TY - BOOK A1 - Pieper, Martin T1 - Quantum mechanics: Introduction to mathematical formulation N2 - Anyone who has always wanted to understand the hieroglyphs on Sheldon's blackboard in the TV series The Big Bang Theory or who wanted to know exactly what the fate of Schrödinger's cat is all about will find a short, descriptive introduction to the world of quantum mechanics in this essential. The text particularly focuses on the mathematical description in the Hilbert space. The content goes beyond popular scientific presentations, but is nevertheless suitable for readers without special prior knowledge thanks to the clear examples. KW - Quantenmechanik KW - Hilbert Room KW - Postulates KW - Schrödingers cat KW - Operators Y1 - 2021 SN - 978-3-658-32644-9 SN - 978-3-658-32645-6 U6 - https://doi.org/10.1007/978-3-658-32645-6 PB - Springer CY - Wiesbaden ER - TY - CHAP A1 - Jordan, Frank A1 - Katz, Christiane A1 - Pieper, Martin T1 - Online-Kollaboration in der Mathematik: Ein Design-Based-Research-Projekt T2 - Forschungsimpulse für hybrides Lehren und Lernen an Hochschulen N2 - Die Studie erörtert anhand eines Fallbeispiels aus der Mathematik für Ingenieur*innen, wie didaktische Gestaltungsprinzipien für Soziale Präsenz, Kollaboration und das Lösen von praxisnahen Problemen mit mathematischem Denken in einer Online-Umgebung aussehen können. Hierfür zieht der Beitrag den forschungsmethodologischen Rahmen Design-Based Research (DBR) hinzu und berichtet über Zwischenergebnisse. DBR wird an dieser Stelle als eine systematische Herangehensweise an kurzfristige Lehrveränderungen und als Chance auf dem Weg zu einer neuen Hochschullehre nach der COVID-19-Pandemie dargestellt, die theoretische und empirische Erkenntnisse mit Praxisverknüpfung und -relevanz vereint. Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:832-cos4-9465 SP - 245 EP - 261 PB - TH Köln CY - Köln ER - TY - JOUR A1 - Heel, Mareike van A1 - Dikta, Gerhard A1 - Braekers, Roel T1 - Bootstrap based goodness‑of‑fit tests for binary multivariate regression models JF - Journal of the Korean Statistical Society N2 - We consider a binary multivariate regression model where the conditional expectation of a binary variable given a higher-dimensional input variable belongs to a parametric family. Based on this, we introduce a model-based bootstrap (MBB) for higher-dimensional input variables. This test can be used to check whether a sequence of independent and identically distributed observations belongs to such a parametric family. The approach is based on the empirical residual process introduced by Stute (Ann Statist 25:613–641, 1997). In contrast to Stute and Zhu’s approach (2002) Stute & Zhu (Scandinavian J Statist 29:535–545, 2002), a transformation is not required. Thus, any problems associated with non-parametric regression estimation are avoided. As a result, the MBB method is much easier for users to implement. To illustrate the power of the MBB based tests, a small simulation study is performed. Compared to the approach of Stute & Zhu (Scandinavian J Statist 29:535–545, 2002), the simulations indicate a slightly improved power of the MBB based method. Finally, both methods are applied to a real data set. Y1 - 2021 U6 - https://doi.org/10.1007/s42952-021-00142-4 SN - 2005-2863 (Online) SN - 1226-3192 (Print) N1 - Corresponding author: Mareike van Heel VL - 51 PB - Springer Nature CY - Singapur ER - TY - JOUR A1 - Georg, Jörg Heiner A1 - Stollenwerk, Dominik A1 - Reinkensmeier, Sebastian A1 - Jungbluth, Christian T1 - „Smartes“ Laden an öffentlich zugänglichen Ladesäulen – Teil 1: Quo vadis, Marktdesign? JF - Energiewirtschaftliche Tagesfragen : et ; Zeitschrift für Energiewirtschaft, Recht, Technik und Umwelt Y1 - 2021 SN - 0720-6240 SN - 0013-743X VL - 71 IS - 1/2 SP - 64 EP - 69 PB - ETV Energieverlag CY - Essen ER - TY - JOUR A1 - Stollenwerk, Dominik A1 - Reinkensmeier, Sebastian A1 - Georg, Jörg Heiner A1 - Jungbluth, Christian T1 - „Smartes“ Laden an öffentlich zugänglichen Ladesäulen – Teil 2: USER-Verhalten und -Erwartungen JF - Energiewirtschaftliche Tagesfragen : et ; Zeitschrift für Energiewirtschaft, Recht, Technik und Umwelt Y1 - 2021 SN - 0720-6240 SN - 0013-743X VL - 71 IS - 3 SP - 38 EP - 42 PB - ETV Energieverlag CY - Essen ER - TY - CHAP A1 - El Moussaoui, Noureddine A1 - Kassmi, Khalil A1 - Alexopoulos, Spiros A1 - Schwarzer, Klemens A1 - Chayeb, Hamid A1 - Bachiri, Najib T1 - Simulation studies on a new innovative design of a hybrid solar distiller MSDH alimented with a thermal and photovoltaic energy T2 - Materialstoday: Proceedings N2 - In this paper, we present the structure, the simulation the operation of a multi-stage, hybrid solar desalination system (MSDH), powered by thermal and photovoltaic (PV) (MSDH) energy. The MSDH system consists of a lower basin, eight horizontal stages, a field of four flat thermal collectors with a total area of 8.4 m2, 3 Kw PV panels and solar batteries. During the day the system is heated by thermal energy, and at night by heating resistors, powered by solar batteries. These batteries are charged by the photovoltaic panels during the day. More specifically, during the day and at night, we analyse the temperature of the stages and the production of distilled water according to the solar irradiation intensity and the electric heating power, supplied by the solar batteries. The simulations were carried out in the meteorological conditions of the winter month (February 2020), presenting intensities of irradiance and ambient temperature reaching 824 W/m2 and 23 °C respectively. The results obtained show that during the day the system is heated by the thermal collectors, the temperature of the stages and the quantity of water produced reach 80 °C and 30 Kg respectively. At night, from 6p.m. the system is heated by the electric energy stored in the batteries, the temperature of the stages and the quantity of water produced reach respectively 90 °C and 104 Kg for an electric heating power of 2 Kw. Moreover, when the electric power varies from 1 Kw to 3 Kw the quantity of water produced varies from 92 Kg to 134 Kg. The analysis of these results and their comparison with conventional solar thermal desalination systems shows a clear improvement both in the heating of the stages, by 10%, and in the quantity of water produced by a factor of 3. Y1 - 2021 U6 - https://doi.org/10.1016/j.matpr.2021.03.115 SN - 2214-7853 N1 - The Fourth edition of the International Conference on Materials & Environmental Science (ICMES 2020), virtual conference, November 18-28, 2020, Morocco VL - 45 IS - 8 SP - 7653 EP - 7660 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Butenweg, Christoph A1 - Gellert, Christoph A1 - Meyer, Udo T1 - Erdbebenbemessung bei Mauerwerksbauten T2 - Mauerwerk Kalender 2021: Kunststoffverankerungen Digitalisierung im Mauerwerksbau N2 - Der vorliegende Beitrag stellt den seismischen Nachweis von Mauerwerksbauten in Deutschland auf Grundlage der DIN EN 1998‐1/NA vor, wobei auch die wesentlichen Änderungen zu der Norm DIN 4149 vergleichend erläutert werden. Vorgestellt werden die Definition der Erdbebeneinwirkung, das seismische Verhalten von Mauerwerksbauten und die Erläuterung der Rechenverfahren. Darauf aufbauend wird die Anwendung an drei Praxisbeispielen demonstriert. Y1 - 2021 SN - 9783433032930 SN - 9783433610732 U6 - https://doi.org/10.1002/9783433610732.ch12 SP - 329 EP - 355 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Butenweg, Christoph A1 - Kubalski, Thomas A1 - El-Deib, Khaled A1 - Gellert, Christoph ED - Jesse, Dirk T1 - Erdbebennachweis von Mauerwerksbauten nach DIN EN 1998-1/NA-2021 JF - Bautechnik : Zeitschrift für den gesamten Ingenieurbau N2 - Mauerwerksbauten in Deutschland sind mit Einführung des nationalen Anwendungsdokuments DIN EN 1998-1/NA auf Grundlage einer neuen probabilistischen Erdbebenkarte nachzuweisen. Für erfolgreiche Erdbebennachweise üblicher Grundrissformen von Mauerwerksbauten stehen in dem zukünftigen Anwendungsdokument neue rechnerische Nachweismöglichkeiten zur Verfügung, mit denen die Tragfähigkeitsreserven von Mauerwerksbauten in der Baupraxis mit einem überschaubaren Aufwand besser in Ansatz gebracht werden können. Das Standardrechenverfahren ist weiterhin der kraftbasierte Nachweis, der nun mit höheren Verhaltensbeiwerten im Vergleich zur DIN 4149 durchgeführt werden kann. Die höheren Verhaltensbeiwerte basieren auf der besseren Ausnutzung der gebäudespezifischen Verformungsfähigkeit und Energiedissipation sowie der Lastumverteilung der Schubkräfte im Grundriss mit Ansatz von Rahmentragwirkung durch Wand-Deckeninteraktionen. Alternativ dazu kann ein nichtlinearer Nachweis auf Grundlage von Pushover-Analysen zur Anwendung kommen. Vervollständigt werden die Regelungen für Mauerwerksbauten durch neue Regelungen für nichttragende Innenwände und Außenmauerschalen. Der vorliegende Beitrag stellt die Grundlagen und Hintergründe der neuen rechnerischen Nachweise in DIN EN 1998-1/NA vor und demonstriert deren Anwendung an einem Beispiel aus der Praxis. Y1 - 2021 U6 - https://doi.org/10.1002/bate.202100064 SN - 1437-0999 SN - 0005-6820, 0932-8351 VL - 98 IS - 11 SP - 852 EP - 863 PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Butenweg, Christoph ED - Kuzmanović, Vladan ED - Ignjatović, Ivan T1 - Integrated approach for monitoring and management of buildings with digital building models and modern sensor technologies T2 - Proceedings of the International Conference Civil Engineering 2021 - Achievements and Visions N2 - Nowadays modern high-performance buildings and facilities are equipped with monitoring systems and sensors to control building characteristics like energy consumption, temperature pattern and structural safety. The visualization and interpretation of sensor data is typically based on simple spreadsheets and non-standardized user-oriented solutions, which makes it difficult for building owners, facility managers and decision-makers to evaluate and understand the data. The solution of this problem in the future are integrated BIM-Sensor approaches which allow the generation of BIM models incorporating all relevant information of monitoring systems. These approaches support both the dynamic visualization of key structural performance parameters, the effective long-term management of sensor data based on BIM and provide a user-friendly interface to communicate with various stakeholders. A major benefit for the end user is the use of the BIM software architecture, which is the future standard anyway. In the following, the application of the integrated BIM-Sensor approach is illustrated for a typical industrial facility as a part of an early warning and rapid response system for earthquake events currently developed in the research project “ROBUST” with financial support by the German Federal Ministry for Economic Affairs and Energy (BMWI). Y1 - 2021 N1 - Civil Engineering 2021 – Achievements and Visions, University of Belgrade, October 25 – 26, 2021 Belgrade, Serbia SP - 67 EP - 75 PB - University of Belgrade CY - Belgrade ER - TY - JOUR A1 - El-Deib, Khaled A1 - Butenweg, Christoph A1 - Klinkel, Sven ED - Jesse, Dirk T1 - Erdbebennachweis von Mauerwerksbauten mit realistischen Modellen und erhöhten Verhaltensbeiwerten JF - Mauerwerk N2 - Die Anwendung des linearen Nachweiskonzepts auf Mauerwerksbauten führt dazu, dass bereits heute Standsicherheitsnachweise für Gebäude mit üblichen Grundrissen in Gebieten mit moderaten Erdbebeneinwirkungen nicht mehr geführt werden können. Diese Problematik wird sich in Deutschland mit der Einführung kontinuierlicher probabilistischer Erdbebenkarten weiter verschärfen. Aufgrund der Erhöhung der seismischen Einwirkungen, die sich vielerorts ergibt, ist es erforderlich, die vorhandenen, bislang nicht berücksichtigten Tragfähigkeitsreserven in nachvollziehbaren Nachweiskonzepten in der Baupraxis verfügbar zu machen. Der vorliegende Beitrag stellt ein Konzept für die gebäudespezifische Ermittlung von erhöhten Verhaltensbeiwerten vor. Die Verhaltensbeiwerte setzen sich aus drei Anteilen zusammen, mit denen die Lastumverteilung im Grundriss, die Verformungsfähigkeit und Energiedissipation sowie die Überfestigkeiten berücksichtigt werden. Für die rechnerische Ermittlung dieser drei Anteile wird ein nichtlineares Nachweiskonzept auf Grundlage von Pushover-Analysen vorgeschlagen, in denen die Interaktionen von Wänden und Geschossdecken durch einen Einspanngrad beschrieben werden. Für die Bestimmung der Einspanngrade wird ein nichtlinearer Modellierungsansatz eingeführt, mit dem die Interaktion von Wänden und Decken abgebildet werden kann. Die Anwendung des Konzepts mit erhöhten gebäudespezifischen Verhaltensbeiwerten wird am Beispiel eines Mehrfamilienhauses aus Kalksandsteinen demonstriert. Die Ergebnisse der linearen Nachweise mit erhöhten Verhaltensbeiwerten für dieses Gebäude liegen deutlich näher an den Ergebnissen nichtlinearer Nachweise und somit bleiben übliche Grundrisse in Erdbebengebieten mit den traditionellen linearen Rechenansätzen nachweisbar. N2 - Seismic verification of masonry buildings based on realistic calculation models and increased behavior factorsWith the application of the traditional linear verification con­cept to masonry structures it is already no longer possible to carry out structural safety verifications even for buildings with standard ground plan configurations in areas with moderate seismicity. This problem will be exacerbated in Germany with the introduction of continuous probabilistic earthquake maps. Due to the increased seismic actions, it is necessary to make the existing load­bearing capacity reserves that have not yet been taken into account available in comprehensible verifica­tion concepts in construction practice. This article presents a concept for the building­specific determination of increased behavior factors. The behavior factors are composed of three components, which take into account the load redistribution in ground plans, the deformation capability and energy dissipation and all kinds of overstrength effects. For the calculation of these three components, a non­linear verification concept based on pushover analyses is applied, in which the interac­tions of walls and floor slabs are described by a level of re­straint. A non­linear modeling approach of the overall building is introduced for the determination of the restraint levels, with which the interaction of walls and floor slabs can be simulated. The results of the linear verifications with increased behavior factors for this building are significantly closer to the results of non­linear verifications and thus the standard ground plan con­figurations in areas with moderate seismicity can still be veri­fied with the traditional linear calculation approaches. KW - Mauerwerksbauten KW - Erdbebeneinwirkung KW - Bemessung KW - Verhaltensbeiwerte KW - Pushover­Analysen Y1 - 2021 U6 - https://doi.org/10.1002/dama.202110014 SN - 1437-1022 SN - 1432-3427 VL - 2021 IS - 3 SP - 110 EP - 119 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Alexopoulos, Spiros A1 - Rau, Christoph A1 - Sattler, Johannes Christoph A1 - Anthrakidis, Anette A1 - Teixeira Boura, Cristiano José A1 - O’Connor, B. A1 - Chico Caminos, Ricardo Alexander A1 - Rendón, C. A1 - Hilger, P. T1 - Concentrating Solar Power T2 - Earth systems and environmental sciences N2 - The focus of this chapter is the production of power and the use of the heat produced from concentrated solar thermal power (CSP) systems. The chapter starts with the general theoretical principles of concentrating systems including the description of the concentration ratio, the energy and mass balance. The power conversion systems is the main part where solar-only operation and the increase in operational hours. Solar-only operation include the use of steam turbines, gas turbines, organic Rankine cycles and solar dishes. The operational hours can be increased with hybridization and with storage. Another important topic is the cogeneration where solar cooling, desalination and of heat usage is described. Many examples of commercial CSP power plants as well as research facilities from the past as well as current installed and in operation are described in detail. The chapter closes with economic and environmental aspects and with the future potential of the development of CSP around the world. KW - Central receiver power plant KW - Concentrated systems KW - Concentrating solar power KW - Fresnel power plant KW - Gas turbine Y1 - 2021 SN - 978-0-12-409548-9 U6 - https://doi.org/10.1016/B978-0-12-819727-1.00089-3 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Marinkovic, Marko A1 - Butenweg, Christoph T1 - Numerical analysis of the in-plane behaviour of decoupled masonry infilled RC frames JF - Engineering Structures N2 - Damage of reinforced concrete (RC) frames with masonry infill walls has been observed after many earthquakes. Brittle behaviour of the masonry infills in combination with the ductile behaviour of the RC frames makes infill walls prone to damage during earthquakes. Interstory deformations lead to an interaction between the infill and the RC frame, which affects the structural response. The result of this interaction is significant damage to the infill wall and sometimes to the surrounding structural system too. In most design codes, infill walls are considered as non-structural elements and neglected in the design process, because taking into account the infills and considering the interaction between frame and infill in software packages can be complicated and impractical. A good way to avoid negative aspects arising from this behavior is to ensure no or low-interaction of the frame and infill wall, for instance by decoupling the infill from the frame. This paper presents the numerical study performed to investigate new connection system called INODIS (Innovative Decoupled Infill System) for decoupling infill walls from surrounding frame with the aim to postpone infill activation to high interstory drifts thus reducing infill/frame interaction and minimizing damage to both infills and frames. The experimental results are first used for calibration and validation of the numerical model, which is then employed for investigating the influence of the material parameters as well as infill’s and frame’s geometry on the in-plane behaviour of the infilled frames with the INODIS system. For all the investigated situations, simulation results show significant improvements in behaviour for decoupled infilled RC frames in comparison to the traditionally infilled frames. KW - Seismic loading KW - Earthquake KW - In-plane performance, isolation KW - Infill wall design KW - Numerical modelling Y1 - 2022 U6 - https://doi.org/10.1016/j.engstruct.2022.114959 SN - 0141-0296 VL - 272 IS - 1 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Mahdi, Zahra A1 - Dersch, Jürgen A1 - Schmitz, Pascal A1 - Dieckmann, Simon A1 - Chico Caminos, Ricardo Alexander A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf A1 - Schwager, Christian A1 - Schmitz, Mark A1 - Gielen, Hans A1 - Gedle, Yibekal A1 - Büscher, Rauno T1 - Technical assessment of Brayton cycle heat pumps for the integration in hybrid PV-CSP power plants T2 - SOLARPACES 2020 N2 - The hybridization of Concentrated Solar Power (CSP) and Photovoltaics (PV) systems is a promising approach to reduce costs of solar power plants, while increasing dispatchability and flexibility of power generation. High temperature heat pumps (HT HP) can be utilized to boost the salt temperature in the thermal energy storage (TES) of a Parabolic Trough Collector (PTC) system from 385 °C up to 565 °C. A PV field can supply the power for the HT HP, thus effectively storing the PV power as thermal energy. Besides cost-efficiently storing energy from the PV field, the power block efficiency of the overall system is improved due to the higher steam parameters. This paper presents a technical assessment of Brayton cycle heat pumps to be integrated in hybrid PV-CSP power plants. As a first step, a theoretical analysis was carried out to find the most suitable working fluid. The analysis included the fluids Air, Argon (Ar), Nitrogen (N2) and Carbon dioxide (CO2). N2 has been chosen as the optimal working fluid for the system. After the selection of the ideal working medium, different concepts for the arrangement of a HT HP in a PV-CSP hybrid power plant were developed and simulated in EBSILON®Professional. The concepts were evaluated technically by comparing the number of components required, pressure losses and coefficient of performance (COP). KW - Solar thermal technologies KW - Hybrid energy system KW - Concentrated solar power KW - Power plants KW - Energy storage Y1 - 2022 SN - 978-0-7354-4195-8 U6 - https://doi.org/10.1063/5.0086269 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - SOLARPACES 2020: 26th International Conference on Concentrating Solar Power and Chemical Energy Systems, 28 September–2 October 2020, Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Zahra, Mahdi A1 - Phani Srujan, Merige A1 - Chico Caminos, Ricardo Alexander A1 - Schmitz, Pascal A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José A1 - Schmitz, Mark A1 - Gielen, Hans A1 - Gedle, Yibekal A1 - Dersch, Jürgen T1 - Modeling the thermal behavior of solar salt in electrical resistance heaters for the application in PV-CSP hybrid power plants T2 - SOLARPACES 2020 N2 - Concentrated Solar Power (CSP) systems are able to store energy cost-effectively in their integrated thermal energy storage (TES). By intelligently combining Photovoltaics (PV) systems with CSP, a further cost reduction of solar power plants is expected, as well as an increase in dispatchability and flexibility of power generation. PV-powered Resistance Heaters (RH) can be deployed to raise the temperature of the molten salt hot storage from 385 °C up to 565 °C in a Parabolic Trough Collector (PTC) plant. To avoid freezing and decomposition of molten salt, the temperature distribution in the electrical resistance heater is investigated in the present study. For this purpose, a RH has been modeled and CFD simulations have been performed. The simulation results show that the hottest regions occur on the electric rod surface behind the last baffle. A technical optimization was performed by adjusting three parameters: Shell-baffle clearance, electric rod-baffle clearance and number of baffles. After the technical optimization was carried out, the temperature difference between the maximum temperature and the average outlet temperature of the salt is within the acceptable limits, thus critical salt decomposition has been avoided. Additionally, the CFD simulations results were analyzed and compared with results obtained with a one-dimensional model in Modelica. KW - Solar thermal technologies KW - Hybrid energy system KW - Concentrated solar power KW - Energy storage KW - Photovoltaics Y1 - 2022 SN - 978-0-7354-4195-8 U6 - https://doi.org/10.1063/5.0086268 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - SOLARPACES 2020: 26th International Conference on Concentrating Solar Power and Chemical Energy Systems, 28 September–2 October 2020, Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - JOUR A1 - Butenweg, Christoph A1 - Marinkovic, Marko A1 - Phlipp, Michel A1 - Lins, Robin A1 - Renaut, Philipp ED - Haghsheno, Shervin T1 - Isolierung und BIM-basiertes Bauwerksmonitoring des neuen Gebäudekomplexes für das BioSense-Institut in Novi Sad, Serbien JF - Bauingenieur N2 - Im Norden von Serbien erfolgt in Novi Sad der Neubau eines modernen Forschungsgebäudes für das BioSense-Institut mit finanzieller Unterstützung durch die Eu-ropäische Union. Der Gebäudeteil mit Laboren wird zum Schutz und zur Sicherstellung des reibungslosen Betriebs der sensiblen und kapitalintensiven technischen Einbauten mit ei-ner Erdbebenisolierung mit integrierter Körperschallisolation versehen. Zusätzlich wird der entkoppelte Laborteil des For-schungsgebäudes mit einem BIM-basierten Bauwerksmonito-ring versehen, um Änderungen des Gebäudezustands jederzeit abfragen und beurteilen zu können. KW - BIM KW - Sensor KW - Monitoring KW - Bauwerksüberwachung KW - Basisisolierung Y1 - 2022 U6 - https://doi.org/10.37544/0005-6650-2022-06-28 SN - 1436-4867 SN - 0005-6650 N1 - D-A-CH-Teil VL - 97 IS - 6 SP - S3 EP - S5 PB - VDI Fachmedien CY - Düsseldorf ER - TY - JOUR A1 - Rossi, Leonardo A1 - Winands, Mark H. M. A1 - Butenweg, Christoph ED - Zhang, Jessica T1 - Monte Carlo Tree Search as an intelligent search tool in structural design problems JF - Engineering with Computers : An International Journal for Simulation-Based Engineering N2 - Monte Carlo Tree Search (MCTS) is a search technique that in the last decade emerged as a major breakthrough for Artificial Intelligence applications regarding board- and video-games. In 2016, AlphaGo, an MCTS-based software agent, outperformed the human world champion of the board game Go. This game was for long considered almost infeasible for machines, due to its immense search space and the need for a long-term strategy. Since this historical success, MCTS is considered as an effective new approach for many other scientific and technical problems. Interestingly, civil structural engineering, as a discipline, offers many tasks whose solution may benefit from intelligent search and in particular from adopting MCTS as a search tool. In this work, we show how MCTS can be adapted to search for suitable solutions of a structural engineering design problem. The problem consists of choosing the load-bearing elements in a reference reinforced concrete structure, so to achieve a set of specific dynamic characteristics. In the paper, we report the results obtained by applying both a plain and a hybrid version of single-agent MCTS. The hybrid approach consists of an integration of both MCTS and classic Genetic Algorithm (GA), the latter also serving as a term of comparison for the results. The study’s outcomes may open new perspectives for the adoption of MCTS as a design tool for civil engineers. KW - Monte Carlo Tree Search KW - Structural design KW - Artificial intelligence KW - Civil engineering KW - Genetic algorithm Y1 - 2022 U6 - https://doi.org/10.1007/s00366-021-01338-2 SN - 1435-5663 SN - 0177-0667 VL - 38 IS - 4 SP - 3219 EP - 3236 PB - Springer Nature CY - Cham ER - TY - CHAP A1 - Milijaš, Aleksa A1 - Šakić, Bogdan A1 - Marinković, Marko A1 - Butenweg, Christoph A1 - Gams, Matija A1 - Klinkel, Sven ED - Arion, Cristian ED - Scupin, Alexandra ED - Ţigănescu, Alexandru T1 - Effects of prior in-plane damage on out-of-plane response of masonry infills with openings T2 - The Third European Conference on Earthquake Engineering and Seismology N2 - Masonry infill walls are the most traditional enclosure system that is still widely used in RC frame buildings all over the world, particularly in seismic active regions. Although infill walls are usually neglected in seismic design, during an earthquake event they are subjected to in-plane and out-of-plane forces that can act separately or simultaneously. Since observations of damage to buildings after recent earthquakes showed detrimental effects of in-plane and out-of-plane load interaction on infill walls, the number of studies that focus on influence of in-plane damage on out-of-plane response has significantly increased. However, most of the xperimental campaigns have considered only solid infills and there is a lack of combined in-plane and out-of-plane experimental tests on masonry infills with openings, although windows and doors strongly affect seismic performance. In this paper, two types of experimental tests on infills with window openings are presented. The first is a pure out-of-plane test and the second one is a sequential in-plane and out-of-plane test aimed at investigating the effects of existing in-plane damage on outof-plane response. Additionally, findings from two tests with similar load procedure that were carried out on fully infilled RC frames in the scope of the same project are used for comparison. Test results clearly show that window opening increased vulnerability of infills to combined seismic actions and that prevention of damage in infills with openings is of the utmost importance for seismic safety. KW - Seismic loading KW - In-plane load KW - Out-of-plane load KW - Interaction KW - Window opening Y1 - 2022 SN - 978-973-100-533-1 N1 - 3ECEES - Third European Conference on Earthquake Engineering and Seismology, September 4 – September 9, 2022, Bucharest SP - 2747 EP - 2756 ER - TY - CHAP A1 - Gedle, Yibekal A1 - Schmitz, Mark A1 - Gielen, Hans A1 - Schmitz, Pascal A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José A1 - Mahdi, Zahra A1 - Chico Caminos, Ricardo Alexander A1 - Dersch, Jürgen T1 - Analysis of an integrated CSP-PV hybrid power plant T2 - SOLARPACES 2020 N2 - In the past, CSP and PV have been seen as competing technologies. Despite massive reductions in the electricity generation costs of CSP plants, PV power generation is - at least during sunshine hours - significantly cheaper. If electricity is required not only during the daytime, but around the clock, CSP with its inherent thermal energy storage gets an advantage in terms of LEC. There are a few examples of projects in which CSP plants and PV plants have been co-located, meaning that they feed into the same grid connection point and ideally optimize their operation strategy to yield an overall benefit. In the past eight years, TSK Flagsol has developed a plant concept, which merges both solar technologies into one highly Integrated CSP-PV-Hybrid (ICPH) power plant. Here, unlike in simply co-located concepts, as analyzed e.g. in [1] – [4], excess PV power that would have to be dumped is used in electric molten salt heaters to increase the storage temperature, improving storage and conversion efficiency. The authors demonstrate the electricity cost sensitivity to subsystem sizing for various market scenarios, and compare the resulting optimized ICPH plants with co-located hybrid plants. Independent of the three feed-in tariffs that have been assumed, the ICPH plant shows an electricity cost advantage of almost 20% while maintaining a high degree of flexibility in power dispatch as it is characteristic for CSP power plants. As all components of such an innovative concept are well proven, the system is ready for commercial market implementation. A first project is already contracted and in early engineering execution. KW - Hybrid energy system KW - Power plants KW - Electricity generation KW - Energy storage KW - Associated liquids Y1 - 2022 SN - 978-0-7354-4195-8 U6 - https://doi.org/10.1063/5.0086236 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - SOLARPACES 2020: 26th International Conference on Concentrating Solar Power and Chemical Energy Systems, 28 September–2 October 2020, Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Niederwestberg, Stefan A1 - Schneider, Falko A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Introduction to a direct irradiated transparent tube particle receiver T2 - SOLARPACES 2020 N2 - New materials often lead to innovations and advantages in technical applications. This also applies to the particle receiver proposed in this work that deploys high-temperature and scratch resistant transparent ceramics. With this receiver design, particles are heated through direct-contact concentrated solar irradiance while flowing downwards through tubular transparent ceramics from top to bottom. In this paper, the developed particle receiver as well as advantages and disadvantages are described. Investigations on the particle heat-up characteristics from solar irradiance were carried out with DEM simulations which indicate that particle temperatures can reach up to 1200 K. Additionally, a simulation model was set up for investigating the dynamic behavior. A test receiver at laboratory scale has been designed and is currently being built. In upcoming tests, the receiver test rig will be used to validate the simulation results. The design and the measurement equipment is described in this work. KW - Solar irradiance KW - Ceramics Y1 - 2022 SN - 978-0-7354-4195-8 U6 - https://doi.org/10.1063/5.0086735 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - SOLARPACES 2020: 26th International Conference on Concentrating Solar Power and Chemical Energy Systems, 28 September–2 October 2020, Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Riga, Evi A1 - Pitilakis, Kyriazis A1 - Butenweg, Christoph A1 - Apostolaki, Stefania A1 - Karatzetzou, Anna ED - Arion, Cristian ED - Scupin, Alexandra ED - Ţigănescu, Alexandru T1 - Investigating the impact of the new European Seismic Hazard Model ESHM20 on the seismic design and safety control of industrial facilities T2 - The Third European Conference on Earthquake Engineering and Seismology N2 - The seismic performance and safety of major European industrial facilities has a global interest for Europe, its citizens and economy. A potential major disaster at an industrial site could affect several countries, probably far beyond the country where it is located. However, the seismic design and safety assessment of these facilities is practically based on national, often outdated seismic hazard assessment studies, due to many reasons, including the absence of a reliable, commonly developed seismic hazard model for whole Europe. This important gap is no more existing, as the 2020 European Seismic Hazard Model ESHM20 was released in December 2021. In this paper we investigate the expected impact of the adoption of ESHM20 on the seismic demand for industrial facilities, through the comparison of the ESHM20 probabilistic hazard at the sites where industrial facilities are located with the respective national and European regulations. The goal of this preliminary work in the framework of Working Group 13 of the European Association for Earthquake Engineering (EAEE), is to identify potential inadequacies in the design and safety control of existing industrial facilities and to highlight the expected impact of the adoption of the new European Seismic Hazard Model on the design of new industrial facilities and the safety assessment of existing ones. KW - ESHM20, industrial facilities KW - seismic hazard KW - seismic design KW - safety control Y1 - 2022 SN - 978-973-100-533-1 N1 - 3ECEES - Third European Conference on Earthquake Engineering and Seismology, September 4 – September 9, 2022, Bucharest SP - 3261 EP - 3270 ER -