TY - JOUR A1 - Morais, Paulo V. A1 - Suman, Pedro H. A1 - Schöning, Michael Josef A1 - Siqueira Junior, José R. A1 - Orlandi, Marcelo O. T1 - Layer-by-layer film based on Sn₃O₄ nanobelts as sensing units to detect heavy metals using a capacitive field-effect sensor platform JF - Chemosensors N2 - Lead and nickel, as heavy metals, are still used in industrial processes, and are classified as “environmental health hazards” due to their toxicity and polluting potential. The detection of heavy metals can prevent environmental pollution at toxic levels that are critical to human health. In this sense, the electrolyte–insulator–semiconductor (EIS) field-effect sensor is an attractive sensing platform concerning the fabrication of reusable and robust sensors to detect such substances. This study is aimed to fabricate a sensing unit on an EIS device based on Sn₃O₄ nanobelts embedded in a polyelectrolyte matrix of polyvinylpyrrolidone (PVP) and polyacrylic acid (PAA) using the layer-by-layer (LbL) technique. The EIS-Sn₃O₄ sensor exhibited enhanced electrochemical performance for detecting Pb²⁺ and Ni²⁺ ions, revealing a higher affinity for Pb²⁺ ions, with sensitivities of ca. 25.8 mV/decade and 2.4 mV/decade, respectively. Such results indicate that Sn₃O₄ nanobelts can contemplate a feasible proof-of-concept capacitive field-effect sensor for heavy metal detection, envisaging other future studies focusing on environmental monitoring. KW - Sn₃O₄ KW - nanobelts KW - field-effect sensor KW - LbL films KW - heavy metals Y1 - 2023 U6 - http://dx.doi.org/10.3390/chemosensors11080436 SN - 2227-9040 N1 - This article belongs to the Special Issue The Application of Electrochemical Sensors or Biosensors Based on Nanomaterials VL - 11 IS - 8 PB - MDPI CY - Basel ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Werner, Frederik A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors JF - Journal of Physical Chemistry C. 113 (2009), H. 33 Y1 - 2009 SN - 1932-7455 SP - 14765 EP - 14770 PB - American Chemical Society CY - Washington, DC ER - TY - JOUR A1 - Werner, Frederik A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Lateral resolution enhancement of pulse-driven light-addressable potentiometric sensor JF - Sensor and Actuators B: Chemical N2 - To study chemical and biological processes, spatially resolved determination of the concentrations of one or more analyte species is of distinct interest. With a light-addressable potentiometric sensor (LAPS), chemical images can be created, which visualize the concentration distribution above the sensor plate. One important challenge is to achieve a good lateral resolution in order to detect events that take place in a small and limited region. LAPS utilizes a focused light spot to address the measurement region. By moving this light spot along the semiconductor sensor plate, the concentration distribution can be observed. In this study, we show that utilizing a pulse as light excitation instead of a traditionally used continuously modulated light excitation, the lateral resolution can be improved by a factor of 6 or more. KW - Chemical images KW - LAPS KW - Light-addressable potentiometric sensor Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.snb.2017.02.057 SN - 0925-4005 VL - 248 SP - 961 EP - 965 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ermolenko, Y. E. A1 - Yoshinobu, T. A1 - Mourzina, Y. G. A1 - Vlasov, Y. G. A1 - Schöning, Michael Josef A1 - Iwasaki, H. T1 - Laserscanned transducer (LSST) as a multisensor system JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 457 EP - 462 ER - TY - JOUR A1 - Dantism, Shahriar A1 - Röhlen, Desiree A1 - Dahmen, Markus A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - LAPS-based monitoring of metabolic responses of bacterial cultures in a paper fermentation broth JF - Sensors and Actuators B: Chemical N2 - As an alternative renewable energy source, methane production in biogas plants is gaining more and more attention. Biomass in a bioreactor contains different types of microorganisms, which should be considered in terms of process-stability control. Metabolically inactive microorganisms within the fermentation process can lead to undesirable, time-consuming and cost-intensive interventions. Hence, monitoring of the cellular metabolism of bacterial populations in a fermentation broth is crucial to improve the biogas production, operation efficiency, and sustainability. In this work, the extracellular acidification of bacteria in a paper-fermentation broth is monitored after glucose uptake, utilizing a differential light-addressable potentiometric sensor (LAPS) system. The LAPS system is loaded with three different model microorganisms (Escherichia coli, Corynebacterium glutamicum, and Lactobacillus brevis) and the effect of the fermentation broth at different process stages on the metabolism of these bacteria is studied. In this way, different signal patterns related to the metabolic response of microorganisms can be identified. By means of calibration curves after glucose uptake, the overall extracellular acidification of bacterial populations within the fermentation process can be evaluated. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.snb.2020.128232 SN - 0925-4005 VL - 320 IS - Art. 128232 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. T1 - Labor für Chemo- und Biosensorik an der FH Aachen, Abt. Jülich – Mehr als nur studieren JF - Fachblatt Fachhochschule Aachen (2004) Y1 - 2004 SN - 1430-7707 SP - 18 EP - 19 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Label-free sensing of biomolecules with field-effect devices for clinical applications JF - Electroanalysis N2 - Among the variety of transducer concepts proposed for label-free detection of biomolecules, the semiconductor field-effect device (FED) is one of the most attractive platforms. As medical techniques continue to progress towards diagnostic and therapies based on biomarkers, the ability of FEDs for a label-free, fast and real-time detection of multiple pathogenic and physiologically relevant molecules with high specificity and sensitivity offers very promising prospects for their application in point-of-care and personalized medicine for an early diagnosis and treatment of diseases. The presented paper reviews recent advances and current trends in research and development of different FEDs for label-free, direct electrical detection of charged biomolecules by their intrinsic molecular charge. The authors are mainly focusing on the detection of the DNA hybridization event, antibody-antigen affinity reaction as well as clinically relevant biomolecules such as cardiac and cancer biomarkers. Y1 - 2014 U6 - http://dx.doi.org/10.1002/elan.201400073 SN - 1521-4109 (E-Journal); 1040-0397 (Print) VL - 26 IS - 6 SP - 1197 EP - 1213 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Poghossian, Arshak A1 - Bronder, Thomas A1 - Wu, Chunsheng A1 - Schöning, Michael Josef T1 - Label-free sensing of biomolecules by their intrinsic molecular charge using field-effect devices T2 - Semiconductor Micro- and Nanoelectonics : Proceedings of the tenth international conference, Yerevan, Armenia, September 11-13 Y1 - 2015 SN - 978-5-8084-1991-9 SP - 61 EP - 63 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Bronder, Thomas A1 - Scheja, S. A1 - Wu, Chunsheng A1 - Metzger-Boddien, C. A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Label-free Electrostatic Detection of DNA Amplification by PCR Using Capacitive Field-effect Devices T2 - Procedia Engineering N2 - A capacitive field-effect EIS (electrolyte-insulator-semiconductor) sensor modified with a positively charged weak polyelectrolyte of poly(allylamine hydrochloride) (PAH)/single-stranded probe DNA (ssDNA) bilayer has been used for a label-free electrostatic detection of pathogen-specific DNA amplification via polymerase chain reaction (PCR). The sensor is able to distinguish between positive and negative PCR solutions, to detect the existence of target DNA amplicons in PCR samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.proeng.2016.11.512 SN - 1877-7058 N1 - Proceedings of the 30th anniversary Eurosensors Conference – Eurosensors 2016, 4-7. Sepember 2016, Budapest, Hungary VL - Vol. 168 SP - 514 EP - 517 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wu, Chunsheng A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Bäcker, Matthias A1 - Schöning, Michael Josef T1 - Label-free electrical detection of DNA with a multi-spot LAPS: First step towards light-addressable DNA chips JF - Physica status solidi A : Applications and materials science N2 - A multi-spot (4 × 4 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure has been applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. Single-stranded probe ssDNA molecules (20 bases) were covalently immobilized onto the silanized SiO2 gate surface. The unspecific adsorption of mismatch ssDNA on the MLAPS gate surface was blocked by bovine serum albumin molecules. To reduce the screening effect and to achieve a high sensor signal, the measurements were performed in a low ionic-strength solution. The photocurrent–voltage (I–V) curves were simultaneously recorded on all 16 spots after each surface functionalization step. Large shifts of I–V curves of 25 mV were registered after the DNA immobilization and hybridization event. In contrast, a small potential shift (∼5 mV) was observed in case of mismatch ssDNA, revealing good specificity of the sensor. The obtained results demonstrate the potential of the MLAPS as promising transducer platform for the multi-spot label-free electrical detection of DNA molecules by their intrinsic molecular charge. Y1 - 2014 U6 - http://dx.doi.org/10.1002/pssa.201330442 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1423 EP - 1428 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Cherstvy, Andrey G. A1 - Pedraza, Angela M. A1 - Ingebrandt, Sven A1 - Schöning, Michael Josef T1 - Label-free electrical detection of DNA by means of field-effect nanoplate capacitors: Experiments and modeling JF - Physica Status Solidi (a) N2 - Label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization/denaturation by means of an array of individually addressable field-effect-based nanoplate silicon-on-insulator (SOI) capacitors modified with gold nanoparticles (Au-NP) is investigated. The proposed device detects charge changes on Au-NP/DNA hybrids induced by the hybridization or denaturation event. DNA hybridization was performed in a high ionic-strength solution to provide a high hybridization efficiency. On the other hand, to reduce the screening of the DNA charge by counter ions and to achieve a high sensitivity, the sensor signal induced by the hybridization and denaturation events was measured in a low ionic-strength solution. High sensor signals of about 120, 90, and 80 mV were registered after the DNA hybridization, denaturation, and re-hybridization events, respectively. Fluorescence microscopy has been applied as reference method to verify the DNA immobilization, hybridization, and denaturation processes. An electrostatic charge-plane model for potential changes at the gate surface of a nanoplate field-effect sensor induced by the DNA hybridization has been developed taking into account both the Debye length and the distance of the DNA charge from the gate surface. Y1 - 2012 U6 - http://dx.doi.org/10.1002/pssa.201100710 SN - 1862-6319 VL - 209 SP - 925 EP - 934 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Pedraza, A. M. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Label-free DNA hybridization and denaturation detection by means of field-effect nanoplate SOI capacitors functionalized with gold nanoparticles JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Proc. Eurosensors XXIV, September 5–8, 2010, Linz, Austria SP - 918 EP - 921 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Bronder, Thomas A1 - Wu, Chunsheng A1 - Scheja, Sabrina A1 - Jessing, Max A1 - Metzger-Boddien, Christoph A1 - Keusgen, Michael A1 - Poghossian, Arshak T1 - Label-Free DNA Detection with Capacitive Field-Effect Devices—Challenges and Opportunities JF - Proceedings N2 - Field-effect EIS (electrolyte-insulator-semiconductor) sensors modified with a positively charged weak polyelectrolyte layer have been applied for the electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge. The EIS sensors are able to detect the existence of target DNA amplicons in PCR (polymerase chain reaction) samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process. Due to their miniaturized setup, compatibility with advanced micro- and nanotechnologies, and ability to detect biomolecules by their intrinsic molecular charge, those sensors can serve as possible platform for the development of label-free DNA chips. Possible application fields as well as challenges and limitations will be discussed. Y1 - 2017 U6 - http://dx.doi.org/10.3390/proceedings1080719 SN - 2504-3900 N1 - This article belongs to the Proceedings of "Proceedings of the 5th International Symposium on Sensor Science (I3S 2017)" VL - 1 IS - 8 SP - Artikel 719 PB - MDPI CY - Basel ER - TY - JOUR A1 - Ingebrandt, S. A1 - Han, Y. A1 - Nakamura, F. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Offenhäusser, A. T1 - Label-free detection of single nucleotide polymorphisms utilizing the differential transfer function of field-effect transistors JF - Biosensors and Bioelectronics. 22 (2007), H. 12 Y1 - 2007 SN - 0956-5663 SP - 2834 EP - 2840 ER - TY - JOUR A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Label-free detection of double-stranded DNA molecules with polyelectrolyte-modified capacitive field-effect sensors T1 - Markierungsfreie Detektion doppelsträngiger DNA Moleküle mit Hilfe von Polyelektrolyt-modifizierten kapazitiven Feldeffekt-Sensoren JF - tm - Technisches Messen N2 - In this study, polyelectrolyte-modified field-effect-based electrolyte-insulator-semiconductor (EIS) devices have been used for the label-free electrical detection of double-stranded deoxyribonucleic acid (dsDNA)molecules. The sensor-chip functionalization with a positively charged polyelectrolyte layer provides the possibility of direct adsorptive binding of negatively charged target DNA oligonucleotides onto theSiO2-chip surface.EIS sensors can be utilized as a tool to detect surface-charge changes; the electrostatic adsorption of oligonucleotides onto the polyelectrolyte layer leads to a measureable surface-potential change. Signals of 39mV have been recorded after the incubation with the oligonucleotide solution. Besides the electrochemical experiments, the successful adsorption of dsDNA onto the polyelectrolyte layer has been verified via fluorescence microscopy. The presented results demonstrate that the signal recording of EISchips, which are modified with a polyelectrolyte layer, canbe used as a favorable approach for a fast, cheap and simple detection method for dsDNA. Y1 - 2017 U6 - http://dx.doi.org/10.1515/teme-2017-0015 VL - 84 IS - 10 SP - 628 EP - 634 PB - De Gruyter CY - Oldenbourg ER - TY - JOUR A1 - Wu, Chunsheng A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Schöning, Michael Josef T1 - Label-free detection of DNA using light-addressable potentiometric sensor modified with a positively charged polyelectrolyte layer JF - Nanoscale N2 - A multi-spot (16 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure modified with a weak polyelectrolyte layer of PAH (poly(allylamine hydrochloride)) was applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. To achieve a preferentially flat orientation of DNA strands and thus, to reduce the distance between the DNA charge and MLAPS surface, the negatively charged probe single-stranded DNAs (ssDNA) were electrostatically adsorbed onto the positively charged PAH layer using a simple layer-by-layer (LbL) technique. In this way, more DNA charge can be positioned within the Debye length, yielding a higher sensor signal. The surface potential changes in each spot induced due to the surface modification steps (PAH adsorption, probe ssDNA immobilization, hybridization with complementary target DNA (cDNA), non-specific adsorption of mismatched ssDNA) were determined from the shifts of photocurrent–voltage curves along the voltage axis. A high sensor signal of 83 mV was registered after immobilization of probe ssDNA onto the PAH layer. The hybridization signal increases from 5 mV to 32 mV with increasing the concentration of cDNA from 0.1 nM to 5 μM. In contrast, a small signal of 5 mV was recorded in the case of non-specific adsorption of fully mismatched ssDNA (5 μM). The obtained results demonstrate the potential of the MLAPS in combination with the simple and rapid LbL immobilization technique as a promising platform for the future development of multi-spot light-addressable label-free DNA chips with direct electrical readout. Y1 - 2015 U6 - http://dx.doi.org/10.1039/C4NR07225A VL - 14 IS - 7 SP - 6143 EP - 6150 PB - Royal Society of Chemistry (RSC) CY - Cambridge ER - TY - JOUR A1 - Bronder, Thomas A1 - Wu, Chunsheng A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Label-free detection of DNA hybridization with light-addressable potentiometric sensors: comparison of various DNA-immobilization strategies JF - Procedia Engineering N2 - Light-addressable potentiometric sensors (LAPS) consisting of a p-Si-SiO2 and p-Si-SiO2-Au structure, respectively, have been tested for a label-free electrical detection of DNA (deoxyribonucleic acid) hybridization. Three different strategies for immobilizing single-stranded probe DNA (ssDNA) molecules on a LAPS surface have been studied and compared: (a) immobilization of thiol-modified ssDNA on the patterned Au surface via gold-thiol bond, (b) covalent immobilization of amino-modified ssDNA onto the SiO2 surface functionalized with 3-aminopropyltriethoxysilane and (c) layer-by-layer adsorption of negatively charged ssDNA on a positively charged weak polyelectrolyte layer of poly(allylamine hydrochloride). KW - LAPS KW - lable-free detection KW - DNA hybridization KW - field-effect sensor Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.proeng.2014.11.647 SN - 1877-7058 N1 - EUROSENSORS 2014 ; European Conference on Solid-State Transducers <28, 2014> VL - 87 SP - 755 EP - 758 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Abouzar, Maryam H. A1 - Schöning, Michael Josef T1 - Label-free detection of charged macromolecules by using a field-effect-based sensor platform: Experiments and possible mechanisms of signal generation JF - Applied Physics A: Materials Science & Processing. 87 (2007), H. 3 Y1 - 2007 SN - 0947-8396 N1 - Special Issue “From Surface Science to Nanoscale Devices” SP - 517 EP - 524 ER - TY - BOOK A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Label-free biosensing: advanced materials, devices and applications Y1 - 2018 SN - 978-3-319-75219-8 PB - Springer CY - Cham ER - TY - JOUR A1 - Schmitt, G. A1 - Faßbender, F. A1 - Lüth, H. A1 - Schöning, Michael Josef A1 - Buss, G. A1 - Kranzmann, A. A1 - Gramberg, U. T1 - Korrosionsschutzwirkung von Passivierungsschichten am Beispiel eines Mikroelektrodenarrays JF - Werkstoffe für die Energietechnik / Symposium 3 Y1 - 1999 SN - 3-527-29940-8 N1 - Serie Werkstoffwoche '98 ; 3 SP - 345 EP - 350 PB - Wiley-VCH CY - Weinheim [u.a.] ER - TY - CHAP A1 - Werner, Frederik A1 - Mansour, Ahmed A1 - Rateike, Franz-Matthias A1 - Schusser, Sebastian A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Keusgen, Michael A1 - Schöning, Michael Josef ED - Gerlach, Gerald T1 - Kompakter Aufbau eines lichtadressierbaren potentiometrischen Sensors mit verfahrbarem Diodenlaser T2 - 10. Dresdner Sensor-Symposium : Dresden, 5. - 7. Dezember 2011 ; miniaturisierte analytische Verfahren, Hochtemperatur-Sensoren, Sensoren für Bioprozess- und Verfahrenstechnik, Sensoren für die Medizin, Chemische Verfahrenstechnik, Lebensmittelanalytik, innovative Sensorlösungen, Sensoren für die Wasserqualität, Selbstüberwachung / Gerald Gerlach ... (Hg.) Dresdner Beiträge zur Sensorik. 43 Y1 - 2011 SN - 978-3-942710-53-4 SP - 277 EP - 280 PB - TUDpress CY - Dresden ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Jünger, M. A1 - Keusgen, M. T1 - Knoblauchgehaltsbestimmungen mit einem feldeffektbasierten Halbleiterbiosensor JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 707 EP - 714 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Thust, M. A1 - Steffen, A. A1 - Müller-Veggian, Mattea T1 - Kapazitives Sensorarray in Siliziumtechnik für die Prozeßüberwachung JF - ITG-Fachbericht. 148 (1998) Y1 - 1998 SN - 0341-0196 SP - 257 EP - 263 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Steffen, A. A1 - Sanke, M. S. A1 - Müller-Veggian, Mattea T1 - Kapazitiver Silizium-Sensor als Ph-Transducer für Biosensoranwendungen JF - 13. Jahrestagung der Biotechnologen : Wiesbaden 30.05. - 01.06.1995 / Deutsche Gesellschaft für Chemisches Apparatewesen, Chemische Technik und Biotechnologie e.V., Frankfurt am Main. - Bd. 1 Y1 - 1995 N1 - Jahrestagung der Biotechnologen <13, 1995, Wiesbaden> ; Deutsche Gesellschaft für Chemisches Apparatewesen, Chemische Technik und Biotechnologie SP - 65 EP - 66 PB - DECHEMA CY - Frankfurt am Main ER - TY - CHAP A1 - Oberländer, Jan A1 - Reisert, Steffen A1 - Kirchner, Patrick A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Kalorimetrische Gassensoren zur H2O2-Detektion in aseptischen Sterilisationsprozessen T2 - 11. Dresdner Sensor-Symposium : 9.-11.12.2013 Y1 - 2013 SN - 978-3-9813484-5-3 SP - 234 EP - 238 ER - TY - JOUR A1 - Mourzina, Y. A1 - Mai, T. A1 - Poghossian, Arshak A1 - Ermolenko, Y. A1 - Yoshinobu, T. A1 - Vlasov, Y. A1 - Iwasaki, H. A1 - Schöning, Michael Josef T1 - K+-selective field-effect sensors as transducers for bioelectronic applications JF - Electrochimica Acta. 48 (2003), H. 20-22 Y1 - 2003 SN - 0013-4686 SP - 3333 EP - 3339 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Sauke, M. A1 - Steffen, A. A1 - Marso, M. (u.a.) T1 - Ion-sensitive field-effect transistors with ultrathin Langmuir-Blodgett membranes JF - Sensors and Actuators B. 27 (1995), H. 1-3 Y1 - 1995 SN - 0925-4005 SP - 325 EP - 328 ER - TY - CHAP A1 - Beging, Stefan A1 - Poghossian, Arshak A1 - Mlynek, D. A1 - Hataihimakul, S. A1 - Pedraza, A. A1 - Dhawan, S. A1 - Laube, N. A1 - Kleinen, L. A1 - Baldsiefen, G. A1 - Busch, H. A1 - Schöning, Michael Josef T1 - Ion-selective sensors for the determination of the risk of urinary stone formation T2 - Micro- and Nanosystems in biochemical diagnosis : Principles and applications Y1 - 2010 SP - 74 EP - 80 CY - Warsaw ER - TY - JOUR A1 - Mourzina, Y. G. A1 - Yoshinobu, T. A1 - Schubert, J. A1 - Lüth, H. A1 - Iwasaki, H. A1 - Schöning, Michael Josef T1 - Ion-selective lightaddressable potentiometric sensor (LAPS) with chalcogenide thin film by pulsed laser deposition JF - Sensors and Actuators B. 80 (2001), H. 2 Y1 - 2001 SN - 0925-4005 SP - 136 EP - 140 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Bruns, M. A1 - Hoffmann, W. A1 - Hoffmann, B. (u.a.) T1 - Iodide ion-sensitive field-effect structures JF - Sensors and Actuators B. 15 (1993), H. 1-3 Y1 - 1993 SN - 0925-4005 SP - 192 EP - 194 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Crott, M. A1 - Ronkel, F. A1 - Thust, M. A1 - Schultze, J. W. A1 - Kordos, P. A1 - Lüth, H. T1 - Investigations on porous silicon layers with regard to chemical microsensor applications JF - Third International Conference on Intelligent Materials : Lyon, 3-4-5 June 1996, Center of Congress "L'Espace Tête d'Or" / [publ. by SPIE, the International Society for Optical Engineering]. General chair/ed. by: P. F. Gobin Y1 - 1996 SN - 0819421650 N1 - International Conference on Intelligent Materials ; (3, 1996, Lyon) SP - 275 EP - 280 PB - SPIE CY - Bellingham, Wash. ER - TY - JOUR A1 - Breuer, Lars A1 - Mang, Thomas A1 - Schöning, Michael Josef A1 - Thoelen, Ronald A1 - Wagner, Torsten T1 - Investigation of the spatial resolution of a laser-based stimulation process for light-addressable hydrogels with incorporated graphene oxide by means of IR thermography JF - Sensors and Actuators A: Physical Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.sna.2017.11.031 SN - 0924-4247 VL - 268 SP - 126 EP - 132 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ismail, A.B.M. A1 - Harada, T. A1 - Yoshinobu, T. A1 - Iwasaki, H. A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Investigation of pulsed laser-deposited Al2O3 as a high pH-sensitive layer for LAPS-based biosensing applications JF - Sensors and Actuators B. 71 (2000), H. 3 Y1 - 2000 SN - 0925-4005 SP - 169 EP - 172 ER - TY - JOUR A1 - Näther, Niko A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schöning, Michael Josef T1 - Investigation of different catalytically active and passive materials for realising a hydrogen peroxide gas sensor JF - physica status solidi (a) . 206 (2009), H. 3 Y1 - 2009 SN - 1862-6319 N1 - Special Issue: Engineering of Functional Interfaces (EnFI 08) SP - 449 EP - 454 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Poghossian, Arshak A1 - Krämer, Melina A1 - Abouzar, Maryam H. A1 - Pita, Marcos A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Interfacing of biocomputing systems with silicon chips: Enzyme logic gates based on field-effect devices JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 682 EP - 685 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Malzahn, K. A1 - Abouzar, Maryam H. A1 - Mehndiratta, P. A1 - Katz, E. A1 - Schöning, Michael Josef T1 - Integration of biomolecular logic gates with field-effect transducers JF - Electrochimica Acta. 56 (2011), H. 26 Y1 - 2011 SN - 0013-4686 SP - 9661 EP - 9665 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Rolka, David A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Integration of a capacitive EIS sensor into a FIA system for pH and penicillin determination JF - Sensors. 4 (2004) Y1 - 2004 SN - 1424-8220 SP - 84 EP - 94 ER - TY - JOUR A1 - Schroth, P. A1 - Schöning, Michael Josef A1 - Kordos, P. A1 - Lüth, H. A1 - Schütz, S. A1 - Weißbecker, B. A1 - Hummel, Hans E. T1 - Insectbased BioFETs with improved signal characteristics JF - Biosensors & Bioelectronics. 14 (1999), H. 3 Y1 - 1999 SN - 0956-5663 SP - 303 EP - 308 ER - TY - JOUR A1 - Schütz, S. A1 - Czynski, J. A1 - Hummel, Hans E. A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Kordos, P. A1 - Lüth, H. T1 - Insect meets microelectronics: A BioFET as a first step to bioelectronic microsystems JF - Transducers '99 : proceedings of the Tenth International Conference on Solid-State Sensors and Actuators ; 7 - 10 June, 1999, Sendai, Japan / ed.: S. Middelhoek Y1 - 2000 N1 - International Conference on Solid State Sensors and Actuators <10, 1999, Sendai, Miyagi-ken> ; Transducers '99 ; (10 : ; 1999.06.07-10 : ; Sendai) SP - 1104 EP - 1107 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schroth, Peter A1 - Lüth, Hans A1 - Hummel, Hans E. A1 - Schütz, Stefan T1 - Insect chemoreceptors coupled to silicon transistors as innovative biosensors JF - Proceedings of SPIE. 4205 (2001) Y1 - 2001 SP - 152 EP - 162 ER - TY - JOUR A1 - Kloock, Joachim P. A1 - Mourzina, Y.G. A1 - Ermolenko, Y. A1 - Doll, T. A1 - Schubert, J. A1 - Schöning, Michael Josef T1 - Inorganic thin-film sensor membranes with PLD-prepared chalcogenide glasses: Challenges and implementation JF - Sensors. 4 (2004), H. 10 Y1 - 2004 SN - 1424-8220 SP - 156 EP - 162 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schubert, J A1 - Kloock, Joachim P. A1 - Zander, W. A1 - Mourzina, Y. G. A1 - Legin, A. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Innovative thin film techniques for microfabricating electrochemical sensors JF - Lecture Notes of the ICB Seminars Y1 - 2002 SP - 55 EP - 66 PB - MCB CY - Warsaw ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schubert, Joachim P. A1 - Kloock, Joachim P. A1 - Zander, W. A1 - Mourzina, Y. G. A1 - Legin, A. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Innovative thin film techniques for microfabricating electrochemical sensors JF - Biocybernetics and Biomedical Engineering. 21 (2001), H. 4 Y1 - 2001 SN - 0208-5216 SP - 107 EP - 119 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Yoshinobu, T. A1 - Schubert, J. A1 - Steffen, A. A1 - Lüth, H. T1 - Innovative Schichttechniken und Messprinzipien für kapazitive Feldeffektsensoren JF - Sensoren und Mess-Systeme : Vorträge der 11. ITG/GMA-Fachtagung vom 11. bis 12. März 2002 in Ludwigsburg / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ... Wiss. Tagungsleitung: C. D. Kohl .... Y1 - 2002 SN - 3-8007-2675-0 N1 - Sensoren und Mess-Systeme 2002 SP - 151 EP - 154 PB - VDE-Verl. CY - Berlin [u.a.] ER - TY - JOUR A1 - Hamad, E. M. A1 - Bilatto, S. E. R. A1 - Adly, N. Y. A1 - Correa, D. S. A1 - Wolfrum, B. A1 - Schöning, Michael Josef A1 - Offenhäusser, A. A1 - Yakushenko, A. T1 - Inkjet printing of UV-curable adhesive and dielectric inks for microfluidic devices JF - Lab on a Chip N2 - Bonding of polymer-based microfluidics to polymer substrates still poses a challenge for Lab-On-a-Chip applications. Especially, when sensing elements are incorporated, patterned deposition of adhesives with curing at ambient conditions is required. Here, we demonstrate a fabrication method for fully printed microfluidic systems with sensing elements using inkjet and stereolithographic 3D-printing. Y1 - 2016 U6 - http://dx.doi.org/10.1039/C5LC01195G SN - 1473-0189 VL - 16 IS - 1 SP - 70 EP - 74 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Bertz, Morten A1 - Schöning, Michael Josef A1 - Molinnus, Denise A1 - Homma, Takayuki T1 - Influence of temperature, light, and H₂O₂ concentration on microbial spore inactivation: in-situ Raman spectroscopy combined with optical trapping JF - Physica status solidi (a) applications and materials science N2 - To gain insight on chemical sterilization processes, the influence of temperature (up to 70 °C), intense green light, and hydrogen peroxide (H₂O₂) concentration (up to 30% in aqueous solution) on microbial spore inactivation is evaluated by in-situ Raman spectroscopy with an optical trap. Bacillus atrophaeus is utilized as a model organism. Individual spores are isolated and their chemical makeup is monitored under dynamically changing conditions (temperature, light, and H₂O₂ concentration) to mimic industrially relevant process parameters for sterilization in the field of aseptic food processing. While isolated spores in water are highly stable, even at elevated temperatures of 70 °C, exposure to H₂O₂ leads to a loss of spore integrity characterized by the release of the key spore biomarker dipicolinic acid (DPA) in a concentration-dependent manner, which indicates damage to the inner membrane of the spore. Intensive light or heat, both of which accelerate the decomposition of H₂O₂ into reactive oxygen species (ROS), drastically shorten the spore lifetime, suggesting the formation of ROS as a rate-limiting step during sterilization. It is concluded that Raman spectroscopy can deliver mechanistic insight into the mode of action of H₂O₂-based sterilization and reveal the individual contributions of different sterilization methods acting in tandem. KW - hydrogen peroxide KW - optical spore trapping KW - Raman spectroscopy KW - sterilization conditions KW - temperature Y1 - 2024 U6 - http://dx.doi.org/10.1002/pssa.202300866 SN - 1862-6319 (Online) SN - 1862-6300 (Print) IS - Early View PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Janus, Kevin Alexander A1 - Achtsnicht, Stefan A1 - Tempel, Laura A1 - Drinic, Aleksaner A1 - Kopp, Alexander A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Influence of fibroin membrane composition and curing parameters on the performance of a biodegradable enzymatic biosensor manufactured from Silicon-Free Carbon JF - Physica status solidi : pss. A, Applications and materials science N2 - Herein, fibroin, polylactide (PLA), and carbon are investigated for their suitability as biocompatible and biodegradable materials for amperometric biosensors. For this purpose, screen-printed carbon electrodes on the biodegradable substrates fibroin and PLA are modified with a glucose oxidase membrane and then encapsulated with the biocompatible material Ecoflex. The influence of different curing parameters of the carbon electrodes on the resulting biosensor characteristics is studied. The morphology of the electrodes is investigated by scanning electron microscopy, and the biosensor performance is examined by amperometric measurements of glucose (0.5–10 mM) in phosphate buffer solution, pH 7.4, at an applied potential of 1.2 V versus a Ag/AgCl reference electrode. Instead of Ecoflex, fibroin, PLA, and wound adhesive are tested as alternative encapsulation compounds: a series of swelling tests with different fibroin compositions, PLA, and Ecoflex has been performed before characterizing the most promising candidates by chronoamperometry. Therefore, the carbon electrodes are completely covered with the particular encapsulation material. Chronoamperometric measurements with H2O2 concentrations between 0.5 and 10 mM enable studying the leakage current behavior. KW - amperometric biosensors KW - biocompatible KW - biodegradabl KW - encapsulation materials KW - fibroin Y1 - 2023 U6 - http://dx.doi.org/10.1002/pssa.202300081 SN - 1862-6300 (Print) SN - 1862-6319 (Online) N1 - Corresponding author: Michael J. Schöning VL - 220 IS - 22 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Molinnus, Denise A1 - Beging, Stefan A1 - Schöning, Michael Josef T1 - Incorporating a hybrid urease-carbon nanotubes sensitive nanofilm on capacitive field-effect sensors for urea detection JF - Analytical chemistry N2 - The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor’s surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance–voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (∼18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform. Y1 - 2014 U6 - http://dx.doi.org/10.1021/ac500458s SN - 1520-6882 (E-Journal); 0003-2700 (Print); 0096-4484 (Print) VL - 86 IS - 11 SP - 5370 EP - 5375 PB - ACS Publications CY - Columbus ER - TY - JOUR A1 - Thust, M. A1 - Schroth, P. A1 - Töpler, A. A1 - Schöning, Michael Josef A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Improving the detection limit of a capacitive sensor by means of a diffusion barrier JF - Eurosensors XII : proceedings of the 12th European Conference on Solid-State Transducers and the 9th UK Conference on Sensors and their Applications, Southampton, UK, 13 - 16 September 1998 / ed. by N. M. White ; Vol. 1 Y1 - 1998 SN - 0-7503-0595-9 N1 - Eurosensors ; (12, 1998, Southampton) ; UK Conference on Sensors and Their Applications ; (9, 1998, Southampton) SP - 507 EP - 510 PB - Inst. of Physics Publ. CY - Bristol [u.a.] ER - TY - JOUR A1 - Schroth, P. A1 - Schöning, Michael Josef A1 - Schütz, S. A1 - Epanya, P. A1 - Steffen, A. A1 - Weißbecker, B. A1 - Hummel, Hans E. A1 - Kordos, P. A1 - Lüth, H. T1 - Improving the bioelectronic interface of an antenna/chip biosensor – technological aspects JF - Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. Vol 1. Y1 - 1999 SN - 90-76699-02-X N1 - Eurosensors ; (13, 1999, 's-Gravenhage) ; Eurosensors ; (13 : ; 1999.09.12-15 : ; The Hague) ; European Conference on Solid-State Transducers ; (13 : ; 1999.09.12-15 : ; The Hague) SP - 569 EP - 572 CY - The Hague, The Netherlands ER -