TY - JOUR A1 - Herrmann, Ulf A1 - Nava, P. T1 - Die Strahlung der Sonne einfangen JF - DLR-Nachrichten / Deutsches Zentrum für Luft- und Raumfahrt Y1 - 2005 SN - 0937-0420 VL - 109 IS - Sonderheft Solarforschung SP - 34 EP - 37 ER - TY - JOUR A1 - Herrmann, Ulf A1 - Kelly, Bruce A1 - Price, Henry T1 - Two Tank Molten Salt Storage for Parabolic Trough Solar Power Plants JF - Energy : the international journal Y1 - 2002 U6 - http://dx.doi.org/10.1016/S0360-5442(03)00193-2 SN - 0360-5442 N1 - SolarPACES 2002, Zürich, Switzerland, 4–6 September 2002 VL - 29 IS - 5-6 (Special Issue SolarPaces) SP - 883 EP - 893 ER - TY - JOUR A1 - Kearney, David W. A1 - Kelly, Bruce A1 - Herrmann, Ulf A1 - Cable, R. A1 - Pacheco, J. A1 - Mahoney, R. A1 - Price, Henry A1 - Blake, D. A1 - Nava, P. A1 - Potrovitza, N. T1 - Engineering Aspects of a Molten Salt Heat Transfer Fluid in a Trough Solar Field JF - Energy : the international journal Y1 - 2002 U6 - http://dx.doi.org/10.1016/S0360-5442(03)00191-9 SN - 0360-5442 N1 - SolarPACES 2002, Zürich, Switzerland, 4–6 September 2002 VL - 29 IS - 5-6 (Special Issue SolarPaces) SP - 861 EP - 870 ER - TY - JOUR A1 - Dersch, Jürgen A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Jones, Scott A. A1 - Kelly, Bruce A1 - Kistner, Rainer A1 - Ortmanns, Winfried A1 - Pitz-Paal, Robert A1 - Price, Henry T1 - Trough integration into power plants—a study on the performance and economy of integrated solar combined cycle systems JF - Energy : the international journal Y1 - 2004 U6 - http://dx.doi.org/10.1016/S0360-5442(03)00199-3 SN - 0360-5442 N1 - SolarPACES 2002, Zürich, Switzerland, 4–6 September 2002 VL - 29 IS - 5-6 (Special Issue SolarPaces) SP - 947 EP - 959 ER - TY - CHAP A1 - Kelly, Bruce A1 - Herrmann, Ulf A1 - Hale, M.-J. T1 - Optimization Studies for Integrated Solar Combined Cycle Systems T2 - Solar engineering 2001 : proceedings of the International Solar Energy Conference ; presented at the 2001 International Solar Energy Conference, a part of Forum 2001 - Solar energy: the power to choose, April 21 - 25, 2001, Washington, D.C. Y1 - 2001 SN - 0-7918-1670-2 N1 - International Solar Energy Conference SP - 393 EP - 398 PB - ASME CY - New York, NY ER - TY - CHAP A1 - Dersch, Jürgen A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Jones, Scott A. A1 - Kelly, Bruce A1 - Kistner, Rainer A1 - Ortmanns, Winfried A1 - Pitz-Paal, Robert A1 - Price, Henry ED - Steinfeld, Aldo T1 - Trough integration into power plants : a study on the performance and economy of integrated solar combined cycle systems T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 661 EP - 671 PB - Paul Scherrer Inst. CY - Villingen ER - TY - CHAP A1 - Herrmann, Ulf A1 - Kelly, Bruce A1 - Price, Henry ED - Steinfeld, Aldo T1 - Two Tank Molten Salt Storage for Parabolic Trough Solar Power Plants T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 517 EP - 524 PB - Paul Scherrer Inst. CY - Villingen ER - TY - CHAP A1 - Dersch, Jürgen A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Jones, Scott A. A1 - Kelly, Bruce A1 - Kistner, Rainer A1 - Ortmanns, Winfried A1 - Pitz-Paal, Robert A1 - Price, Henry ED - Pearson, J. Boise T1 - Solar Trough Integration Into Combined Cycle Systems T2 - Solar engineering 2002 : proceedings of the International Solar Energy Conference ; presented at the 2002 International Solar Energy Conference, a part of Solar 2002 - Sunrise on the Reliable Energy Economy, June 15 - 20, 2002, Reno, Nevada Y1 - 2002 SN - 0-7918-1689-3 U6 - http://dx.doi.org/doi:10.1115/SED2002-1072 SP - 351 EP - 359 PB - ASME ER - TY - JOUR A1 - Herrmann, Ulf A1 - Lippke, F. T1 - The influence of transients on the design of DSG solar fields JF - Journal de Physique IV : proceedings Y1 - 1999 SN - 2-86883-402-7 U6 - http://dx.doi.org/10.1051/jp4:1999377 SN - 1764-7177 (Online) SN - 1155-4339 (Print) VL - 9 IS - PR3 SP - 489 EP - 494 ER - TY - CHAP A1 - Hahne, E. A1 - Herrmann, Ulf A1 - Rheinländer, J. ED - Girot, Michel T1 - The Effect of Tilt on Flow Pattern of Water/Steam Flow Through Heated Tubes T2 - Experimental heat transfer, fluid mechanics and thermodynamics 1997 : proceedings of the 4th World Conference on Experimental Heat Transfer, Fluid Mechanics and Thermodynamics, Brussels, June 2 - 6, 1997. - Vol. 2 Y1 - 1997 SN - 88-467-0014-7 SP - 925 EP - 934 PB - Ed. ETS CY - Pisa ER - TY - CHAP A1 - Herrmann, Ulf A1 - Rheinländer, J. A1 - Lippke, F. ED - Becker, Manfred T1 - Solar Fields for Direct Steam Generation in Parabolic Trough Collectors T2 - Components, tools, facilities and measurement techniques. - (Solar thermal concentrating technologies : proceedings of the 8th international symposium, October, 6 - 11, 1996, Köln, Germany ; Vol. 2) Y1 - 1997 SN - 3-7880-7616-X SP - 815 EP - 834 PB - Müller CY - Heidelberg ER - TY - CHAP A1 - Herrmann, Ulf A1 - Worringer, S. A1 - Graeter, F. A1 - Nava, P. ED - Romero, Manuel T1 - Three Years of Operation Experience of the SKAL-ET Collector Loop at SEGS V T2 - 13th International Symposium Concentrated Solar Power and Chemical Energy Technologies, June 20 - 23, 2006, Seville, Spain Y1 - 2006 SN - 84-7834-519-1 PB - SolarPACES [u.a.] CY - [s.l.] ER - TY - CHAP A1 - Herrmann, Ulf A1 - Graeter, F. A1 - Nava, P. ED - Ramos, C. T1 - Performance of the SKAL-ET Collector Loop at KJC Operating Company T2 - 12th International Symposium Solar Power and Chemical Energy Systems, October 6-8, 2004, Oaxaca Mexico ; SolarPACES International Symposium, 12 Y1 - 2004 SN - 968-6114-18-1 PB - Instituto de Investigaciones Electricas CY - [s.l.] ER - TY - CHAP A1 - Lüpfert, E. A1 - Herrmann, Ulf A1 - Price, Henry A1 - Zarza, E. A1 - Kistener, R. ED - Ramos, C. T1 - Towards Standard Performance Analysis for Parabolic Trough Collector Fields T2 - 12th International Symposium Solar Power and Chemical Energy Systems, October 6-8, 2004, Oaxaca Mexico ; SolarPACES International Symposium, 12 Y1 - 2004 SN - 968-6114-18-1 PB - Instituto de Investigaciones Electricas CY - [s.l.] ER - TY - THES A1 - Herrmann, Ulf T1 - Untersuchungen zur Rohrwandbenetzung bei der Dampferzeugung in horizontalen und geneigten Parabolrinnen-Solarkollektoren. - (FLAGSOL Forschungsbericht) Y1 - 2004 SN - 3-9804901-2-2 N1 - Zugl.: Aachen, Techn. Hochsch., Diss., 2004 PB - FLAGSOL CY - Köln ER - TY - CHAP A1 - Aringhoff, R. A1 - Geyer, Michael A1 - Herrmann, Ulf A1 - Kistner, Rainer A1 - Nava, P. A1 - Osuna, R. ED - Steinfeld, Aldo T1 - AndaSol : 50MW Solar Plants with 9 Hour Storage for Southern Spain T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 37 EP - 42 PB - Paul Scherrer Inst. CY - Villingen ER - TY - CHAP A1 - Latzke, Markus A1 - Alexopoulos, Spiros A1 - Kronhardt, Valentina A1 - Rendón, Carlos A1 - Sattler, Johannes, Christoph T1 - Comparison of Potential Sites in China for Erecting a Hybrid Solar Tower Power Plant with Air Receiver T2 - Energy Procedia Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.egypro.2015.03.142 SN - 1876-6102 N1 - International Conference on Concentrating Solar Power and Chemical Energy Systems, SolarPACES 2014, Beijing, China SP - 1327 EP - 1334 ER - TY - CHAP A1 - Göttsche, Joachim A1 - Korn, Michael A1 - Amato, Alexandre T1 - The Passivhaus concept for the Arabian Peninsula – An energetic-economical evaluation considering the thermal comfort T2 - QScience Proceedings: Vol 2015 N2 - The Passivhaus building standard is a concept developed for the realization of energy-efficient and economical buildings with a simultaneous high utilization comfort under European climate conditions. Major elements of the Passivhaus concept are a high thermal insulation of the external walls, the use of heat and/or solar shading glazing as well as an airtight building envelope in combination with energy-efficient technical building installations and heating or cooling generators, such as an efficient energy-recovery in the building air-conditioning. The objective of this research project is the inquiry to determine the parameters or constraints under which the Passivhaus concept can be implemented under the arid climate conditions in the Arabian Peninsula to achieve an energy-efficient and economical building with high utilization comfort. In cooperation between the Qatar Green Building Council (QGBC), Barwa Real Estate (BRE) and Kahramaa the first Passivhaus was constructed in Qatar and on the Arabian Peninsula in 2013. The Solar-Institut Jülich of Aachen University of Applied Science supports the Qatar Green Building Council with a dynamic building and equipment simulation of the Passivhaus and the neighbouring reference building. This includes simulation studies with different component configurations for the building envelope and different control strategies for heating or cooling systems as well as the air conditioning of buildings to find an energetic-economical optimum. Part of these analyses is the evaluation of the energy efficiency of the used energy recovery system in the Passivhaus air-conditioning and identification of possible energy-saving effects by the use of a bypass function integrated in the heat exchanger. In this way it is expected that on an annual basis the complete electricity demand of the building can be covered by the roof-integrated PV generator. Y1 - 2015 U6 - http://dx.doi.org/10.5339/qproc.2015.qgbc.38 N1 - 10.5339/qproc.2015.qgbc.38 = abstract - Qatar Green Building Conference 2015 - The Vision, 38. ER - TY - CHAP A1 - Göttsche, Joachim A1 - Röther, Sascha T1 - Science College Overbach - Innovatives Bildungszentrum in Jülich-Barmen T2 - 18. Internationale Passivhaustagung, Aachen, April 2014 N2 - Preprint der Autoren Y1 - 2014 ER - TY - JOUR A1 - Damm, Marc André A1 - Sauerborn, Markus A1 - Fend, Thomas A1 - Herrmann, Ulf T1 - Optimisation of a urea selective catalytic reduction system with a coated ceramic mixing element JF - Journal of ceramic science and technology Y1 - 2017 SN - 2190-9385 (Print) U6 - http://dx.doi.org/10.4416/JCST2016-00056 SN - 2190-9385 (Online) VL - 8 IS - 1 SP - 19 EP - 24 PB - Göller CY - Baden-Baden ER - TY - JOUR A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard T1 - Advances in solar tower technology JF - Wiley interdisciplinary reviews : Energy and Environment : WIREs Y1 - 2017 U6 - http://dx.doi.org/10.1002/wene.217 SN - 2041-840X VL - 6 IS - 1 SP - 1 EP - 19 PB - Wiley CY - Weinheim ER - TY - RPRT A1 - Esch, Thomas A1 - Damm, Marc André A1 - Kalbhenn, Hartmut T1 - Auslegung und Simulation eines Hybridantriebs für den teilelektrischen Betrieb eines Luftfahrzeuges der allgemeinen Luftfahrt : Schlussbericht für das Forschungsvorhaben ; Förderperiode 01.07.2009 - 31.05.2012 T1 - HyFly ; Design and simulation of a partially electrified operatin of an aircraft of the general aviation Y1 - 2013 U6 - http://dx.doi.org/10.2314/GBV:780055411 N1 - Report-Nr.: 1709X08 CY - Aachen ; Hannover ER - TY - RPRT A1 - Damm, Marc André A1 - Anthrakidis, Anette A1 - Fend, Thomas T1 - Partikelminderungssystem mit einstellbarem Partikelrückhaltegrad : Varytrap : Schlussbericht : Laufzeit: 01.07.2010-28.02.2014 Y1 - 2015 U6 - http://dx.doi.org/10.2314/GBV:848651863 N1 - Report-Nr: 17012X10 CY - Jülich ER - TY - RPRT A1 - Damm, Marc André A1 - Anthrakidis, Anette A1 - Fend, Thomas T1 - Keramische Porenkörpersysteme als SCR-Mischer und Hydrolysekatalysator : BMBF-Projekt: Hydromix : Schlussbericht : Laufzeit: 01.10.2011 bis 31.03.2015 Y1 - 2016 CY - Aachen ER - TY - JOUR A1 - Kearney, D. A1 - Herrmann, Ulf A1 - Nava, P. A1 - Kelly, B. A1 - Mahoney, R. A1 - Pacheco, J. A1 - Cable, R. A1 - Potrovitza, N. A1 - Blake, D. A1 - Price, H. T1 - Assessment of a Molten Salt Heat Transfer Fluid in a Parabolic Trough Solar Field JF - Journal of Solar Energy Engineering Y1 - 2003 U6 - http://dx.doi.org/10.1115/1.1565087 SN - 1528-8986 VL - 125 IS - 2 SP - 170 EP - 176 ER - TY - CHAP A1 - Anthrakidis, Anette A1 - Herrmann, Ulf A1 - Schorn, Christian A1 - Schwarzer, Klemens A1 - Wedding, Philipp A1 - Weis, Fabian T1 - Development and Testing of a Novel Method for the Determination of the Efficiency of Concentrating Solar Thermal Collectors T2 - Conference Proceedings Solar World Congress 2015, Daegu, Korea, 08 – 12 November 2015 Y1 - 2015 ER - TY - RPRT A1 - Weis, Fabian A1 - Schorn, Christian A1 - Anthrakidis, Anette A1 - Herrmann, Ulf T1 - Entwicklung eines kleinen Parabolrinnenkollektors mit Kunststoffkorpus zur Bereitstellung solarer Prozesswärme : Poly-P : Abschlussbericht Y1 - 2016 PB - Solar-Institut Jülich CY - Jülich ER - TY - CHAP A1 - Teixeira Boura, Cristiano José A1 - Niederwestberg, Stefan A1 - McLeod, Jacqueline A1 - Herrmann, Ulf A1 - Hoffschmidt, Bernhard T1 - Development of heat exchanger for high temperature energy storage with bulk materials T2 - AIP Conference Proceedings Y1 - 2016 U6 - http://dx.doi.org/10.1063/1.4949106 VL - 1734 IS - 1 SP - 050008-1 EP - 050008-7 ER - TY - CHAP A1 - Sauerborn, Markus A1 - Liebenstund, Lena A1 - Raue, Markus A1 - Mang, Thomas A1 - Herrmann, Ulf A1 - Dueing, Andreas T1 - Analytic method for material aging and quality analyzing to forecast long time stability of plastic micro heliostat components T2 - AIP Conference Proceedings Y1 - 2017 U6 - http://dx.doi.org/10.1063/1.4984388 VL - 1850 IS - 1 SP - 030045-1 EP - 030045-8 ER - TY - CHAP A1 - Herrmann, Ulf A1 - Kearney, D. A1 - Röger, M. A1 - Prahl, C. T1 - System performance measurements T2 - The Performance of Concentrated Solar Power (CSP) Systems : Modelling, Measurement and Assessment N2 - This chapter introduces performance and acceptance testing and describes state-of-the-art tools, methods, and instruments to assess the plant performance or realize plant acceptance testing. The status of the development of standards for performance assessment is given. KW - Performance measurement KW - Acceptance tests KW - Plant efficiency Y1 - 2017 SN - 978-0-08-100448-7 U6 - http://dx.doi.org/https://doi.org/10.1016/B978-0-08-100447-0.00005-5 SP - 115 EP - 165 PB - Woodhead Publishing CY - Duxford ER - TY - CHAP A1 - Rendon, Carlos A1 - Dieckmann, Simon A1 - Weidle, Mathias A1 - Dersch, Jürgen A1 - Teixeira Boura, Cristiano José A1 - Polklas, Thomas A1 - Kuschel, Marcus A1 - Herrmann, Ulf T1 - Retrofitting of existing parabolic trough collector power plants with molten salt tower systems T2 - AIP Conference Proceedings Y1 - 2018 U6 - http://dx.doi.org/10.1063/1.5067030 VL - 2033 IS - 1 SP - 030014-1 EP - 030014-8 ER - TY - CHAP A1 - Anthrakidis, Anette A1 - Herrmann, Ulf A1 - Schorn, Christian A1 - Schwarzer, Klemens A1 - Wedding, Philipp T1 - Weiterentwicklung und Erprobung eines neuartigen Verfahrens zur Bestimmung der Effizienz von konzentrierenden solarthermischen Kollektoren T2 - 25. OTTI Symposium Thermische Solarenergie Y1 - 2015 ER - TY - CHAP A1 - Schorn, Christian A1 - Weis, Fabian A1 - Anthrakidis, Anette A1 - Schwarzer, Klemens A1 - Schmitz, Mark A1 - Herrmann, Ulf T1 - Entwicklung und Bewertung eines Parabolrinnenkollektors zur Prozesswärmebereitstellung T2 - 26. Symposium Thermische Solarenergie, 20.-22.04.2016 in Bad Staffelstein Y1 - 2016 N1 - 26. OTTI Symposium Thermische Solarenergie SP - 1 EP - 13 ER - TY - JOUR A1 - Puppe, Michael A1 - Giuliano, Stefano A1 - Frantz, Cathy A1 - Uhlig, Ralf A1 - Schumacher, Ralph A1 - Ibraheem, Wagdi A1 - Schmalz, Stefan A1 - Waldmann, Barbara A1 - Guder, Christoph A1 - Peter, Dennis A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Alexopoulos, Spiros A1 - Spiegel, Michael A1 - Wortmann, Jürgen A1 - Hinrichs, Matthias A1 - Engelhard, Manfred A1 - Aust, Michael T1 - Techno-economic optimization of molten salt solar tower plants JF - AIP Conference Proceedings art.no. 040033 N2 - In this paper the results of a techno-economic analysis of improved and optimized molten salt solar tower plants (MSSTP plants) are presented. The potential improvements that were analyzed include different receiver designs, different designs of the HTF-system and plant control, increased molten salt temperatures (up to 640°C) and multi-tower systems. Detailed technological and economic models of the solar field, solar receiver and high temperature fluid system (HTF-system) were developed and used to find potential improvements compared to a reference plant based on Solar Two technology and up-to-date cost estimations. The annual yield model calculates the annual outputs and the LCOE of all variants. An improved external tubular receiver and improved HTF-system achieves a significant decrease of LCOE compared to the reference. This is caused by lower receiver cost as well as improvements of the HTF-system and plant operation strategy, significantly reducing the plant own consumption. A novel star receiver shows potential for further cost decrease. The cavity receiver concepts result in higher LCOE due to their high investment cost, despite achieving higher efficiencies. Increased molten salt temperatures seem possible with an adapted, closed loop HTF-system and achieve comparable results to the original improved system (with 565°C) under the given boundary conditions. In this analysis all multi tower systems show lower economic viability compared to single tower systems, caused by high additional cost for piping connections and higher cost of the receivers. REFERENCES Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5067069 VL - 2033 IS - Issue 1 PB - AIP Publishing CY - Melville, NY ER - TY - JOUR A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Hachul, Helmut A1 - Döring, Bernd A1 - Blanke, Tobias A1 - Göttsche, Joachim T1 - Plusenergiegebäude 2.0 in Stahlleichtbauweise JF - Stahlbau Y1 - 2019 U6 - http://dx.doi.org/10.1002/stab.201900034 SN - 1437-1049 (E-journal), 0038-9145 (print) VL - 88 IS - 6 SP - 522 EP - 528 PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Gorzalka, Philip A1 - Dahlke, Dennis A1 - Göttsche, Joachim A1 - Israel, Martin A1 - Patel, Dhruvkumar A1 - Prahl, Christoph A1 - Schmiedt, Jacob Estevam A1 - Frommholz, Dirk A1 - Hoffschmidt, Bernhard A1 - Linkiewicz, Magdalena T1 - Building Tomograph–From Remote Sensing Data of Existing Buildings to Building Energy Simulation Input T2 - EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria Y1 - 2018 ER - TY - CHAP A1 - Breitbach, Gerd A1 - Alexopoulos, Spiros A1 - May, Martin A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Analysis of volumetric solar radiation absorbers made of wire meshes T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117521 SN - 0094243X VL - 2126 SP - 030009-1 EP - 030009-6 ER - TY - CHAP A1 - Mahdi, Zahra A1 - Rendón, Carlos A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Novel concept for indirect solar-heated methane reforming T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117694 SN - 0094-243X VL - 2126 SP - 180014-1 EP - 180014-7 PB - AIP Publishing CY - Melville, NY ER - TY - CHAP A1 - May, Martin A1 - Breitbach, Gerd A1 - Alexopoulos, Spiros A1 - Latzke, Markus A1 - Bäumer, Klaus A1 - Uhlig, Ralf A1 - Söhn, Matthias A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Experimental facility for investigations of wire mesh absorbers for pressurized gases T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117547 SN - 0094243X VL - 2126 SP - 030035-1 EP - 030035-9 ER - TY - CHAP A1 - Sattler, Johannes, Christoph A1 - Alexopoulos, Spiros A1 - Caminos, Ricardo Alexander Chico A1 - Mitchell, John C. A1 - Ruiz, Victor C. A1 - Kalogirou, Soteris A1 - Ktistis, Panayiotis K. A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Dynamic simulation model of a parabolic trough collector system with concrete thermal energy storage for process steam generation T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117663 SN - 0094243X VL - 2126 SP - 150007-1 EP - 150007-8 ER - TY - JOUR A1 - Herrmann, Ulf A1 - Schwarzenbart, Marc A1 - Dittmann-Gabriel, Sören T1 - Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte JF - BWK : Das Energie-Fachmagazin Y1 - 2019 SN - 1436-4883 VL - 71 IS - 4 SP - 42 EP - 45 PB - Springer-VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Flesch, Robert A1 - Alexopoulos, Spiros A1 - Herrmann, Ulf T1 - Improved efficiency prediction of a molten salt receiver based on dynamic cloud passage simulation T2 - AIP Conference Proceedings Y1 - 2019 SN - 978-0-7354-1866-0 U6 - http://dx.doi.org/10.1063/1.5117566 VL - 2126 IS - 1 SP - 030054-1 EP - 030054-8 ER - TY - JOUR A1 - Wolisz, Henryk A1 - Schütz, Thomas A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Kohrn, Markus A1 - Wesseling, Mark A1 - Müller, Dirk T1 - Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets JF - Energy Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.energy.2017.06.025 VL - 137 SP - 715 EP - 728 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Blanke, Tobias A1 - Dring, Bernd A1 - Vontein, Marius A1 - Kuhnhenne, Markus T1 - Climate Change Mitigation Potentials of Vertical Building Integrated Photovoltaic T2 - 8th International Workshop on Integration of Solar Power into Power Systems : 16-17 October 2018, Stockholm, Sweden Y1 - 2018 SP - 1 EP - 7 ER - TY - JOUR A1 - Sattler, Johannes, Christoph A1 - Röger, Marc A1 - Schwarzbözl, Peter A1 - Buck, Reiner A1 - Macke, Ansgar A1 - Raeder, Christian A1 - Göttsche, Joachim T1 - Review of heliostat calibration and tracking control methods JF - Solar Energy N2 - Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun’s position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.solener.2020.06.030 VL - 207 SP - 110 EP - 132 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - El Moussaoui, Noureddine A1 - Talbi, Sofian A1 - Atmane, Ilyas A1 - Kassmi, Khalil A1 - Schwarzer, Klemens A1 - Chayeb, Hamid A1 - Bachiri, Najib T1 - Feasibility of a new design of a Parabolic Trough Solar Thermal Cooker (PSTC) JF - Solar Energy N2 - In this article, we describe the structure, the functioning, and the tests of parabolic trough solar thermal cooker (PSTC). This oven is designed to meet the needs of rural residents, including Urban, which requires stable cooking temperatures above 200 °C. The cooking by this cooker is based on the concentration of the sun's rays on a glass vacuum tube and heating of the oil circulate in a big tube, located inside the glass tube. Through two small tubes, associated with large tube, the heated oil, rise and heats the pot of cooking pot containing the food to be cooked (capacity of 5 kg). This cooker is designed in Germany and extensively tested in Morocco for use by the inhabitants who use wood from forests. During a sunny day, having a maximum solar radiation around 720 W/m2 and temperature ambient around 26 °C, maximum temperatures recorded of the small tube, the large tube and the center of the pot are respectively: 370 °C, 270 °C and 260 °C. The cooking process with food at high (fries, ..), we show that the cooking oil temperature rises to 200 °C, after 1 h of heating, the cooking is done at a temperature of 120 °C for 20 min. These temperatures are practically stable following variations and decreases in the intensity of irradiance during the day. The comparison of these results with those of the literature shows an improvement of 30–50 % on the maximum value of the temperature with a heat storage that could reach 60 min of autonomy. All the results obtained show the good functioning of the PSTC and the feasibility of cooking food at high temperature (>200 °C). Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.solener.2020.03.079 SN - 0038-092X VL - 201 IS - Vol. 201 (May 2020) SP - 866 EP - 871 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Alexopoulos, Spiros A1 - Rau, Christoph A1 - Sattler, Johannes, Christoph A1 - Anthrakidis, Anette A1 - Teixeira Boura, Cristiano José A1 - O’Connor, B. A1 - Caminos, R.A. Chico A1 - Rendón, C. A1 - Hilger, P. T1 - Concentrating Solar Power T2 - Earth systems and environmental sciences N2 - The focus of this chapter is the production of power and the use of the heat produced from concentrated solar thermal power (CSP) systems. The chapter starts with the general theoretical principles of concentrating systems including the description of the concentration ratio, the energy and mass balance. The power conversion systems is the main part where solar-only operation and the increase in operational hours. Solar-only operation include the use of steam turbines, gas turbines, organic Rankine cycles and solar dishes. The operational hours can be increased with hybridization and with storage. Another important topic is the cogeneration where solar cooling, desalination and of heat usage is described. Many examples of commercial CSP power plants as well as research facilities from the past as well as current installed and in operation are described in detail. The chapter closes with economic and environmental aspects and with the future potential of the development of CSP around the world. KW - Central receiver power plant KW - Concentrated systems KW - Concentrating solar power KW - Fresnel power plant KW - Gas turbine Y1 - 2021 SN - 978-0-12-409548-9 U6 - http://dx.doi.org/10.1016/B978-0-12-819727-1.00089-3 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schwager, Christian A1 - Flesch, Robert A1 - Schwarzbözl, Peter A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José T1 - Advanced two phase flow model for transient molten salt receiver system simulation JF - Solar Energy N2 - In order to realistically predict and optimize the actual performance of a concentrating solar power (CSP) plant sophisticated simulation models and methods are required. This paper presents a detailed dynamic simulation model for a Molten Salt Solar Tower (MST) system, which is capable of simulating transient operation including detailed startup and shutdown procedures including drainage and refill. For appropriate representation of the transient behavior of the receiver as well as replication of local bulk and surface temperatures a discretized receiver model based on a novel homogeneous two-phase (2P) flow modelling approach is implemented in Modelica Dymola®. This allows for reasonable representation of the very different hydraulic and thermal properties of molten salt versus air as well as the transition between both. This dynamic 2P receiver model is embedded in a comprehensive one-dimensional model of a commercial scale MST system and coupled with a transient receiver flux density distribution from raytracing based heliostat field simulation. This enables for detailed process prediction with reasonable computational effort, while providing data such as local salt film and wall temperatures, realistic control behavior as well as net performance of the overall system. Besides a model description, this paper presents some results of a validation as well as the simulation of a complete startup procedure. Finally, a study on numerical simulation performance and grid dependencies is presented and discussed. KW - Molten salt solar tower KW - Molten salt receiver system KW - Dynamic simulation KW - Two-phase modelling KW - Transient flux distribution Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.solener.2021.12.065 SN - 0038-092X (print) SN - 1471-1257 (online) VL - 232 SP - 362 EP - 375 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Gedle, Yibekal A1 - Schmitz, Mark A1 - Gielen, Hans A1 - Schmitz, Pascal A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José A1 - Mahdi, Zahra A1 - Caminos, Ricardo Alexander Chico A1 - Dersch, Jürgen T1 - Analysis of an integrated CSP-PV hybrid power plant T2 - SolarPACES 2020 N2 - In the past, CSP and PV have been seen as competing technologies. Despite massive reductions in the electricity generation costs of CSP plants, PV power generation is - at least during sunshine hours - significantly cheaper. If electricity is required not only during the daytime, but around the clock, CSP with its inherent thermal energy storage gets an advantage in terms of LEC. There are a few examples of projects in which CSP plants and PV plants have been co-located, meaning that they feed into the same grid connection point and ideally optimize their operation strategy to yield an overall benefit. In the past eight years, TSK Flagsol has developed a plant concept, which merges both solar technologies into one highly Integrated CSP-PV-Hybrid (ICPH) power plant. Here, unlike in simply co-located concepts, as analyzed e.g. in [1] – [4], excess PV power that would have to be dumped is used in electric molten salt heaters to increase the storage temperature, improving storage and conversion efficiency. The authors demonstrate the electricity cost sensitivity to subsystem sizing for various market scenarios, and compare the resulting optimized ICPH plants with co-located hybrid plants. Independent of the three feed-in tariffs that have been assumed, the ICPH plant shows an electricity cost advantage of almost 20% while maintaining a high degree of flexibility in power dispatch as it is characteristic for CSP power plants. As all components of such an innovative concept are well proven, the system is ready for commercial market implementation. A first project is already contracted and in early engineering execution. KW - Hybrid energy system KW - Power plants KW - Electricity generation KW - Energy storage KW - Associated liquids Y1 - 2022 SN - 978-0-7354-4195-8 U6 - http://dx.doi.org/10.1063/5.0086236 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - 26th International Conference on Concentrating Solar Power and Chemical Energy Systems 28 September–2 October 2020 Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Mahdi, Zahra A1 - Dersch, Jürgen A1 - Schmitz, Pascal A1 - Dieckmann, Simon A1 - Caminos, Ricardo Alexander Chico A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf A1 - Schwager, Christian A1 - Schmitz, Mark A1 - Gielen, Hans A1 - Gedle, Yibekal A1 - Büscher, Rauno T1 - Technical assessment of Brayton cycle heat pumps for the integration in hybrid PV-CSP power plants T2 - SOLARPACES 2020 N2 - The hybridization of Concentrated Solar Power (CSP) and Photovoltaics (PV) systems is a promising approach to reduce costs of solar power plants, while increasing dispatchability and flexibility of power generation. High temperature heat pumps (HT HP) can be utilized to boost the salt temperature in the thermal energy storage (TES) of a Parabolic Trough Collector (PTC) system from 385 °C up to 565 °C. A PV field can supply the power for the HT HP, thus effectively storing the PV power as thermal energy. Besides cost-efficiently storing energy from the PV field, the power block efficiency of the overall system is improved due to the higher steam parameters. This paper presents a technical assessment of Brayton cycle heat pumps to be integrated in hybrid PV-CSP power plants. As a first step, a theoretical analysis was carried out to find the most suitable working fluid. The analysis included the fluids Air, Argon (Ar), Nitrogen (N2) and Carbon dioxide (CO2). N2 has been chosen as the optimal working fluid for the system. After the selection of the ideal working medium, different concepts for the arrangement of a HT HP in a PV-CSP hybrid power plant were developed and simulated in EBSILON®Professional. The concepts were evaluated technically by comparing the number of components required, pressure losses and coefficient of performance (COP). KW - Solar thermal technologies KW - Hybrid energy system KW - Concentrated solar power KW - Power plants KW - Energy storage Y1 - 2022 SN - 978-0-7354-4195-8 U6 - http://dx.doi.org/10.1063/5.0086269 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - 26th International Conference on Concentrating Solar Power and Chemical Energy Systems 28 September–2 October 2020 Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER -