TY - JOUR A1 - Baatz, Udo T1 - 82.000 FL/h - Eine neue Dimension in der Abfüllung von Erfrischungsgetränken JF - Das Erfrischungsgetränk - Mineralwasser-Zeitung Y1 - 1974 SN - 0342-2232 VL - 27 IS - 14 SP - 341 EP - 345 PB - Matthaes CY - Stuttgart ER - TY - JOUR A1 - Baatz, Udo T1 - Flaschenbehandlung bei hohen Leistungen – Problemstellung und Lösungsmöglichkeiten JF - Das Erfrischungsgetränk - Mineralwasser-Zeitung Y1 - 1974 SN - 0342-2232 VL - 27 IS - 15 SP - 1175 EP - 1178 PB - Matthaes CY - Stuttgart ER - TY - JOUR A1 - Baatz, Udo T1 - Zur Problematik der Etikettenentfernung JF - Das Erfrischungsgetränk - Mineralwasser-Zeitung Y1 - 1974 SN - 0342-2232 N1 - Tagungs-Sondernummer VL - 27 IS - 39 SP - 926 EP - 928 PB - Matthaes CY - Stuttgart ER - TY - JOUR A1 - Baatz, Udo T1 - Wie erkennt man Rationalisierungsreserven im Konstruktionsbereich JF - Das Jahrbuch für Ingeneure 79 : aktuelles Wissen aus Forschung u. Praxis / Bartz, Wilfried J.; Wippler, Elmar Y1 - 1979 SN - 0171-3809 SP - 263 EP - 268 PB - Expert-Verl. CY - Grafenau, Württ. ER - TY - JOUR A1 - Baader, Fabian A1 - Boxberg, Marc S. A1 - Chen, Qian A1 - Förstner, Roger A1 - Kowalski, Julia A1 - Dachwald, Bernd T1 - Field-test performance of an ice-melting probe in a terrestrial analogue environment JF - Icarus N2 - Melting probes are a proven tool for the exploration of thick ice layers and clean sampling of subglacial water on Earth. Their compact size and ease of operation also make them a key technology for the future exploration of icy moons in our Solar System, most prominently Europa and Enceladus. For both mission planning and hardware engineering, metrics such as efficiency and expected performance in terms of achievable speed, power requirements, and necessary heating power have to be known. Theoretical studies aim at describing thermal losses on the one hand, while laboratory experiments and field tests allow an empirical investigation of the true performance on the other hand. To investigate the practical value of a performance model for the operational performance in extraterrestrial environments, we first contrast measured data from terrestrial field tests on temperate and polythermal glaciers with results from basic heat loss models and a melt trajectory model. For this purpose, we propose conventions for the determination of two different efficiencies that can be applied to both measured data and models. One definition of efficiency is related to the melting head only, while the other definition considers the melting probe as a whole. We also present methods to combine several sources of heat loss for probes with a circular cross-section, and to translate the geometry of probes with a non-circular cross-section to analyse them in the same way. The models were selected in a way that minimizes the need to make assumptions about unknown parameters of the probe or the ice environment. The results indicate that currently used models do not yet reliably reproduce the performance of a probe under realistic conditions. Melting velocities and efficiencies are constantly overestimated by 15 to 50 % in the models, but qualitatively agree with the field test data. Hence, losses are observed, that are not yet covered and quantified by the available loss models. We find that the deviation increases with decreasing ice temperature. We suspect that this mismatch is mainly due to the too restrictive idealization of the probe model and the fact that the probe was not operated in an efficiency-optimized manner during the field tests. With respect to space mission engineering, we find that performance and efficiency models must be used with caution in unknown ice environments, as various ice parameters have a significant effect on the melting process. Some of these are difficult to estimate from afar. Y1 - 2023 U6 - https://doi.org/10.1016/j.icarus.2023.115852 N1 - Forschungsdaten hierzu: "Performance data of an ice-melting probe from field tests in two different ice environments" (https://opus.bibliothek.fh-aachen.de/opus4/frontdoor/index/index/docId/10890) IS - 409 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ayed, Anis Haj A1 - Kusterer, Karsten A1 - Funke, Harald A1 - Keinz, Jan A1 - Bohn, D. T1 - CFD based exploration of the dry-low-NOx hydrogen micromix combustion technology at increased energy densities JF - Propulsion and Power Research KW - Micromix combustion KW - Hydrogen gas turbine KW - Hydrogen combustion KW - High hydrogen combustion KW - Dry-low-NOx (DLN) combustion Y1 - 2017 SN - 2212-540X U6 - https://doi.org/10.1016/j.jppr.2017.01.005 VL - 6 IS - 1 SP - 15 EP - 24 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ayed, Anis Haj A1 - Kusterer, Karsten A1 - Funke, Harald A1 - Keinz, Jan T1 - CFD Based Improvement of the DLN Hydrogen Micromix Combustion Technology at Increased Energy Densities JF - American Scientific Research Journal for Engineering, Technology, and Sciences (ASRJETS) N2 - Combined with the use of renewable energy sources for its production, Hydrogen represents a possible alternative gas turbine fuel within future low emission power generation. Due to the large difference in the physical properties of Hydrogen compared to other fuels such as natural gas, well established gas turbine combustion systems cannot be directly applied for Dry Low NOx (DLN) Hydrogen combustion. Thus, the development of DLN combustion technologies is an essential and challenging task for the future of Hydrogen fuelled gas turbines. The DLN Micromix combustion principle for hydrogen fuel has been developed to significantly reduce NOx-emissions. This combustion principle is based on cross-flow mixing of air and gaseous hydrogen which reacts in multiple miniaturized diffusion-type flames. The major advantages of this combustion principle are the inherent safety against flash-back and the low NOx-emissions due to a very short residence time of reactants in the flame region of the micro-flames. The Micromix Combustion technology has been already proven experimentally and numerically for pure Hydrogen fuel operation at different energy density levels. The aim of the present study is to analyze the influence of different geometry parameter variations on the flame structure and the NOx emission and to identify the most relevant design parameters, aiming to provide a physical understanding of the Micromix flame sensitivity to the burner design and identify further optimization potential of this innovative combustion technology while increasing its energy density and making it mature enough for real gas turbine application. The study reveals great optimization potential of the Micromix Combustion technology with respect to the DLN characteristics and gives insight into the impact of geometry modifications on flame structure and NOx emission. This allows to further increase the energy density of the Micromix burners and to integrate this technology in industrial gas turbines. Y1 - 2016 SN - 2313-4402 VL - 26 IS - 3 SP - 290 EP - 303 PB - GSSRR ER - TY - JOUR A1 - Ayala, Rafael Ceja A1 - Harris, Isaac A1 - Kleefeld, Andreas A1 - Pallikarakis, Nikolaos T1 - Analysis of the transmission eigenvalue problem with two conductivity parameters JF - Applicable Analysis N2 - In this paper, we provide an analytical study of the transmission eigenvalue problem with two conductivity parameters. We will assume that the underlying physical model is given by the scattering of a plane wave for an isotropic scatterer. In previous studies, this eigenvalue problem was analyzed with one conductive boundary parameter whereas we will consider the case of two parameters. We prove the existence and discreteness of the transmission eigenvalues as well as study the dependence on the physical parameters. We are able to prove monotonicity of the first transmission eigenvalue with respect to the parameters and consider the limiting procedure as the second boundary parameter vanishes. Lastly, we provide extensive numerical experiments to validate the theoretical work. KW - Transmission Eigenvalues KW - Conductive Boundary Condition KW - Inverse Scattering Y1 - 2023 U6 - https://doi.org/10.1080/00036811.2023.2181167 SN - 0003-6811 PB - Taylor & Francis ER - TY - JOUR A1 - Ayala, Rafael Ceja A1 - Harris, Isaac A1 - Kleefeld, Andreas T1 - Direct sampling method via Landweber iteration for an absorbing scatterer with a conductive boundary JF - Inverse Problems and Imaging N2 - In this paper, we consider the inverse shape problem of recovering isotropic scatterers with a conductive boundary condition. Here, we assume that the measured far-field data is known at a fixed wave number. Motivated by recent work, we study a new direct sampling indicator based on the Landweber iteration and the factorization method. Therefore, we prove the connection between these reconstruction methods. The method studied here falls under the category of qualitative reconstruction methods where an imaging function is used to recover the absorbing scatterer. We prove stability of our new imaging function as well as derive a discrepancy principle for recovering the regularization parameter. The theoretical results are verified with numerical examples to show how the reconstruction performs by the new Landweber direct sampling method. Y1 - 2024 U6 - https://doi.org/10.3934/ipi.2023051 SN - 1930-8337 SN - 1930-8345 (eISSN) VL - 18 IS - 3 SP - 708 EP - 729 PB - AIMS CY - Springfield ER - TY - JOUR A1 - Augenstein, Eckardt A1 - Herbergs, S. A1 - Kuperjans, Isabel T1 - TOP-Energy : ein Werkzeug zur Optimierung der Gebäudeenergieversorgung JF - KI : Kälte, Luft, Klimatechnik Y1 - 2006 SN - 1865-5432 IS - 5 SP - 198 EP - 201 ER - TY - JOUR A1 - Auffray, E. A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Attar, Mandana Hossein Zadeh A1 - Merk, Hans F. A1 - Kotliar, Konstantin A1 - Wurpts, Gerda A1 - Röseler, Stefani A1 - Moll-Slodowy, Silke A1 - Plange, Johann A1 - Baron, Jens Malte A1 - Balakirski, Galina T1 - The CD63 basophil activation test as a diagnostic tool for assessing autoimmunity in patients with chronic spontaneous urticaria JF - European Journal of Dermatology Y1 - 2019 U6 - https://doi.org/10.1684/ejd.2019.3680 VL - 29 IS - 6 SP - 614 EP - 618 ER - TY - JOUR A1 - Atlas, Glen A1 - Brealey, David A1 - Dhar, Sunil A1 - Dikta, Gerhard A1 - Singer, Meryvn T1 - Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting JF - Journal of clinical monitoring and computing N2 - The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated. KW - Acceleration KW - Velocity KW - Kinetic energy KW - Force KW - Compliance KW - Afterload KW - Contractility KW - Volume status KW - Esophageal Doppler monitor Y1 - 2012 SN - 1573-2614 U6 - https://doi.org/10.1007/s10877-012-9386-5 IS - 26 SP - 473 EP - 482 PB - Springer Nature CY - London ER - TY - JOUR A1 - Asante-Asamani, E.O. A1 - Kleefeld, Andreas A1 - Wade, B.A. T1 - A second-order exponential time differencing scheme for non-linear reaction-diffusion systems with dimensional splitting JF - Journal of Computational Physics N2 - A second-order L-stable exponential time-differencing (ETD) method is developed by combining an ETD scheme with approximating the matrix exponentials by rational functions having real distinct poles (RDP), together with a dimensional splitting integrating factor technique. A variety of non-linear reaction-diffusion equations in two and three dimensions with either Dirichlet, Neumann, or periodic boundary conditions are solved with this scheme and shown to outperform a variety of other second-order implicit-explicit schemes. An additional performance boost is gained through further use of basic parallelization techniques. KW - Exponential time differencing KW - Real distinct pole KW - Dimensional splitting KW - Reaction-diffusion systems KW - Matrix exponential Y1 - 2020 U6 - https://doi.org/10.1016/j.jcp.2020.109490 SN - 0021-9991 N1 - Corresponding author: Andreas Kleefeld VL - 415 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zhou-Stache, J. A1 - Buettner, R. A1 - Mittermayer, C. [u.a.] T1 - Inhibition of TNF-alpha induced cell death in HUVEC and Jurkat cells by protocatechuic acid. Zhou-Stache, J.; Buettner, R.; Artmann, Gerhard Michael; Mittermayer, C.; Bosserhoff, A. K. JF - Medical and Biological Engineering and Computing. 40 (2002), H. 6 Y1 - 2002 SN - 0140-0118 SP - 698 EP - 703 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Stadler, Andreas M. T1 - Physical discontinuities at body temperature in human red blood cells / Artmann, GM ; Zerlin, K ; Digel, I ; Stadler, A ; Zaccai, G ; Temiz, AA JF - Tissue Engineering. 13 (2007), H. 7 Y1 - 2007 SN - 1076-3279 N1 - TERMIS-EU Meeting Abstracts London, UK September 4–7, 2007 SP - 1778 EP - 1778 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zerlin, Kay A1 - Digel, Ilya T1 - Hemoglobin Senses Body Temperature JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 415 EP - 447 PB - Springer CY - Berlin ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zang, Werner T1 - Fully automatic measurement of rheologic parameters of red blood cells = Laborautomat zur Messung mechanischer Eigenschaften roter Blutzellen JF - Biomedizinische Technik = Biomedical engineering. 35 (1990), H. Suppl. 3 Y1 - 1990 SN - 0013-5585 SP - 94 EP - 96 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zang, Werner T1 - Vollautomatische Messung rheologischer Parameter roter Blutzellen JF - Biomedizinische Technik / Biomedical Engineering Y1 - 1990 SN - 0013-5585 VL - 35 IS - S3 SP - 94 EP - 96 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Witte, Ch. T1 - Expertensystem für Personal Computer zur Strukturbestimmung des Circulus Arteriosus Willisii mittels transkranieller Dopplersonografie. Witte, Ch.; Artmann, Gerhard Michael JF - Biomedizinische Technik = Biomedical engineering. 36 (1991) Y1 - 1991 SN - 0013-5585 SP - 228 EP - 230 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Vogel, A. A1 - Zink, S. A1 - Stache, O. T1 - Entwicklung eines automatisierten, computergesteuerten Permeabilitätsanalysators zur Messung an Endothelzellen / Vogel, A. ; Zinke, S. ; Stache, O. ; Königsfeld, J. ; Artmann, G. JF - Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1 Y1 - 2000 SN - 1862-278X SP - 479 EP - 480 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Trzewik, Jürgen A1 - Mallipattu, S. K. A1 - Delano, F. A. [u.a.] T1 - Evidence for a second valve system in Lymphatics: Endothelial Microvalves. Trzewik, Jürgen; Mallipattu, S. K.; Artmann, Gerhard Michael; Delano, F. A.; Schmid-Schonbein, G. W JF - The FASEB Journal. 15 (2001) Y1 - 2001 SN - 1530-6860 SP - 1711 EP - 1717 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Trzewik, Jürgen A1 - Ates, M. T1 - A novel method to quantify mechanical tension in cell monolayers. Trzewik, Jürgen; Ates, M., Artmann, Gerhard Michael JF - Biomedizinische Technik. 47 (2002), H. Suppl. 1. Pt. 1 Y1 - 2002 SN - 0013-5585 N1 - Druckausgabe unter 63 Z 47 vorhanden SP - 379 EP - 381 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Trzewik, J. A1 - Schmid-Schönbein, G. W. T1 - Investigation on lymphatic endothelial microvalves / Trzewik, J. ; Artmann, G. M. ; Schmid-Schönbein, G. W. JF - Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1 Y1 - 2000 SN - 1862-278X SP - 521 EP - 522 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Teitel, P. A1 - Schmid-Schönbein, H. T1 - Variable rheologische Antwort der Erythrozyten auf den Einfluß von Xantinderivaten (Coffein): Experimentelle Differenzierung von "Responders" und "Nonresponders" JF - 11. Jahrestagung der Gesellschaft für Mikrozirkulation Y1 - 1987 SP - 100 EP - 105 PB - Karger [u.a.] CY - Basel [u.a.] ER - TY - JOUR A1 - Artmann, Gerhard A1 - Sung, K.-L. Paul A1 - Horn, Thomas A1 - Whittemore, Darren [u.a.] T1 - Micropipette aspiration of human erythrocytes induces echinocytes via membrane phospholipid translocation. Artmann, Gerhard Michael; Sung, K.-L. Paul; Horn, Thomas; Whittemore, Darren; Norwich, Gerald; Chien, Shu JF - Biophysical journal. 72 (1997), H. 3 Y1 - 1997 SN - 1542-0086 SP - 1434 EP - 1441 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Stache, O. A1 - Königsfeld, J. T1 - Temperaturabhängigkeit der Pseudopodienbildung und Rückbildung von Granulozyten / Stache, O. ; Königsfeld, J. ; Artmann, G. M. JF - Biomedizinische Technik = Biomedical Engineering. 45 (2000), H. s1 Y1 - 2000 SN - 1862-278X SP - 450 EP - 451 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Shi, Young de A1 - Agosti, R. A1 - Longhini, E. T1 - A modified casson equation to characterize blood rheology for hypertension. Shi, Young de; Artmann, Gerhard Michael; Agosti, R.; Longhini, E. JF - Clinical Hemorheology Microcirculation. 19 (1998), H. 2 Y1 - 1998 SN - 1386-0291 SP - 115 EP - 127 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Schmid-Schönbein, H. A1 - Schröder, Susanne A1 - Grebe, R. [u.a.] T1 - Influence of Moxaverine-HCL on Membrane Curvature and Microsieve Filterability of Red Cells after Exposure to Hyperosmolarity and Lactacidosis. Schmid-Schönbein, H.; Schröder, Susanne; Grebe, R.; Artmann, Gerhard Michael, Eschweiler, H; Teitel, P. JF - Arzneimittelforschung. 38 (1988), H. 5 Y1 - 1988 SN - 0004-4172 SP - 710 EP - 716 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Schmid-Schönbein, H. A1 - Grebe, R. A1 - Teitel, P. [u.a.] T1 - Restoration of Microsieve Filterability of Human Red Cells After Exposure to Hyperosmolarity and Lactazidosis: Effect of Vinpocetine. Schmid-Schönbein, H.; Grebe, R.; Teitel, P.; Artmann, Gerhard Michael, Eschweiler, H.; Schröder, Susanne JF - Drug Development Research. 14 (1988), H. 3-4 Y1 - 1988 SN - 1098-2299 N1 - Abstracts frei unter: SP - 205 EP - 211 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Schmid-Schönbein, H. T1 - The microscope-photometrical-monolayer-technique- a new principle for analyzing the distribution of rheological responses in pathological and experimentally modified red cell populations. Artmann, Gerhard Michael; Schmid-Schönbein, H. JF - Microcirculation, an update : proceedings of the Fourth World Congress for Microcirculation, Tokyo, Japan, July 26-30, 1987 Y1 - 1987 SN - 0444809511 N1 - World Congress for Microcirculation (4, 1987, Tokyo;); International congress series ; 755 SP - 475 EP - 477 PB - Excerpta Medica CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Artmann, Gerhard A1 - Schikarsky, C. T1 - Ginkgo Biloba extract (EGb 761) protects red blood cells from oxidative damage. Artmann, Gerhard Michael; Schikarsky, C. JF - Clinical Hemorheology. 13 (1993), H. 4 Y1 - 1993 SN - 0271-5198 SP - 529 EP - 539 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Montanus, M. A1 - Teitel, P. T1 - Die photometrische Kapillaraggregation- ein neues Verfahren zur Messung der Erythrozytenaggregation. Montanus, M.; Artmann, Gerhard Michael; Teitel, P. JF - Biomedizinische Technik = Biomedical engineering. 36 (1991) Y1 - 1991 SN - 0013-5585 SP - 213 EP - 215 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Li, Anlan A1 - Ziemer, J. A1 - Schneider, G. [u.a.] T1 - A photometric method to analyze induced erythrocyte shape changes. Artmann, Gerhard Michael; Li, Anlan; Ziemer, J.; Schneider, G.; Sahm, U.: ; Ziemer, J.; Schneider, G.; Sahm, U. JF - Biorheology. 33 (1996), H. 3 Y1 - 1996 SN - 0006-355x SP - 251 EP - 265 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Li, Anlan A1 - Seipelt, H. A1 - Müller, C. [u.a.] T1 - Effects of salicylic acid derivatives on red blood cell membranes. Li, Anlan; Seipelt, H.; Müller, C.;Shi, Yong de; Artmann, Gerhard Michael JF - Pharmacology and Toxicology. 85 (1999) Y1 - 1999 SN - 0902-9938 SP - 206 EP - 211 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Li, Anlan T1 - Dihydroergocryptine maintains erythrocyte fluidity in acidotic and hyperosmolar suspensions modelling hypoxic and ischemic microcirculation. Li, Anlan; Artmann, Gerhard Michael JF - Clinical Hemorheology. 15 (1994), H. 2 Y1 - 1994 SN - 0271-5198 SP - 133 EP - 146 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Keller, U. A1 - Haas, J. A1 - Amort, U. A1 - Zang, Werner A1 - Karschies, S. T1 - Technik und ausgewählte Applikationen eines Membranbioassays roter Blutzellen JF - Biomedizinische Technik = Biomedical engineering. 36 (1991) Y1 - 1991 SN - 0013-5585 VL - 36 IS - S1 SP - 450 EP - 451 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Kelemen, Christina A1 - Porst, Dariusz A1 - Büldt, G. [u.a.] T1 - Temperature transitions of protein properties in human red blood cells. Artmann, Gerhard Michael, Kelemen, Christina; Porst, D.; Büldt, G.; Chien, S. JF - Biophysical Journal. 75 (1998), H. 6 Y1 - 1998 SN - 1542-0086 N1 - http://www.pubmedcentral.nih.gov/picrender.fcgi?artid=1299989&blobtype=pdf SP - 3179 EP - 3183 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Kelemen, C. A1 - Porst, Dariusz A1 - Büldt, G. T1 - Cellular engineering: Crash tests an menschlichen Erythrozyten geben Aufschluß über versteckte Materialeigenschaften zellulärer Proteine / Artmann, G. M. ; Kelemen, Ch. ; Porst, D. ; Büldt, G. ; Chien, Shu JF - Biomedizinische Technik / Biomedical Engineering. 43 (1998), H. s1 Y1 - 1998 SN - 1862-278 SP - 446 EP - 447 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Kelemen, C. A1 - Chien, S. T1 - Temperature transition of human hemoglobin at body temperature: effects of calcium. Kelemen, C.; Chien, S.; Artmann, Gerhard Michael JF - Biophysical journal. 80 (2001), H. 6 Y1 - 2001 SN - 1542-0086 SP - 2622 EP - 2630 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Hueck, Isgard S. A1 - Rossiter, Katharine A1 - Schmid-Schönbein, Geert W. T1 - Fluid Shear Attenuates Endothelial Pseudopodia Formation into the Capillary Lumen / Hueck, Isgard S. ; Rossiter, Katharine ; Artman, Gerhard M. ; Schmid-Schönbein, Geert W. JF - Microcirculation. 15 (2008), H. 6 Y1 - 2008 SN - 1549-8719 SP - 531 EP - 542 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Hueck, I. S. A1 - Hollweg, H. G. A1 - Schmid-Schönbein, G. W. T1 - Chlorpromazine modulates the Morphological Macro- and Microstructure of Endothelial Cells. Hueck, I. S.; Hollweg, H. G.; Schmid-Schönbein, G. W.; Artmann, Gerhard Michael JF - American Journal of Physiology. Cell Physiology. 278 (2000), H. 5 Y1 - 2000 SN - 1522-1563 N1 - Zählung: C873- C878 SP - 873 EP - 878 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Hovav, T. A1 - Goldfarb, A. A1 - Yedgar, S. [u.a.] T1 - Enhanced adherence of beta-thalassaemic erythrocytes to endothelial cells. Hovav, T., Goldfarb, A.; Artmann, Gerhard Michael, Yedgar, S.; Barstein, G. JF - British Journal of Haematology. 106 (1999), H. 1 Y1 - 1999 SN - 1365-2141 SP - 178 EP - 181 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Grebe, R. A1 - Homrighausen, A. A1 - Wolff, H. A1 - [u.a.], T1 - Response of normal and diabetic erythrocytes to membrane deformation by chemical and mechanical forces. Artmann, Gerhard Michael; Grebe, R.; Homrighausen, A.; Wolff, H.; Teitel, P.; Schmid-Schönbein, H. JF - 12. Jahrestagung der Gesellschaft für Mikrozirkulation Y1 - 1988 SP - 196 EP - 200 PB - Karger [u.a.] CY - Basel [u.a.] ER - TY - JOUR A1 - Artmann, Gerhard A1 - Gorbatenkova, E. A. A1 - Panasenko, O. M. T1 - Hypochlorous acid and human blood low density lipoproteins modified by hypochlorous acid increase erythrocyte adhesion to endothelial cells. Gorbatenkova, E. A.; Artmann, Gerhard Michael; Panasenko, O. M. JF - Membrane and cell biology. 13 (2000), H. 4 Y1 - 2000 SN - 1023-6597 SP - 537 EP - 546 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Zerlin, Kay A1 - Maggakis-Kelemen, Christina A1 - Linder, Peter A1 - Porst, Dariusz A1 - Kayser, Peter A1 - Stadler, David A1 - Dikta, Gerhard A1 - Temiz Artmann, Aysegül T1 - Hemoglobin senses body temperature JF - European Biophysics Journal Y1 - 2009 SN - 0175-7571 VL - 38 IS - 5 SP - 589 EP - 600 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Linder, Peter A1 - Porst, Dariusz T1 - Mechanism of haemoglobin sensing body temperature JF - Tissue Engineering Part A. 14 (2008), H. 5 Y1 - 2008 SN - 1937-3341 N1 - TERMIS EU 2008 Porto Meeting June 22–26, 2008 Porto Congress Center–Alfândega Portugal SP - 754 EP - 754 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Bäumler, H. A1 - Voigt, A. A1 - Mitlöhner, R. [u.a.] T1 - Plastic behaviour of polyelectrolyte microcapsules derived from colloid templates. Bäumler, H., Artmann, Gerhard Michael; Voigt, A., Mitlöhner, R., Neu, B., Kiesewetter, H. JF - Journal of Microencapsulation. 17 (2000), H. 5 Y1 - 2000 SN - 1464-5246 SP - 651 EP - 655 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Burns, Laura A1 - Canaves, Jaume M. A1 - Temiz Artmann, Aysegül T1 - Circular dichroism spectra of human hemoglobin reveal a reversible structural transition at body temperature JF - European Biophysics Journal. 33 (2004), H. 6 Y1 - 2004 SN - 1432-1017 SP - 490 EP - 496 ER - TY - JOUR A1 - Artmann, Gerhard T1 - A microscopic photometric method for measuring erythrocyte deformability. Artmann, Gerhard Michael JF - Clinical Hemorheology. 6 (1986) Y1 - 1986 SN - 0271-5198 SP - 617 EP - 627 ER -