TY - JOUR A1 - Ferrein, Alexander A1 - Jacobs, Stefan A1 - Lakemeyer, Gerhard T1 - Controlling Unreal Tournament 2004 Bots with the logic-based action language Golog / Jacobs, Stefan ; Ferrein, Alexander ; Lakemeyer, Gerhard JF - Proceedings of the First AAAI Conference on Artificial Intelligence and Interactive Digital Entertainment (AIIDE). Y1 - 2005 SP - 151 EP - 152 ER - TY - JOUR A1 - Bullerschen, Klaus-Gerd A1 - Wilhelmi, Herbert T1 - Cooling of arc furnace electrodes with heat pipes JF - Chemical Engineering & Technology. 14 (1991), H. 1 Y1 - 1991 SN - 0930-7516 SP - 45 EP - 53 ER - TY - JOUR A1 - Jacobs, Stephan A1 - Hermanns, Oliver T1 - Cooperative Design: Requirements on Network Technology and Document Architecture JF - Selected papers of the 6th Joint European Networking Conference / guest ed.: J. Barberá Y1 - 1996 N1 - Joint European Networking Conference <6, 1995, Tel Aviv>; Computer networks and ISDN systems ; 28,4 : special issue PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Hennemann, Jörg A1 - Kohl, Claus-Dieter A1 - Reisert, Steffen A1 - Kirchner, Patrick A1 - Schöning, Michael Josef T1 - Copper oxide nanofibres for detection of hydrogen peroxide vapour at high concentrations JF - physica status solidi (a) N2 - We present a sensor concept based on copper(II)oxide (CuO) nanofibres for the detection of hydrogen peroxide (H2O2) vapour in the percent per volume (% v/v) range. The fibres were produced by using the electrospinning technique. To avoid water condensation in the pores, the fibres were initially modified by an exposure to H2S to get an enclosed surface. By a thermal treatment at 350 °C the fibres were oxidised back to CuO. Thereby, the visible pores disappear which was verified by SEM analysis. The fibres show a decrease of resistance with increasing H2O2 concentration which is due to the fact that hydrogen peroxide is an oxidising gas and CuO a p-type semiconductor. The sensor shows a change of resistance within the minute range to the exposure until the maximum concentration of 6.9% v/v H2O2. At operating temperatures below 450 °C the corresponding sensor response to a concentration of 4.1% v/v increases. The sensor shows a good reproducibility of the signal at different measurements. CuO seems to be a suitable candidate for the detection of H2O2 vapour at high concentrations. Resistance behaviour of the sensor under exposure to H2O2 vapours between 2.3 and 6.9% v/v at an operating temperature of 450 °C. Y1 - 2013 U6 - http://dx.doi.org/10.1002/pssa.201200775 SN - 1862-6319 VL - 210 IS - 5 SP - 859 EP - 863 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Mourzina, Y. G. A1 - Schöning, Michael Josef A1 - Schubert, J. A1 - Zander, W. A1 - Legin, A. V. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Copper, cadmium and thallium thin film sensors based on chalcogenide glasses JF - Analytica Chimica Acta. 433 (2001) Y1 - 2001 SN - 0378-4304 SP - 103 EP - 110 ER - TY - JOUR A1 - Hartung, Frank A1 - Girod, Bernd T1 - Copyright protection in video delivery networks by watermarking of pre-compressed video / Hartung, Frank ; Girod, Bernd JF - Multimedia Applications, Services and Techniques - EMAST ´97 : Second European Conference Milan, Italy, May 21-23, 1997 Proceedings / Fdida, Serge ; Morganti, Michele Y1 - 1997 N1 - Lecture Notes in Computer Science ; 1242 SP - 423 EP - 436 PB - Springer CY - Berlin ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, G. A1 - Falk, R. A1 - Crookshank, M. T1 - Corrigendum to “Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration”. Baroud, G.; Falk, R.; Crookshank, M.; Sponagel, S.; Steffen, T. JF - Journal of Biomechanics. 37 (2004), H. 2 Y1 - 2004 SN - 0021-9290 SP - 1802 ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716–722] JF - Journals of Biomechanics Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiomech.2018.02.001 SN - 0021-9290 N1 - refers to Journal of Biomechanics Vol 47, Issue 3, Pages 716-722: https://doi.org/10.1016/j.jbiomech.2013.11.021 SP - 313 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wolisz, Henryk A1 - Schütz, Thomas A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Kohrn, Markus A1 - Wesseling, Mark A1 - Müller, Dirk T1 - Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets JF - Energy Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.energy.2017.06.025 VL - 137 SP - 715 EP - 728 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alnemer, Momin Sami Mohammad A1 - Kotliar, Konstantin A1 - Neuhaus, Valentin A1 - Pape, Hans-Christoph A1 - Ciritsis, Bernhard D. T1 - Cost-effectiveness analysis of surgical proximal femur fracture prevention in elderly: a Markov cohort simulation model JF - Cost Effectiveness and Resource Allocation N2 - Background Hip fractures are a common and costly health problem, resulting in significant morbidity and mortality, as well as high costs for healthcare systems, especially for the elderly. Implementing surgical preventive strategies has the potential to improve the quality of life and reduce the burden on healthcare resources, particularly in the long term. However, there are currently limited guidelines for standardizing hip fracture prophylaxis practices. Methods This study used a cost-effectiveness analysis with a finite-state Markov model and cohort simulation to evaluate the primary and secondary surgical prevention of hip fractures in the elderly. Patients aged 60 to 90 years were simulated in two different models (A and B) to assess prevention at different levels. Model A assumed prophylaxis was performed during the fracture operation on the contralateral side, while Model B included individuals with high fracture risk factors. Costs were obtained from the Centers for Medicare & Medicaid Services, and transition probabilities and health state utilities were derived from available literature. The baseline assumption was a 10% reduction in fracture risk after prophylaxis. A sensitivity analysis was also conducted to assess the reliability and variability of the results. Results With a 10% fracture risk reduction, model A costs between $8,850 and $46,940 per quality-adjusted life-year ($/QALY). Additionally, it proved most cost-effective in the age range between 61 and 81 years. The sensitivity analysis established that a reduction of ≥ 2.8% is needed for prophylaxis to be definitely cost-effective. The cost-effectiveness at the secondary prevention level was most sensitive to the cost of the contralateral side’s prophylaxis, the patient’s age, and fracture treatment cost. For high-risk patients with no fracture history, the cost-effectiveness of a preventive strategy depends on their risk profile. In the baseline analysis, the incremental cost-effectiveness ratio at the primary prevention level varied between $11,000/QALY and $74,000/QALY, which is below the defined willingness to pay threshold. Conclusion Due to the high cost of hip fracture treatment and its increased morbidity, surgical prophylaxis strategies have demonstrated that they can significantly relieve the healthcare system. Various key assumptions facilitated the modeling, allowing for adequate room for uncertainty. Further research is needed to evaluate health-state-associated risks. KW - Hip fractures KW - Prevention KW - Geriatric KW - Cost-effectiveness KW - Prophylaxis Y1 - 2023 U6 - http://dx.doi.org/10.1186/s12962-023-00482-4 SN - 1478-7547 N1 - Corresponding author: Momin S. Alnemer IS - 21, Article number: 77 PB - Springer Nature ER - TY - JOUR A1 - Martin, S. A. A1 - Berg, G. P. A. A1 - Hacker, U. A1 - Hardt, Arno A1 - Köhler, M. A1 - Meißburger, J. A1 - Osterfeld, F. A1 - Prasuhn, D. A1 - Riepe, G. A1 - Rogge, M. A1 - Schult, O. W. B. A1 - Speth, J. A1 - Turek, P. A1 - Gaul, G. A1 - Hagedoorn, H. A1 - Heide, J. A. van der A1 - Hinterberger, F. A1 - Huber, M. A1 - Jahn, R. A1 - Mayer-Kuckuk, T. A1 - Poth, H. A1 - Paetz gen. Schieck, H. T1 - COSY - a cooler synchrotron and storage ring JF - IEEE transactions on nuclear science. Vol. 32, iss. 5 Y1 - 1985 SN - 1558-1578 (E-Journal); 0018-9499 (Print) SP - 2694 EP - 2696 ER - TY - JOUR A1 - Krämer, Melina A1 - Pita, Marcos A1 - Zhou, Jian A1 - Ornatska, Maryna A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny T1 - Coupling of Biocomputing Systems with Electronic Chips: Electronic Interface for Transduction of Biochemical Information JF - Journal of Physical Chemistry C: Nanomaterials and Interfaces. 113 (2009), H. 6 Y1 - 2009 SN - 1932-7455 SP - 2573 EP - 2579 PB - American Cemical Society CY - Washington, DC ER - TY - JOUR A1 - Molinnus, Denise A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Coupling of Biomolecular Logic Gates with Electronic Transducers: From Single Enzyme Logic Gates to Sense/Act/Treat Chips JF - Electroanalysis N2 - The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor. Y1 - 2017 U6 - http://dx.doi.org/10.1002/elan.201700208 SN - 1521-4109 VL - 29 IS - 8 SP - 1840 EP - 1849 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Schroth, P. A1 - Schöning, Michael Josef A1 - Schütz, S. A1 - Malkoc, Ü. A1 - Steffen, A. A1 - Marso, M. A1 - Hummel, Hans E. A1 - Kordos, P. A1 - Lüth, H. T1 - Coupling of insect antennae to field-effect transistors for biochemical sensing JF - Electrochimica Acta. 44 (1999), H. 21-22 Y1 - 1999 SN - 0013-4686 SP - 3821 EP - 3826 ER - TY - JOUR A1 - Gaigall, Daniel A1 - Gerstenberg, Julian T1 - Cramér-von-Mises tests for the distribution of the excess over a confidence level JF - Journal of Nonparametric Statistics N2 - The Cramér-von-Mises distance is applied to the distribution of the excess over a confidence level. Asymptotics of related statistics are investigated, and it is seen that the obtained limit distributions differ from the classical ones. For that reason, quantiles of the new limit distributions are given and new bootstrap techniques for approximation purposes are introduced and justified. The results motivate new one-sample goodness-of-fit tests for the distribution of the excess over a confidence level and a new confidence interval for the related fitting error. Simulation studies investigate size and power of the tests as well as coverage probabilities of the confidence interval in the finite sample case. A practice-oriented application of the Cramér-von-Mises tests is the determination of an appropriate confidence level for the fitting approach. The adoption of the idea to the well-known problem of threshold detection in the context of peaks over threshold modelling is sketched and illustrated by data examples. KW - Cramér-von-Mises test KW - conditional excess distribution KW - confidence interval KW - goodness-of-fit test Y1 - 2023 U6 - http://dx.doi.org/10.1080/10485252.2023.2173958 SN - 1048-5252 (Print) SN - 1029-0311 (Online) PB - Taylor & Francis ER - TY - JOUR A1 - Chen, Bixia A1 - Schoemberg, Tobias A1 - Kraff, Oliver A1 - Dammann, Philipp A1 - Bitz, Andreas A1 - Schlamann, Marc A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Sure, Ulrich A1 - Wrede, Karsten H. T1 - Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study JF - Magnetic Resonance Materials in Physics, Biology and Medicine N2 - Objective This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation. Materials and methods The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T₁-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T₂-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading. Results Minor artifacts occurred around the CFPs in MPRAGE and T2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T. Conclusion Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s10334-016-0548-1 SN - 1352-8661 VL - 29 IS - 3 SP - 389 EP - 398 PB - Springer CY - Berlin ER - TY - JOUR A1 - Enning, Manfred A1 - Stützle, Thorsten A1 - Viereck, Uwe A1 - Stribersky, Anton T1 - Creepage control for use in wheelslide protection systems / Stützle, Thorsten ; Viereck, Uwe ; Stribersky, Anton ; Rulka, Wolfgang ; Enning, Manfred ; Abel, Dirk JF - Control in transportation systems : proceedings of the 11th IFAC symposium on control in transportation systems (CTS 2006), August 29-31, 2006, Delft, the Netherlands / International Federation of Automatic Control Y1 - 2006 SN - 0742-5953 ER - TY - JOUR A1 - Tillmann, K. A1 - Förster, Arnold T1 - Critical dimensions for the formation of interfacial misfit dislocations of In0.6Ga0.4As islands on GaAs(001) JF - Thin Solid Films. 368 (2000), H. 1 Y1 - 2000 SN - 0040-6090 SP - 93 EP - 104 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Schmitt, W. A1 - Güntherodt, G. A1 - Gambino, R. J. T1 - CrO2—A New Half-Metallic Ferromagnet? Kämper, K.-P.; Schmitt, W.; Güntherodt, G.; Gambino, R. J., Ruf, R. JF - Physical Review Letters. 59 (1987), H. 24 Y1 - 1987 SN - 1079-7114 SP - 2788 EP - 2791 ER - TY - JOUR A1 - Rübbelke, Dirk A1 - Vögele, Stefan A1 - Grajewski, Matthias A1 - Zobel, Luzy T1 - Cross border adjustment mechanism: Initial data for the assessment of hydrogen-based steel production JF - Data in Brief N2 - Ambitious climate targets affect the competitiveness of industries in the international market. To prevent such industries from moving to other countries in the wake of increased climate protection efforts, cost adjustments may become necessary. Their design requires knowledge of country-specific production costs. Here, we present country-specific cost figures for different production routes of steel, paying particular attention to transportation costs. The data can be used in floor price models aiming to assess the competitiveness of different steel production routes in different countries (Rübbelke, 2022). KW - Energy-intensive industry KW - Steel industry KW - Competitiveness KW - Floor prices KW - Cross border adjustment mechanism Y1 - 2023 U6 - http://dx.doi.org/10.1016/j.dib.2023.108907 SN - 2352-3409 VL - 47 IS - Article 108907 SP - 1 EP - 5 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Lieder, R. M. A1 - Didelez, J. P. T1 - Cross sections and isomer ratios for ²¹¹,²¹² Po JF - Annual report 1977 / Institut für Kernphysik Kernforschungsanlage Jülich Y1 - 1978 N1 - Spezielle Berichte der Kernforschungsanlage Jülich ; 15 SP - 49 EP - 50 PB - Verlag des Forschungszentrums Jülich CY - Jülich ER - TY - JOUR A1 - Thust, M. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Naser, S. A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. - Vol 1. Y1 - 1999 SN - 90-76699-02-X N1 - Eurosensors <13, 1999, 's-Gravenhage> ; Eurosensors <13, 1999, The Hague> ; European Conference on Solid-State Transducers <13, 1999, The Hague> SP - 573 EP - 576 CY - The Hague, The Netherlands ER - TY - JOUR A1 - Poghossian, Arshak A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Sensors and Actuators B. 68 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 260 EP - 265 ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Lieder, R. M. A1 - Didelez, J. P. T1 - Crosssections and isomers ratios for ²¹¹,²¹² Po JF - Frühjahrstagung ... des Fachausschusses Kernphysik und Hochenergiephysik der DPG (Sektion A: Kernphysik) / Deutsche Physikalische Gesellschaft (1978) Y1 - 1978 SP - 949 PB - Physik-Verlag CY - Weinheim ER - TY - JOUR A1 - Thust, M. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Naser, S. A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Crosssensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. Vol 1. Y1 - 1999 SN - 90-76699-02-X N1 - Eurosensors ; (13, 1999, 's-Gravenhage) ; Eurosensors ; (13 : ; 1999.09.12-15 : ; The Hague) ; European Conference on Solid-State Transducers ; (13 : ; 1999.09.12-15 : ; The Hague) SP - 573 EP - 576 CY - The Hague, The Netherlands ER - TY - JOUR A1 - Förster, Arnold A1 - Verghese, S. A1 - Zamdmer, N. A1 - Hu, Qing T1 - Cryogenic picosecond sampling using fiber-coupled photoconductive switch / S. Verghese ; N. Zamdmer ; Qing Hu ; A. Förster JF - Applied physics letters. 70 (1997), H. 20 Y1 - 1997 SN - 0003-6951 N1 - ISSN der E-Ausg.: 1077-3118 SP - 2644 EP - 2646 ER - TY - JOUR A1 - Selmer, Thorsten A1 - Lukatela, G. A1 - Krauss, N. A1 - Theis, K. T1 - Crystal structure of human arylsulfatase A: the aldehyde function and the metal ion at the active site suggest a novel mechanism for sulfate ester hydrolysis / Lukatela, G. ; Krauss, N. ; Theis, K. ; Selmer, T. ; Gieselmann, V. ; Figura, K. von ; Saenger, JF - Biochemistry. 37 (1998), H. 11 Y1 - 1998 SP - 3654 EP - 3664 ER - TY - JOUR A1 - Hemmerling, H.-J. A1 - Merschenz-Quack, Angelika A1 - Wunderlich, H. T1 - Crystal structures of indeno[1,2-d]imidazoles. XIth European Crystallographic Meeting, Vienna 1988 JF - Zeitschrift für Kristallographie - Crystalline Materials Y1 - 1988 SN - 2196-7105 (E-Books); 2194-4946 (Print) VL - 185 IS - H. 1-4 SP - 256 ER - TY - JOUR A1 - Lauth, Jakob A1 - Hoelderich, W. A1 - Wagenblast, G. T1 - Crystalline zeolites containing indigo dyes JF - Zeolites. 15 (1995), H. 1 Y1 - 1995 SN - 0144-2449 SP - 86 ER - TY - JOUR A1 - Abbas, Karim A1 - Balc, Nicolae A1 - Bremen, Sebastian A1 - Skupin, Marco T1 - Crystallization and aging behavior of polyetheretherketone PEEK within rapid tooling and rubber molding JF - Journal of Manufacturing and Materials Processing N2 - In times of short product life cycles, additive manufacturing and rapid tooling are important methods to make tool development and manufacturing more efficient. High-performance polymers are the key to mold production for prototypes and small series. However, the high temperatures during vulcanization injection molding cause thermal aging and can impair service life. The extent to which the thermal stress over the entire process chain stresses the material and whether it leads to irreversible material aging is evaluated. To this end, a mold made of PEEK is fabricated using fused filament fabrication and examined for its potential application. The mold is heated to 200 ◦C, filled with rubber, and cured. A differential scanning calorimetry analysis of each process step illustrates the crystallization behavior and first indicates the material resistance. It shows distinct cold crystallization regions at a build chamber temperature of 90 ◦C. At an ambient temperature above Tg, crystallization of 30% is achieved, and cold crystallization no longer occurs. Additional tensile tests show a decrease in tensile strength after ten days of thermal aging. The steady decrease in recrystallization temperature indicates degradation of the additives. However, the tensile tests reveal steady embrittlement of the material due to increasing crosslinking. KW - additive manufacturing KW - fused filament fabrication KW - crystallization KW - polyetheretherketone KW - rapid tooling Y1 - 2022 U6 - http://dx.doi.org/10.3390/jmmp6050093 SN - 2504-4494 N1 - The article belongs to the Special Issue Advances in Injection Molding: Process, Materials and Applications VL - 6 IS - 5 SP - 1 EP - 12 PB - MDPI CY - Basel ER - TY - JOUR A1 - Benkner, Thorsten T1 - CS+: A Novel Self-Adaptive Slot Assignment Scheme for ATDMA JF - Mobile technology for the human race / 1996 IEEE 46th Vehicular Technology Conference, Atlanta, Georgia, USA, April 28 - May 1, 1996 Y1 - 1996 SN - 0-7803-3158-3 N1 - Vehicular Technology Conference <46, 1996, Atlanta, Ga.> PB - IEEE Service Center CY - Piscataway, NY ER - TY - JOUR A1 - Jacobs, Stephan T1 - CSCW for Requirements Engineering - Requirements Engineering for CSCW JF - Proceedings of the Third European Conference on Computer Supported Cooperative Work : 13 - 17 September 1993, Milan, Italy ; ECSCW ' 93 / ed. by Giorgio de Michelis ... Y1 - 1993 SN - 0-7923-2447-1 N1 - ECSCW <3, 1993, Milano> ; [Workshop "CSCW Tools and Technologies: Definging Research Agendas] PB - Kluwer CY - Dordrecht [u.a.] ER - TY - JOUR A1 - Biselli, Manfred A1 - Noll, Thomas A1 - Jelinek, Nanni A1 - Schmidt, Sebastian T1 - Cultivation of Hematopoietic Stem and Progenitor Cells: biochemical Engineering Aspects / Thomas Noll, Nanni Jelinek, Sebastian Schmidt, Manfred Biselli und Christian Wandrey JF - Tools and Applications of Biochemical Engineering Science Y1 - 2002 SN - 3-540-42250-1 N1 - Advances in Biochemical Engineering/Biotechnology. 74 SP - 111 EP - 128 PB - Springer CY - Berlin ER - TY - JOUR A1 - Biselli, Manfred A1 - Hilbert, U. A1 - Noll, T. T1 - Cultivation of Human HCMV Specific Lymphocytes – An Example for Adoptive Immunotherapy / Hilbert, U. ; Biselli, M. ; Noll, T. JF - Animal cell technology : from target to market ; Tylösand, Sweden, June 10 - 14, 2001 / ed. by E. Lindner-Olsson ... Y1 - 2001 SN - 1-4020-0264-5 N1 - Proceedings of the ... ESACT meeting ; 17 SP - 558 EP - 561 PB - Kluwer CY - Dordrecht ER - TY - JOUR A1 - Schnitzler, Thomas T1 - Cultivation of hybridoma cell line CF-10H5 (DSMZ ACC477) JF - Application notes / Sartorius stedim biotech Y1 - 2009 SP - 1 EP - 4 ER - TY - JOUR A1 - Heieis, Jule A1 - Böcker, Jonas A1 - D'Angelo, Olfa A1 - Mittag, Uwe A1 - Albracht, Kirsten A1 - Schönau, Eckhard A1 - Meyer, Andreas A1 - Voigtmann, Thomas A1 - Rittweger, Jörn T1 - Curvature of gastrocnemius muscle fascicles as function of muscle–tendon complex length and contraction in humans JF - Physiological Reports N2 - It has been shown that muscle fascicle curvature increases with increasing contraction level and decreasing muscle–tendon complex length. The analyses were done with limited examination windows concerning contraction level, muscle–tendon complex length, and/or intramuscular position of ultrasound imaging. With this study we aimed to investigate the correlation between fascicle arching and contraction, muscle–tendon complex length and their associated architectural parameters in gastrocnemius muscles to develop hypotheses concerning the fundamental mechanism of fascicle curving. Twelve participants were tested in five different positions (90°/105°*, 90°/90°*, 135°/90°*, 170°/90°*, and 170°/75°*; *knee/ankle angle). They performed isometric contractions at four different contraction levels (5%, 25%, 50%, and 75% of maximum voluntary contraction) in each position. Panoramic ultrasound images of gastrocnemius muscles were collected at rest and during constant contraction. Aponeuroses and fascicles were tracked in all ultrasound images and the parameters fascicle curvature, muscle–tendon complex strain, contraction level, pennation angle, fascicle length, fascicle strain, intramuscular position, sex and age group were analyzed by linear mixed effect models. Mean fascicle curvature of the medial gastrocnemius increased with contraction level (+5 m−1 from 0% to 100%; p = 0.006). Muscle–tendon complex length had no significant impact on mean fascicle curvature. Mean pennation angle (2.2 m−1 per 10°; p < 0.001), inverse mean fascicle length (20 m−1 per cm−1; p = 0.003), and mean fascicle strain (−0.07 m−1 per +10%; p = 0.004) correlated with mean fascicle curvature. Evidence has also been found for intermuscular, intramuscular, and sex-specific intramuscular differences of fascicle curving. Pennation angle and the inverse fascicle length show the highest predictive capacities for fascicle curving. Due to the strong correlations between pennation angle and fascicle curvature and the intramuscular pattern of curving we suggest for future studies to examine correlations between fascicle curvature and intramuscular fluid pressure. KW - biomechanics KW - connective tissue KW - physiology KW - ultrasound Y1 - 2023 U6 - http://dx.doi.org/10.14814/phy2.15739 SN - 2051-817X VL - 11 IS - 11 SP - e15739, Seite 1-11 PB - Wiley ER - TY - JOUR A1 - Pietsch, Wolfram T1 - Customer-Oriented Specification and Evaluation of IT Service Level Agreements JF - Software process improvement : Elektronische Ressource : 12th European conference ; proceedings / EuroSPI 2005, Budapest, Hungary, November 9 - 11, 2005. Ita Richardson ... (ed.) Y1 - 2005 SN - 3-540-30286-7 N1 - Lecture notes in computer science ; 3792 ; EuroSPI <12, 2005, Budapest> SP - 83 EP - 94 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Hellwig, Angelika A1 - Rautenbach, Dieter A1 - Volkmann, Lutz T1 - Cuts leaving components of given minimum order JF - Discrete mathematics Y1 - 2005 SN - 1872-681X (E-Journal); 0012-365X (Print) VL - Vol. 292 IS - Iss. 1-3 SP - 55 EP - 65 ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Bachmann, P.K. A1 - Lade, H. A1 - Leers, D. T1 - CVD Diamond Growth: Gas Compositions and Film Properties / P.K. Bachmann, H.J. Hagemann, H. Lade, D. Leers, D.U. Wiechert and H. Wilson JF - Advanced materials '94 : proceedings of the NIRIM International Symposium on Advanced Materials '94, Tsukuba, Japan, March 13 - 17, 1994 / National Institute for Research in Inorganic Materials. Ed. by M. Kamo ... Y1 - 1994 N1 - NIRIM International Symposium on Advanced Materials ; 1994 (Tsukuba) : 1994.03.13-17 SP - 115 EP - 120 PB - International Communications Specialists CY - Tokyo ER - TY - JOUR A1 - Staat, Manfred T1 - Cyclic plastic deformation tests to verify FEM-based shakedown analyses N2 - Fatigue analyses are conducted with the aim of verifying that thermal ratcheting is limited. To this end it is important to make a clear distintion between the shakedown range and the ratcheting range (continuing deformation). As part of an EU-supported research project, experiments were carried out using a 4-bar model. The experiment comprised a water-cooled internal tube, and three insulated heatable outer test bars. The system was subjected to alternating axial forces, superimposed with alternating temperatures at the outer bars. The test parameters were partly selected on the basis of previous shakedown analyses. During the test, temperatures and strains were measured as a function of time. The loads and the resulting stresses were confirmed on an ongoing basis during performance of the test, and after it. Different material models were applied for this incremental elasto-plastic analysis using the ANSYS program. The results of the simulation are used to verify the FEM-based shakedown analysis. KW - Materialermüdung KW - Einspielen KW - Materialermüdung KW - shakedown analyses KW - thermal ratcheting KW - fatigue analyses Y1 - 2001 ER - TY - JOUR A1 - Henderson, Colin J. A1 - Mclaughlin, Lesley A. A1 - Scheer, Nico A1 - Stanley, Lesley A. A1 - Wolf, C. Roland T1 - Cytochrome b5 Is a Major Determinant of Human Cytochrome P450 CYP2D6 and CYP3A4 Activity In Vivo s JF - Molecular Pharmacology Y1 - 2015 U6 - http://dx.doi.org/10.1124/mol.114.097394 SN - 1521-0111 VL - 87 IS - 4 SP - 733 EP - 739 PB - ASPET CY - Bethesda ER - TY - JOUR A1 - Ge, B. A1 - Meyer, T. A1 - Schöning, Michael Josef A1 - Wollenberger, U. A1 - Lisdat, F., T1 - Cytochrome c‘ from Chromatium vinosum on gold electrodes JF - Electrochemistry Communications. 2 (2000), H. 8 Y1 - 2000 SN - 1388-2481 SP - 557 EP - 561 ER - TY - JOUR A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Unruh, Tobias A1 - Büldt, Georg A1 - Zaccai, Guiseppe T1 - Cytoplasmic water and hydration layer dynamics in human red blood cells JF - Journal of the American Chemical Society. 50 (2008), H. 130 Y1 - 2008 SN - 1520-5126 SP - 16852 EP - 16853 ER - TY - JOUR A1 - Gerhardt, Hans Joachim A1 - Konrath, B. A1 - Lieb, R.-D. T1 - Das Drallrohr JF - HLH : Lüftung, Klima, Heizung, Sanitär, Gebäudetechnik. 56 (2005), H. 11 Y1 - 2005 SN - 1436-5103 N1 - 2. ISSN: 0017-9906 ; 3. ISSN: 1434-422X ; Zeitschrift unter 13 Z 739 in der Bibliothek SP - 91 EP - 95 ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. A1 - Kapadi, A. A1 - Liu, B. Y. H. T1 - Data Inversion by Simplex Minimization for the Electrical Aerosol Analyzer JF - Aerosol Science and Technology. 1 (1982), H. 1982 Y1 - 1982 SN - 0278-6826 SP - 136 EP - 146 ER - TY - JOUR A1 - Grotendorst, Johannes A1 - Kless, A. A1 - Dickhaus, T. A1 - Meyer, W. T1 - Data Mining in der pharmazeutischen Forschung und Entwicklung / Kless, A. ; Dickhaus, T. ; Meyer, W. ; Grotendorst, J. JF - LITUS - Laboratory IT User Service. 1 (2004) Y1 - 2004 SP - 20 EP - 21 ER - TY - JOUR A1 - Grotendorst, Johannes A1 - Kless, A. A1 - Eitrich, T. T1 - Data Mining in F & E / Kless, A. ; Eitrich, T. ; Meyer, W. ; Grotendorst, J. JF - BioWorld: Magazin für Molekularbiologische und Biotechnologische Applikationen. 9 (2004), H. 2 Y1 - 2004 SN - 1424-8514 SP - 22 EP - 23 ER - TY - JOUR A1 - Bialonski, Stephan A1 - Ansmann, Gerrit A1 - Kantz, Holger T1 - Data-driven prediction and prevention of extreme events in a spatially extended excitable system JF - Physical Review E Y1 - 2015 U6 - http://dx.doi.org/10.1103/PhysRevE.92.042910 SN - 2470-0053 VL - 92 IS - 4 SP - 042910 ER - TY - JOUR A1 - Feuerriegel, Uwe A1 - Klose, W. A1 - Sloboshanin, S. A1 - Goebel, H. [u.a.] T1 - Deactivation of a palladium-supported alumina catalyst by hydrogen sulfide during the oxidation of methane JF - Langmuir: the ACS journal of surfaces and colloids. 10 (1994), H. 10 Y1 - 1994 SN - 0743-74363 SP - 3567 EP - 3570 ER - TY - JOUR A1 - Hirschberg, Rainer T1 - Decentral pumps in heating systems - a new hydraulic approac JF - 1st International Rotating Equipment Conference - Pumps and Compressors, 9th Pump Users International Forum, 9. Internationales Pumpenanwenderforum, Final Report, Düsseldorf, DE, 28.-29. Oct, 2008 Y1 - 2008 SP - 1 EP - 10 PB - - ER -