TY - CHAP A1 - Zischank, Wolfgang J. A1 - Kern, Alexander A1 - Frentzel, Ralf A1 - Heidler, Fridolin A1 - Seevers, M. T1 - Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants N2 - Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables. KW - Blitzschutz KW - Elektromagnetische Kopplung KW - Überspannung KW - Kraftwerke KW - Industrieanlagen KW - Lightning KW - current distribution KW - electromagnetic coupling KW - overvoltages Y1 - 2000 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. A1 - Stimper, K. A1 - Kern, Alexander A1 - Seevers, M. T1 - Magnetic Fields and Induced Voltages inside LPZ 1 Measured at a 1:6 Scale Model Building N2 - Laborexperimente zu Blitzschutzzonen in Stahlbetongebäuden anhand eines Modells im Maßstab 1:6 N2 - For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied. KW - Blitzschlag KW - Elektromagnetischer Schutzschild KW - Stahlbeton KW - Maßstabsgetreues Modell KW - Lightning KW - electromagnetic shielding KW - reinforced concrete KW - scaled model Y1 - 2004 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Kern, Alexander A1 - Metwally, I. A. A1 - Wiesinger, J. A1 - Seevers, M. T1 - Laboratory simulation of direct lightning strokes to a modelled building - measurement of magnetic fields and induced voltages N2 - In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived. KW - Direkter Blitzschlag KW - Elektromagnetischer Schutzschild KW - Magnetische Felder KW - Induzierte Spannungen KW - Stahlbetonkonstruktion KW - Lightning KW - electromagnetic shielding KW - magnetic field KW - reinforced concrete KW - induced voltage Y1 - 2002 ER - TY - CHAP A1 - Weßling, Matthias T1 - Leadership Perspectives: Research Findings, Theories, Practical Experiences N2 - Leadership Perspectives: Research Findings, Theories, Practical Experiences: Results of Leadership Research and exemplarily application cases show the perspectives and consequences for leadership practice and the following requirements for executives in future. N2 - Leadership Perspectives: Research Findings, Theories, Practical Experiences: Bisherige Ergebnisse der betriebswirtschaftlichen Führungsforschung und exemplarische Anwendungsbeispiele der Führungspraxis, sowie die Schlußfolgerungen für die Perspektiven der betrieblichen Mitarbeiterführung sowie die sich daraus ergebenden Anforderungen an zukünftige Führungskräfte. KW - Leadership KW - Führung KW - Führungsansätze KW - Leadership KW - Self-Leadership KW - Leadership Approaches KW - Skill Assessment KW - Leadership Theories Y1 - 2007 ER - TY - CHAP A1 - Weßling, Matthias T1 - Motivation and Leadership - The Reiss-Profile of the 16 Basic Desires: Research results and managerial applications N2 - Recent Results of the scientific Reiss-Profile (16 basic desires) due to the concept of Prof. Dr. Steven Reiss (State University Ohio, U.S.A.), supplemented by the comparative analysis of empirical motivational profiles of european executives of various companies. N2 - Neuere Forschungsergebnisse des wissenschaftlichen Reiss-Profils der 16 Lebensmotive nach Prof. Dr. Steven Reiss (State University Ohio, U.S.A.) und die Möglichkeiten und Grenzen ihrer Umsetzung in der betrieblichen Führungspraxis unter Integration der vergleichenden Analyse und Interpretation empirisch erhobener Motivprofile einzelner europäischer Führungskräfte. KW - Motivation KW - Leadership KW - Motivation KW - Führung KW - Motivation KW - Leadership Y1 - 2007 ER - TY - CHAP A1 - Weßling, Matthias T1 - Provocative Communication in Coaching and Leadership: scientific research and managerial applications of the Provocative Communication Style N2 - Concept, scientific research and managerial applications of Provocative Coaching, according to the „Provocative Therapy“ of Prof. Dr. Frank Farrelly (University of Wisconsin, U.S.A) in terms of an application of the Provocative Communication Style in specific situations of practical leadership, especially in the role of a coach for their subordinates. N2 - Konzept, Forschungsergebnisse und Tools der sogenannten „Provocative Therapy“ nach Prof. Dr. Frank Farrelly (University of Wisconsin, U.S.A) und ihre Anwendung als provokativer Kommunikationsstil einer Führungskraft in spezifischen Situationen der betrieblichen Führungspraxis in der Rolle eines Coaches. KW - Kommunikation KW - Coaching KW - Führung KW - Kommunikation KW - Coaching KW - Führung KW - Provokativer Stil KW - Provocative Coaching KW - Leadership KW - Communication KW - Provocative Style Y1 - 2007 ER - TY - CHAP A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Preface of the Special Issue of I3S 2005 in Jülich (Germany) N2 - International Symposium on Sensor Science, I3S 2005 <3; 2005; Juelich, Germany> In: Sensors 2006, 6, 260-261 ISSN 1424-8220 KW - Biosensor KW - I3S 2005 KW - International Symposium on Sensor Science Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1365 ER - TY - CHAP A1 - Wagner, Thorsten A1 - Kohl, Claus-Dieter A1 - Fröba, Michael A1 - Tiemann, Michael T1 - Gas sensing properties of ordered mesoporous SnO2 N2 - We report on the synthesis and CO gas-sensing properties of mesoporous tin(IV) oxides (SnO2). For the synthesis cetyltrimethylammonium bromide (CTABr) was used as a structure-directing agent; the resulting SnO2 powders were applied as films to commercially available sensor substrates by drop coating. Nitrogen physisorption shows specific surface areas up to 160 m2·g-1 and mean pore diameters of about 4 nm, as verified by TEM. The film conductance was measured in dependence on the CO concentration in humid synthetic air at a constant temperature of 300 °C. The sensors show a high sensitivity at low CO concentrations and turn out to be largely insensitive towards changes in the relative humidity. We compare the materials with commercially available SnO2-based sensors. KW - Biosensor KW - Tin oxide KW - sensing properties KW - CO KW - humidity Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1422 ER - TY - CHAP A1 - Uibel, Thomas A1 - Blaß, Hans Joachim ED - Cecotti, A. T1 - Determining Suitable Spacings and Distances for Self-tapping Screws by Experimental and Numerical Studies T2 - Proceedings of the 11th World Conference on Timber Engineering, WCTE 2010 : World Conference on Timber Engineering; [June 20 - 24, 2010, Riva del Garda, Trento, Italy] . Vol. III, Riva del Garda, Italy 2010 Y1 - 2010 N1 - Extended abstract. Full paper: DVD, Session 55, ID 108, 9 Seiten SP - 669 EP - 670 ER - TY - CHAP A1 - Uibel, Thomas A1 - Blaß, Hans Joachim T1 - A new method to determine suitable spacings and distances for self-tapping screws T2 - Meeting ... / International Council for Research and Innovation in Building and Construction, Working Commission W18 - Timber Structures N2 - The determination of spacing, edge and end distance requirements for self-tapping screws requires numerous and comprehensive insertion tests. Yet the results of such tests cannot be transferred to other types of screws or even to screws of different diameter because of differences in shape or geometry. To reduce the effort of insertion tests a new method was developed which allows the estimation of required spacings, distances and timber thickness. Y1 - 2010 SN - 1864-1784 N1 - Paper 43-21-2 VL - 43 PB - Lehrstuhl für Ingenieurholzbau und Baukonstruktionen CY - Karlsruhe ER -