TY - JOUR A1 - Jansen, Sebastian A1 - Behbahani, Mehdi A1 - Laumen, Marco A1 - Kaufmann, Tim A1 - Hormes, Marcus A1 - Schmitz-Rode, Thomas A1 - Behr, Marek A1 - Steinseifer, Ulrich T1 - 3D Stereo-PIV Validation for CFD-Simulation of Steady Flow through the Human Aorta using Rapid-Prototyping techniques Y1 - 2010 N1 - abstract ; IV International Symposium on Modelling of Physiological Flows, Sardinia, Italy, June 02-05, 2010 ; MPF2010 ER - TY - JOUR A1 - Brockhaus, Moritz K. A1 - Behbahani, Mehdi A1 - Muris, Farina A1 - Jansen, Sebastian V. A1 - Schmitz- Rode, Thomas A1 - Steinseifer, Ulrich A1 - Clauser, Johanna C. T1 - In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept JF - Artificial Organs N2 - Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential. Y1 - 2021 U6 - http://dx.doi.org/10.1111/aor.14046 SN - 1525-1594 VL - 45 IS - 12 SP - 1513 EP - 1521 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Steinseifer, Ulrich A1 - Kashefi, Ali A1 - Hormes, Marcus A1 - Schoberer, Mark A1 - Orlikowsky, Thorsten A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Schmitz-Rode, Thomas T1 - Miniaturization of ECMO Systems : Engineering Challenges and Methods JF - Artificial Organs. 33 (2009), H. 5 Y1 - 2009 SN - 1525-1594 N1 - Fifth International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion Abstracts SP - A55 EP - A55 ER -