TY - JOUR A1 - Grottke, O. A1 - Braunschweig, T. A1 - Philippen, B. A1 - Gatzweiler, Karl-Heinz A1 - Gronloh, N. A1 - Staat, Manfred A1 - Rossaint, R. A1 - Tolba, R. T1 - A New Model for Blunt Liver Injuries in the Swine JF - European Surgical Research. 44 (2010), H. 2 Y1 - 2010 SN - 1421-9921 SP - 65 EP - 73 ER - TY - JOUR A1 - Grundlach, Michael A1 - Baumann, Martin A1 - Engelmann, Ulrich M. ED - Dössel, Olaf T1 - How Multimodal Examinations Can Increase Sustainable Student Gain by Aligning Teaching and Assessment JF - Current Directions in Biomedical Engineering N2 - Modern industry and multi-discipline projects require highly trained individuals with resilient science and engineering back-grounds. Graduates must be able to agilely apply excellent theoretical knowledge in their subject matter as well as essential practical “hands-on” knowledge of diverse working processes to solve complex problems. To meet these demands, university education follows the concept of Constructive Alignment and thus increasingly adopts the teaching of necessary practical skills to the actual industry requirements and assessment routines. However, a systematic approach to coherently align these three central teaching demands is strangely absent from current university curricula. We demonstrate the feasibility of implementing practical assessments in a regular theory-based examination, thus defining the term “blended assessment”. We assessed a course for natural science and engineering students pursuing a career in biomedical engineering, and evaluated the benefit of blended assessment exams for students and lecturers. Our controlled study assessed the physiological background of electrocardiograms (ECGs), the practical measurement of ECG curves, and their interpretation of basic pathologic alterations. To study on long time effects, students have been assessed on the topic twice with a time lag of 6 months. Our findings suggest a significant improvement in student gain with respect to practical skills and theoretical knowledge. The results of the reassessments support these outcomes. From the lecturers ́ point of view, blended assessment complements practical training courses while keeping organizational effort manageable. We consider blended assessment a viable tool for providing an improved student gain, industry-ready education format that should be evaluated and established further to prepare university graduates optimally for their future careers. KW - constructive alignment KW - examination KW - long-term retention KW - multimodal KW - practical learning Y1 - 2021 SN - 2364-5504 U6 - http://dx.doi.org/10.1515/cdbme-2021-2019 VL - 7 IS - 7/2 SP - 73 EP - 76 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Grüters, Hugo T1 - Ein Hinweis auf parametererregte Wankschwingungen von Kraftfahrzeugen JF - Automobil-Industrie Y1 - 1975 SN - 0005-1306 VL - 20 IS - 4 SP - 65 EP - 67 PB - Vogel CY - Würzburg ER - TY - BOOK A1 - Grüters, Hugo T1 - Mechanik: Vorlesung Y1 - 1987 PB - Becker-Kuns CY - Aachen ER - TY - JOUR A1 - Grüters, Hugo T1 - Biomechanisch begründete Stimulation postoperativer Knochenumbauvorgänge JF - Biomedizinische Technik . 37 (1992), H. 5 Y1 - 1992 SN - 0013-5585 SP - 94 EP - 98 ER - TY - BOOK A1 - Grüters, Hugo T1 - Berechnung des Spannungszustandes in homogenen anisotropen Scheiben mit Hilfe einer Integralgleichungsmethode Y1 - 1971 N1 - Aachen, Techn. Hochsch., Diss., 1971 ER - TY - JOUR A1 - Grüters, Hugo T1 - Isotrope, homogene Lösung des anisotropen, inhomogenen Plattenproblems JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM Y1 - 1975 U6 - http://dx.doi.org/10.1002/zamm.19750550405 SN - 0044-2267 VL - 55 IS - 4 (Special Issue) SP - T91 EP - T93 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Grüters, Hugo T1 - Iterative Lösung von Lastspannungsproblemen in anisotropen Körpern JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM Y1 - 1974 SN - 0044-2267 U6 - http://dx.doi.org/10.1002/zamm.19740541230 VL - 54 IS - 12 SP - T79 EP - T80 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Grüters, Hugo T1 - Berechnung des Spannungszustandes in homogenen Scheiben aus anisotrop-elastischem Material JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM Y1 - 1972 SN - 0044-2267 U6 - http://dx.doi.org/10.1002/zamm.19720521105 VL - 52 IS - 11 SP - T127 EP - T128 PB - Wiley-VCH CY - Weinheim ER - TY - BOOK A1 - Grüters, Hugo T1 - Aufgabensammlung Mechanik / von Hugo Grüters Y1 - 1987 N1 - [circa 1987] PB - Becker-Kuns CY - Aachen ER - TY - JOUR A1 - Grüters, Hugo T1 - Eigenspannungen und Verkrümmungen von Balken aus Hartschaum JF - Automobil-Industrie. 24 (1979), H. 3 Y1 - 1979 SN - 0005-1306 SP - 115 EP - 123 ER - TY - JOUR A1 - Grüters, Hugo T1 - Ein thermoelastisches Modell zur Prognose postoperativer Knochenumbaubildungen JF - Vorträge der 26. Jahrestagung der Deutschen Gesellschaft für Biomedizinische Technik e.V. Oktober 1992 Y1 - 1992 N1 - Vorträge der ... Jahrestagung der Deutschen Gesellschaft für Biomedizinische Technik e.V. ; 26 SP - 7 EP - 8 ER - TY - JOUR A1 - Grüters, Hugo A1 - Blank, K. T1 - Contribution to the size effect on the strength of flat glass. Blank, K.; Grüters, H. JF - Glastechnische Berichte. 63 (1990), H. 5 Y1 - 1990 SN - 0017-1085 SP - 135 EP - 140 ER - TY - JOUR A1 - Grüters, Hugo A1 - Blank, K. A1 - Dürkop, D. A1 - Durchholz, M. T1 - Strength tests of flat glass by means of four-point bending. Blank, K.; Dürkop, D.; Durchholz, M.; Grüters, H. JF - Glastechnische Berichte. Glass science and technology. 67 (1994), H. 1 Y1 - 1994 SN - 0946-7475 SP - 9 EP - 15 ER - TY - JOUR A1 - Grüters, Hugo A1 - Gitschner, H.-W. T1 - Diffusionsbedingte Eigenspannungen (Quellspannungen) und Deformationszustände in anisotropen glasfaserverstärkten Mehrschichten-Verbundwerkstoffen. Gitschner, H.-W.; Grüters, H. JF - Kunststoffe. 71 (1981), H. 3 Y1 - 1981 SN - 0023-5563 SP - 178 EP - 183 ER - TY - JOUR A1 - Grüters, Hugo A1 - Hackl, K. A1 - Willms, H. T1 - Stress and strain analyses of rectangular glass plates for large deformations. Part 1. Dimensioning of rectangular plates under surface load and/or line load. JF - Glastechnische Berichte. 63 (1990), H. 3 Y1 - 1990 SN - 0017-1085 SP - 69 EP - 77 ER - TY - JOUR A1 - Grüters, Hugo A1 - Hackl, K. A1 - Willms, H. T1 - Stress and strain analyses of rectangular glass plates for large deformations. Part 2. Calculation of fracture probabilities in rectangular plates under area load JF - Glastechnische Berichte. 63 (1990), H. 4 Y1 - 1990 SN - 0017-1085 SP - 93 EP - 95 ER - TY - JOUR A1 - Grüters, Hugo A1 - Hiemenz, C. T1 - Berechnung des Verzugs und der Schwindung von PUR-Strukturschaumplatten JF - Kunststoffe. 70 (1980), H. 4 Y1 - 1980 SN - 0023-5563 SP - 228 EP - 233 ER - TY - JOUR A1 - Grüters, Hugo A1 - Hiemenz, C. T1 - Berechnung des Verzugs und der Schwindung von Profilen aus PUR-Strukturschaumstoff. Kriterien zur Herstellung von verzugsfreien Profilen JF - Kunststoffe. 70 (1980), H. 2 Y1 - 1980 SN - 0023-5563 SP - 102 EP - 107 ER - TY - JOUR A1 - Grüters, Hugo A1 - Müller, C. H. T1 - Anwendung der Cosseratschen Kontinuumstheorie auf den ebenen Verbundkörper JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM. 61 (1981) Y1 - 1981 SN - 0044-2267 SP - T92 EP - T94 ER - TY - JOUR A1 - Grüters, Hugo A1 - Müller, C. H. T1 - Experimentell-rechnerische Ermittlung von Eigenspannungen JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM = Journal of applied mathematics and mechanics. 59 (1979) Y1 - 1979 SN - 0044-2267 SP - T184 EP - T186 ER - TY - JOUR A1 - Grüters, Hugo A1 - Müller, C. H. A1 - Willms, H. T1 - Ein Beitrag zur Berechnung von Gusseigenspannungen in Rohren JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM = Journal of applied mathematics and mechanics. 63 (1983) Y1 - 1983 SN - 0044-2267 SP - T160 EP - T163 ER - TY - JOUR A1 - Grüters, Hugo A1 - Müller, Carl Harald T1 - Zur Berechnung der Schubspannungen in Klebverbindungen JF - Automobil-Industrie. 25 (1980), H. 2 Y1 - 1980 SN - 0005-1306 SP - 65 EP - 67 ER - TY - BOOK A1 - Grüters, Hugo A1 - Peters, Norbert T1 - Mechanik. Bd. 2 Dynamik. Peters, Norbert; Grüters, Hugo Y1 - 1984 PB - Inst. für Techn. Mechanik, RWTH Aachen CY - Aachen ER - TY - BOOK A1 - Grüters, Hugo A1 - Peters, Norbert T1 - Mechanik. Bd. 1 Statik, Festigkeitslehre / N. Peters, H. Grüters Y1 - 1982 PB - Inst. für Techn. Mechanik, RWTH Aachen CY - Aachen ER - TY - JOUR A1 - Grüters, Hugo A1 - Savvidis, E. A1 - Löer, F. A1 - Wiesener, C. H. T1 - Analyse der Beanspruchung des proximalen Femur bei verschiedenen Arten der Belastung mit Hilfe der Finite-Element-Methode / Savvidis, E. ; Löer, F. ; Grüters, Hugo ; Wiesener, C. H. JF - Zeitschrift für Orthopädie und ihre Grenzgebiete. 129 (1991), H. 3 Y1 - 1991 SN - 1615-9586 SP - 268 EP - 277 ER - TY - JOUR A1 - Grüters, Hugo A1 - Senger, W. T1 - Simulation des biomechanisch durch Energiedehnung stimulierten Knochenumbaus JF - Biomedizinische Technik. 57 (1992), H. Ergänzungsband 1 Y1 - 1992 SN - 0013-5585 SP - 39 EP - 41 ER - TY - JOUR A1 - Gun, Jenny A1 - Gutkin, Vitaly A1 - Lev, Ovadia A1 - Boyen, Hans-Gerd A1 - Saitner, Marc A1 - Wagner, Patrick A1 - Olieslaeger, Marc D´ A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Tracing gold nanoparticle charge by electrolyte-insulator-semiconductor devices JF - Journal of Physical Chemistry C. 115 (2011), H. 11 Y1 - 2011 SN - 1932-7455 SP - 4439 EP - 4445 PB - American Cemical Society CY - Washington, DC ER - TY - JOUR A1 - Gun, Jenny A1 - Rizkov, Dan A1 - Lev, Ovadia A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Oxygen plasma-treated gold nanoparticle-based field-effect devices as transducer structures for bio-chemical sensing JF - Microchimica Acta. 164 (2008), H. 3-4 Y1 - 2008 SN - 1436-5073 SP - 395 EP - 404 ER - TY - JOUR A1 - Gun, Jenny A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Katz, Evgeny T1 - Field-Effect Nanoparticle-Based Glucose Sensor on a Chip: Amplification Effect of Coimmobilized Redox Species JF - Electroanalysis. 20 (2008), H. 16 Y1 - 2008 SN - 1521-4109 SP - 1748 EP - 1753 ER - TY - JOUR A1 - Guo, Yuanyuan A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Device simulation of the light-addressable potentiometric sensor for the investigation of the spatial resolution JF - Sensors and actuators B: Chemical N2 - As a semiconductor-based electrochemical sensor, the light-addressable potentiometric sensor (LAPS) can realize two dimensional visualization of (bio-)chemical reactions at the sensor surface addressed by localized illumination. Thanks to this imaging capability, various applications in biochemical and biomedical fields are expected, for which the spatial resolution is critically significant. In this study, therefore, the spatial resolution of the LAPS was investigated in detail based on the device simulation. By calculating the spatiotemporal change of the distributions of electrons and holes inside the semiconductor layer in response to a modulated illumination, the photocurrent response as well as the spatial resolution was obtained as a function of various parameters such as the thickness of the Si substrate, the doping concentration, the wavelength and the intensity of illumination. The simulation results verified that both thinning the semiconductor substrate and increasing the doping concentration could improve the spatial resolution, which were in good agreement with known experimental results and theoretical analysis. More importantly, new findings of interests were also obtained. As for the dependence on the wavelength of illumination, it was found that the known dependence was not always the case. When the Si substrate was thick, a longer wavelength resulted in a higher spatial resolution which was known by experiments. When the Si substrate was thin, however, a longer wavelength of light resulted in a lower spatial resolution. This finding was explained as an effect of raised concentration of carriers, which reduced the thickness of the space charge region. The device simulation was found to be helpful to understand the relationship between the spatial resolution and device parameters, to understand the physics behind it, and to optimize the device structure and measurement conditions for realizing higher performance of chemical imaging systems. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.snb.2014.08.016 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 204 SP - 659 EP - 665 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Guo, Yuanyuan A1 - Seki, Kosuke A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Novel photoexcitation method for light-addressable potentiometric sensor with higher spatial resolution JF - Applied physics express : APEX N2 - A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) is proposed to achieve a higher spatial resolution of chemical images. The proposed method employs a combined light source that consists of a modulated light probe, which generates the alternating photocurrent signal, and a ring of constant illumination surrounding it. The constant illumination generates a sheath of carriers with increased concentration which suppresses the spread of photocarriers by enhanced recombination. A device simulation was carried out to verify the effect of constant illumination on the spatial resolution, which demonstrated that a higher spatial resolution can be obtained. Y1 - 2014 U6 - http://dx.doi.org/10.7567/APEX.7.067301 SN - 1882-0786 (E-Journa); 1882-0778 (Print) VL - 7 IS - 6 SP - 067301-4 PB - IOP CY - Bristol ER - TY - JOUR A1 - Guo, Yuanyuan A1 - Seki, Kosuke A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Device simulation of the light-addressable potentiometric sensor with a novel photoexcitation method for a higher spatial resolution JF - Procedia Engineering N2 - A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) realized a higher spatial resolution of chemical imaging. In this method, a modulated light probe, which generates the alternating photocurrent signal, is surrounded by a ring of constant light, which suppresses the lateral diffusion of photocarriers by enhancing recombination. A device simulation verified that a higher spatial resolution could be obtained by adjusting the gap between the modulated and constant light. It was also found that a higher intensity and a longer wavelength of constant light was more effective. However, there exists a tradeoff between the spatial resolution and the amplitude of the photocurrent, and thus, the signal-to-noise ratio. A tilted incidence of constant light was applied, which could achieve even higher resolution with a smaller loss of photocurrent. KW - Light-addressable Potentiometric Sensor KW - novel photoexcitation method KW - tilted constant illumination KW - spatial resolution Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.proeng.2014.11.369 SN - 1877-7058 N1 - EUROSENSORS 2014 ; European Conference on Solid-State Transducers <28, 2014> VL - 87 SP - 456 EP - 459 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Gutheil, Inge A1 - Berg, Tommy A1 - Grotendorst, Johannes T1 - Performance Analysis of Parallel Eigensolvers of two Libraries on BlueGene/P JF - Journal of Mathematics and Systems Science N2 - Many applications in computational science and engineering require the computation of eigenvalues and vectors of dense symmetric or Hermitian matrices. For example, in DFT (density functional theory) calculations on modern supercomputers 10% to 30% of the eigenvalues and eigenvectors of huge dense matrices have to be calculated. Therefore, performance and parallel scaling of the used eigensolvers is of upmost interest. In this article different routines of the linear algebra packages ScaLAPACK and Elemental for parallel solution of the symmetric eigenvalue problem are compared concerning their performance on the BlueGene/P supercomputer. Parameters for performance optimization are adjusted for the different data distribution methods used in the two libraries. It is found that for all test cases the new library Elemental which uses a two-dimensional element by element distribution of the matrices to the processors shows better performance than the old ScaLAPACK library which uses a block-cyclic distribution. KW - performance analysis KW - Elemental KW - ScaLAPACK KW - eigensolvers KW - Numerical linear algebra Y1 - 2012 U6 - http://dx.doi.org/10.17265/2159-5291/2012.04.003 SN - 2159-5291 VL - 2 IS - 4 SP - 231 EP - 236 PB - David Publishing CY - Libertyville ER - TY - JOUR A1 - Göddeke, Dominik A1 - Strzodka, Robert A1 - Mohd-Yusof, Jamaludin A1 - McCormick, Patrick A1 - Buijssen, Sven H.M. A1 - Grajewski, Matthias A1 - Turek, Stefan T1 - Exploring weak scalability for FEM calculations on a GPU-enhanced cluster JF - Parallel Computing Y1 - 2007 U6 - http://dx.doi.org/10.1016/j.parco.2007.09.002 SN - 0167-8191 VL - 33 IS - 10-11 SP - 685 EP - 699 ER - TY - RPRT A1 - Göll, Fabian A1 - Braunstein, Björn A1 - Albracht, Kirsten T1 - Lernende roboterassistierte Systeme für das neuromuskuläre Training - RoSylerNT; Teilvorhaben: Entwicklung eines neuromuskuloskelettalen Modells als Basis für die Interaktionsfähigkeiten autonomer Assistenzsysteme KW - Robotik KW - Rehabilitationsmedizin KW - Neuromuskuläres System KW - Rehabilitatives Training KW - Trainingsgerät Y1 - 2021 U6 - http://dx.doi.org/10.2314/KXP:1855318741 N1 - Förderkennzeichen BMBF 16SV7853 Schlussbericht der Deutschen Sporthochschule Köln für das Vorhaben RoSylerNT Laufzeit: 01.08.2017-31.07.2021 PB - Deutsche Sporthochschule Köln CY - Köln ER - TY - JOUR A1 - Hacker, Tobias A1 - Kraft, Bodo A1 - Zöll, Axel T1 - Projektzuschnitt für die inkrementelle Systementwicklung im Konzernverbund Y1 - 2011 SN - 978-3-8322-9990-3 N1 - Zusammenspiel von Vorgehensmodellen und Organisationsformen, Workshop der Fachgruppe WI-VM der Gesellschaft für Informatik, 18 SP - 78 EP - 83 ER - TY - JOUR A1 - Hackl, M. A1 - Andermahr, J. A1 - Staat, Manfred A1 - Bremer, I. A1 - Borggrefe, J. A1 - Prescher, A. A1 - Müller, L. P. A1 - Wegmann, K. T1 - Suture button reconstruction of the central band of the interosseous membrane in Essex-Lopresti lesions: a comparative biomechanical investigation JF - The Journal of Hand Surgery (European Volume) Y1 - 2017 U6 - http://dx.doi.org/10.1177/1753193416665943 SN - 2043-6289 (Online) SN - 1753-1934 (Print) VL - 42 IS - 4 SP - 370 EP - 376 PB - Sage CY - London ER - TY - JOUR A1 - Hackl, Michael A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian A1 - Ries, Christian A1 - Staat, Manfred A1 - Müller, Lars-Peter T1 - Shortening osteotomy of the proximal radius — a treatment option for isolated osteoarthritis of the lateral column of the elbow joint? JF - Knee surgery, sports traumatology, arthroscopy N2 - Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue. While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 128 EP - 129 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Leschinger, T. A1 - Staat, Manfred A1 - Müller, Lars-Peter A1 - Wegmann, Kilian T1 - Reconstruction of the interosseous membrane in the Essex Lopresti lesion — a biomechanical evaluation JF - Knee surgery, sports traumatology, arthroscopy N2 - Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 130 EP - 131 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Müller, Lars-Peter A1 - Staat, Manfred A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian T1 - Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques JF - Knee surgery, sports traumatology, arthroscopy N2 - Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 148 EP - 149 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Nacov, Julia A1 - Kammerlohr, Sandra A1 - Staat, Manfred A1 - Buess, Eduard A1 - Leschinger, Tim A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Intratendinous Strain Variations of the Supraspinatus Tendon Depending on Repair Technique: A Biomechanical Analysis Regarding the Cause of Medial Cuff Failure JF - The American Journal of Sports Medicine Y1 - 2021 U6 - http://dx.doi.org/10.1177/03635465211006138 SN - 1552-3365 SN - 0363-5465 VL - 49 IS - 7 SP - 1847 EP - 1853 PB - Sage CY - London ER - TY - JOUR A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow JF - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4468-z SN - 1433-7347 VL - 25 IS - 7 SP - 2280 EP - 2288 PB - Springer CY - Berlin ER - TY - GEN A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Reply to the letter to the editor: shortening osteotomy of the proximal radius T2 - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4666-8 VL - 25 IS - 10 SP - 3328 EP - 3329 ER - TY - JOUR A1 - Hafner, David A1 - Demetz, Oliver A1 - Weickert, Joachim A1 - Reißel, Martin T1 - Mathematical Foundations and Generalisations of the Census Transform for Robust Optic Flow Computation JF - Journal of Mathematical Imaging and Vision Y1 - 2014 U6 - http://dx.doi.org/10.1007/s10851-014-0529-9 SN - 1573-7683 (Online) N1 - Springer Online First (ohne Seitenang. und Heftzuteilung) PB - Springer CY - New York ER - TY - CHAP A1 - Hafner, David A1 - Ochs, Peter A1 - Weickert, Joachim A1 - Reißel, Martin ED - Rosenhahn, Bodo T1 - FSI Schemes : Fast Semi-Iterative Solvers for PDEs and Optimisation Methods T2 - Pattern Recognition : 38th German Conference, GCPR 2016, Hannover, Germany, September 12-15, 2016, Proceedings Y1 - 2016 SN - 978-3-319-45886-1 U6 - http://dx.doi.org/10.1007/978-3-319-45886-1_8 N1 - Lecture Notes in Computer Science; Vol. 9796 SP - 91 EP - 102 PB - Springer ER - TY - JOUR A1 - Hamad, E. M. A1 - Bilatto, S. E. R. A1 - Adly, N. Y. A1 - Correa, D. S. A1 - Wolfrum, B. A1 - Schöning, Michael Josef A1 - Offenhäusser, A. A1 - Yakushenko, A. T1 - Inkjet printing of UV-curable adhesive and dielectric inks for microfluidic devices JF - Lab on a Chip N2 - Bonding of polymer-based microfluidics to polymer substrates still poses a challenge for Lab-On-a-Chip applications. Especially, when sensing elements are incorporated, patterned deposition of adhesives with curing at ambient conditions is required. Here, we demonstrate a fabrication method for fully printed microfluidic systems with sensing elements using inkjet and stereolithographic 3D-printing. Y1 - 2016 U6 - http://dx.doi.org/10.1039/C5LC01195G SN - 1473-0189 VL - 16 IS - 1 SP - 70 EP - 74 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Hamou, Hussam Aldin A1 - Kotliar, Konstantin A1 - Tan, Sonny Kian A1 - Weiß, Christel A1 - Blume, Christian A1 - Clusmann, Hans A1 - Schubert, Gerrit Alexander A1 - Albanna, Walid T1 - Surgical nuances and placement of subgaleal drains for supratentorial procedures—a prospective analysis of efficacy and outcome in 150 craniotomies JF - Acta Neurochirurgica N2 - Background For supratentorial craniotomy, surgical access, and closure technique, including placement of subgaleal drains, may vary considerably. The influence of surgical nuances on postoperative complications such as cerebrospinal fluid leakage or impaired wound healing overall remains largely unclear. With this study, we are reporting our experiences and the impact of our clinical routines on outcome in a prospectively collected data set. Method We prospectively observed 150 consecutive patients undergoing supratentorial craniotomy and recorded technical variables (type/length of incision, size of craniotomy, technique of dural and skin closure, type of dressing, and placement of subgaleal drains). Outcome variables (subgaleal hematoma/CSF collection, periorbital edema, impairment of wound healing, infection, and need for operative revision) were recorded at time of discharge and at late follow-up. Results Early subgaleal fluid collection was observed in 36.7% (2.8% at the late follow-up), and impaired wound healing was recorded in 3.3% of all cases, with an overall need for operative revision of 6.7%. Neither usage of dural sealants, lack of watertight dural closure, and presence of subgaleal drains, nor type of skin closure or dressing influenced outcome. Curved incisions, larger craniotomy, and tumor size, however, were associated with an increase in early CSF or hematoma collection (p < 0.0001, p = 0.001, p < 0.01 resp.), and larger craniotomy size was associated with longer persistence of subgaleal fluid collections (p < 0.05). Conclusions Based on our setting, individual surgical nuances such as the type of dural closure and the use of subgaleal drains resulted in a comparable complication rate and outcome. Subgaleal fluid collections were frequently observed after supratentorial procedures, irrespective of the closing technique employed, and resolve spontaneously in the majority of cases without significant sequelae. Our results are limited due to the observational nature in our single-center study and need to be validated by supportive prospective randomized design. Y1 - 2020 U6 - http://dx.doi.org/10.1007/s00701-019-04196-6 SN - 0942-0940 VL - 2020 IS - 162 SP - 729 EP - 736 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Hanssen, H. A1 - Nickel, T. A1 - Drexel, V. A1 - Hertel, G. A1 - Emslander, I. A1 - Sisic, Z. A1 - Lorang, D. A1 - Schuster, T. A1 - Kotliar, Konstantin A1 - Pressler, A. A1 - Schmidt-Trucksäss, A. A1 - Weis, M. A1 - Halle, M. T1 - Exercise-induced alterations of retinal vessel diameters and cardiovascular risk reduction in obesity JF - Atherosclerosis Y1 - 2011 SN - 0021-9150 VL - 216 IS - 2 SP - 433 EP - 439 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hasan, Istabrak A1 - Keil, Ludger A1 - Staat, Manfred A1 - Wahl, Gerhard A1 - Bourauel, Christoph T1 - Determination of the frictional coefficient of the implant-antler interface : experimental approach JF - Biomedical Engineering / Biomedizinische Technik N2 - The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens. Y1 - 2012 SN - 1862-278X VL - 57 IS - 5 SP - 359 EP - 363 PB - De Gruyter CY - Berlin ER -