TY - JOUR A1 - Wilson, C. E. A1 - Dickie, A. P. A1 - Schreiter, K. A1 - Wehr, R. A1 - Wilson, E. M. A1 - Bial, J. A1 - Scheer, Nico A1 - Wilson, I. D. A1 - Riley, R. J. T1 - The pharmacokinetics and metabolism of diclofenac in chimeric humanized and murinized FRG mice JF - Archives of Toxicology N2 - The pharmacokinetics of diclofenac were investigated following single oral doses of 10 mg/kg to chimeric liver humanized and murinized FRG and C57BL/6 mice. In addition, the metabolism and excretion were investigated in chimeric liver humanized and murinized FRG mice. Diclofenac reached maximum blood concentrations of 2.43 ± 0.9 µg/mL (n = 3) at 0.25 h post-dose with an AUCinf of 3.67 µg h/mL and an effective half-life of 0.86 h (n = 2). In the murinized animals, maximum blood concentrations were determined as 3.86 ± 2.31 µg/mL at 0.25 h post-dose with an AUCinf of 4.94 ± 2.93 µg h/mL and a half-life of 0.52 ± 0.03 h (n = 3). In C57BL/6J mice, mean peak blood concentrations of 2.31 ± 0.53 µg/mL were seen 0.25 h post-dose with a mean AUCinf of 2.10 ± 0.49 µg h/mL and a half-life of 0.51 ± 0.49 h (n = 3). Analysis of blood indicated only trace quantities of drug-related material in chimeric humanized and murinized FRG mice. Metabolic profiling of urine, bile and faecal extracts revealed a complex pattern of metabolites for both humanized and murinized animals with, in addition to unchanged parent drug, a variety of hydroxylated and conjugated metabolites detected. The profiles in humanized mice were different to those of both murinized and wild-type animals, e.g., a higher proportion of the dose was detected in the form of acyl glucuronide metabolites and much reduced amounts as taurine conjugates. Comparison of the metabolic profiles obtained from the present study with previously published data from C57BL/6J mice and humans revealed a greater, though not complete, match between chimeric humanized mice and humans, such that the liver humanized FRG model may represent a model for assessing the biotransformation of such compounds in humans. Y1 - 2018 U6 - http://dx.doi.org/10.1007/s00204-018-2212-1 SN - 1432-0738 VL - 92 IS - 6 SP - 1953 EP - 1967 PB - Springer ER - TY - CHAP A1 - Bindzus, Manuel A1 - Bragard, Michael T1 - Motivating Intuitive Understanding of the Switched Reluctance Machine in the Education of Undergraduate Students T2 - 2018 IEEE 59th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON) Y1 - 2018 SN - 978-1-5386-6903-7 U6 - http://dx.doi.org/10.1109/RTUCON.2018.8659870 SP - 1 EP - 6 ER - TY - CHAP A1 - Bragard, Michael A1 - Hoek, Hauke van A1 - Hoegen, Anne von A1 - Doncker, Rik W. De T1 - Motivation-based Learning: Teaching Fundamentals of Electrical Engineering with an LED Spinning Top T2 - 2018 IEEE 59th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON) Y1 - 2018 SN - 978-1-5386-6903-7 U6 - http://dx.doi.org/10.1109/RTUCON.2018.8659810 SP - 1 EP - 6 ER - TY - CHAP A1 - Rütters, René A1 - Weinheimer, Marius A1 - Bragard, Michael T1 - Teaching Control Theory with a Simplified Helicopter Model and a Classroom Fitting Hardware Test-Bench T2 - 2018 IEEE 59th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON) Y1 - 2018 SN - 978-1-5386-6903-7 U6 - http://dx.doi.org/10.1109/RTUCON.2018.8659871 ER - TY - CHAP A1 - Serror, Martin A1 - Henze, Martin A1 - Hack, Sacha A1 - Schuba, Marko A1 - Wehrle, Klaus T1 - Towards in-network security for smart homes T2 - 13th International Conference on Availability, Reliability and Security, ARES 2018; Hamburg; Germany; 27 August 2018 through 30 August 2018 Y1 - 2018 SN - 978-145036448-5 U6 - http://dx.doi.org/10.1145/3230833.3232802 SP - Article numer 3232802 ER - TY - CHAP A1 - Röth, Thilo A1 - Deutskens, Christoph A1 - Kreisköther, Kai A1 - Heimes, Heiner Hans A1 - Schittny, Bastian A1 - Ivanescu, Sebastian A1 - Kleine Büning, Max A1 - Reinders, Christian A1 - Wessels, Saskia A1 - Haunreiter, Andreas A1 - Reisgen, Uwe A1 - Thiele, Regina A1 - Hameyer, Kay A1 - Doncker, Rik W. de A1 - Sauer, Uwe A1 - Hoek, Hauke van A1 - Hübner, Mareike A1 - Hennen, Martin A1 - Stolze, Thilo A1 - Vetter, Andreas A1 - Hagedorn, Jürgen A1 - Müller, Dirk A1 - Rewitz, Kai A1 - Wesseling, Mark A1 - Flieger, Björn T1 - Entwicklung von elektrofahrzeugspezifischen Systemen T2 - Elektromobilität N2 - Die Batterie ist eine der absolut zentralen Komponenten des Elektrofahrzeugs. Die serielle Entwicklung und Produktion dieser Batterien und die Verbesserung der Leistungen wird entscheidend für den Erfolg der Elektromobilität sein. Die Batterie ist jedoch nicht das einzige elektrofahrzeugspezifische System, das neu entwickelt, umkonzipiert oder verbessert werden muss. So sind ebenso die Entwicklung der neuen Fahrzeugstruktur sowie des elektrifizierten Antriebsstranges Teil dieses Kapitels. Weiterhin wird ein Blick auf das bedeutende Thema des Thermomanagements geworfen. Y1 - 2018 SN - 978-3-662-53137-2 U6 - http://dx.doi.org/10.1007/978-3-662-53137-2_6 SP - 279 EP - 386 PB - Springer Vieweg CY - Berlin, Heidelberg ER - TY - JOUR A1 - Laura, C.O. A1 - Drechsler, Klaus A1 - Erdt, M. A1 - Wesarg, S. A1 - Bale, R. T1 - Intervention assessment tool for primary tumors in the liver JF - Current Directions in Biomedical Engineering N2 - After a liver tumor intervention the medical doctor has to compare both pre and postoperative CT acquisitions to ensure that all carcinogenic cells are destroyed. A correct assessment of the intervention is of vital importance, since it will reduce the probability of tumor recurrence. Some methods have been proposed to support the medical doctors during the assessment process, however, all of them focus on secondary tumors. In this paper a tool is presented that enables the outcome validation for both primary and secondary tumors. Therefore, a multiphase registration (preoperative arterial and portal phases) followed by a registration between the pre and postoperative CT images is carried out. The first registration is in charge of the primary tumors that are only visible in the arterial phase. The secondary tumors will be incorporated in the second registration step. Finally, the part of the tumor that was not covered by the necrosis is quantified and visualized. The method has been tested in 9 patients, with an average registration error of 1.41 mm. Y1 - 2018 U6 - http://dx.doi.org/10.1515/cdbme-2018-0081 SN - 2364-5504 VL - 4 IS - 1 SP - 337 EP - 340 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Heinke, Lars N. A1 - Knicker, Axel J. A1 - Albracht, Kirsten T1 - Evaluation of passively induced shoulder stretch reflex using an isokinetic dynamometer in male overhead athletes JF - Isokinetics and Exercise Science N2 - BACKGROUND: Muscle stretch reflexes are widely considered to beneficially influence joint stability and power generation in the lower limbs. While in the upper limbs and especially in the muscles surrounding the shoulder joint such evidence is lacking. OBJECTIVE: To quantify the electromyographical response in the muscles crossing the shoulder of specifically trained overhead athletes to an anterior perturbation force. METHODS: Twenty healthy male participants performed six sets of different external shoulder rotation stretches on an isokinetic dynamometer over a range of amplitudes and muscle pre-activation moment levels. All stretches were applied with a dynamometer acceleration of 10,000∘/s2 and a velocity of 150∘/s. Electromyographical response was measured via sEMG. RESULTS: Consistent reflexes were not observed in all experimental conditions. The reflex latencies revealed a significant muscle main effect (F (2,228) = 99.31, p< 0.001; η2= 0.466; f= 0.934) and a pre-activation main effect (F (1,228) = 142.21, p< 0.001; η2= 0.384; f= 1.418). The stretch reflex amplitude yielded a significant pre-activation main effect (F (1,222) = 470.373, p< 0.001; η2= 0.679; f= 1.454). CONCLUSION: Short latency muscle reflexes showed a tendency to an anterior to posterior muscle recruitment whereby the main internal rotator muscles of the shoulder revealed the most consistent results. Y1 - 2018 U6 - http://dx.doi.org/10.3233/IES-184111 SN - 1878-5913 VL - 26 IS - 4 SP - 265 EP - 274 PB - IOS Press CY - Amsterdam ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines T1 - Vaskuläre Biomarker der retinalen Gefäβanalyse T1 - Vascular Biomarkers in Retinal Vessel Analysis JF - Klinische Monatsblätter fur Augenheilkunde N2 - Mit modernen nicht invasiven bildgebenden Verfahren lassen sich anhand der Fundusfotografie bzw. der optischen Verfilmung Aspekte der funktionellen und strukturellen retinalen Gefäßveränderungen objektiv untersuchen. Der Zustand und das Verhalten retinaler Gefäße beeinflussen im prä-, post- und kapillaren Bereich den Blutfluss und strömungsbedingte Stoffwechselverhältnisse passiv und aktiv über den Gefäßdurchmesser. Retinale Gefäße gleichen von Aufbau und Funktion den zerebralen Gefäßen und spiegeln den Zustand der Mikrozirkulation wider. Mithilfe von aus den Gefäßweiten berechneten Biomarkern soll eine Aussage über die Prognose von systemischen vaskulär bedingten Erkrankungen getroffen werden. Die statische retinale Gefäßanalyse befasst sich mit der Untersuchung des Zustandes der prä- und postkapillaren Gefäßdurchmesser der retinalen Mikrozirkulation anhand einer optischen Fundusaufnahme. Bei der dynamischen retinalen Gefäßanalyse wird der Längsschnitt eines retinalen Gefäßes nicht invasiv funktionell und strukturell über einen Zeitraum vor, während und nach einer spezifischen vaskulären Stimulation untersucht. Die genaue Methodologie der Auswertung und die Bezeichnung der Parameter variieren bei unterschiedlichen Ansätzen. Mittels retinaler Gefäßanalyse wurden bislang mehrere klinische Querschnitts- und Interventionsstudien in der Augenheilkunde und anderen Fachgebieten, inkl. Kardiologie, Neurologie, Neurochirurgie, Nephrologie, Gynäkologie, Sportmedizin, Diabetologie, Hypertensiologie usw. durchgeführt. Mit der statischen retinalen Gefäßanalyse steht eine kostengünstige, reproduzierbare, nicht invasive Screeningtechnik zur Verfügung, um eine prognostische Aussage über die Gefäßgesundheit eines individuellen Patienten zu treffen. Die dynamische retinale Gefäßanalyse besitzt ein weiteres diagnostisches Anwendungsspektrum als die statische, da sie das Verhalten retinaler Gefäße zeitkontinuierlich untersucht. Die Evaluation vaskulärer Erkrankungen sowie zerebro- bzw. kardiovaskulärer Morbidität und Mortalität mittels mehrerer methodologischer Modalitäten retinaler Gefäßanalyse mit ihren jeweiligen quantitativen Biomarkern bietet eine zukunftsträchtige diagnostische Perspektive. Die interdisziplinäre klinische Anwendung dieser vaskulären Biomarker gewinnt zunehmend an Bedeutung, sowohl in der Augenheilkunde als auch in anderen Fachgebieten. Y1 - 2018 U6 - http://dx.doi.org/10.1055/a-0774-7987 SN - 0023-2165 VL - 235 IS - 12 SP - 1352 EP - 1359 PB - Thieme CY - Stuttgart ER - TY - CHAP A1 - Gao, H. A1 - Babilon, Katharina A1 - Pfaff, Raphael A1 - Gan, F. A1 - Reich, A. T1 - Model of wheel-rail contact for sanding and adhesion enhancement T2 - Proceedings of the 11th International Conference on Contact Mechanics and Wear of Rail/wheel Systems, CM 2018 Y1 - 2018 SN - 978-946186963-0 SP - 314 EP - 321 ER -