TY - JOUR A1 - Bung, Daniel Bernhard T1 - Developing flow in skimming flow regime on embankment stepped spillways JF - Journal of hydraulic research Y1 - 2011 SN - 1814-2079 (E-Journal); 0022-1686 (Print) VL - Vol. 49 IS - Iss. 5 SP - 639 EP - 648 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Wolisz, Henryk A1 - Schütz, Thomas A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Kohrn, Markus A1 - Wesseling, Mark A1 - Müller, Dirk T1 - Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets JF - Energy Y1 - 2017 U6 - https://doi.org/10.1016/j.energy.2017.06.025 VL - 137 SP - 715 EP - 728 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Tullis, Blake P. A1 - Crookston, Brian M. A1 - Bung, Daniel Bernhard T1 - Weir head-discharge relationships: A multi-lab exercise T2 - E-proceedings of the 38th IAHR World Congress September 1-6, 2019, Panama City, Panama Y1 - 2019 SP - 1 EP - 15 ER - TY - JOUR A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Reger, Vitali A1 - Kuhnhenne, Markus T1 - Net-exergetic, hydraulic and thermal optimization of coaxial heat exchangers using fixed flow conditions instead of fixed flow rates JF - Geothermal Energy N2 - Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar fow and 60% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the fow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics. Y1 - 2021 U6 - https://doi.org/10.1186/s40517-021-00201-3 SN - 2195-9706 N1 - Corresponding author: Tobias Blanke VL - 9 IS - Article number: 19 PB - Springer CY - Berlin ER - TY - CHAP A1 - Ahmed, H. A1 - Schlenkhoff, A. A1 - Bung, Daniel Bernhard T1 - Hydrodynamic characteristics of vertical slotted wall breakwaters T2 - Balance and uncertainty - water in a changing world : proceedings of the 34th IAHR world congress ; 33rd Hydrology and Water Resources Symposium ; 10th Conference on Hydraulics in Water Engineering ; 26 June - 1 July 2011, Brisbane, Australia Y1 - 2011 SN - 978-0-85825-868-6 SP - 1179 EP - 1186 ER - TY - JOUR A1 - Cheenakula, Dheeraja A1 - Griebel, Kai A1 - Montag, David A1 - Grömping, Markus ED - Huang, Xiaowu T1 - Concept development of a mainstream deammonification and comparison with conventional process in terms of energy, performance and economical construction perspectives JF - Frontiers in Microbiology N2 - Deammonification for nitrogen removal in municipal wastewater in temperate and cold climate zones is currently limited to the side stream of municipal wastewater treatment plants (MWWTP). This study developed a conceptual model of a mainstream deammonification plant, designed for 30,000 P.E., considering possible solutions corresponding to the challenging mainstream conditions in Germany. In addition, the energy-saving potential, nitrogen elimination performance and construction-related costs of mainstream deammonification were compared to a conventional plant model, having a single-stage activated sludge process with upstream denitrification. The results revealed that an additional treatment step by combining chemical precipitation and ultra-fine screening is advantageous prior the mainstream deammonification. Hereby chemical oxygen demand (COD) can be reduced by 80% so that the COD:N ratio can be reduced from 12 to 2.5. Laboratory experiments testing mainstream conditions of temperature (8–20°C), pH (6–9) and COD:N ratio (1–6) showed an achievable volumetric nitrogen removal rate (VNRR) of at least 50 gN/(m3∙d) for various deammonifying sludges from side stream deammonification systems in the state of North Rhine-Westphalia, Germany, where m3 denotes reactor volume. Assuming a retained Norganic content of 0.0035 kgNorg./(P.E.∙d) from the daily loads of N at carbon removal stage and a VNRR of 50 gN/(m3∙d) under mainstream conditions, a resident-specific reactor volume of 0.115 m3/(P.E.) is required for mainstream deammonification. This is in the same order of magnitude as the conventional activated sludge process, i.e., 0.173 m3/(P.E.) for an MWWTP of size class of 4. The conventional plant model yielded a total specific electricity demand of 35 kWh/(P.E.∙a) for the operation of the whole MWWTP and an energy recovery potential of 15.8 kWh/(P.E.∙a) through anaerobic digestion. In contrast, the developed mainstream deammonification model plant would require only a 21.5 kWh/(P.E.∙a) energy demand and result in 24 kWh/(P.E.∙a) energy recovery potential, enabling the mainstream deammonification model plant to be self-sufficient. The retrofitting costs for the implementation of mainstream deammonification in existing conventional MWWTPs are nearly negligible as the existing units like activated sludge reactors, aerators and monitoring technology are reusable. However, the mainstream deammonification must meet the performance requirement of VNRR of about 50 gN/(m3∙d) in this case. KW - anammox KW - energy efficiency KW - mainstream deammonification KW - nitrogen elimination KW - wastewater Y1 - 2023 U6 - https://doi.org/10.3389/fmicb.2023.1155235 SN - 1664-302X VL - 14 IS - 11155235 SP - 1 EP - 15 PB - Frontiers ER - TY - CHAP A1 - Melzner, Jürgen A1 - Ferger, Martin ED - Krause, Thomas ED - Ulke, Bernd ED - Ferger, Martin T1 - Building Information Modeling T2 - Zahlentafeln für den Baubetrieb N2 - Durch die Einführung von Building Information Modeling (BIM) sowohl projektspezifisch als auch in ganze Unternehmungen hat die Baubranche einen weitreichenden Veränderungsprozess angestoßen. Building Information Modeling kann als eine Methode angesehen werden, um die Informationsasymmetrien zwischen den Projektbeteiligten so gering wie möglich zu halten. Y1 - 2024 SN - 978-3-658-41329-3 (Print) SN - 978-3-658-41330-9 (eBook) U6 - https://doi.org/10.1007/978-3-658-41330-9_15 SP - 1051 EP - 1073 PB - Springer Vieweg CY - Wiesbaden ER - TY - RPRT A1 - Thoma, Andreas A1 - Laarmann, Lukas A1 - Merkens, Torsten A1 - Franzke, Till A1 - Möhren, Felix A1 - Buttermann, Lilly A1 - van der Weem, Dirk A1 - Fischer, Maximilian A1 - Misch, Philipp A1 - Böhme, Mirijam A1 - Röth, Thilo A1 - Hebel, Christoph A1 - Ritz, Thomas A1 - Franke, Marina A1 - Braun, Carsten T1 - Entwicklung eines intermodalen Mobilitätskonzeptes für die Pilotregion NRW/Rhein-Maas Euregio und Schaffung voller Kundenakzeptanz durch Transfer von Standards aus dem PKW-Bereich auf ein Flugtaxi : Schlussbericht : Projektakronym: SkyCab (Kategorie B) : Laufzeit in Monaten: 6 : Hauptthema: Kategorie B: Innovative Ideen mit Bezug zu UAS/Flugtaxis Y1 - 2020 N1 - Förderkennzeichen BMVI 45UAS1027A-F PB - FH Aachen CY - Aachen ER - TY - CHAP A1 - Kerpen, Nils B. A1 - Schoonees, Talia A1 - Schlurmann, Torsten A1 - Valero, Daniel A1 - Bung, Daniel Bernhard T1 - waveSTEPS – Wellenauf- und Wellenüberlauf an getreppten Deckwerken T2 - 24. KFKI-Seminar 2019, 21.11.2019 Y1 - 2019 ER - TY - CHAP A1 - Lopes, Pedro A1 - Bung, Daniel Bernhard A1 - Leandro, Jorge A1 - Carvalho, Rita F. T1 - The effect of cross-waves in physical stepped spillway models T2 - E-proceedings of the 36th IAHR World Congress ; 28 June - 3 July, 2015, The Hague, the Netherlands Y1 - 2015 SP - 1 EP - 9 ER -