit and shakedown loads using a node-based smoothed finite element method JF - International Journal for Numerical Methods in Engineering N2 - This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods. Y1 - 2011 U6 - https://doi.org/10.1002/nme.3317 SN - 1097-0207 VL - 90 IS - 3 SP - 287 EP - 310 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Nomdedeu, Mar Monsonis A1 - Willen, Christine A1 - Schieffer, Andre A1 - Arndt, Hartmut T1 - Temperature-dependent ranges of coexistence in a model of a two-prey-one-predator microbial food web JF - Marine Biology N2 - The objective of our study was to analyze the effects of temperature on the population dynamics of a three-species food web consisting of two prey bacteria (Pedobacter sp. and Acinetobacter johnsonii) and a protozoan predator (Tetrahymena pyriformis) as model organisms. We assessed the effects of temperature on the growth rates of all three species with the objective of developing a model with four differential equations based on the experimental data. The following hypotheses were tested at a theoretical level: Firstly, temperature changes can affect the dynamic behavior of a system by temperature-dependent parameters and interactions and secondly, food web response to temperature cannot be derived from the single species temperature response. The main outcome of the study is that temperature changes affect the parameter range where coexistence is possible within all three species. This has significant consequences on our ideas regarding the evaluation of effects of global warming. Y1 - 2012 U6 - https://doi.org/10.1007/s00227-012-1966-x SN - 1432-1793 VL - 159 IS - 11 SP - 2423 EP - 2430 PB - Springer CY - Berlin ER - TY - JOUR A1 - Novacek, V. A1 - Tran, Thanh Ngoc A1 - Klinge, U. A1 - Tolba, R. H. A1 - Staat, Manfred A1 - Bronson, D. G. A1 - Miesse, A. M. A1 - Whiffen, J. A1 - Turquier, F. T1 - Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design JF - Journal of Biomechanics N2 - The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge. KW - Variable height stapler design KW - Anastomotic leakage KW - Finite element modelling KW - End-to-end colorectal anastomosis KW - Surgical staplers Y1 - 2012 U6 - https://doi.org/10.1016/j.jbiomech.2012.07.021 SN - 1873-2380 VL - 45 IS - 115 SP - 2693 EP - 2697 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nurispahic, A. A1 - Kotliar, Konstantin A1 - Lanzl, I. T1 - Messung der Akkommodation mittels optischer Biometrie JF - Der Ophthalmologe Y1 - 2008 SN - 1433-0423 VL - 105 IS - 4 SP - 369 EP - 375 PB - - ER - TY - JOUR A1 - Näther, Niko A1 - Auger, V. A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - A miniaturized flow-through cell in SU-8 technique for EIS sensors JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 994 EP - 995 ER - TY - JOUR A1 - Näther, Niko A1 - Berger, Jörg A1 - Emmerich, Rüdiger A1 - Friedrich, P. A1 - Henkel, H. A1 - Schöning, Michael Josef T1 - H2O2-Konzentrationsbestimmung für die Prozessgasanalytik mittels eines kalorimetrischen Sensoraufbaus JF - Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. März 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2008 SN - 978-3-18-092011-5 N1 - VDI-Berichte ; 2011 ; Sensoren und Messsysteme 2008, 14. GMA/ITG-Fachtagung, VDI/VDE- Gesellschaft Mess- und Automatisierungstechnik, + CD-ROM, Ludwigsburg, DE, 11.-12. Mar, 2008 SP - 783 EP - 792 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Näther, Niko A1 - Berger, Jörg A1 - Emmerich, Rüdiger A1 - Friedrich, Peter A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schöning, Michael Josef T1 - Entwicklung einer kalorimetrischen H2O2-Gassensoranordnung für die Prozessgaskontrolle JF - 8. Dresdner Sensor-Symposium : Sensoren für Umwelt, Klima und Sicherheit, Biosensoren und Biosysteme, Sensoren und Sensorsysteme für die Prozesstechnik, Trends in der Sensortechnik, Materialentwicklung für die Sensorik; 8. Dresdner Sensor-Symposium, 10. - 12. Dezember 2007, Dresden / Gerald Gerlach ... (Hg.) Y1 - 2007 SN - 978-3-940046-45-1 N1 - Dresdner Beiträge zur Sensorik ; 29 SP - 261 EP - 264 PB - TUDpress, Verl. der Wissenschaften CY - Dresden ER - TY - JOUR A1 - Näther, Niko A1 - Emmerich, Rüdiger A1 - Berger, Jörg A1 - Friedrich, Peter A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schöning, Michael Josef T1 - A novel gas-phase hydrogen peroxide sensor basing on a combined physical/chemical transduction mechanism JF - Nanofunctional materials, nanostructures, and novel devices for biological and chemical detection : November 27 - December 1, 2006, Boston, Massachusetts, USA ; [at the 2006 MRS Fall Meeting]. Y1 - 2006 SN - 978-1-60423-407-7 N1 - Materials Research Society symposium proceedings ; 951 ; MRS fall meeting ; (2006.11.27-12.01 : ; Boston, Mass.) SP - 63 EP - 68 PB - Materials Research Soc. CY - Warrendale, Pa. ER - TY - JOUR A1 - Näther, Niko A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schöning, Michael Josef T1 - Investigation of different catalytically active and passive materials for realising a hydrogen peroxide gas sensor JF - physica status solidi (a) . 206 (2009), H. 3 Y1 - 2009 SN - 1862-6319 N1 - Special Issue: Engineering of Functional Interfaces (EnFI 08) SP - 449 EP - 454 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Näther, Niko A1 - Juárez, Leon M. A1 - Emmerich, Rüdiger A1 - Berger, Jörg A1 - Friedrich, Peter A1 - Schöning, Michael Josef T1 - Detection of hydrogen peroxide (H2O2) at exposed temperatures for industrial processes N2 - An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM. KW - Biosensor KW - Gas sensor KW - hydrogen peroxide KW - sterilisation KW - catalytic decomposition Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1418 ER - TY - CHAP A1 - Näther, Niko A1 - Poghossian, Arshak A1 - Platen, J. A1 - Yoshinobu, T. A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing of both physical and (bio-)chemical quantities using the same transducer principle T2 - Biochemical sensing utilisation of micro- and nanotechnologies : Warsaw, [23rd - 26th] November 2005 / ed. by M. Mascini ... Y1 - 2006 SP - 172 EP - 181 CY - Warsaw ER - TY - JOUR A1 - Näther, Niko A1 - Rolka, David A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Two microcell flow-injection analysis (FIA) platforms for capacitive silicon-based field-effect sensors JF - Electrochimica Acta. 51 (2005), H. 5 Y1 - 2005 SN - 0013-4686 U6 - https://doi.org/10.1016/j.electacta.2005.04.066 SP - 924 EP - 929 ER - TY - CHAP A1 - O\'Heras, Carlos A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - Nanostructured carbon-based column for LPS/protein adsorption : [abstract] N2 - The absence of a general method for endotoxin removal from liquid interfaces gives an opportunity to find new methods and materials to overcome this gap. Activated nanostructured carbon is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study is to find the adsorption rates for a carboneous material produced at different temperatures, as well as to reveal possible differences between the performance of the material for each of the adsorbates used during the study (hemoglobin, serum albumin and lipopolysaccharide, LPS). KW - Kohlenstofffaser KW - Adsorption KW - Lipopolysaccharide KW - aktivierte nanostrukturierte Kohlenstofffaser KW - lipopolysaccharides KW - activated nanostructured carbon Y1 - 2009 ER - TY - CHAP A1 - Oberländer, Jan A1 - Arreola, Julio A1 - Hansen, Christina A1 - Greeff, Anton A1 - Mayer, Marlena A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Impedimetric Biosensor to Enable Fast Evaluation of Gaseous Sterilization Processes T2 - MDPI Proceedings Y1 - 2017 U6 - https://doi.org/10.3390/proceedings1040435 N1 - Eurosensors 2017 Conference, Paris, France, 3–6 September 2017 VL - 1 IS - 4 ER - TY - JOUR A1 - Oberländer, Jan A1 - Bromm, Alexander A1 - Wendeler, Luisa A1 - Iken, Heiko A1 - Palomar Duran, Marlena A1 - Greeff, Anton A1 - Kirchner, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a biosensor to monitor the sterilisation efficiency of aseptic filling machines JF - Physica status solidi (a) N2 - Sterilisation processes are compulsory in medicine, pharmacy, and food industries to prevent infections of consumers and microbiological contaminations of products. Monitoring the sterilisation by conventional microbiological methods is time- and lab-consuming. To overcome this problem, in this work a novel biosensor has been proposed. The sensor enables a fast method to evaluate sterilisation processes. By means of thin-film technology the sensor's transducer structures in form of IDEs (interdigitated electrodes) have been fabricated on a silicon substrate. Physical characterisation of the developed sensor was done by AFM, SEM, and profilometry. Impedance analyses were conducted for the electrical characterisation. As microbiological layer spores of B. atrophaeus have been immobilised on the sensing structure; spores of this type are a well-known sterilisation test organism. Impedance measurements at a fixed frequency over time were performed to monitor the immobilisation process. A sterilisation process according to aseptic filling machines was applied to demonstrate the sensor functionality. After both, immobilisation and sterilisation, a change in impedance could successfully be detected. Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431900 SN - 1862-6319 VL - 212 IS - 6 SP - 1299 EP - 1305 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Oberländer, Jan A1 - Jildeh, Zaid B. A1 - Kirchner, Patrick A1 - Wendeler, Luisa A1 - Bromm, Alexander A1 - Iken, Heiko A1 - Wagner, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Study of Interdigitated Electrode Arrays Using Experiments and Finite Element Models for the Evaluation of Sterilization Processes JF - Sensors N2 - In this work, a sensor to evaluate sterilization processes with hydrogen peroxide vapor has been characterized. Experimental, analytical and numerical methods were applied to evaluate and study the sensor behavior. The sensor set-up is based on planar interdigitated electrodes. The interdigitated electrode structure consists of 614 electrode fingers spanning over a total sensing area of 20 mm2. Sensor measurements were conducted with and without microbiological spores as well as after an industrial sterilization protocol. The measurements were verified using an analytical expression based on a first-order elliptical integral. A model based on the finite element method with periodic boundary conditions in two dimensions was developed and utilized to validate the experimental findings. Y1 - 2015 U6 - https://doi.org/10.3390/s151026115 SN - 1424-8220 N1 - This article belongs to the Special Issue "Gas Sensors—Designs and Applications" VL - 15 IS - 10 SP - 26115 EP - 26127 PB - MDPI CY - Basel ER - TY - CHAP A1 - Oberländer, Jan A1 - Jildeh, Zaid B. A1 - Kirchner, Patrick A1 - Wendeler, Luisa A1 - Bromm, Alexander A1 - Iken, Heiko A1 - Wagner, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Experimental and numerical evaluation of interdigitated electrode array for monitoring gaseous sterilization processes T2 - 12. Dresdner Sensor-Symposium 2015 Y1 - 2015 U6 - https://doi.org/10.5162/12dss2015/P3.11 SP - 163 EP - 168 ER - TY - JOUR A1 - Oberländer, Jan A1 - Kirchner, Patrick A1 - Boyen, Hans-Gerd A1 - Schöning, Michael Josef T1 - Detection of hydrogen peroxide vapor by use of manganese(IV) oxide as catalyst for calorimetric gas sensors JF - Physica status solidi A: Applications and materials science N2 - In this work, the catalyst manganese(IV) oxide (MnO2), of calorimetric gas sensors (to monitor the sterilization agent vaporized hydrogen peroxide) has been investigated in more detail. Chemical analyses by means of X-ray-induced photoelectron spectroscopy have been performed to unravel the surface chemistry prior and after exposure to hydrogen peroxide vapor at elevated temperature, as applied in the sterilization processes of beverage cartons. The surface characterization reveals a change in oxidation states of the metal oxide catalyst after exposure to hydrogen peroxide. Additionally, a cleaning effect of the catalyst, which itself is attached to the sensor surface by means of a polymer interlayer, could be observed. Y1 - 2014 U6 - https://doi.org/10.1002/pssa.201330359 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1372 EP - 1376 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Oberländer, Jan A1 - Kirchner, Patrick A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Flexible polyimide-based calorimetric gas sensors for monitoring hy-drogen peroxide in sterilisation processes of aseptic filling machines T2 - Sensoren und Messsysteme 2014 ; Beiträge der 17. GMA/ITG-Fachtagung vom 3. bis 4. Juni 2014 in Nürnberg. (ITG-Fachbericht ; 250) Y1 - 2014 SN - 978-3-8007-3622-5 SP - 1 EP - 4 PB - VDE-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Oberländer, Jan A1 - Kirchner, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Strategies in developing thin-film sensors for monitoring aseptic food processes : Theoretical considerations and investigations of passivation materials JF - Electrochimica Acta N2 - The sterilization of packages in aseptic food processes is highly significant to maintain a consumer-safe product with extended shelf-life. Today, the sterilization of food packages is predominantly accomplished by gaseous hydrogen peroxide (H2O2) in combination with heat. In order to monitor this sterilization process, calorimetric gas sensors as differential set-up of two platinum temperature sensors representing a catalytically active (additionally deposition of MnO2) and a passive segment have been recently developed. The temperature rise of the exothermic decomposition serves as an indicator of the present H2O2 concentration. In the present work, a theoretical approach considering the sensor’s thermochemistry and physical transport phenomena was formulated to evaluate the temperature rise based on the energy content of gaseous H2O2. In a further part of this work, three polymers have been analyzed with respect to their application as passivation materials. The examined polymers are photoresist SU-8, perfluoroalkoxy (PFA) and fluorinated ethylene propylene (FEP). Thermal analyses by means of differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) have been conducted to determine the operation limits of the polymers. The overall chemical resistance and stability of the polymers against the harsh environmental conditions during the sterilization process have been examined by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR). Y1 - 2015 U6 - https://doi.org/10.1016/j.electacta.2015.06.126 SN - 0013-4686 VL - 183 SP - 130 EP - 136 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Oberländer, Jan A1 - Mayer, Marlena A1 - Greeff, Anton A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Spore-based biosensor to monitor the microbicidal efficacy of gaseous hydrogen peroxide sterilization processes JF - Biosensors and Bioelectronics N2 - In this work, a spore-based biosensor is evaluated to monitor the microbicidal efficacy of sterilization processes applying gaseous hydrogen peroxide (H2O2). The sensor is based on interdigitated electrode structures (IDEs) that have been fabricated by means of thin-film technologies. Impedimetric measurements are applied to study the effect of sterilization process on spores of Bacillus atrophaeus. This resilient microorganism is commonly used in industry to proof the sterilization efficiency. The sensor measurements are accompanied by conventional microbiological challenge tests, as well as morphological characterizations with scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The sensor measurements are correlated with the microbiological test routines. In both methods, namely the sensor-based and microbiological one, a tailing effect has been observed. The results are evaluated and discussed in a three-dimensional calibration plot demonstrating the sensor's suitability to enable a rapid process decision in terms of a successfully performed sterilization. Y1 - 2018 U6 - https://doi.org/10.1016/j.bios.2017.12.045 SN - 0956-5663 VL - 104 SP - 87 EP - 94 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Oberländer, Jan A1 - Reisert, Steffen A1 - Kirchner, Patrick A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Kalorimetrische Gassensoren zur H2O2-Detektion in aseptischen Sterilisationsprozessen T2 - 11. Dresdner Sensor-Symposium : 9.-11.12.2013 Y1 - 2013 SN - 978-3-9813484-5-3 SP - 234 EP - 238 ER - TY - THES A1 - Oflaz, Hakan T1 - Entwicklung eines Prototypen zur Prognose von Frühgeburten : ein biomedizintechnischer Ansatz Y1 - 2012 U6 - https://doi.org/10.4126/38m-004639208 N1 - Köln, Univ., Diss., 2012 PB - Deutsche Zentralbibliothek für Medizin CY - Köln ER - TY - CHAP A1 - Olderog, M. A1 - Mohr, P. A1 - Beging, Stefan A1 - Tsoumpas, C. A1 - Ziemons, Karl T1 - Simulation study on the role of tissue-scattered events in improving sensitivity for a compact time of flight compton positron emission tomograph T2 - 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) N2 - In positron emission tomography improving time, energy and spatial detector resolutions and using Compton kinematics introduces the possibility to reconstruct a radioactivity distribution image from scatter coincidences, thereby enhancing image quality. The number of single scattered coincidences alone is in the same order of magnitude as true coincidences. In this work, a compact Compton camera module based on monolithic scintillation material is investigated as a detector ring module. The detector interactions are simulated with Monte Carlo package GATE. The scattering angle inside the tissue is derived from the energy of the scattered photon, which results in a set of possible scattering trajectories or broken line of response. The Compton kinematics collimation reduces the number of solutions. Additionally, the time of flight information helps localize the position of the annihilation. One of the questions of this investigation is related to how the energy, spatial and temporal resolutions help confine the possible annihilation volume. A comparison of currently technically feasible detector resolutions (under laboratory conditions) demonstrates the influence on this annihilation volume and shows that energy and coincidence time resolution have a significant impact. An enhancement of the latter from 400 ps to 100 ps leads to a smaller annihilation volume of around 50%, while a change of the energy resolution in the absorber layer from 12% to 4.5% results in a reduction of 60%. The inclusion of single tissue-scattered data has the potential to increase the sensitivity of a scanner by a factor of 2 to 3 times. The concept can be further optimized and extended for multiple scatter coincidences and subsequently validated by a reconstruction algorithm. Y1 - 2021 SN - 978-1-7281-7693-2 U6 - https://doi.org/10.1109/NSS/MIC42677.2020.9507901 N1 - 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 31 Oct.-7 Nov. 2020, Boston, MA, USA PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Oliveira, Danilo A. A1 - Molinnus, Denise A1 - Beging, Stefan A1 - Siqueira Jr, José R. A1 - Schöning, Michael Josef T1 - Biosensor Based on Self-Assembled Films of Graphene Oxide and Polyaniline Using a Field-Effect Device Platform JF - physica status solidi (a) applications and materials science N2 - A new functionalization method to modify capacitive electrolyte–insulator–semiconductor (EIS) structures with nanofilms is presented. Layers of polyallylamine hydrochloride (PAH) and graphene oxide (GO) with the compound polyaniline:poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (PANI:PAAMPSA) are deposited onto a p-Si/SiO2 chip using the layer-by-layer technique (LbL). Two different enzymes (urease and penicillinase) are separately immobilized on top of a five-bilayer stack of the PAH:GO/PANI:PAAMPSA-modified EIS chip, forming a biosensor for detection of urea and penicillin, respectively. Electrochemical characterization is performed by constant capacitance (ConCap) measurements, and the film morphology is characterized by atomic force microscopy (AFM) and scanning electron microscopy (SEM). An increase in the average sensitivity of the modified biosensors (EIS–nanofilm–enzyme) of around 15% is found in relation to sensors, only carrying the enzyme but without the nanofilm (EIS–enzyme). In this sense, the nanofilm acts as a stable bioreceptor onto the EIS chip improving the output signal in terms of sensitivity and stability. KW - capacitive electrolyte–insulator–semiconductor sensors KW - graphene oxide KW - layer-by-layer technique KW - nanomaterials KW - polyaniline Y1 - 2021 U6 - https://doi.org/10.1002/pssa.202000747 SN - 1862-6319 N1 - Corresponding author: José R. Siqueira Jr & Michael J. Schöning VL - 218 IS - 13 SP - 1 EP - 9 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Osterhage, Hannes A1 - Bialonski, Stephan A1 - Staniek, Matthäus A1 - Schindler, Kaspar A1 - Wagner, Tobias A1 - Elger, Christian E. A1 - Lehnertz, Klaus T1 - Bivariate and multivariate time series analysis techniques and their potential impact for seizure prediction T2 - Seizure Prediction in Epilepsy: From Basic Mechanisms to Clinical Applications Y1 - 2008 SN - 978-3-527-62519-2 U6 - https://doi.org/10.1002/9783527625192.ch15 SP - 189 EP - 208 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Paczkowski, Sebastian A1 - Weißbecker, Bernhard A1 - Schöning, Michael Josef A1 - Schütz, Stefan T1 - Biosensors on the Basis of Insect Olfaction JF - Insect biotechnology / Andreas Vilcinskas, ed. Y1 - 2011 SN - 978-90-481-9640-1 N1 - Biologically-inspired system ; 2 SP - 225 EP - 240 PB - Springer CY - Dordrecht [u.a.] ER - TY - PAT A1 - Papaspyrou, Manfred A1 - Born, Christoph A1 - Biselli, Manfred A1 - Schröder, Bernd T1 - Verfahren zur Bestimmung von Pharmakokinetik bzw. Toxikokinetik von Testsubstanzen mit Hilfe von in-vitro-Zellkultursystemen und dafür geeignete Vorrichtungen [Offenlegungsschrift] Y1 - 1996 N1 - DE000019537033A1 22.08.1996 EP000000727480A2 21.08.1996 SP - 1 EP - 10 ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER - TY - BOOK A1 - Pawelke, Siegfried T1 - Saturation und Approximation bei Reihen mehrdimensionaler Kugelfunktionen Y1 - 1969 PB - Techn. Hochsch. CY - Aachen ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Ein Satz von Jacksonschen Typ für algebraischen Polynome JF - Acta scientiarum mathematicarum / Bolyai Institute, University of Szeged Y1 - 1972 SN - 0001-6969 IS - 33 SP - 323 EP - 336 PB - n.a. CY - Szeged ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Über die Approximationsordnung bei Kugelfunktionen und algebraischen Polynomen JF - Tohoku Mathematical Journal (2) N2 - Für die Approximation stetiger, 2π-periodischer Funktionen auf der reellen Achse durch trigonometrische Polynome wurde ein direkter Satz von D. Jackson 1911 [8] und die Umkehrung von S. N. Bernstein 1912 [1] bewiesen und die Ergebnisse von A. Zygmund [25] 1945 verallgemeinert. 1949 stellte M. Zamansky [25] eine Beziehung zwischen der Approximationsordnung und dem Wachstum bezϋglich n der Ableitungen der Approximationspolynome her; auf die Approximationsordnung für die Ableitungen der Funktion schloβ S. B. Steckin 1951. Die Umkehrung des Ergebnisses von M. Zamansky bewies G. Sunouchi 1968 [21,22], womit die Aquivalenz aller Aussagen gezeigt ist. Die Übertragung der Ergebnisse auf Approximationsoperatoren in Banachräumen stammt von K. Scherer und P. L. Butzer [3, 4], wobei gewisse Voraussetzungen an die Operatorfolge (eine verallgemeinerte Bernsteinsche Ungleichung und eine sogenannte Jacksonsche Ungleichung) gestellt werden. An die Stelle der strukturellen Eigenschaften der Funktion, die durch das Verhalten des Stetigkeitsmoduls der Funktion charakterisiert werden, treten in allgemeinen Banachräumen Eigenschaften des von J. Peetre [17] eingefϋhrten K-Funktionals. In dieser Arbeit wird die Approximation von Funktionen, die auf der Einheitskugel Sᵏ im Rᵏ definiert sind, durch Linearkombinationen von Kugelfunktionen untersucht. Es wird für diesen Fall eine Bernstein-Ungleichung und die Jackson-Ungleichung bewiesen, wenn man die Ableitung durch den Laplace-Operator auf Sᵏ ersetzt. Damit ist der oben zitierte allgemeine Satz von Butzer-Scherer anwendbar. Weiter kann man hier an Stelle des K-Funktionals einen verallgemeinerten Stetigkeitsmodul setzen. Anschlieβend wird der Spezialfall der zonalen Funktionen und ihre Approximation durch algebraische Polynome untersucht. Y1 - 1972 SN - 0040-8735 U6 - https://doi.org/10.2748/tmj/1178241489 VL - 24 IS - 3 SP - 473 EP - 486 PB - Tohoku University CY - Sendai ER - TY - CHAP A1 - Pawelke, Siegfried ED - Ciesielski, Zbigniew T1 - Approximationstheorie mit Hilfe von Jacobi-Polynomen und Kugelfunktionen T2 - Proceedings of the conference jointly organized by the Mathematical Institute of the Polish Academy of Sciences and the Institute of Mathematics of the Adam Mickiewicz University, held in Poznan, 22-26 August, 1972 Y1 - 1975 SN - 90-277-0483-X SP - 157 EP - 173 PB - Reichel CY - Dordrecht ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Weak smoothness conditions for the uniform convergence of Fourier-Jacobi series JF - Functiones et Approximatio. Commentarii Mathematici. 9 (1980) Y1 - 1980 SN - 0208-6573 N1 - Zentralblatt MATH: http://www.emis.de/MATH-item?0471.42018 SP - 9 EP - 13 ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Note on Jackson and Bernstein type approximation theorems in the case of approximation by algebraic polynomial in the spaces L and C JF - Studia Scientiarum Mathematicarum Hungarica. 36 (2000), H. 3-4 Y1 - 2000 SN - 0081-6906 SP - 353 EP - 358 ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Berens, H. A1 - Butzer, Paul L. T1 - Limitierungsverfahren von Reihen mehrdimensionaler Kugelfunktionen und deren Saturationsverhalten JF - Publications of the Research Institute for Mathematical Sciences, Series A N2 - Die vorliegende Arbeit untersucht das approximationstheoretische Verhalten von Summationsprozessen von Reihen von Kugelfunktionen, sogenannten Laplace-Reihen. Zunächst wird die Theorie der besten Approximation auf der Kugel, also die Erweiterung der Sätze von D. Jackson und S. Bernstein, skizziert. Nimmt man nun spezielle Verfahren zur Summation von Laplace-Reihen, dann lassen sich auch hier Sätze vom Jacksonschen und Bernsteinschen Typ beweisen. Darüber hinaus zeigen viele Verfahren ein Saturationsverhalten, d.h. es gibt eine nur vom Verfahren abhängige optimale Approximationsordnung. Das Saturationsproblem besteht nun darin, diejenige Klasse von Funktionen (Saturationsklasse) zu bestimmen, welche genau von der optimalen Ordnung approximiert werden. Y1 - 1968 U6 - https://doi.org/10.2977/prims/1195194875 SN - 0034-5318 VL - 4 IS - 2 SP - 201 EP - 268 PB - EMS Press CY - Zürich ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Butzer, Paul L. T1 - Ableitungen von trigonometrischen Approximationsprozessen JF - Acta scientiarum mathematicarum / Institutum Bolyaianum Universitatis Szegediensis Y1 - 1967 SN - 0001-6969 VL - 28 IS - 1-2 SP - 173 EP - 183 PB - n.a. CY - Szeged ER -