TY - CHAP A1 - Ahmed, H. A1 - Schlenkhoff, A. A1 - Bung, Daniel Bernhard T1 - Hydrodynamic characteristics of vertical slotted wall breakwaters T2 - Balance and uncertainty - water in a changing world : proceedings of the 34th IAHR world congress ; 33rd Hydrology and Water Resources Symposium ; 10th Conference on Hydraulics in Water Engineering ; 26 June - 1 July 2011, Brisbane, Australia Y1 - 2011 SN - 978-0-85825-868-6 SP - 1179 EP - 1186 ER - TY - JOUR A1 - Ahmed, Essam A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Mokrov, Oleg T1 - On formability of tailor laser welded blanks of DP/TRIP steel sheets JF - Science and technology of welding and joining N2 - This paper aims to evaluate the formability of tailor welded blanks of dual phase (DP600)/transformation induced plasticity (TRIP700) steel sheets. In this work, bead on plate butt joints of 2·5 mm DP600 and 1·2 mm TRIP700 steel sheets were performed using CO2 laser beam welding. Microhardness measurements and transverse tensile testing were carried out to characterise the welds. The formability of base metals and welds were investigated by standard Erichsen test. In a perpendicular tensile test to the weld line, all specimens were fractured at the TRIP base metal, and the strengths were somewhat higher than those of base metal. There was a significant reduction in formability caused by welding of the DP600/TRIP700 steel sheets, and the formability increased with increasing welding speed. Y1 - 2010 U6 - https://doi.org/10.1179/136217110X12731414739754 SN - 1743-2936 VL - 15 IS - 5 SP - 337 EP - 342 PB - Maney CY - Leeds ER - TY - CHAP A1 - Ahlbrink, Nils A1 - Alexopoulos, Spiros A1 - Andersson, Joel A. E. A1 - Belhomme, B. A1 - Teixeira Boura, Cristiano José A1 - Gall, Jan A1 - Hirsch, Tobias T1 - viCERP - the Virtual Institute of Central Receiver Power Plant T2 - MATHMOD 2009 - 6th Vienna International Conference on Mathematical Modelling : February 11 - 13, 2009, Vienna, Austria. ARGESIM Report. No. 35 Y1 - 2009 SN - 978-3-901608-35-3 PB - Elsevier CY - Amsterdam ER - TY - PAT A1 - Ahlborn, Kristina A1 - Gerlach, Frank A1 - Iken, Heiko A1 - Schöning, Michael Josef A1 - Vonau, Winfried T1 - Miniaturisierte, potentiometrische Indikatorelektrode und Verfahren zu deren Herstellung : Offenlegungsschrift Y1 - 2012 ER - TY - JOUR A1 - Agrafiotis, Christos C. A1 - Mavroidis, Ilias A1 - Konstandopoulos, Athansios G. A1 - Hoffschmidt, Bernhard A1 - Stobbe, Per A1 - Romero, Manuel A1 - Fernandez-Quero, Valerio T1 - Evaluation of porous silicon carbide monolithic honeycombs as volumetric receivers/collectors of concentrated solar radiation JF - Solar energy materials and solar cells Y1 - 2007 SN - 1879-3398 (E-Journal); 0927-0248 (Print) VL - Vol. 91 IS - Iss. 6 SP - 474 EP - 488 ER - TY - JOUR A1 - Aggeloussis, Nickos A1 - Giannakou, Erasmia A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo JF - Gait and Posture N2 - The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38–63 mm; pennation angle: RMS = ∼1.5°, range: 22–32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait. Y1 - 2010 U6 - https://doi.org/10.1016/j.gaitpost.2009.08.249 SN - 0966-6362 VL - 31 IS - 1 SP - 73 EP - 77 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Aggarwal, Prerna A1 - Singh, Virendra A1 - Singh, Arjun A1 - Scherer, Ulrich W. A1 - Singh, Tejvir A1 - Singla, Madan L. A1 - Srivastava, Alok T1 - Physico-chemical transformations in swift heavy ion modified poly(ethyleneterephthalate) JF - Radiation Physics and Chemistry Y1 - 2011 SN - 0969-806X N1 - In Press, Accepted Manuscript SP - 1 EP - 28 PB - Pergamon Press CY - Oxford ER - TY - JOUR A1 - Aggarwal, Pranav A1 - Dhiman, Shashi K. A1 - Kumar, G. A1 - Scherer, Ulrich W. A1 - Singla, M. L. A1 - Srivastava, Alok T1 - Optical study of poly(ethyleneterephthalate) modified by different ionizing radiation dose JF - Indian Journal of Pure and Applied Physics N2 - Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions. Y1 - 2012 SN - 0019-5596 VL - 50 IS - 2 SP - 129 EP - 132 ER - TY - CHAP A1 - Adomeit, G. A1 - Willms, Herbert ED - Skupinski, Edwin T1 - Experimental investigation of the acceleration of deflagration in wake flow T2 - Safety of thermal water reactors : proceedings of a Seminar on the Results of the European Communities’ Indirect Action Research Programme on Safety of Thermal Water Reactors, held in Brussels, 1–3 October 1984 / Commission of the European Communities Y1 - 1984 SN - 0-86010-678-0 SN - 978-94-009-4972-0 (Online-Nachdr. vom Springer-Verl.) N1 - Forschungsvorhaben Nr. 024 SRD SP - 294 EP - 304 PB - Graham & Trotman [u.a.] CY - London Gaithersburg, Md. ER - TY - RPRT A1 - Adomeit, G. A1 - Willms, Herbert T1 - Experimental investigation of the acceleration of deflagration in wake flow : final report. - (Euratom-publications-EUR ; 9593 : Nuclear science and technology) Y1 - 1984 SN - 92-825-4699-3 PB - Commission of the European Communities CY - Luxembourg ER - TY - RPRT A1 - Adler, J. A1 - Heymer, H. A1 - Richter, H. J. A1 - Fend, Th. A1 - Smirnova, O. A1 - Rietbrock, P. A1 - Petchenko, A. A1 - Issendorff, F. v. A1 - Steven, M. A1 - Trimis, D. A1 - Gonsior, Daniel A1 - Helsper, Christoph A1 - Hoffschmidt, Bernhard T1 - INNOTRAP - innovative Rußfilter für LKW-Dieselmotoren : Abschlussbericht Förderkennzeichen 16IN0313 Y1 - 2009 ER - TY - CHAP A1 - Adenacker, J. A1 - Gerhards, Benjamin A1 - Otten, Christian A1 - Schleser, Markus T1 - Laserstrahlschweißen von Aluminium-Kupfer-Werkstoffkombinationen für die Elektromobilität T2 - DVS CONGRESS 2021 Y1 - 2021 SN - 978-3-96144-146-4 N1 - DVS CONGRESS 2021, 14. – 17. September 2021, Essen. Große Schweißtechnische Tagung 2021, DVS CAMPUS 2021. DVS Berichte, Band: 371 SP - 31 EP - 38 PB - DVS Media GmbH CY - Düsseldorf ER - TY - CHAP A1 - Adams, Moritz A1 - Losekamm, Martin J. A1 - Czupalla, Markus T1 - Development of the Thermal Control System for the RadMap Telescope Experiment on the International Space Station T2 - International Conference on Environmental Systems Y1 - 2020 N1 - 2020 International Conference on Environmental Systems, 12. Juli 2020 – 16. Juli 2020, Lissabon SP - 1 EP - 10 ER - TY - THES A1 - Ackermann, Vincent T1 - Filos : Design eines Front-Ends für das robotergeführte Laser-Osteotom-System STELLA. N2 - In der Abschlussarbeit „FILOS“ wurde in Zusammenarbeit mit dem Fraunhofer-Institut für Lasertechnik (ILT) ein Front-End für das laserbasierte Osteotom STELLA entwickelt. STELLA soll Kraniotomie (das Eröffnen des Schädels) im wachen Zustand ermöglichen und erfordert eine benutzerfreundliche Bedienungsplattform sowie ein funktionales und ästhetisches Design. Das Ziel von „FILOS“ war es, ein Gehäuse zu entwerfen, das den medizinischen Anforderungen entspricht, und ein Bedienkonzept zu entwickeln, dass die Akzeptanz bei Patient:innen und Anwender:innen fördert. Durch Expert:innen-Interviews mit Neurochirurg:innen und enge Zusammenarbeit mit dem ILT wurde ein durchdachtes Design entwickelt. Dieses soll den Anforderungen der Anwender:innen gerecht werden, das zukünftige Operationssystem repräsentieren und somit einen Mehrwert in der Medizin schaffen. KW - Wachoperation KW - Laserchirurgie KW - Medizintechnik KW - Cobot KW - Industrial Design Y1 - 2024 N1 - Für diese Arbeit steht kein Volltext zur Verfügung. PB - FH Aachen CY - Aachen ER - TY - BOOK A1 - Ackermann, Hans-Josef A1 - Mehl, Max A1 - Peischl, Markus T1 - Modulares Graphik-Subsystem für die Echtzeitdarstellung von 3D-Anwendungen : Abschlußbericht ; Contract NT 2815-A-8 / Hans-Josef Ackermann; Max Mehl; Markus Peischl. Fachbereich Informatik, Technische Hochschule Darmstadt; Bundesministerium für Forschung und Technologie, Bonn Y1 - 1990 N1 - Forschungs- und Arbeitsberichte des Fachgebietes Graphisch-Interaktive Systeme, Technische Hochschule Darmstadt ; 90-4 PB - Techn. Hochschule CY - Darmstadt ER - TY - JOUR A1 - Ackermann, Hans-Josef A1 - Jäger, Michael A1 - Osterfeld, Utz A1 - Hornung, Christoph T1 - Building a Multimedia ISDN PC / Jäger, Michael ; Osterfeld, Utz ; Ackermann, Hans-Josef ; Hornung, Christoph JF - Institute of Electrical and Electronics Engineers: IEEE computer graphics and applications. 13 (1993), H. 5 Y1 - 1993 SN - 0272-1716 SP - 24 EP - 33 ER - TY - JOUR A1 - Ackermann, Hans-Josef T1 - Single chip hardware support for rasterization and texture mapping JF - Computers & graphics : CAG ; an international journal of applications in computer graphics. 20 (1996), H. 4 Y1 - 1996 SN - 0097-8493 SP - 503 EP - 514 ER - TY - BOOK A1 - Ackermann, Hans-Josef T1 - Hardware-Unterstützung für effiziente Dreiecksrasterisierung und texture mapping Y1 - 1996 SN - 3826512081 N1 - zugl.: Techn. Hochsch., Diss.--Darmstadt, 1995. PB - Shaker CY - Aachen ER - TY - JOUR A1 - Ackermann, Hans-Josef T1 - Morphing- und Level-of-Detail-Techniken zur Reduzierung des Darstellungsaufwands bei Echtzeit-Sichtsimulationen JF - Digital controls for high resolution display : JESSI Europrojekt No. 3203000, AE-36 ; Abschlußbericht ; Laufzeit u. Berichtszeitraum: 01.01.1995 bis 31.12.1996. Y1 - 1997 CY - Erlangen ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Tödter, Julia A1 - Niehues, Julia A1 - Telöken, Matthias A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - 3D printed modular immunofiltration columns for frequency mixing-based multiplex magnetic immunodetection JF - Sensors N2 - For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated. Y1 - 2019 U6 - https://doi.org/10.3390/s19010148 SN - 1424-8220 VL - 19 IS - 1 PB - MDPI CY - Basel ER -