TY - JOUR A1 - Warmer, Johannes A1 - Wagner, Patrick A1 - Schöning, Michael Josef A1 - Kaul, Peter T1 - Detection of triacetone triperoxide using temperature cycled metal-oxide semiconductor gas sensors JF - Physica status solidi (a) Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431882 SN - 1862-6319 VL - 212 IS - 6 SP - 1289 EP - 1298 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Delle, Lotta E. A1 - Huck, Christina A1 - Bäcker, Matthias A1 - Müller, Frank A1 - Grandthyll, Samuel A1 - Jacobs, Karin A1 - Lilischkis, Rainer A1 - Vu, Xuan T. A1 - Schöning, Michael Josef A1 - Wagner, Patrick A1 - Thoelen, Roland A1 - Weil, Maryam A1 - Ingebrandt, Sven T1 - Impedimetric immunosensor for the detection of histamine based on reduced graphene oxide JF - Physica status solidi (a) Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431863 SN - 1862-6319 VL - 212 IS - 6 SP - 1327 EP - 1334 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Timme, Michael T1 - Versagung von Pkh trotz Zulassung der Revi­sion wegen grundsätzlicher Bedeutung JF - Neue Juristische Wochenschrift (NJW) Y1 - 2015 SN - 0341-1915 IS - 30 SP - 2173 EP - 2175 PB - Beck CY - München ER - TY - CHAP A1 - Wallnöfer, Armin A1 - Drath, Rainer A1 - Hüning, Felix T1 - Was ist Funktionales Engineering? Einordnung, Definition, Randbedingungen T2 - Automation 2015 : 16. Branchentreff der Mess- und Automatisierungstechnik, 11. und 12. Juni 2015, Baden-Baden / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2015 SN - 978-3-18-092258-4 PB - VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Kümmell, Steffen A1 - Hillgärtner, Michael T1 - Inductive charging comfortable and nonvisible charging stations for urbanised areas T2 - E-Mobility in Europe : trends and good practice N2 - For a wide acceptance of E-Mobility, a well-developed charging infrastructure is needed. Conductive charging stations, which are today’s state of the art, are of limited suitability for urbanised areas, since they cause a significant diversification in townscape. Furthermore, they might be destroyed by vandalism. Besides for those urbanistic reasons, inductive charging stations are a much more comfortable alternative, especially in urbanised areas. The usage of conductive charging stations requires more or less bulky charging cables. The handling of those standardised charging cables, especially during poor weather conditions, might cause inconvenience, such as dirty clothing etc. Wireless charging does not require visible and vandalism vulnerable charge sticks. No wired connection between charging station and vehicle is needed, which enable the placement below the surface of parking spaces or other points of interest. Inductive charging seems to be the optimal alternative for E-Mobility, as a high power transfer can be realised with a manageable technical and financial effort. For a well-accepted and working public charging infrastructure in urbanised areas it is essential that the infrastructure fits the vehicles’ needs. Hence, a well-adjusted standardisation of the charging infrastructure is essential. This is carried out by several IEC (International Electrotechnical Commission) and national standardisation committees. To ensure an optimised technical solution for future’s inductive charging infrastructures, several field tests had been carried out and are planned in near future. KW - E-mobility KW - Inductive charging KW - Charging stations KW - Urban areas Y1 - 2015 SN - 978-3-319-13193-1 U6 - https://doi.org/10.1007/978-3-319-13194-8_16 SP - 297 EP - 309 PB - Springer CY - Cham [u.a.] ER - TY - JOUR A1 - Takenaga, Shoko A1 - Schneider, Benno A1 - Erbay, E. A1 - Biselli, Manfred A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef A1 - Wagner, Torsten T1 - Fabrication of biocompatible lab-on-chip devices for biomedical applications by means of a 3D-printing process JF - Physica status solidi (a) N2 - A new microfluidic assembly method for semiconductor-based biosensors using 3D-printing technologies was proposed for a rapid and cost-efficient design of new sensor systems. The microfluidic unit is designed and printed by a 3D-printer in just a few hours and assembled on a light-addressable potentiometric sensor (LAPS) chip using a photo resin. The cell growth curves obtained from culturing cells within microfluidics-based LAPS systems were compared with cell growth curves in cell culture flasks to examine biocompatibility of the 3D-printed chips. Furthermore, an optimal cell culturing within microfluidics-based LAPS chips was achieved by adjusting the fetal calf serum concentrations of the cell culture medium, an important factor for the cell proliferation. Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201532053 SN - 1862-6319 VL - 212 IS - 6 SP - 1347 EP - 1352 PB - Wiley CY - Weinheim ER - TY - BOOK A1 - Vismann, Ulrich T1 - Wendehorst Beispiele aus der Baupraxis / Ulrich Vismann (Hrsg.). - 5., durchges. und aktualis. Aufl. Y1 - 2015 SN - 978-3-658-01680-7 (print) ; 978-3-658-01681-4 (e-Book) U6 - https://doi.org/10.1007/978-3-658-01681-4 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Vismann, Ulrich A1 - Schüller, Michael T1 - Stahlbetonbau T2 - Wendehorst Beispiele aus der Baupraxis. / 5. Auflage N2 - Das Kapitel Stahlbetonbau besteht aus einer Formelsammlung (Teil A) sowie einem Praxisbeispiel (Teil B). In dem Praxisbeispiel werden exemplarisch die erforderlichen Rechenschritte und Nachweise zur Bemessung im GZT und GZG nach Eurocode 2 [1] vorgestellt. Die Hinweise im Text beziehen sich, soweit nicht explizit erwähnt, auf Wendehorst, Bautechnische Zahlentafeln, 35. Auflage, „Stahlbeton- und Spannbetonbau nach Eurocode 2“ [2]. Die zum Praxisbeispiel zugehörigen Konstruktions- und Bewehrungszeichnungen stehen im Onlineportal zu diesem Buch zum kostenlosen Download bereit (siehe unter www.springer.com). Y1 - 2015 SN - 978-3-658-01680-7 ; 978-3-658-01681-4 U6 - https://doi.org/10.1007/978-3-658-01681-4_9 SP - 243 EP - 322 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Feiser, Johannes T1 - Geotechnik T2 - Wendehorst Beispiele aus der Baupraxis. / 5. Auflage Y1 - 2015 SN - 978-3-658-01689-0 ; 978-3-410-24199-7 U6 - https://doi.org/10.1007/978-3-658-01681-4_14 SP - 547 EP - 598 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Strohmeier, Andreas T1 - Siedlungswasserwirtschaft T2 - Wendehorst Beispiele aus der Baupraxis. / 5. Auflage N2 - Nachfolgende Ausführungen und Berechnungsbeispiele beziehen sich auf Kapitel 19 Siedlungswasserwirtschaft im „Wendehorst: Bautechnische Zahlentafeln 35. Auflage 2015“ (abgekürzt: BZ). Für den Bau von Anlagen der Siedlungswasserwirtschaft sind ebenso die Grundlagen der Hydraulik zu berücksichtigen. Aus diesem Grunde sind auch die entsprechenden Ausführungen zur Hydraulik zu beachten. Y1 - 2015 SN - 978-3-658-01689-0 ; 978-3-410-24199-7 U6 - https://doi.org/10.1007/978-3-658-01681-4_16 SP - 635 EP - 678 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Biener, Ernst T1 - Abfallwirtschaft T2 - Wendehorst Beispiele aus der Baupraxis. - 5. Aufl. Y1 - 2015 SN - 978-3-658-01689-0 ; 978-3-410-24199-7 U6 - https://doi.org/10.1007/978-3-658-01681-4_17 SP - 680 EP - 723 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Oberländer, Jan A1 - Kirchner, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Strategies in developing thin-film sensors for monitoring aseptic food processes : Theoretical considerations and investigations of passivation materials JF - Electrochimica Acta N2 - The sterilization of packages in aseptic food processes is highly significant to maintain a consumer-safe product with extended shelf-life. Today, the sterilization of food packages is predominantly accomplished by gaseous hydrogen peroxide (H2O2) in combination with heat. In order to monitor this sterilization process, calorimetric gas sensors as differential set-up of two platinum temperature sensors representing a catalytically active (additionally deposition of MnO2) and a passive segment have been recently developed. The temperature rise of the exothermic decomposition serves as an indicator of the present H2O2 concentration. In the present work, a theoretical approach considering the sensor’s thermochemistry and physical transport phenomena was formulated to evaluate the temperature rise based on the energy content of gaseous H2O2. In a further part of this work, three polymers have been analyzed with respect to their application as passivation materials. The examined polymers are photoresist SU-8, perfluoroalkoxy (PFA) and fluorinated ethylene propylene (FEP). Thermal analyses by means of differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) have been conducted to determine the operation limits of the polymers. The overall chemical resistance and stability of the polymers against the harsh environmental conditions during the sterilization process have been examined by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR). Y1 - 2015 U6 - https://doi.org/10.1016/j.electacta.2015.06.126 SN - 0013-4686 VL - 183 SP - 130 EP - 136 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Nakagawa, Masaki A1 - Michaux, Frank A1 - Kallweit, Stephan A1 - Maeda, Kazuhiro T1 - Unsteady flow measurements in the wake behind a wind-tunnel car model by using high-speed planar PIV T2 - 11TH International Symposium on Particle Image Velocimetry – PIV15 Santa Barbara, California, September 14-16, 2015 N2 - This study investigates unsteady characteristics of the wake behind a 28%-scale car model in a wind tunnel using highspeed planar particle image velocimetry (PIV). The car model is based on a hatchback passenger car that is known to have relatively high fluctuations in its aerodynamic loads. This study primarily focuses on the lateral motion of the flow on the horizontal plane to determine the effect of the flow motion on the straight-line stability and the initial steering response of the actual car on a track. This paper first compares the flow fields in the wake behind the above mentioned model obtained using conventional and high-speed planar PIV, with sampling frequencies of 8 Hz and 1 kHz, respectively. Large asymmetrically coherent flow structures, which fluctuate at frequencies below 2 Hz, are observed in the results of highspeed PIV measurements, whereas conventional PIV is unable to capture these features of the flow owing to aliasing. This flow pattern with a laterally swaying motion is represented by opposite signs of cross-correlation coefficients of streamwise velocity fluctuations for the two sides of the car model. Effects of two aerodynamic devices that are known to reduce the fluctuation levels of the aerodynamic loads are then extensively investigated. The correlation analyses reveal that these devices indeed reduce the fluctuation levels of the flow and the correlation values around the rear combination-lamp, but it is found that the effects of these devices are different around the c-pillar. Y1 - 2015 ER - TY - JOUR A1 - Kuperjans, Isabel A1 - Weitzel, J. T1 - Energiedesign 2020 : Sichere Strom- und Wärmeversorgung für die Industrie JF - TAB: das Fachmedium der TGA-Branche Y1 - 2015 SN - 0341-2032 IS - 3 SP - 105 EP - 107 PB - Bauverlag CY - Gütersloh ER - TY - JOUR A1 - Hoeveler, Bastian A1 - Janser, Frank A1 - Bindewald, Thorsten A1 - Gebhardt, Andreas T1 - Entwurf, Fertigung und Untersuchung eines Windkanalmodells eines innovativen, senkrechtstartenden Kleinflugzeuges JF - RTejournal - Forum für Rapid Technologie Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0009-2-42921 SN - 1614-0923 IS - 12 SP - 1 EP - 5 PB - Fachhochschule Aachen CY - Aachen ER - TY - JOUR A1 - Wollert, Jörg T1 - IO-Link – für smarte Sensoren JF - elektroniknet.de Y1 - 2015 ER - TY - JOUR A1 - Wollert, Jörg T1 - Echtzeit-Ethernet : Protokoll-Reigen JF - elektroniknet.de Y1 - 2015 ER - TY - CHAP A1 - Breuer, Lars A1 - Raue, Markus A1 - Mang, Thomas A1 - Schöning, Michael Josef A1 - Thoelen, Ronald A1 - Wagner, Torsten T1 - Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications T2 - 12. Dresdner Sensor-Symposium 2015 Y1 - 2015 U6 - https://doi.org/10.5162/12dss2015/P5.8 SP - 206 EP - 209 ER - TY - CHAP A1 - Oberländer, Jan A1 - Jildeh, Zaid B. A1 - Kirchner, Patrick A1 - Wendeler, Luisa A1 - Bromm, Alexander A1 - Iken, Heiko A1 - Wagner, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Experimental and numerical evaluation of interdigitated electrode array for monitoring gaseous sterilization processes T2 - 12. Dresdner Sensor-Symposium 2015 Y1 - 2015 U6 - https://doi.org/10.5162/12dss2015/P3.11 SP - 163 EP - 168 ER - TY - JOUR A1 - Miyamato, Ko-ichiro A1 - Sakakita, Sakura A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Application of chemical imaging sensor to in-situ pH imaging in the vicinity of a corroding metal surface JF - Electrochimica Acta N2 - The chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion. Y1 - 2015 U6 - https://doi.org/10.1016/j.electacta.2015.07.184 SN - 0013-4686 VL - 183 SP - 137 EP - 142 PB - Elsevier CY - Amsterdam ER -