TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Bergmann, B. A1 - Waluga, C. A1 - Behr, M. A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Modeling and Numerical Simulation of Blood Damage Y1 - 2010 N1 - Posterpresentation ; Umbrella Symposium "Modelling and Simulation in Medicine, Engineering and Sciences", Forschungszentrum Jülich, January 18-20, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Finocchiaro, Thomas A1 - Heinke, Stefanie A1 - Leßmann, Marc T1 - Methods of design, simulation, and control for the development of new VAD/TAH concepts = Methoden zur Konstruktion, Simulation und Regelung für die Entwicklung von neuen VAD/TAH-Konzepten / Finocchiaro, Thomas ; Heinke, Stefanie ; Behbahani, Mehdi ; Leßma JF - Biomedizinische Technik / Biomedical Engineering. 54 (2009), H. 5 Y1 - 2009 SN - 0013-5585 N1 - Printausgabe in der Bereichsbibliothek Jülich vorhanden : 63 Z 471 SP - 269 EP - 281 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Nicolai, Mike A1 - Probst, Markus T1 - Towards Shape Optimization for Ventricular Assist Devices Using Parallel Stabilized FEM JF - NIC Symposium 2008 : symposium, 20 - 21 February 2008, Forschungszentrum Jülich ; proceedings / organized by John von Neumann Institute for Computing. Ed. by Gernot Münster; Dietrich Wolf; Manfred Kremer (ed.) Y1 - 2008 SN - 978-3-9810843-5-1 N1 - NIC series ; 39 SP - 325 EP - 332 PB - Forschungszentrum CY - Jülich ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Hormes, M. A1 - Steinseifer, U. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - A Review of Computational Fluid Dynamics Analysis of Blood Pumps JF - European Journal of Applied Mathematics. 20 (2009), H. 4 Y1 - 2009 SP - 363 EP - 397 PB - Cambridge Univ. Press CY - Cambridge ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Bischof, F. A1 - Wolf, G. E. T1 - Kranken Herzen helfen - Ingenieure und Informatiker entwickeln gemeinsam eine Miniaturblutpumpe / Behbahani, M. ; Behr, M. ; Bischof, F. ; Wolf, G. E. JF - RWTH-Themen (2007) Y1 - 2007 SN - 0179-079X SP - 44 EP - 46 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - CFD Analysis of MicroMed Debakey Pump and Hemolysis Prediction / Behbahani, M. ; Behr, M. ; Arora, D. ; Coronado, O. ; Pasquali, M. JF - Artificial Organs. 30 (2006), H. 11 Y1 - 2006 SN - 1525-1594 N1 - Abstracts 14th Congress of the International Society for Rotary Blood Pumps, Leuven, Belgium, August 31–September 2, 2006 ; S7-4 SP - A45 EP - A46 ER - TY - CHAP A1 - Behbahani, Mehdi T1 - An Experimental Study of Thrombocyte Reactions in Response to Biomaterial Surfaces and Varying Shear Stress T2 - Proceedings of the International Conference on Biomedical Engineering and Systems Prague, Czech Republic, August 14-15, 2014 Y1 - 2014 SP - Paper 125 ER - TY - THES A1 - Behbahani, Mehdi T1 - Modeling and Simulation of Shear-Dependent Platelet Reactions in Blood Vessels and Blood-Contacting Medical Devices Y1 - 2011 SN - 978-3-8439-0134-5 PB - Verlag Dr. Hut CY - München ER - TY - JOUR A1 - Becker, C. A1 - Wallang, C. A1 - Artmann, Gerhard A1 - Jakse, G. T1 - Mechanotransduction-bioreactor for tissue engineering of a ureter prosthesis JF - International Journal of Artificial Organs, The Y1 - 2008 SN - 0391-3988 N1 - Abstracts from the XXXV Congress of the European Society for Artificial Organs: 'Towards Future Biomedical Technologies' - ORAL PRESENTATIONS VL - 31 IS - 7 SP - 583 EP - 583 ER - TY - JOUR A1 - Bayer, Robin A1 - Temiz Artmann, Aysegül A1 - Digel, Ilya A1 - Falkenstein, Julia A1 - Artmann, Gerhard A1 - Creutz, Till A1 - Hescheler, Jürgen T1 - Mechano-pharmacological testing of L-Type Ca²⁺ channel modulators via human vascular celldrum model JF - Cellular Physiology and Biochemistry N2 - Background/Aims: This study aimed to establish a precise and well-defined working model, assessing pharmaceutical effects on vascular smooth muscle cell monolayer in-vitro. It describes various analysis techniques to determine the most suitable to measure the biomechanical impact of vasoactive agents by using CellDrum technology. Methods: The so-called CellDrum technology was applied to analyse the biomechanical properties of confluent human aorta muscle cells (haSMC) in monolayer. The cell generated tensions deviations in the range of a few N/m² are evaluated by the CellDrum technology. This study focuses on the dilative and contractive effects of L-type Ca²⁺ channel agonists and antagonists, respectively. We analyzed the effects of Bay K8644, nifedipine and verapamil. Three different measurement modes were developed and applied to determine the most appropriate analysis technique for the study purpose. These three operation modes are called, particular time mode" (PTM), "long term mode" (LTM) and "real-time mode" (RTM). Results: It was possible to quantify the biomechanical response of haSMCs to the addition of vasoactive agents using CellDrum technology. Due to the supplementation of 100nM Bay K8644, the tension increased approximately 10.6% from initial tension maximum, whereas, the treatment with nifedipine and verapamil caused a significant decrease in cellular tension: 10nM nifedipine decreased the biomechanical stress around 6,5% and 50nM verapamil by 2,8%, compared to the initial tension maximum. Additionally, all tested measurement modes provide similar results while focusing on different analysis parameters. Conclusion: The CellDrum technology allows highly sensitive biomechanical stress measurements of cultured haSMC monolayers. The mechanical stress responses evoked by the application of vasoactive calcium channel modulators were quantified functionally (N/m²). All tested operation modes resulted in equal findings, whereas each mode features operation-related data analysis. Y1 - 2020 U6 - http://dx.doi.org/10.33594/000000225 SN - 1421-9778 VL - 54 SP - 371 EP - 383 PB - Cell Physiol Biochem Press CY - Düsseldorf ER - TY - CHAP A1 - Bayer, Robin A1 - Hescheler, Jürgen A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül ED - Staat, Manfred ED - Erni, Daniel T1 - Treating arterial hypertension in a cell culture well T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH AachenW N2 - Hypertension describes the pathological increase of blood pressure, which is most commonly associated with the increase of vascular wall stiffness [1]. Referring to the “Deutsche Bluthochdruck Liga” this pathology shows a growing trend in our aging society. In order to find novel pharmacological and probably personalized treatments, we want to present a functional approach to study biomechanical properties of a human aortic vascular model. In this method review we will give an overview of recent studies which were carried out with the CellDrum technology [2] and underline the added value to already existing standard procedures known from the field of physiology. Herein described CellDrum technology is a system to measure functional mechanical properties of cell monolayers and thin tissue constructs in-vitro. Additionally, the CellDrum enables to elucidate the mechanical response of cells to pharmacological drugs, toxins and vasoactive agents. Due to its highly flexible polymer support, cells can also be mechanically stimulated by steady and cyclic biaxial stretching. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 5 EP - 6 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - THES A1 - Bayer, Robin T1 - Development of a novel in-vitro vascular model for determination of physiological and pathophysiological mechanobiology Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:38-362212 N1 - Dissertation, Universität zu Köln, 2021 PB - Universität zu Köln CY - Köln ER - TY - JOUR A1 - Baumann, Marcus A1 - Schwarz, Sonja A1 - Kotliar, Konstantin A1 - Eynatten, Maximilian von A1 - Trucksaess, Arno A1 - Burckhardt, Klaus A1 - Lutz, Jens A1 - Heemann, Uwe A1 - Lanzl, Ines T1 - Non-diabetic chronic kidney disease influences retinal microvasculature JF - Kidney and Blood Pressure Research Y1 - 2009 SN - 1423-0143 VL - 32 IS - 6 SP - 428 EP - 433 PB - - ER - TY - JOUR A1 - Bassam, Rasha A1 - Hescheler, Jürgen A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Digel, Ilya T1 - Effects of spermine NONOate and ATP on the thermal stability of hemoglobin JF - BMC Biophysics N2 - Background Minor changes in protein structure induced by small organic and inorganic molecules can result in significant metabolic effects. The effects can be even more profound if the molecular players are chemically active and present in the cell in considerable amounts. The aim of our study was to investigate effects of a nitric oxide donor (spermine NONOate), ATP and sodium/potassium environment on the dynamics of thermal unfolding of human hemoglobin (Hb). The effect of these molecules was examined by means of circular dichroism spectrometry (CD) in the temperature range between 25°C and 70°C. The alpha-helical content of buffered hemoglobin samples (0.1 mg/ml) was estimated via ellipticity change measurements at a heating rate of 1°C/min. Results Major results were: 1) spermine NONOate persistently decreased the hemoglobin unfolding temperature T u irrespectively of the Na + /K + environment, 2) ATP instead increased the unfolding temperature by 3°C in both sodium-based and potassium-based buffers and 3) mutual effects of ATP and NO were strongly influenced by particular buffer ionic compositions. Moreover, the presence of potassium facilitated a partial unfolding of alpha-helical structures even at room temperature. Conclusion The obtained data might shed more light on molecular mechanisms and biophysics involved in the regulation of protein activity by small solutes in the cell. KW - Nitric Oxide Donor KW - NONOate KW - Circular Dichroism KW - Nitric Oxide Y1 - 2012 U6 - http://dx.doi.org/10.1186/2046-1682-5-16 SN - 2046-1682 VL - 5 PB - BioMed Central CY - London ER - TY - JOUR A1 - Bassam, Rasha A1 - Digel, Ilya A1 - Hescheler, Jürgen A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Effects of spermine NONOate and ATP on protein aggregation: light scattering evidences JF - BMC Biophysics Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?10.1186/2046-1682-6-1 SN - 2046-1682 SP - 1 EP - 14 PB - BioMed Central CY - London ER - TY - CHAP A1 - Bassam, Rasha A1 - Digel, Ilya A1 - Artmann, Gerhard T1 - Effect of nitric oxide on protein thermal stability : [abstract] N2 - As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not. KW - Stickstoffmonoxid KW - Proteine KW - Hämoglobin KW - nitric oxide gas KW - protein KW - hemoglobin Y1 - 2009 ER - TY - JOUR A1 - Bassam, Rasha A1 - Artmann, Gerhard A1 - Hescheler, Jürgen A1 - Graef, T. A1 - Temiz Artmann, Aysegül A1 - Porst, Dariusz A1 - Linder, Peter A1 - Kayser, Peter A1 - Arinkin, Vladimir A1 - Gossmann, Matthias A1 - Digel, Ilya T1 - Alterations in human hemoglobin structure related to red blood cell storage N2 - The importance of the availability of stored blood or blood cells, respectively, for urgent transfusion cannot be overestimated. Nowadays, blood storage becomes even more important since blood products are used for epidemiological studies, bio-technical research or banked for transfusion purposes. Thus blood samples must not only be processed, stored, and shipped to preserve their efficacy and safety, but also all parameters of storage must be recorded and reported for Quality Assurance. Therefore, blood banks and clinical research facilities are seeking more accurate, automated means for blood storage and blood processing. KW - Hämoglobin KW - Hämoglobinstruktur KW - Blutzellenlagerung KW - Hemoglobin structure KW - Red blood cell storage Y1 - 2011 ER - TY - THES A1 - Bassam Abduljabbar, Rasha T1 - Physikalisch-chemische Steuerung der Proteinstabilität in biologischen Systemen T1 - Physico-chemical management of protein stability in biological systems Y1 - 2015 ER - TY - JOUR A1 - Baroud, G. A1 - Wu, J.Z. A1 - Bohner, M A1 - Sponagel, Stefan A1 - Steffen, T. T1 - How to determine the permeability for cement infiltration into osteoporotic cancellous bone JF - Medical Engineering & Physics. 25 (2003), H. 4 N2 - Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice. KW - Osteoporose KW - Permeabilität KW - Viskose Strömung KW - Viskosität KW - Vertebroplastie KW - Cement infiltration KW - Vertebroplasty KW - Osteoporosis KW - Permeability KW - Experiment KW - Analysis KW - Viscous flow Y1 - 2003 SN - 1350-4533 SP - 283 EP - 288 ER - TY - JOUR A1 - Balakirski, Galina A1 - Kotliar, Konstantin A1 - Pauly, Karolin J. A1 - Krings, Laura K. A1 - Rübben, Albert A1 - Baron, Jens M. A1 - Schmitt, Laurenz T1 - Surgical Site Infections After Dermatologic Surgery in Immunocompromised Patients: A Single-Center Experience JF - Dermatologic Surgery N2 - BACKGROUND Immunosuppression is often considered as an indication for antibiotic prophylaxis to prevent surgical site infections (SSI) while performing skin surgery. However, the data on the risk of developing SSI after dermatologic surgery in immunosuppressed patients are limited. PATIENTS AND METHODS All patients of the Department of Dermatology and Allergology at the University Hospital of RWTH Aachen in Aachen, Germany, who underwent hospitalization for a dermatologic surgery between June 2016 and January 2017 (6 months), were followed up after surgery until completion of the wound healing process. The follow-up addressed the occurrence of SSI and the need for systemic antibiotics after the operative procedure. Immunocompromised patients were compared with immunocompetent patients. The investigation was conducted as a retrospective analysis of patient records. RESULTS The authors performed 284 dermatologic surgeries in 177 patients. Nineteen percent (54/284) of the skin surgery was performed on immunocompromised patients. The most common indications for surgical treatment were nonmelanoma skin cancer and malignant melanomas. Surgical site infections occurred in 6.7% (19/284) of the cases. In 95% (18/19), systemic antibiotic treatment was needed. Twenty-one percent of all SSI (4/19) were seen in immunosuppressed patients. CONCLUSION According to the authors' data, immunosuppression does not represent a significant risk factor for SSI after dermatologic surgery. However, larger prospective studies are needed to make specific recommendations on the use of antibiotic prophylaxis while performing skin surgery in these patients. The available data on complications after dermatologic surgery have improved over the past years. Particularly, additional risk factors have been identified for surgical site infections (SSI). Purulent surgical sites, older age, involvement of head, neck, and acral regions, and also the involvement of less experienced surgeons have been reported to increase the risk of the SSI after dermatologic surgeries.1 In general, the incidence of SSI after skin surgery is considered to be low.1,2 However, antibiotics in dermatologic surgeries, especially in the perioperative setting, seem to be overused,3,4 particularly regarding developing antibiotic resistances and side effects. Immunosuppression has been recommended to be taken into consideration as an additional indication for antibiotic prophylaxis to prevent SSI after skin surgery in special cases.5,6 However, these recommendations do not specify the exact dermatologic surgeries, and were not specifically developed for dermatologic surgery patients and treatments, but adopted from other surgical fields.6 According to the survey conducted on American College of Mohs Surgery members in 2012, 13% to 29% of the surgeons administered antibiotic prophylaxis to immunocompromised patients to prevent SSI while performing dermatologic surgery on noninfected skin,3 although this was not recommended by Journal of the American Academy of Dermatology Advisory Statement. Indeed, the data on the risk of developing SSI after dermatologic surgery in immunosuppressed patients are limited. However, it is possible that due to the insufficient evidence on the risk of SSI occurrence in this patient group, dermatologic surgeons tend to overuse perioperative antibiotic prophylaxis. To make specific recommendations on the use of antibiotic prophylaxis in immunosuppressed patients in the field of skin surgery, more information about the incidence of SSI after dermatologic surgery in these patients is needed. The aim of this study was to fill this data gap by investigating whether there is an increased risk of SSI after skin surgery in immunocompromised patients compared with immunocompetent patients. Y1 - 2018 U6 - http://dx.doi.org/10.1097/DSS.0000000000001615 IS - 44 (12) SP - 1525 EP - 1536 PB - Wolters Kluwer ER - TY - CHAP A1 - Baader, Fabian A1 - Reiswich, M. A1 - Bartsch, M. A1 - Keller, D. A1 - Tiede, E. A1 - Keck, G. A1 - Demircian, A. A1 - Friedrich, M. A1 - Dachwald, Bernd A1 - Schüller, K. A1 - Lehmann, R. A1 - Chojetzki, R. A1 - Durand, C. A1 - Rapp, L. A1 - Kowalski, Julia A1 - Förstner, R. T1 - VIPER - Student research on extraterrestrical ice penetration technology T2 - Proceedings of the 2nd Symposium on Space Educational Activities N2 - Recent analysis of scientific data from Cassini and earth-based observations gave evidence for a global ocean under a surrounding solid ice shell on Saturn's moon Enceladus. Images of Enceladus' South Pole showed several fissures in the ice shell with plumes constantly exhausting frozen water particles, building up the E-Ring, one of the outer rings of Saturn. In this southern region of Enceladus, the ice shell is considered to be as thin as 2 km, about an order of magnitude thinner than on the rest of the moon. Under the ice shell, there is a global ocean consisting of liquid water. Scientists are discussing different approaches the possibilities of taking samples of water, i.e. by melting through the ice using a melting probe. FH Aachen UAS developed a prototype of maneuverable melting probe which can navigate through the ice that has already been tested successfully in a terrestrial environment. This means no atmosphere and or ambient pressure, low ice temperatures of around 100 to 150K (near the South Pole) and a very low gravity of 0,114 m/s^2 or 1100 μg. Two of these influencing measures are about to be investigated at FH Aachen UAS in 2017, low ice temperature and low ambient pressure below the triple point of water. Low gravity cannot be easily simulated inside a large experiment chamber, though. Numerical simulations of the melting process at RWTH Aachen however are showing a gravity dependence of melting behavior. Considering this aspect, VIPER provides a link between large-scale experimental simulations at FH Aachen UAS and numerical simulations at RWTH Aachen. To analyze the melting process, about 90 seconds of experiment time in reduced gravity and low ambient pressure is provided by the REXUS rocket. In this time frame, the melting speed and contact force between ice and probes are measured, as well as heating power and a two-dimensional array of ice temperatures. Additionally, visual and infrared cameras are used to observe the melting process. Y1 - 2018 SP - 1 EP - 6 ER - TY - CHAP A1 - Baader, Fabian A1 - Keller, Denis A1 - Lehmann, Raphael A1 - Gerber, Lukas A1 - Reiswich, Martin A1 - Dachwald, Bernd A1 - Förstner, Roger T1 - Operating melting probes for ice penetration under sublimation conditions and in reduced gravity on a sounding rocket T2 - Proceedings of the 24th ESA Symposium on European Rocket and Balloon Programmes and related Research Y1 - 2019 SN - 0379-6566 N1 - 24th PAC Symposium 2019 ER - TY - CHAP A1 - Azat, Seitkhan A1 - Kerimkulova, Almagul R. A1 - Mansurov, Zulkhair A. A1 - Adekenov, Sergazy A1 - Artmann, Gerhard T1 - The Use of Fusicoccin as Anticancer Compound T2 - Carbon Nanomaterials in Biomedicine and the Environment N2 - The problem of creation and use of sorption materials is of current interest for the practice of the modern medicine and agriculture. Practical importance is production of a biostimulant using a carbon sorbent for a significant increase in productivity, which is very relevant for the regions of Kazakhstan. It is known that a plant phytohormone—fusicoccin—in nanogram concentrations transforms cancer cells to the state of apoptosis. In this regard, there is a scientific practical interest in the development of a highly efficient method for producing fusicoccin from extract of germinated wheat seeds. According to the results of computer modeling, cleaning composite components of fusicoccin using microporous carbon adsorbents not suitable as the size of the molecule of fusicoccin more than micropores and the optimum pore size for purification of constituents of fusicoccin was determined by computer simulation. Y1 - 2020 SN - 978-0-429-42864-7 U6 - http://dx.doi.org/10.1201/9780429428647-8 SP - 149 EP - 172 PB - Jenny Stanford Publishing CY - New York ER - TY - CHAP A1 - Azar, Fouad A1 - Digel, Ilya ED - Staat, Manfred ED - Erni, Daniel T1 - Utilization of fluorescence spectroscopy and neural networks in clinical analysis T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Fluorescence topography of human urine in combination with learning algorithms can provide a variant pattern recognition method in analytical clinical chemistry and, eventually, diagnosis. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 40 EP - 41 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Attar, Mandana Hossein Zadeh A1 - Merk, Hans F. A1 - Kotliar, Konstantin A1 - Wurpts, Gerda A1 - Röseler, Stefani A1 - Moll-Slodowy, Silke A1 - Plange, Johann A1 - Baron, Jens Malte A1 - Balakirski, Galina T1 - The CD63 basophil activation test as a diagnostic tool for assessing autoimmunity in patients with chronic spontaneous urticaria JF - European Journal of Dermatology Y1 - 2019 U6 - http://dx.doi.org/10.1684/ejd.2019.3680 VL - 29 IS - 6 SP - 614 EP - 618 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zhou-Stache, J. A1 - Buettner, R. A1 - Mittermayer, C. [u.a.] T1 - Inhibition of TNF-alpha induced cell death in HUVEC and Jurkat cells by protocatechuic acid. Zhou-Stache, J.; Buettner, R.; Artmann, Gerhard Michael; Mittermayer, C.; Bosserhoff, A. K. JF - Medical and Biological Engineering and Computing. 40 (2002), H. 6 Y1 - 2002 SN - 0140-0118 SP - 698 EP - 703 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Stadler, Andreas M. T1 - Physical discontinuities at body temperature in human red blood cells / Artmann, GM ; Zerlin, K ; Digel, I ; Stadler, A ; Zaccai, G ; Temiz, AA JF - Tissue Engineering. 13 (2007), H. 7 Y1 - 2007 SN - 1076-3279 N1 - TERMIS-EU Meeting Abstracts London, UK September 4–7, 2007 SP - 1778 EP - 1778 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zerlin, Kay A1 - Digel, Ilya T1 - Hemoglobin Senses Body Temperature JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 415 EP - 447 PB - Springer CY - Berlin ER - TY - JOUR A1 - Artmann, Gerhard A1 - Trzewik, Jürgen A1 - Ates, M. T1 - A novel method to quantify mechanical tension in cell monolayers. Trzewik, Jürgen; Ates, M., Artmann, Gerhard Michael JF - Biomedizinische Technik. 47 (2002), H. Suppl. 1. Pt. 1 Y1 - 2002 SN - 0013-5585 N1 - Druckausgabe unter 63 Z 47 vorhanden SP - 379 EP - 381 ER - TY - BOOK A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül A1 - Zhubanova, Azhar A. A1 - Digel, Ilya ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Biological, physical and technical basics of cell engineering Y1 - 2018 SN - 978-981-10-7903-0 PB - Springer CY - Singapore ER - TY - CHAP A1 - Artmann, Gerhard A1 - Stadler, Andreas M. A1 - Embs, Jan P. A1 - Zaccai, Giuseppe A1 - Büldt, Georg A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - The crucial role of water in a phase transition of hemoglobin at body temperature : [abstract] N2 - The observation of a temperature transition of hemoglobin occurring at a critical temperature close to body temperature KW - Hämoglobin KW - Erythrozyt KW - Körpertemperatur Y1 - 2010 ER - TY - CHAP A1 - Artmann, Gerhard A1 - Meruvu, Haritha A1 - Kizildag, Sefa A1 - Temiz Artmann, Aysegül ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Functional Toxicology and Pharmacology Test of Cell Induced Mechanical Tensile Stress in 2D and 3D Tissue Cultures T2 - Biological, Physical and Technical Basics of Cell Engineering N2 - Mechanical forces/tensile stresses are critical determinants of cellular growth, differentiation and migration patterns in health and disease. The innovative “CellDrum technology” was designed for measuring mechanical tensile stress of cultured cell monolayers/thin tissue constructs routinely. These are cultivated on very thin silicone membranes in the so-called CellDrum. The cell layers adhere firmly to the membrane and thus transmit the cell forces generated. A CellDrum consists of a cylinder which is sealed from below with a 4 μm thick, biocompatible, functionalized silicone membrane. The weight of cell culture medium bulbs the membrane out downwards. Membrane indentation is measured. When cells contract due to drug action, membrane, cells and medium are lifted upwards. The induced indentation changes allow for lateral drug induced mechanical tension quantification of the micro-tissues. With hiPS-induced (human) Cardiomyocytes (CM) the CellDrum opens new perspectives of individualized cardiac drug testing. Here, monolayers of self-beating hiPS-CMs were grown in CellDrums. Rhythmic contractions of the hiPS-cells induce membrane up-and-down deflections. The recorded cycles allow for single beat amplitude, single beat duration, integration of the single beat amplitude over the beat time and frequency analysis. Dose effects of agonists and antagonists acting on Ca2+ channels were sensitively and highly reproducibly observed. Data were consistent with published reference data as far as they were available. The combination of the CellDrum technology with hiPS-Cardiomyocytes offers a fast, facile and precise system for pharmacological and toxicological studies. It allows new preclinical basic as well as applied research in pharmacolgy and toxicology. Y1 - 2018 SN - 978-981-10-7904-7 U6 - http://dx.doi.org/10.1007/978-981-10-7904-7_7 SP - 157 EP - 192 PB - Springer CY - Singapore ER - TY - PAT A1 - Artmann, Gerhard A1 - Linder, Peter A1 - Bayer, Robin A1 - Gossmann, Matthias T1 - Celldrum electrode arrangement for measuring mechanical stress [Patent of invention] N2 - The invention pertains to a CellDrum electrode arrangement for measuring mechanical stress, comprising a mechanical holder (1 ) and a non-conductive membrane (4), whereby the membrane (4) is at least partially fixed at its circumference to the mechanical holder (1), keeping it in place when the membrane (4) may bend due to forces acting on the membrane (4), the mechanical holder (1) and the membrane (4) forming a container, whereby the membrane (1) within the container comprises an cell- membrane compound layer or biological material (3) adhered to the deformable membrane 4 which in response to stimulation by an agent may exert mechanical stress to the membrane (4) such that the membrane bending stage changes whereby the container may be filled with an electrolyte, whereby an electric contact (2) is arranged allowing to contact said electrolyte when filled into to the container, whereby within a predefined geometry to the fixing of the membrane (4) an electrode (7) is arranged, whereby the electrode (7) is electrically insulated with respect to the electric contact (2) as well as said electrolyte, whereby mechanical stress due to an agent may be measured as a change in capacitance. Y1 - 2017 N1 - Patent auch unter EP3403090, CN109477828, US2019033245 und LU92948 veröffentlicht. PB - WIPO CY - Geneva ER - TY - JOUR A1 - Artmann, Gerhard A1 - Hueck, Isgard S. A1 - Rossiter, Katharine A1 - Schmid-Schönbein, Geert W. T1 - Fluid Shear Attenuates Endothelial Pseudopodia Formation into the Capillary Lumen / Hueck, Isgard S. ; Rossiter, Katharine ; Artman, Gerhard M. ; Schmid-Schönbein, Geert W. JF - Microcirculation. 15 (2008), H. 6 Y1 - 2008 SN - 1549-8719 SP - 531 EP - 542 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Zerlin, Kay A1 - Maggakis-Kelemen, Christina A1 - Linder, Peter A1 - Porst, Dariusz A1 - Kayser, Peter A1 - Stadler, David A1 - Dikta, Gerhard A1 - Temiz Artmann, Aysegül T1 - Hemoglobin senses body temperature JF - European Biophysics Journal Y1 - 2009 SN - 0175-7571 VL - 38 IS - 5 SP - 589 EP - 600 ER - TY - CHAP A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Linder, Peter A1 - Temiz Artmann, Aysegül T1 - Biophysical and Engineering Contributions to Plant Research N2 - Tests with palm tree leaves have just started yet and scan data are in the process to be analyzed. The final goal of future project for palm tree gender and species recognition will be to develop optical scanning technology to be applied to date palm tree leaves for in–situ screening purposes. Depending on the software used and the particular requirements of the users the technology potentially shall be able to identify palm tree diseases, palm tree gender, and species of young date palm trees by scanning leaves. KW - Pflanzenphysiologie KW - Dattel KW - Pflanzenscanner KW - plant scanner KW - date palm tree Y1 - 2011 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Linder, Peter A1 - Porst, Dariusz T1 - Mechanism of haemoglobin sensing body temperature JF - Tissue Engineering Part A. 14 (2008), H. 5 Y1 - 2008 SN - 1937-3341 N1 - TERMIS EU 2008 Porto Meeting June 22–26, 2008 Porto Congress Center–Alfândega Portugal SP - 754 EP - 754 ER - TY - RPRT A1 - Artmann, Gerhard A1 - Bäumler, H. T1 - Pharmamikrocontainer mit designgesteuerter Permeabilität als Transporter für ausgewählte Pharmaka. Ein Gemeinschaftsprojekt im Forschungsschwerpunkt "Celluar Engineering" [Laufzeit: 01.09.2000 - 28.02.2002] Y1 - 2002 PB - FH Aachen CY - Jülich ER - TY - JOUR A1 - Artmann, Gerhard A1 - Burns, Laura A1 - Canaves, Jaume M. A1 - Temiz Artmann, Aysegül T1 - Circular dichroism spectra of human hemoglobin reveal a reversible structural transition at body temperature JF - European Biophysics Journal. 33 (2004), H. 6 Y1 - 2004 SN - 1432-1017 SP - 490 EP - 496 ER - TY - BOOK A1 - Artmann, Gerhard T1 - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 PB - Springer CY - Berlin ER - TY - BOOK A1 - Artmann, Gerhard T1 - Stem cell engineering : principles and applications / Gerhard M. Artmann ... eds. Y1 - 2011 SN - 978-3-642-11864-7 PB - Springer CY - Berlin [u.a.] ER - TY - RPRT A1 - Artmann, Gerhard T1 - HPBioforce: Integrierte und automatisierte Screening Plattform eines 96-Well-Hochdurchsatz-Testsystems zur funktionellen Kraftmessung an einige um dicken Zell- und Gewebeschichten für die Arzneimittelforschung : gemeinsamer Abschlussbericht der FH Aachen, Hitec Zang GmbH, IKFE Mainz, IKFE Berlin und der Dr. Gerhard Schmidt GmbH zum InnoNet-Projekt ... ; Programm "Förderung von innovativen Netzwerken" (InnoNet) des Bundesministerium für Wirtschaft und Technologie (BMWi) ; Laufzeit: 01.05.2007 bis 31.12.2010 Y1 - 2011 U6 - http://dx.doi.org/10.2314/GBV:68757076X N1 - Förderkennzeichen BMWi 16IN0536. - Verbund-Nr. 01056220 PB - Technische Informationsbibliothek u. Universitätsbibliothek CY - Aachen [u.a.] ER - TY - RPRT A1 - Artmann, Gerhard T1 - FhprofUnd EasyBioforce Abschlussbericht : Miniaturisierte, integrierte und automatisierte Screening Plattform eines 36-Well-Hochdurchsatz-Testsystems zur funktionellen Kraftmessung an Zell- und Gewebeschichten für die Arzneimittelforschung : Laufzeit des Vorhabens: 01.03.2007 - 31.12.2010 Y1 - 2011 U6 - http://dx.doi.org/10.2314/GBV:782964621 N1 - Förderkennzeichen BMBF 1760X07 PB - Technische Informationsbibliothek u. Universitätsbibliothek CY - Aachen ER - TY - RPRT A1 - Artmann, Gerhard T1 - Escherichia Coli Infektion und Zellschädigung - Wie perfekt wirken Antibiotika? : Abschlussbericht zum Projekt 1703701 Y1 - 2004 U6 - http://dx.doi.org/10.2314/GBV:482527137 PB - Technische Informationsbibliothek u. Universitätsbibliothek CY - Jülich ER - TY - RPRT A1 - Artmann, Gerhard T1 - Plant mutant scanner : Hochdurchsatzscanner zur Charakterisierung von Pflanzenmutanten. Abschlussbericht ; FHprofUnd ; PhytoScan ; Laufzeit des Vorhabens: 01.07.2008 - 30.06.2011 Y1 - 2011 U6 - http://dx.doi.org/10.2314/GBV:747569150 N1 - Förderkennzeichen BMBF 1736X08 PB - Technische Informationsbibliothek u. Universitätsbibliothek CY - Aachen ER - TY - JOUR A1 - Arinkin, Vladimir A1 - Digel, Ilya A1 - Porst, Dariusz A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Phenotyping date palm varieties via leaflet cross-sectional imaging and artificial neural network application JF - BMC bioinformatics N2 - Background True date palms (Phoenix dactylifera L.) are impressive trees and have served as an indispensable source of food for mankind in tropical and subtropical countries for centuries. The aim of this study is to differentiate date palm tree varieties by analysing leaflet cross sections with technical/optical methods and artificial neural networks (ANN). Results Fluorescence microscopy images of leaflet cross sections have been taken from a set of five date palm tree cultivars (Hewlat al Jouf, Khlas, Nabot Soltan, Shishi, Um Raheem). After features extraction from images, the obtained data have been fed in a multilayer perceptron ANN with backpropagation learning algorithm. Conclusions Overall, an accurate result in prediction and differentiation of date palm tree cultivars was achieved with average prediction in tenfold cross-validation is 89.1% and reached 100% in one of the best ANN. Y1 - 2014 U6 - http://dx.doi.org/10.1186/1471-2105-15-55 SN - 1471-2105 VL - 15 IS - 55 SP - 1 EP - 8 ER - TY - CHAP A1 - Arinkin, Vladimir A1 - Digel, Ilya T1 - Water bridge phenomenon : [abstract] N2 - One of interesting but not well known water properties is related to appearance of highly ordered structures in response to strong electrical field. In 1893 Sir William Armstrong placed a cotton thread between two wine glasses filled with chemically pure water. When high DC voltage was applied between the glasses, a connection consisting of water formed, producing a "water bridge" KW - Hydrodynamik KW - Elektrodynamik KW - Wasserbrücke KW - water bridge phenomenon Y1 - 2009 ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Peper, Andreas A1 - Bierbaum, Stefanie A1 - Albracht, Kirsten T1 - Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain JF - Journal of Biomechanics N2 - The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.jbiomech.2010.08.014 SN - 0021-9290 VL - 43 IS - 16 SP - 3073 EP - 3079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Mademli, Lida A1 - Albracht, Kirsten T1 - Plasticity of the human tendon to short and long-term mechanical loading JF - Exercise and Sport Sciences Reviews Y1 - 2009 U6 - http://dx.doi.org/10.1097/JES.0b013e31819c2e1d SN - 1538-3008 VL - 37 IS - 2 SP - 66 EP - 72 ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Albracht, Kirsten T1 - Adaptational responses of the human Achilles tendon by modulation of the applied cyclic strain magnitude JF - Journal of Experimental Biology Y1 - 2007 U6 - http://dx.doi.org/10.1242/jeb.003814 SN - 0022-0949 VL - 210 IS - 15 SP - 2743 EP - 2753 ER -