TY - JOUR A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Mosset, Jean-Baptiste A1 - Devroede, Olivier A1 - Krieguer, Magalie A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, Claudia A1 - Streun, Matthias A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Sempere-Roldan, P. A1 - Lecoq, Paul A1 - Bruyndonckx, Peter A1 - Loude, Jean-François A1 - Tavernier, Stefaan A1 - Morel, Christian T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Auffray, Etiennette A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Ziemons, Karl A1 - Achten, R. A1 - Auffray, Etiennette A1 - Müller-Veggian, Mattea T1 - The ClearPET™ neuro scanner: a dedicated LSO/LuYAP phoswich small animal PET scanner JF - 2004 IEEE Nuclear Science Symposium conference record : Nuclear Science Symposium, Medical Imaging Conference ; 16 - 22 October 2004, Rome, Italy ; [including the Symposium on Nuclear Power System (SNPS), 14th Room Temperature Semiconductor X- and Gamma-Ray Detectors Workshop and special focus workshops] / NPSS, Nuclear & Plasma Sciences Society. Guest ed.: J. Anthony Seibert Y1 - 2004 SN - 1082-3654 N1 - Nuclear Science Symposium Conference Record, 2004 IEEE SP - 2430 EP - 2433 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Akimbekov, Nuraly S. A1 - Digel, Ilya A1 - Tastambek, Kuanysh T. A1 - Kozhahmetova, Marzhan A1 - Sherelkhan, Dinara K. A1 - Tauanov, Zhandos T1 - Hydrogenotrophic methanogenesis in coal-bearing environments: Methane production, carbon sequestration, and hydrogen availability JF - International Journal of Hydrogen Energy N2 - Methane is a valuable energy source helping to mitigate the growing energy demand worldwide. However, as a potent greenhouse gas, it has also gained additional attention due to its environmental impacts. The biological production of methane is performed primarily hydrogenotrophically from H2 and CO2 by methanogenic archaea. Hydrogenotrophic methanogenesis also represents a great interest with respect to carbon re-cycling and H2 storage. The most significant carbon source, extremely rich in complex organic matter for microbial degradation and biogenic methane production, is coal. Although interest in enhanced microbial coalbed methane production is continuously increasing globally, limited knowledge exists regarding the exact origins of the coalbed methane and the associated microbial communities, including hydrogenotrophic methanogens. Here, we give an overview of hydrogenotrophic methanogens in coal beds and related environments in terms of their energy production mechanisms, unique metabolic pathways, and associated ecological functions. KW - Coal KW - Methanogenesis KW - Methane KW - Hydrogenotrophic methanogens KW - H2 Y1 - 2024 U6 - https://doi.org/10.1016/j.ijhydene.2023.09.223 SN - 1879-3487 (online) SN - 0360-3199 (print) VL - 52 IS - Part D SP - 1264 EP - 1277 PB - Elsevier CY - New York ER - TY - JOUR A1 - Grotendorst, Johannes A1 - Scott, Tony C. A1 - Aubert-Frécon, Monique A1 - Andrae, D. A1 - Morgan III, J. D. A1 - Glasser, M. L. T1 - Exchange Energy for Two-Active-Electron Diatomic Systems within the Surface Integral Method / Scott,T. C .; Aubert-Frécon, M. ; Andrae, D. ; Grotendorst, J. ; Morgan III, J. D. ; Glasser, M. L. JF - Applicable Algebra in Engineering, Communication and Computing. 15 (2004), H. 2 Y1 - 2004 SN - 0938-1279 N1 - zugl. Technical Report FZJ-ZAM-IB-2004-02, April 2004, 24 pages SP - 101 EP - 128 ER - TY - JOUR A1 - Lehnertz, Klaus A1 - Mormann, Florian A1 - Osterhage, Hannes A1 - Müller, Andy A1 - Prusseit, Jens A1 - Chernihovskyi, Anton A1 - Staniek, Matthäus A1 - Krug, Dieter A1 - Bialonski, Stephan A1 - Elger, Christian E. T1 - State-of-the-art of seizure prediction JF - Journal of Clinical Neurophysiology Y1 - 2007 U6 - https://doi.org/10.1097/WNP.0b013e3180336f16 SN - 1537-1603 VL - 24 IS - 2 SP - 147 EP - 153 ER - TY - JOUR A1 - Arida, Hassan A. A1 - Al-Haddad, Ameera A1 - Schöning, Michael Josef T1 - New Solid-State Organic Membrane Based Lead-Selective Micro-Electrode JF - International Journal of Electrochemical Science. 6 (2011), H. 9 Y1 - 2011 SN - 1452-3981 SP - 3858 EP - 3867 ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios A1 - Baltzopoulos, Vasilios T1 - Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo JF - Journal of Biomechanics Y1 - 2008 U6 - https://doi.org/10.1016/j.jbiomech.2008.04.020 SN - 0021-9290 VL - 41 SP - 2211 EP - 2218 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Jablonski, Melanie A1 - Koch, Claudia A1 - Bronder, Thomas A1 - Rolka, David A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Field-effect biosensor using virus particles as scaffolds for enzyme immobilization JF - Biosensors and Bioelectronics N2 - A field-effect biosensor employing tobacco mosaic virus (TMV) particles as scaffolds for enzyme immobilization is presented. Nanotubular TMV scaffolds allow a dense immobilization of precisely positioned enzymes with retained activity. To demonstrate feasibility of this new strategy, a penicillin sensor has been developed by coupling a penicillinase with virus particles as a model system. The developed field-effect penicillin biosensor consists of an Al-p-Si-SiO₂-Ta₂O₅-TMV structure and has been electrochemically characterized in buffer solutions containing different concentrations of penicillin G. In addition, the morphology of the biosensor surface with virus particles was characterized by scanning electron microscopy and atomic force microscopy methods. The sensors possessed a high penicillin sensitivity of ~ 92 mV/dec in a nearly-linear range from 0.1 mM to 10 mM, and a low detection limit of about 50 µM. The long-term stability of the penicillin biosensor was periodically tested over a time period of about one year without any significant loss of sensitivity. The biosensor has also been successfully applied for penicillin detection in bovine milk samples. Y1 - 2018 U6 - https://doi.org/10.1016/j.bios.2018.03.036 SN - 0956-5663 VL - 110 SP - 168 EP - 174 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bäcker, Matthias A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Multi-Parametererfassung mit siliziumbasiertem Sensorchip: Aus Drei mach Eins JF - GIT Labor-Fachzeitschrift Y1 - 2014 SN - 0016-3538 IS - 2 SP - 28 EP - 30 PB - Wiley ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Schultze, J. W. A1 - Lüth, H. T1 - Field-effect based multifunctional hybrid sensor module for the determination of both (bio-)chemical and physical paramters JF - Proceedings of SPIE. 4576 (2002) Y1 - 2002 SP - 149 EP - 159 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, L. A1 - Schöning, Michael Josef T1 - Chemical sensor as a physical sensor: ISFET-based flowvelocity, flow-direction and diffusion-coefficient sensor JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 649 EP - 652 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Näther, Niko A1 - Auger, V. A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - A miniaturized flow-through cell in SU-8 technique for EIS sensors JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 994 EP - 995 ER - TY - JOUR A1 - Ciobanu, Octavian A1 - Staat, Manfred A1 - Rahimi, Alireza T1 - The use of open source software in biomechanical finite element analysis JF - Buletinul Institutului Politehnic din Iaşi / Universitatea Tehnică Gh. Asachi, Iaşi Secţia 5, Construcţii de maşini = Machine construction = Bulletin of the Polytechnic Institute of Jassy = Izvestija Jasskogo Politechničeskogo Instituta Y1 - 2008 SN - 1011-2855 VL - 54 IS - 7/8 SP - 213 EP - 220 ER - TY - JOUR A1 - Buniatyan, V. A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Aroutiounian, V. M. A1 - Schöning, Michael Josef T1 - BaxSr1-x TiO3/pc-Si heterojunction capacitance JF - Armenian journal of physics Y1 - 2013 SN - 1829-1171 VL - 6 IS - 4 SP - 188 EP - 197 PB - National Academy of Sciences of Armenia CY - Yerevan ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Linder, Peter A1 - Kayser, Peter A1 - Digel, Ilya T1 - NMR in vitro effects on proliferation, apoptosis, and viability of human chondrocytes and osteoblasts JF - Methods and findings in Experimental and Clinical Pharmacology. 27 (2005), H. 6 Y1 - 2005 SN - 0379-0355 SP - 391 EP - 394 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Schultze, Joachim W. T1 - Measuring seven parameters by two ISFET modules in a microcell set-up JF - Int. Journal of Computational Engineering Science. 4 (2003), H. 2 Y1 - 2003 SN - 1465-8763 SP - 257 EP - 260 ER - TY - JOUR A1 - Pieronek, Lukas A1 - Kleefeld, Andreas T1 - On trajectories of complex-valued interior transmission eigenvalues JF - Inverse problems and imaging : IPI N2 - This paper investigates the interior transmission problem for homogeneous media via eigenvalue trajectories parameterized by the magnitude of the refractive index. In the case that the scatterer is the unit disk, we prove that there is a one-to-one correspondence between complex-valued interior transmission eigenvalue trajectories and Dirichlet eigenvalues of the Laplacian which turn out to be exactly the trajectorial limit points as the refractive index tends to infinity. For general simply-connected scatterers in two or three dimensions, a corresponding relation is still open, but further theoretical results and numerical studies indicate a similar connection. KW - Interior transmission problem KW - Eigenvalue trajectories KW - Complex-valued eigenvalues Y1 - 2024 U6 - https://doi.org/10.3934/ipi.2023041 SN - 1930-8337 (Print) SN - 1930-8345 (Online) VL - 18 IS - 2 SP - 480 EP - 516 PB - AIMS CY - Springfield, Mo ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Reisert, Steffen A1 - Kramer, Friederike A1 - Begoyan, Vardges K. A1 - Buniatyan, Vahe V. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing using high-k oxide of barium strontium titanate JF - Physica status solidi (a) N2 - High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed. Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431911 SN - 1862-6319 VL - 212 IS - 6 SP - 1259 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Bialonski, Stephan A1 - Lehnertz, Klaus T1 - Identifying phase synchronization clusters in spatially extended dynamical systems JF - Physical Review E Y1 - 2006 U6 - https://doi.org/10.1103/PhysRevE.74.051909 SN - 2470-0053 VL - 74 IS - 5 SP - 051909 ER - TY - JOUR A1 - Stulpe, Werner T1 - On the Representation of Quantum Mechanics on Phase Space JF - International Journal of Theoretical Physics. 31 (1992), H. 9 Y1 - 1992 SN - 1572-9575 SP - 1785 EP - 1795 ER - TY - JOUR A1 - Schneider, Jules A1 - Schwabedal, Justus T. C. A1 - Bialonski, Stephan T1 - Schlafspindeln – Funktion, Detektion und Nutzung als Biomarker für die psychiatrische Diagnostik JF - Der Nervenarzt N2 - Hintergrund: Die Schlafspindel ist ein Graphoelement des Elektroenzephalogramms (EEG), das im Leicht- und Tiefschlaf beobachtet werden kann. Veränderungen der Spindelaktivität wurden für verschiedene psychiatrische Erkrankungen beschrieben. Schlafspindeln zeigen aufgrund ihrer relativ konstanten Eigenschaften Potenzial als Biomarker in der psychiatrischen Diagnostik. Methode: Dieser Beitrag liefert einen Überblick über den Stand der Wissenschaft zu Eigenschaften und Funktionen der Schlafspindeln sowie über beschriebene Veränderungen der Spindelaktivität bei psychiatrischen Erkrankungen. Verschiedene methodische Ansätze und Ausblicke zur Spindeldetektion werden hinsichtlich deren Anwendungspotenzial in der psychiatrischen Diagnostik erläutert. Ergebnisse und Schlussfolgerung: Während Veränderungen der Spindelaktivität bei psychiatrischen Erkrankungen beschrieben wurden, ist deren exaktes Potenzial für die psychiatrische Diagnostik noch nicht ausreichend erforscht. Diesbezüglicher Erkenntnisgewinn wird in der Forschung gegenwärtig durch ressourcenintensive und fehleranfällige Methoden zur manuellen oder automatisierten Spindeldetektion ausgebremst. Neuere Detektionsansätze, die auf Deep-Learning-Verfahren basieren, könnten die Schwierigkeiten bisheriger Detektionsmethoden überwinden und damit neue Möglichkeiten für die praktisch KW - Schlafspindeldetektion KW - Psychiatrische Biomarker KW - · Psychiatrische Erkrankungen/Diagnostik KW - Elektroenzephalographie KW - Deep Learning Y1 - 2022 U6 - https://doi.org/10.1007/s00115-022-01340-z SN - 1433-0407 SP - 1 EP - 8 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Staat, Manfred T1 - Probabilistic assessment of the fracture mechanics behaviour of an HTR-module primary circuit pressure boundary JF - Nuclear Engineering and Design. 160 (1996), H. 1-2 Y1 - 1996 SN - 0029-5493 SP - 221 EP - 236 ER - TY - JOUR A1 - Laack, Walter van A1 - Casser, H. R. T1 - Cortisonbedingte Ablederung der Hüftkopfkappe / Laack, W. van ; Casser, H. R. JF - Neuere Ergebnisse in der Osteologie : Skelettwachstum, Endoprothetik, Glukokortikoide ; [15. - 18. Februar 1989 in Göttingen] / H.-G. Willert ; F. H. W. Heuck (Hrsg.) Y1 - 1989 SN - 3-540-51175-X N1 - Osteologia ; 4 SP - 566 EP - 568 PB - Springer CY - Berlin ER - TY - JOUR A1 - Bialonski, Stephan A1 - Lehnertz, Klaus T1 - Assortative mixing in functional brain networks during epileptic seizures JF - Chaos: An Interdisciplinary Journal of Nonlinear Science Y1 - 2013 U6 - https://doi.org/10.1063/1.4821915 VL - 23 IS - 3 SP - 033139 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Reliability Analysis of Elasto-Plastic Structures under Variable Loads JF - Inelastic analysis of structures under variable loads : theory and engineering applications / Maier, G.; Weichert, D. [ed] Y1 - 2000 SN - 0-7923-6645-X SP - 269 EP - 288 PB - Kluwer Academic Publ. CY - Dordrecht ER - TY - JOUR A1 - Stulpe, Werner A1 - Singer, Matthias T1 - Informational Incompleteness of the Observables Sx,Sy,Sz for Spin-1 Systems. Singer, Matthias; Stulpe, W. JF - Foundations of Physics. 20 (1990), H. 4 Y1 - 1990 SN - 1572-9516 SP - 471 EP - 472 ER - TY - JOUR A1 - Stulpe, Werner A1 - Singer, Matthias T1 - Phase-Space Representations of General Statistical Physical Theories. Singer, Matthias; Stulpe, Werner JF - Journal of Mathematical Physics. 33 (1992), H. 1 Y1 - 1992 SN - 1089-7658 SP - 131 EP - 142 ER - TY - JOUR A1 - Stulpe, Werner A1 - Singer, Matthias T1 - Some Remarks on the Determination of Quantum States by Measurements JF - Foundations of Physics Letters. 3 (1990), H. 2 Y1 - 1990 SN - 1572-9524 SP - 153 EP - 166 ER - TY - JOUR A1 - Stulpe, Werner T1 - On the Representation of Quantum Mechanics on a Classical Sample Space JF - International Journal of Theoretical Physics. 37 (1998), H. 1 Y1 - 1998 SN - 1572-9575 SP - 349 EP - 356 ER - TY - JOUR A1 - Stulpe, Werner A1 - Swat, Maciej T1 - Quantum States as Probability Measures JF - Foundations of Physics Letters. 14 (2001), H. 3 Y1 - 2001 SN - 1572-9524 SP - 285 EP - 293 ER - TY - JOUR A1 - Stulpe, Werner T1 - Conditional Expectations and Stochastic Processes in Quantum Probability JF - Information complexity and control in quantum physics : proceedings of the 4. Internat. Seminar on Mathematical Theory of Dynamical Systems and Microphysics, Udine, Sept. 4 - 13, 1985 / ed. by A. Blaquiere ... Y1 - 1987 SN - 3-211-81992-4 N1 - Courses and lectures / International Centre for Mechanical Sciences ; 294, International Seminar on Mathematical Theory of Dynamical Systems and Microphysics <4,1985, Udine> SP - 223 EP - 234 PB - Springer CY - Wien [u.a.] ER - TY - JOUR A1 - Bogoyavlenskiy, A. P. A1 - Berezin, V. E. A1 - Ogneva, A. V. A1 - Tolmacheva, V. P. A1 - Digel, Ilya A1 - Khudyakova, S. S. T1 - Immunostimulating activity of a saponin-containing extract of Saponaria officinalis JF - Voprosy virusologii Y1 - 1999 SN - 0507-4088 VL - 44 IS - 5 SP - 229 EP - 232 ER - TY - JOUR A1 - Mulhern, Colm A1 - Bialonski, Stephan A1 - Kantz, Holger T1 - Extreme events due to localization of energy JF - Physical Review E Y1 - 2015 U6 - https://doi.org/10.1103/PhysRevE.91.012918 SN - 2470-0053 VL - 91 IS - 1 SP - 012918 ER - TY - JOUR A1 - Iken, Heiko A1 - Ahlborn, Kristina A1 - Gerlach, Frank A1 - Vonau, Winfried A1 - Zander, Wilhelm A1 - Schubert, Jürgen P. A1 - Schöning, Michael Josef T1 - Development of redox glasses and subsequent processing by means of pulsed laser deposition for realizing silicon-based thin-film sensors JF - Electrochimica acta Y1 - 2013 SN - 1873-3859 (E-Journal); 0013-4686 (Print) SP - Available online 30.8.2013 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Baringhaus, Ludwig A1 - Gaigall, Daniel T1 - Hotelling’s T² tests in paired and independent survey samples: An efficiency comparison JF - Journal of Multivariate Analysis N2 - Hotelling’s T² tests in paired and independent survey samples are compared using the traditional asymptotic efficiency concepts of Hodges–Lehmann, Bahadur and Pitman, as well as through criteria based on the volumes of corresponding confidence regions. Conditions characterizing the superiority of a procedure are given in terms of population canonical correlation type coefficients. Statistical tests for checking these conditions are developed. Test statistics based on the eigenvalues of a symmetrized sample cross-covariance matrix are suggested, as well as test statistics based on sample canonical correlation type coefficients. Y1 - 2017 U6 - https://doi.org/10.1016/j.jmva.2016.11.004 SN - 0047-259X VL - 2017 IS - 154 SP - 177 EP - 198 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hafner, David A1 - Demetz, Oliver A1 - Weickert, Joachim A1 - Reißel, Martin T1 - Mathematical Foundations and Generalisations of the Census Transform for Robust Optic Flow Computation JF - Journal of Mathematical Imaging and Vision Y1 - 2014 U6 - https://doi.org/10.1007/s10851-014-0529-9 SN - 1573-7683 (Online) N1 - Springer Online First (ohne Seitenang. und Heftzuteilung) PB - Springer CY - New York ER - TY - JOUR A1 - Porschen, W. A1 - Gartzen, J. A1 - Gewehr, K. A1 - Mühlensiepen, H. A1 - Weber, Hans-Joachim A1 - Feinedegen, L E. T1 - In vivo assay of the radiation sensitivity of hypoxic tumour cells : influence of γ-rays, cyclotron neutrons, misonidazole, hyperthermia and mixed modalities JF - The British journal of cancer / Supplement N2 - Tumour cell death can be evaluated in the living mouse by externally measuring the rate of loss of tumour-bound DNA tracer. By sequentially labelling the tumour-bearing animals with ¹²⁵IUdR and ¹³¹IUdR 50 h apart, the average tumour cells at the time of the second injection are labelled by ¹²⁵IUdR and the euoxic tumour cells are specifically labelled with ¹³¹IUdR. Tumour treatment at this stage of labelling permits the observation of the reaction of euoxic cells and average tumour cells and finally yields data on hypoxic cells and thus on the oxygen enhancement ratio. This information adds to results from tumour control and growth delay. With this technique effects were analysed of 60-Co γ-rays, cyclotron neutrons (E = 6 MeV), misonidazole (500 mg/kg body wt) and hyperthermia (42°C water-bath), or combinations of these. Misonidazole (15 min before irradiation) altered the oxygen enhancement ratio by a factor of 1·5 for γ-rays and of 1·1 for neutrons; when evaluated from tumour-growth delay and TCD-50 misonidazole gave a dose modifying factor of 1·47 for γ-rays and of 1·2-1·3 for neutrons. Based on percentage tumour regression 100 days after treatment, the enhancement ratio from hyperthermia (after irradiation) was 2·75 for γ-rays (at 10 Gray) and 2·2 for neutrons (at 3·2 Gray). For neutrons combined with misonidazole and hyperthermia the ratio was 2·4. These results demonstrate that effects of neutron irradiation may be modified by electron-affinic substances and/or hyperthermia. Y1 - 1978 SN - 0306-9443 N1 - Section 6: Sensitization and Hypoxic Cytotoxicity: Effects of Hyperthermia and High Let IS - 3 SP - 194 EP - 197 PB - Lewis CY - London ER - TY - JOUR A1 - Albanna, Walid A1 - Conzen, Catharina A1 - Weiss, Miriam A1 - Clusmann, Hans A1 - Fuest, Matthias A1 - Mueller, Marguerite A1 - Brockmann, Marc Alexander A1 - Vilser, Walthard A1 - Schmidt-Trucksäss, Arno A1 - Hoellig, Anke A1 - Seiz, Marcel A1 - Thomé, Claudius A1 - Kotliar, Konstantin A1 - Schubert, Gerrit Alexander T1 - Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study JF - PLoS ONE N2 - Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2–14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort. Y1 - 2016 U6 - https://doi.org/10.1371/journal.pone.0158781 SN - 1932-6203 VL - 11 IS - 7 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Bialonski, Stephan A1 - Allefeld, Carsten A1 - Wellmer, Jörg A1 - Elger, Christian E. A1 - Lehnertz, Klaus T1 - An approach to identify synchronization clusters within the epileptic network JF - Klinische Neurophysiologie Y1 - 2008 U6 - https://doi.org/10.1055/s-2008-1072881 VL - 39 IS - 1 SP - A79 ER - TY - JOUR A1 - Grinsven, Bart van A1 - Vanden Bon, Natalie A1 - Grieten, Lars A1 - Murib, Mohammed Sharif A1 - Janssen, Stoffel Dominique A1 - Haenen, Ken A1 - Schneider, E. A1 - Ingebrandt, Sven A1 - Schöning, Michael Josef A1 - Vermeeren, Veronique A1 - Ameloot, Marcel A1 - Michiels, Luc A1 - Thoelen, Ronald A1 - De Ceuninck, Ward A. A1 - Wagner, Patrick T1 - Rapid assessment of the stability of DNA duplexes by impedimetric real-time monitoring of chemically induced denaturation JF - Lab on a Chip Y1 - 2011 SN - 1473-0197 VL - 11 IS - 9 SP - 1656 EP - 1663 PB - Royal Society of Chemistry (RSC) CY - Cambridge ER - TY - JOUR A1 - Murib, M. S. A1 - Grinsven, B. van A1 - Grieten, L. A1 - Janssens, S. D. A1 - Vermeeren, V. A1 - Eersels, K. A1 - Broeders, J. A1 - Ameloot, Marcel A1 - Michiels, L. A1 - Ceuninck, W. De A1 - Haenen, K. A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Electronic monitoring of chemical DNA denaturation on nanocrystalline diamond electrodes with different molarities and flow rates JF - Physica Status Solidi (A). Vol. 210 (2013), iss. 5 Y1 - 2013 SN - 0031-8965 SP - 911 EP - 917 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Murib, M. S. A1 - Yeap, W. S. A1 - Eurlings, Y. A1 - Grinsven, B. van A1 - Boyen, H.-G. A1 - Conings, B. A1 - Michiels, L. A1 - Ameloot, Marcel A1 - Carleer, R. A1 - Warmer, J. A1 - Kaul, P. A1 - Haenen, K. A1 - Schöning, Michael Josef A1 - Ceuninck, W. de A1 - Wagner, P. T1 - Heat-transfer based characterization of DNA on synthetic sapphire chips JF - Sensors and Actuators B: Chemical N2 - In this study, we show that synthetic sapphire (Al₂O₃), an established implant material, can also serve as a platform material for biosensors comparable to nanocrystalline diamond. Sapphire chips, beads, and powder were first modified with (3-aminopropyl) triethoxysilane (APTES), followed by succinic anhydride (SA), and finally single-stranded probe DNA was EDC coupled to the functionalized layer. The presence of the APTES-SA layer on sapphire powders was confirmed by thermogravimetric analyis and Fourier-transform infrared spectroscopy. Using planar sapphire chips as substrates and X-ray photoelectron spectroscopy (XPS) as surface-sensitive tool, the sequence of individual layers was analyzed with respect to their chemical state, enabling the quantification of areal densities of the involved molecular units. Fluorescence microscopy was used to demonstrate the hybridization of fluorescently tagged target DNA to the probe DNA, including denaturation- and re-hybridization experiments. Due to its high thermal conductivity, synthetic sapphire is especially suitable as a chip material for the heat-transfer method, which was employed to distinguish complementary- and non-complementary DNA duplexes containing single-nucleotide polymorphisms. These results indicate that it is possible to detect mutations electronically with a chemically resilient and electrically insulating chip material. Y1 - 2016 U6 - https://doi.org/10.1016/j.snb.2016.02.027 SN - 0925-4005 VL - 230 IS - 230 SP - 260 EP - 271 PB - Elsevier CY - Amsterdam ER -