TY - GEN A1 - Abdelghani, Adnane A1 - Menaa, Bouzid A1 - Obare, Sherine O. A1 - Schöning, Michael Josef T1 - Special issue on nanoscale science and technology / guest eds.: Adnane Abdelghani, Bouzid Menaa, Sherine O. Obare, Michael J. Schöning T2 - International journal of nanotechnology Y1 - 2013 SN - 1741-8151 (E-Journal), 1475-7435 (Print) VL - Vol. 10 IS - No. 5-7 SP - 373 EP - 619 ER - TY - JOUR A1 - Aboulnaga, E. A. A1 - Zou, H. A1 - Selmer, Thorsten A1 - Xian, M. T1 - Development of a plasmid-based, tunable, tolC-derived expression system for application in Cupriavidus necator H16 JF - Journal of Biotechnology N2 - Cupriavidus necator H16 gains increasing attention in microbial research and biotechnological application due to its diverse metabolic features. Here we present a tightly controlled gene expression system for C. necator including the pBBR1-vector that contains hybrid promoters originating from C. necator native tolC-promoter in combination with a synthetic tetO-operator. The expression of the reporter gene from these plasmids relies on the addition of the exogenous inducer doxycycline (dc). The novel expression system offers a combination of advantageous features as; (i) high and dose-dependent recombinant protein production, (ii) tight control with a high dynamic range (On/Off ratio), which makes it applicable for harmful pathways or for toxic protein production, (iii) comparable cheap inducer (doxycycline, dc), (iv) effective at low inducer concentration, that makes it useful for large scale application, (v) rapid, diffusion controlled induction, and (vi) the inducer does not interfere within the cell metabolism. As applications of the expression system in C. necator H16, the growth ability on glycerol was enhanced by constitutively expressing the E. coli glpk gene-encoding for glycerol kinase. Likewise, we used the system to overcome the expression toxicity of mevalonate pathway in C. necator H16. With this system, the mevalonate-genes were successfully introduced in the host and the recombinant strains could produce about 200 mg/l mevalonate. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiotec.2018.03.007 SN - 0168-1656 VL - 274 SP - 15 EP - 27 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Ingebrandt, S. A1 - Poghossian, Arshak A1 - Zhang, Y. A1 - Moritz, W. A1 - Schöning, Michael Josef T1 - Field-effect nanoplate capacitive pH sensor based on SOI structure JF - Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009 Y1 - 2009 SP - 55 EP - 58 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Ingebrandt, S. A1 - Poghossian, Arshak A1 - Zhang, Y. A1 - Vu, X. T. A1 - Moritz, W. A1 - Schöning, Michael Josef T1 - Nanoplate field-effect capacitive (bio-)chemical sensor array based on SOI structure JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 670 EP - 673 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Pedraza, A. M. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Label-free DNA hybridization and denaturation detection by means of field-effect nanoplate SOI capacitors functionalized with gold nanoparticles JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Proc. Eurosensors XXIV, September 5–8, 2010, Linz, Austria SP - 918 EP - 921 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Cherstvy, Andrey G. A1 - Pedraza, Angela M. A1 - Ingebrandt, Sven A1 - Schöning, Michael Josef T1 - Label-free electrical detection of DNA by means of field-effect nanoplate capacitors: Experiments and modeling JF - Physica Status Solidi (a) N2 - Label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization/denaturation by means of an array of individually addressable field-effect-based nanoplate silicon-on-insulator (SOI) capacitors modified with gold nanoparticles (Au-NP) is investigated. The proposed device detects charge changes on Au-NP/DNA hybrids induced by the hybridization or denaturation event. DNA hybridization was performed in a high ionic-strength solution to provide a high hybridization efficiency. On the other hand, to reduce the screening of the DNA charge by counter ions and to achieve a high sensitivity, the sensor signal induced by the hybridization and denaturation events was measured in a low ionic-strength solution. High sensor signals of about 120, 90, and 80 mV were registered after the DNA hybridization, denaturation, and re-hybridization events, respectively. Fluorescence microscopy has been applied as reference method to verify the DNA immobilization, hybridization, and denaturation processes. An electrostatic charge-plane model for potential changes at the gate surface of a nanoplate field-effect sensor induced by the DNA hybridization has been developed taking into account both the Debye length and the distance of the DNA charge from the gate surface. Y1 - 2012 U6 - http://dx.doi.org/10.1002/pssa.201100710 SN - 1862-6319 VL - 209 SP - 925 EP - 934 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Pedraza, A. M. A1 - Gandhi, D. A1 - Ingebrandt, S. A1 - Moritz, W. A1 - Schöning, Michael Josef T1 - An array of field-effect nanoplate SOI capacitors for (bio-)chemical sensing JF - Biosensors and Bioelectronics. 26 (2011), H. 6 Y1 - 2011 SN - 0956-5663 SP - 3023 EP - 3028 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Razavi, A. A1 - Williams, O. A. A1 - Bijnens, N. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Characterisation of capacitive field-effect sensors with a nanocrystalline-diamond film as transducer material for multi-parameter sensing JF - Biosensors and Bioelectronics. 24 (2009), H. 5 Y1 - 2009 SN - 0956-5663 N1 - Selected Papers from the Tenth World Congress on Biosensors Shangai, China, May 14-16, 2008 ; Zeitschrift früher u.d.T. : Biosensors SP - 1298 EP - 1304 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Razavi, Arash A1 - Besmehn, Astrid A1 - Bijnens, Nathalie A1 - Williams, Oliver A. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Penicillin detection with nanocrystalline-diamond field-effect sensor JF - physica status solidi (a). 205 (2008), H. 9 Y1 - 2008 SN - 1862-6319 N1 - Special Issue: Hasselt Diamond Workshop 2008 - SBDD XIII SP - 2141 EP - 2145 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Siqueira, José R. Jr. A1 - Oliveira, Osvaldo N. Jr. A1 - Moritz, Werner A1 - Schöning, Michael Josef T1 - Capacitive electrolyte-insulator-semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: New strategy for enhanced field-effect biosensing JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 884 EP - 890 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Christiaens, P. A1 - Williams, O. A. A1 - Wagner, P. A1 - Haenen, K. T1 - Feldeffektsensor auf nanokristalliner Diamantbasis JF - Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. März 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2008 SN - 978-3-18-092011-5 N1 - VDI-Berichte ; 2011 ; Sensoren und Messsysteme 2008, 14. GMA/ITG-Fachtagung, VDI/VDE- Gesellschaft Mess- und Automatisierungstechnik, + CD-ROM, Ludwigsburg, DE, 11.-12. Mar, 2008 SP - 549 EP - 558 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Werner, Moritz A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Capacitance–voltage and impedance-spectroscopy characteristics of nanoplate EISOI capacitors JF - Physica status solidi (a) : applications and material science. 208 (2011), H. 6 Y1 - 2011 SN - 1862-6319 SP - 1327 EP - 1332 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Abulnaga, El-Hussiny A1 - Pinkenburg, Olaf A1 - Schiffels, Johannes A1 - E-Refai, Ahmed A1 - Buckel, Wolfgang A1 - Selmer, Thorsten T1 - Effect of an Oxygen-Tolerant Bifurcating Butyryl Coenzyme A Dehydrogenase/Electron-Transferring Flavoprotein Complex from Clostridium difficile on Butyrate Production in Escherichia coli JF - Journal of bacteriology Y1 - 2013 SN - 1098-5530 [E-Journal] SN - 0021-9193 [Print] VL - 195 IS - 16 SP - 3704 EP - 3713 ER - TY - THES A1 - Achtsnicht, Stefan T1 - Multiplex-Magnetdetektion von superparamagnetischen Beads zur Identifizierung von Trinkwasserkontaminationen N2 - Die qualitative und quantitative Detektion von Zielsubstanzen innerhalb einer wässrigen Probe ist für viele Fragestellungen von Interesse, etwa bei der Detektion von Kontaminationen in Trinkwasser in Krisensituationen. Hierbei ist es nicht nur wichtig, dass Pathogene möglichst sensitiv detektiert werden können, sondern auch, dass die Analyse schnell erfolgt, um Betroffenen im Katastrophenfall zügig sicheres Trinkwasser zu Verfügung stellen zu können. Da bei einem solchen Szenario nicht von einer in der Nähe befindlichen funktionierenden Laborinfrastruktur ausgegangen werden kann, ist es wichtig, dass die Messung direkt vor Ort erfolgen kann. Im Rahmen dieser Arbeit wurde untersucht, ob eine derartige Schnellanalytik mithilfe von superparamagnetischen Beads (MBs) und der magnetischen Frequenzmischtechnik möglich ist. Dabei werden die MBs mit Hilfe von primären Antikörpern an die Zielsubstanz gebunden und mit sekundären Antikörpern an die Poren-Oberfläche eines Polyethylen-Filters fixiert (Sandwich-Immunoassay). So kann die Quantifizierung der Zielsubstanz auf eine magnetische Messung der immobilisierten MB-Marker zurückgeführt werden. Die magnetische Frequenzmischtechnik basiert auf der Anregung der Probe mit Magnetfeldern zweier verschiedener Frequenzen. Die durch die nichtlineare Magnetisierungsform der superparamagnetischen MBs entstehenden Mischfrequenzen werden typischerweise mithilfe einer zweistufigen Lock-in-Detektion analysiert (analoge Demodulation), die in einem Magnetreader als Handheldgerät realisiert wurde. Zusätzlich zu dieser Technik wurde das Prinzip der direkten Digitalisierung des gesamten Antwortsignals mit anschließender Fourier-Analyse der erzeugten Mischfrequenzen experimentell umgesetzt, um die Amplituden und Phasen mehrerer Mischfrequenzen simultan zu erfassen. Eine Möglichkeit zur Sensitivitätssteigerung ist die magnetische Aufkonzentration, indem vor der magnetischen Analyse eine Separation der MBs aus einem größeren Probenvolumen mittels magnetischem Feldgradienten durchgeführt wird. Zur Charakterisierung verschiedener kommerzieller MBs hinsichtlich ihrer magnetischen Separierbarkeit wurde ein Aufbau zur Messung ihrer magnetophoretischen Beweglichkeiten realisiert und ihre Geschwindigkeiten im Gradientenfeld mikroskopisch gemessen.Da eine Probe oftmals nicht nur auf eine einzige Zielsubstanz, sondern simultan auf mehrere verschiedene Pathogene hin untersucht werden soll, wurden verschiedene Ansätze entwickelt und getestet, die einen solchen multiparametrischen magnetischen Immunoassay ermöglichen. Einerseits wurde eine räumliche Separation der Bindungsbereiche für verschiedene Zielsubstanzen realisiert, die sequentiell ausgewertet werden können. Andererseits wurde die Unterscheidung von verschiedenen Zielsubstanzen anhand der Charakteristika der an sie gebundenen, verschieden funktionalisierten MB-Typen untersucht. Für eine solche Unterscheidung wurde zum einen die Anregefrequenz der magnetischen Frequenzmischtechnik während einer Messung variiert. Damit konnte gezeigt werden, dass sich verschiedene MB-Sorten anhand der Phase ihrer Frequenzmischsignale voneinander unterscheiden lassen. Weiterhin wurde gezeigt, dass sich der Signalverlauf einer binären Mischung zweier verschiedener MB-Typen als gradueller Übergang der Verläufe der beiden reinen MB-Lösungen ergibt. Eine weitere Analysemethode für einen multiparametrischen Immunoassay besteht darin, ein zusätzliches einstellbares statisches magnetisches Offsetfeld zu verwenden. Hierfür wurden mehrere Aufbauten auf Basis von Permanent- und Elektromagneten simuliert, konstruiert und charakterisiert. Mithilfe von Simulationen konnte gezeigt werden, dass eine auf diesem Verfahren beruhende Unterscheidung für MBs mit unterschiedlichen magnetischen Partikelmomenten möglich ist. Als direkte Anwendung des hier entwickelten Magnetreaders in Zusammenspiel mit der digitalen Demodulation wurde ein magnetischer Assay gegen die B-Untereinheit des Choleratoxins in Trinkwasser mit einem niedrigen Detektionslimit von 0,2 ng/ml demonstriert. N2 - The qualitative and quantitative detection of target substances in an aqueous sample is of interest for many questions, for example in the detection of contaminations in drinking water in crisis situations. It is not only important that pathogens can be detected with highest possible sensitivity, but also that the analysis is carried out quickly so that safe drinking water can be provided in the event of a disaster. During such a scenario one cannot rely on a functioning laboratory infrastructure nearby. Therefore it is important that the measurement can be carried out directly on site. Within the scope of this work, it was investigated whether such a quick analysis can be performed using superparamagnetic beads (MBs) and the magnetic frequency mixing technique. The MBs are bound to the target substance with the aid of primary antibodies and fixed to the pore surfaces of a polyethylene filter with secondary antibodies (sandwich immunoassay). The quantification of the target substance can thus be traced back to a magnetic measurement of the immobilized MB markers. The magnetic frequency mixing technique is based on the excitation of the sample with magnetic fields of two different frequencies. The mixing frequencies generated due to the non-linear shape of the magnetization of the superparamagnetic MBs are typically analyzed using a two-stage Lock-in detection (analog demodulation), which was implemented in a magnetic reader as a handheld device. In addition to this technique, the principle of direct digitization of the entire response signal with subsequent Fourier analysis of the generated mixing frequencies was experimentally implemented in order to simultaneously record the amplitudes and phases of several mixing frequencies. One possibility for increasing the sensitivity is magnetic concentration. In that case, the MBs are separated from a larger sample volume by means of a magnetic field gradient before the magnetic analysis. To characterize various commercial MBs with regard to their magnetic separability, a setup for measuring their magnetophoretic mobility was implemented and their velocities in the gradient field were measured with an optical microscope.Often, a sample has to be examined not only for a single target substance, but for several different pathogens simultaneously. Various approaches have been developed and tested which enable such a multiparametric magnetic immunoassay. On the one hand, a spatial separation of the binding areas for different target substances was realized, which can be evaluated sequentially. On the other hand, a distinction among different target substances based on the magnetic characteristics of their attached different MB types was examined. For this discrimination, the excitation frequency of the magnetic frequency mixing technology was varied during measurement. It is shown that different MB types can be distinguished from one another based on the phase of their frequency mixing signals. The signal curve of a binary mixture of two different MB types is obtained as a gradual transition of the curves of the two pure MB solutions. Another method of analysis for a multiparametric immunoassay is based on an additional adjustable static magnetic offset field. For this purpose, several setups based on permanent magnets and electromagnets were simulated, designed and characterized. The simulations show that a distinction based on this method is possible for MBs with different magnetic particle moments. As a direct application of the developed magnetic reader in conjunction with digital demodulation, a magnetic assay against the B subunit of cholera toxin in drinking water was demonstrated, and a low detection limit of 0.2 ng/ml was achieved. KW - Choleratoxin B KW - Trinkwassersicherheit KW - cholera toxin B KW - drinking water safety KW - magnetic frequency mixing technique Y1 - 2020 U6 - http://dx.doi.org/10.18154/RWTH-2020-12052 N1 - Dissertation, RWTH Aachen University, 2020 ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Neuendorf, Christian A1 - Faßbender, Tobias A1 - Nölke, Greta A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - Sensitive and rapid detection of cholera toxin subunit B using magnetic frequency mixing detection JF - Plos One N2 - Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin’s B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more than 700 ng/ml. Y1 - 2019 U6 - http://dx.doi.org/10.1371/journal.pone.0219356 SN - 1932-6203 VL - 14 IS - 7 PB - Plos CY - San Francisco ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Pourshahidi, Ali Mohammad A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Multiplex detection of different magnetic beads using frequency scanning in magnetic frequency mixing technique JF - Sensors N2 - In modern bioanalytical methods, it is often desired to detect several targets in one sample within one measurement. Immunological methods including those that use superparamagnetic beads are an important group of techniques for these applications. The goal of this work is to investigate the feasibility of simultaneously detecting different superparamagnetic beads acting as markers using the magnetic frequency mixing technique. The frequency of the magnetic excitation field is scanned while the lower driving frequency is kept constant. Due to the particles’ nonlinear magnetization, mixing frequencies are generated. To record their amplitude and phase information, a direct digitization of the pickup-coil’s signal with subsequent Fast Fourier Transformation is performed. By synchronizing both magnetic beads using frequency scanning in magnetic frequency mixing technique magnetic fields, a stable phase information is gained. In this research, it is shown that the amplitude of the dominant mixing component is proportional to the amount of superparamagnetic beads inside a sample. Additionally, it is shown that the phase does not show this behaviour. Excitation frequency scans of different bead types were performed, showing different phases, without correlation to their diverse amplitudes. Two commercially available beads were selected and a determination of their amount in a mixture is performed as a demonstration for multiplex measurements. KW - frequency mixing magnetic detection KW - magnetic sandwich immunoassay KW - multiparametric immunoassays Y1 - 2019 U6 - http://dx.doi.org/10.3390/s19112599 SN - 1424-8220 VL - 19 IS - 11 PB - MDPI CY - Basel ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Schönenborn, Kristina A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Measurement of the magnetophoretic velocity of different superparamagnetic beads JF - Journal of Magnetism and Magnetic Materials N2 - The movement of magnetic beads due to a magnetic field gradient is of great interest in different application fields. In this report we present a technique based on a magnetic tweezers setup to measure the velocity factor of magnetically actuated individual superparamagnetic beads in a fluidic environment. Several beads can be tracked simultaneously in order to gain and improve statistics. Furthermore we show our results for different beads with hydrodynamic diameters between 200 and 1000 nm from diverse manufacturers. These measurement data can, for example, be used to determine design parameters for a magnetic separation system, like maximum flow rate and minimum separation time, or to select suitable beads for fixed experimental requirements. KW - magnetophoretic velocity KW - superparamagnetic bead KW - magnetic tweezers KW - magnetic separation KW - magnetic actuation Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.jmmm.2018.10.066 SN - 0304-8853 VL - 477 IS - 1 SP - 244 EP - 248 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Tödter, Julia A1 - Niehues, Julia A1 - Telöken, Matthias A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - 3D printed modular immunofiltration columns for frequency mixing-based multiplex magnetic immunodetection JF - Sensors N2 - For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated. Y1 - 2019 U6 - http://dx.doi.org/10.3390/s19010148 SN - 1424-8220 VL - 19 IS - 1 PB - MDPI CY - Basel ER - TY - JOUR A1 - Almajhdi, Fahad N. A1 - Senger, Tilo A1 - Amer, Haitham M. A1 - Gissmann, Lutz A1 - Öhlschläger, Peter T1 - Design of a highly effective therapeutic HPV16 E6/E7-specific DNA vaccine: optimization by different ways of sequence rearrangements (Shuffling) JF - PLOS one N2 - Persistent infection with the high-risk Human Papillomavirus type 16 (HPV 16) is the causative event for the development of cervical cancer and other malignant tumors of the anogenital tract and of the head and neck. Despite many attempts to develop therapeutic vaccines no candidate has entered late clinical trials. An interesting approach is a DNA based vaccine encompassing the nucleotide sequence of the E6 and E7 viral oncoproteins. Because both proteins are consistently expressed in HPV infected cells they represent excellent targets for immune therapy. Here we report the development of 8 DNA vaccine candidates consisting of differently rearranged HPV-16 E6 and E7 sequences within one molecule providing all naturally occurring epitopes but supposedly lacking transforming activity. The HPV sequences were fused to the J-domain and the SV40 enhancer in order to increase immune responses. We demonstrate that one out of the 8 vaccine candidates induces very strong cellular E6- and E7- specific cellular immune responses in mice and, as shown in regression experiments, efficiently controls growth of HPV 16 positive syngeneic tumors. This data demonstrates the potential of this vaccine candidate to control persistent HPV 16 infection that may lead to malignant disease. It also suggests that different sequence rearrangements influence the immunogenecity by an as yet unknown mechanism. Y1 - 2014 U6 - http://dx.doi.org/10.1371/journal.pone.0113461 SN - 1932-6203 VL - 11 IS - 9 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Arida, Hassan A. A1 - Al-haddad, Ameera A1 - Schöning, Michael Josef T1 - New Solid-State Organic Membrane Based Lead-Selective Micro-Electrode JF - International Journal of Electrochemical Science. 6 (2011), H. 9 Y1 - 2011 SN - 1452-3981 SP - 3858 EP - 3867 ER - TY - CHAP A1 - Arida, Hassan A. A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations N2 - A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors. KW - Biosensor KW - Heavy metal detection KW - thin-film microsensors KW - organic PVC membranes Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1545 ER - TY - JOUR A1 - Arida, Hassan A1 - Mohsen, Q. A1 - Schöning, Michael Josef T1 - Microfabrication, characterization and analytical application of a new thin-film silver microsensor JF - Electrochimica Acta. 54 (2009), H. 13 Y1 - 2009 SN - 0013-4686 SP - 3543 EP - 3547 ER - TY - JOUR A1 - Arida, Hassan A1 - Turek, Monika A1 - Rolka, David A1 - Schöning, Michael Josef T1 - A Novel Thin-Film Copper Array Based on an Organic/Inorganic Sensor Hybrid: Microfabrication, Potentiometric Characterization, and Flow-Injection Analysis Application JF - Electroanalysis. 21 (2009), H. 10 Y1 - 2009 SN - 1040-0397 SP - 1145 EP - 1151 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Effect of O2 plasma on properties of electrolyte-insulator-semiconductor structures JF - physica status solidi a : applications and materials sciences N2 - Prior to immobilization of biomolecules or cells onto biosensor surfaces, the surface must be physically or chemically activated for further functionalization. Organosilanes are a versatile option as they facilitate the immobilization through their terminal groups and also display self-assembly. Incorporating hydroxyl groups is one of the important methods for primary immobilization. This can be done, for example, with oxygen plasma treatment. However, this treatment can affect the performance of the biosensors and this effect is not quite well understood for surface functionalization. In this work, the effect of O2 plasma treatment on EIS sensors was investigated by means of electrochemical characterizations: capacitance–voltage (C–V) and constant capacitance (ConCap) measurements. After O2 plasma treatment, the potential of the EIS sensor dramatically shifts to a more negative value. This was successfully reset by using an annealing process. KW - surface functionalization KW - O2 plasma KW - hydroxylation KW - electrolyte-insulator semiconductor sensor (EIS) KW - annealing Y1 - 2017 U6 - http://dx.doi.org/10.1002/pssa.201700025 SN - 1862-6319 VL - 214 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Toward an immobilization method for spore-based biosensors in oxidative environment JF - Electrochimica Acta Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.electacta.2019.01.148 VL - 302 SP - 394 EP - 401 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Combined calorimetric gas- and spore-based biosensor array for online monitoring and sterility assurance of gaseous hydrogen peroxide in aseptic filling machines JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2019.111628 SN - 0956-5663 VL - 143 IS - 111628 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arreola, Julio A1 - Mätzkow, Malte A1 - Durán, Marlena Palomar A1 - Greeff, Anton A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Optimization of the immobilization of bacterial spores on glass substrates with organosilanes JF - Physica status solidi (A) : Applications and materials science N2 - Spores can be immobilized on biosensors to function as sensitive recognition elements. However, the immobilization can affect the sensitivity and reproducibility of the sensor signal. In this work, three different immobilization strategies with organosilanes were optimized and characterized to immobilize Bacillus atrophaeus spores on glass substrates. Five different silanization parameters were investigated: nature of the solvent, concentration of the silane, silanization time, curing process, and silanization temperature. The resulting silane layers were resistant to a buffer solution (e.g., Ringer solution) with a polysorbate (e.g., Tween®80) and sonication. KW - silanization KW - organosilanes KW - immobilization KW - endospores KW - biosensors KW - Bacillus atrophaeus Y1 - 2016 U6 - http://dx.doi.org/10.1002/pssa.201532914 SN - 1862-6319 VL - 213 IS - 6 SP - 1463 EP - 1470 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Arreola, Julio A1 - Oberländer, Jan A1 - Mätzkow, M. A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Surface functionalization for spore-based biosensors with organosilanes JF - Electrochimica Acta N2 - In the present work, surface functionalization of different sensor materials was studied. Organosilanes are well known to serve as coupling agent for biomolecules or cells on inorganic materials. 3-aminopropyltriethoxysilane (APTES) was used to attach microbiological spores time to an interdigitated sensor surface. The functionality and physical properties of APTES were studied on isolated sensor materials, namely silicon dioxide (SiO2) and platinum (Pt) as well as the combined material on sensor level. A predominant immobilization of spores could be demonstrated on SiO2 surfaces. Additionally, the impedance signal of APTES-functionalized biosensor chips has been investigated. Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.electacta.2017.04.157 SN - 0013-4686 VL - 241 SP - 237 EP - 243 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bandodkar, Amay J. A1 - Molinnus, Denise A1 - Mirza, Omar A1 - Guinovart, Tomas A1 - Windmiller, Joshua R. A1 - Valdes-Ramirez, Gabriela A1 - Andrade, Francisco J. A1 - Schöning, Michael Josef A1 - Wang, Joseph T1 - Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring JF - Biosensors and bioelectronics N2 - This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.bios.2013.11.039 SN - 1873-4235 (E-Journal); 0956-5663 (Print) VL - 54 SP - 603 EP - 609 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Beging, Stefan A1 - Leinhos, Marcel A1 - Jablonski, Melanie A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Studying the spatially resolved immobilisation of enzymes on a capacitive field-effect structure by means of nano-spotting JF - Physica status solidi (a) Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431891 SN - 1862-6319 VL - 212 IS - 6 SP - 1353 EP - 1358 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Beging, Stefan A1 - Mlynek, Daniela A1 - Hataihimakul, Sudkanung A1 - Poghossian, Arshak A1 - Baldsiefen, Gerhard A1 - Busch, Heinz A1 - Laube, Norbert A1 - Kleinen, Lisa A1 - Schöning, Michael Josef T1 - Field-effect calcium sensor for the determination of the risk of urinary stone formation JF - Sensors and Actuators B: Chemical. 144 (2010), H. 2 Y1 - 2010 N1 - 22nd International Conference on Eurosensors - Dresden, Germany, 7-10 September 2008 ; Eurosensors ; (22, 2008, Dresden) SP - 374 EP - 379 ER - TY - CHAP A1 - Beging, Stefan A1 - Poghossian, Arshak A1 - Mlynek, D. A1 - Hataihimakul, S. A1 - Pedraza, A. A1 - Dhawan, S. A1 - Laube, N. A1 - Kleinen, L. A1 - Baldsiefen, G. A1 - Busch, H. A1 - Schöning, Michael Josef T1 - Ion-selective sensors for the determination of the risk of urinary stone formation T2 - Micro- and Nanosystems in biochemical diagnosis : Principles and applications Y1 - 2010 SP - 74 EP - 80 CY - Warsaw ER - TY - JOUR A1 - Beging, Stefan A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Hataihimakul, Sudkanung A1 - Busch, H. A1 - Baldsiefen, G. A1 - Laube, N. A1 - Kleinen, L. A1 - Hosseiny, R. T1 - Feldeffektbasierender Ca2+-sensitiver Sensor für den Einsatz im Nativurin zur Bestimmung des Harnsteinbildungsrisikos JF - Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. März 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2008 SN - 978-3-18-092011-5 N1 - VDI-Berichte ; 2011 ; Sensoren und Messsysteme 2008, 14. GMA/ITG-Fachtagung, VDI/VDE- Gesellschaft Mess- und Automatisierungstechnik, + CD-ROM, Ludwigsburg, DE, 11.-12. Mar, 2008 SP - 775 EP - 782 PB - VDI-Verl. CY - Düsseldorf ER - TY - PAT A1 - Berger, Eric G. A1 - Biselli, Manfred A1 - Dinter, André A1 - Eisenkrätzer, Detlef A1 - Kiesewetter, André A1 - Zeng, Steffen T1 - Chinese-Hamster-Ovary-Zellen zur Produktion von Proteinen T1 - Chinese hamster ovary cells, useful for large-scale production of recombinant proteins, especially enzymes Y1 - 2000 N1 - DE000019847422C1 13.01.2000 EP000001121417A2 08.08.2001 WO002000022096A9 24.08.2000 SP - 1 EP - 6 ER - TY - JOUR A1 - Bertz, Morten A1 - Molinnus, Denise A1 - Schöning, Michael Josef A1 - Homma, Takayuki T1 - Real-time monitoring of H₂O₂ sterilization on individual bacillus atrophaeus spores by optical sensing with trapping Raman spectroscopy JF - Chemosensors N2 - Hydrogen peroxide (H₂O₂), a strong oxidizer, is a commonly used sterilization agent employed during aseptic food processing and medical applications. To assess the sterilization efficiency with H₂O₂, bacterial spores are common microbial systems due to their remarkable robustness against a wide variety of decontamination strategies. Despite their widespread use, there is, however, only little information about the detailed time-resolved mechanism underlying the oxidative spore death by H₂O₂. In this work, we investigate chemical and morphological changes of individual Bacillus atrophaeus spores undergoing oxidative damage using optical sensing with trapping Raman microscopy in real-time. The time-resolved experiments reveal that spore death involves two distinct phases: (i) an initial phase dominated by the fast release of dipicolinic acid (DPA), a major spore biomarker, which indicates the rupture of the spore’s core; and (ii) the oxidation of the remaining spore material resulting in the subsequent fragmentation of the spores’ coat. Simultaneous observation of the spore morphology by optical microscopy corroborates these mechanisms. The dependence of the onset of DPA release and the time constant of spore fragmentation on H₂O₂ shows that the formation of reactive oxygen species from H₂O₂ is the rate-limiting factor of oxidative spore death. KW - DPA (dipicolinic acid) KW - sterilization KW - Bacillus atrophaeus spores KW - optical trapping KW - Raman spectroscopy KW - optical sensor setup Y1 - 2023 U6 - http://dx.doi.org/10.3390/chemosensors11080445 SN - 2227-9040 N1 - This article belongs to the Special Issue "Biosensors and Chemical Sensors for Food and Healthcare Monitoring—Celebrating the 10th Anniversary" VL - 8 IS - 11 PB - MDPI CY - Basel ER - TY - JOUR A1 - Bertz, Morten A1 - Schöning, Michael Josef A1 - Molinnus, Denise A1 - Homma, Takayuki T1 - Influence of temperature, light, and H₂O₂ concentration on microbial spore inactivation: in-situ Raman spectroscopy combined with optical trapping JF - Physica status solidi (a) applications and materials science N2 - To gain insight on chemical sterilization processes, the influence of temperature (up to 70 °C), intense green light, and hydrogen peroxide (H₂O₂) concentration (up to 30% in aqueous solution) on microbial spore inactivation is evaluated by in-situ Raman spectroscopy with an optical trap. Bacillus atrophaeus is utilized as a model organism. Individual spores are isolated and their chemical makeup is monitored under dynamically changing conditions (temperature, light, and H₂O₂ concentration) to mimic industrially relevant process parameters for sterilization in the field of aseptic food processing. While isolated spores in water are highly stable, even at elevated temperatures of 70 °C, exposure to H₂O₂ leads to a loss of spore integrity characterized by the release of the key spore biomarker dipicolinic acid (DPA) in a concentration-dependent manner, which indicates damage to the inner membrane of the spore. Intensive light or heat, both of which accelerate the decomposition of H₂O₂ into reactive oxygen species (ROS), drastically shorten the spore lifetime, suggesting the formation of ROS as a rate-limiting step during sterilization. It is concluded that Raman spectroscopy can deliver mechanistic insight into the mode of action of H₂O₂-based sterilization and reveal the individual contributions of different sterilization methods acting in tandem. KW - hydrogen peroxide KW - optical spore trapping KW - Raman spectroscopy KW - sterilization conditions KW - temperature Y1 - 2024 U6 - http://dx.doi.org/10.1002/pssa.202300866 SN - 1862-6319 (Online) SN - 1862-6300 (Print) IS - Early View PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Biselli, Manfred A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Schnitzler, Thomas A1 - Zang, Werner A1 - Wagner, P. T1 - Entwicklung eines modularen festkörperbasierten Sensorsystems für die Überwachung von Zellkulturfermenationen JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 688 EP - 691 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fleischer, M. A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 17 EP - 20 ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Stütz, Evamaria A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Detection of toxic chromium species in water using cellbased sensor systems Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/P2.1.14 SP - 1364 EP - 1367 ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Eukaryotic cell lines as a sensitive layer for direct monitoring of carbon monoxide JF - Physica status solidi (a) : applications and material science. 208 (2011), H. 6 Y1 - 2011 SN - 1862-6319 SP - 1345 EP - 1350 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro JF - Biosensors and Bioelectronics. 40 (2013), H. 1 Y1 - 2013 SN - 0956-5663 SP - 393 EP - 400 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Living cell-based gas sensor system for the detection of acetone in air Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/3.2.3 SP - 269 EP - 272 ER - TY - JOUR A1 - Bongaerts, Johannes A1 - Esser, Simon A1 - Lorbach, Volker A1 - Al-Momani, Lóay A1 - Müller, Michael A. A1 - Franke, Dirk A1 - Grondal, Christoph A1 - Kurutsch, Anja A1 - Bujnicki, Robert A1 - Takors, Ralf A1 - Raeven, Leon A1 - Wubbolts, Marcel A1 - Bovenberg, Roel A1 - Nieger, Martin A1 - Schürmann, Melanie A1 - Trachtmann, Natalie A1 - Kozak, Stefan A1 - Sprenger, Georg A. A1 - Müller, Michael T1 - Diversity-oriented production of metabolites derived from chorismate and their use in organic synthesis JF - Angewandte Chemie International Edition Y1 - 2011 SN - 1521-3773 (E-Journal); 0570-0833 (Print); 1433-7851 (Print) VL - Vol. 50 IS - Iss. 34 SP - 7781 EP - 7786 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Borgmeier, Claudia A1 - Bongaerts, Johannes A1 - Meinhardt, Friedhelm T1 - Genetic analysis of the Bacillus licheniformis degSU operon and the impact of regulatory mutations on protease production JF - Journal of biotechnology N2 - Disruption experiments targeted at the Bacillus licheniformis degSU operon and GFP-reporter analysis provided evidence for promoter activity immediately upstream of degU. pMutin mediated concomitant introduction of the degU32 allele – known to cause hypersecretion in Bacillus subtilis – resulted in a marked increase in protease activity. Application of 5-fluorouracil based counterselection through establishment of a phosphoribosyltransferase deficient Δupp strain eventually facilitated the marker-free introduction of degU32 leading to further protease enhancement achieving levels as for hypersecreting wild strains in which degU was overexpressed. Surprisingly, deletion of rapG – known to interfere with DegU DNA-binding in B. subtilis – did not enhance protease production neither in the wild type nor in the degU32 strain. The combination of degU32 and Δupp counterselection in the type strain is not only equally effective as in hypersecreting wild strains with respect to protease production but furthermore facilitates genetic strain improvement aiming at biological containment and effectiveness of biotechnological processes. KW - Marker-free mutagenesis KW - Extracellular enzymes KW - Uracil-phosphoribosyltransferase KW - Hypersecretion Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiotec.2012.02.011 SN - 1873-4863 (E-Journal); 0168-1656 (Print) VL - 159 IS - 1-2 SP - 12 EP - 20 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Brahma, Aischarya A1 - Musio, Biagia A1 - Ismayilova, Uliviya A1 - Nikbin, Nikzad A1 - Kamptmann, Sonja B. A1 - Siegert, Petra A1 - Jeromin, Günter Erich A1 - Ley, Steven A1 - Pohl, Martina T1 - An orthogonal biocatalytic approach for the safe generation and use of HCN in a multi-step continuous preparation of chiral O-acetylcyanohydrins JF - Synlett Y1 - 2015 U6 - http://dx.doi.org/10.1055/s-0035-1560644 SN - 0936-5214 (Print) ; 1437-2096 (e-Journal) IS - Publ. online 29.09.2015 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Bressel, A. A1 - Schultze, J.W. A1 - Khan, W. A1 - Wolfaardt, G. M. A1 - Rohns, H.-P. A1 - Irmscher, R. A1 - Schöning, Michael Josef T1 - High resolution gravimetric, optical and electrochemical investigations of microbial biofilm formation in aqueous systems JF - Electrochimica Acta. 48 (2003), H. 20-22 Y1 - 2003 SN - 0013-4686 SP - 3363 EP - 3372 ER - TY - JOUR A1 - Breuer, Lars A1 - Mang, Thomas A1 - Schöning, Michael Josef A1 - Thoelen, Ronald A1 - Wagner, Torsten T1 - Investigation of the spatial resolution of a laser-based stimulation process for light-addressable hydrogels with incorporated graphene oxide by means of IR thermography JF - Sensors and Actuators A: Physical Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.sna.2017.11.031 SN - 0924-4247 VL - 268 SP - 126 EP - 132 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Breuer, Lars A1 - Pilas, Johanna A1 - Guthmann, Eric A1 - Schöning, Michael Josef A1 - Thoelen, Ronald A1 - Wagner, Torsten T1 - Towards light-addressable flow control: responsive hydrogels with incorporated graphene oxide as laser-driven actuator structures within microfluidic channels JF - Sensor and Actuators B: Chemical Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.snb.2019.02.086 SN - 0925-4005 VL - 288 SP - 579 EP - 585 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Breuer, Lars A1 - Raue, Markus A1 - Kirschbaum, M. A1 - Mang, Thomas A1 - Schöning, Michael Josef A1 - Thoelen, R. A1 - Wagner, Torsten T1 - Light-controllable polymeric material based on temperature-sensitive hydrogels with incorporated graphene oxide JF - Physica status solidi (a) N2 - Poly(N-isopropylacrylamide) (PNIPAAm) hydrogel films with incorporated graphene oxide (GO) were developed and tested as light-stimulated actuators. GO dispersions were synthesized via Hummers method and characterized toward their optical properties and photothermal energy conversion. The hydrogels were prepared by means of photopolymerization. In addition, the influence of GO within the hydrogel network on the lower critical solution temperature (LCST) was investigated by differential scanning calorimetry (DSC). The optical absorbance and the response to illumination were determined as a function of GO concentration for thin hydrogel films. A proof of principle for the stimulation with light was performed. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431944 SN - 1862-6319 VL - 212 IS - 6 SP - 1368 EP - 1374 PB - Wiley CY - Weinheim ER -