TY - CHAP A1 - Strohmeier, Andreas ED - Vismann, Ulrich T1 - Siedlungswasserwirtschaft T2 - Wendehorst Bautechnische Zahlentafeln Y1 - 2012 SN - 978-3-8348-0960-5 U6 - https://doi.org/10.1007/978-3-8348-8613-2_19 N1 - Kapitel 19 SP - 1393 EP - 1498 PB - Vieweg + Teubner CY - Wiesbaden ET - 34 ER - TY - CHAP A1 - Biener, Ernst ED - Vismann, Ulrich T1 - Abfallwirtschaft T2 - Wendehorst Bautechnische Zahlentafeln Y1 - 2012 SN - 978-3-8348-0960-5 U6 - https://doi.org/10.1007/978-3-8348-8613-2_20 N1 - Kapitel 20 SP - 1499 EP - 1540 PB - Vieweg + Teubner CY - Wiesbaden ET - 34 ER - TY - CHAP A1 - Lohse, Wolfram A1 - Stroetmann, Richard ED - Vismann, Ulrich T1 - Stahlbau T2 - Wendehorst Bautechnische Zahlentafeln Y1 - 2012 SN - 978-3-8348-0960-5 U6 - https://doi.org/10.1007/978-3-8348-8613-2_13 N1 - Kapitel 13 SP - 777 EP - 1019 PB - Vieweg + Teubner CY - Wiesbaden ET - 34 ER - TY - JOUR A1 - Aggarwal, P. A1 - Dhiman, S. A1 - Kumar, G. A1 - Scherer, Ulrich W. A1 - Singla, M. L. A1 - Srivastava, A. T1 - Optical study of poly(ethyleneterephthalate) modified by different ionizing radiation dose JF - Indian Journal of Pure and Applied Physics N2 - Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions. Y1 - 2012 SN - 0019-5596 VL - 50 IS - 2 SP - 129 EP - 132 ER - TY - JOUR A1 - Staat, Manfred A1 - Trenz, Eva A1 - Lohmann, Philipp A1 - Frotscher, Ralf A1 - Klinge, Uwe A1 - Tabaza, Ruth A1 - Kirschner-Hermanns, Ruth T1 - New measurements to compare soft tissue anchoring systems in pelvic floor surgery JF - Journal of Biomedical Materials Research Part B: Applied Biomaterials N2 - Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment Y1 - 2012 U6 - https://doi.org/10.1002/jbm.b.32654 SN - 1552-4981 VL - 100B IS - 4 SP - 924 EP - 933 PB - Wiley CY - Hoboken, NJ ER - TY - BOOK A1 - Schmitz, Günter T1 - Elektronik im Kraftfahrzeug : Innovationen bei System und Komponenten ; mit 7 Tabellen / Hrsg.: Schmitz, Günter Y1 - 2012 SN - 978-3-8169-3110-2 N1 - Haus der Technik ; Bd. 123 PB - expert-Verl. CY - Renningen ER - TY - BOOK A1 - Vismann, Ulrich T1 - Wendehorst Bautechnische Zahlentafeln / hrsg. von Ulrich Vismann in Verbindung mit dem DIN Deutsches Institut für Normung e.V. Herwig Baumgartner ... Y1 - 2012 SN - 978-3-8348-0960-5 U6 - https://doi.org/10.1007/978-3-8348-8613-2 PB - Vieweg + Teubner CY - Wiesbaden ET - 34., vollst. überarb. und erw. Aufl. ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Kaneko, Kazumi A1 - Matsuo, Akira A1 - Wagner, Torsten A1 - Kanoh, Shiníchiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Miniaturized chemical imaging sensor system using an OLED display panel JF - Sensors and Actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated. KW - LAPS KW - Light-addressable potentiometric sensor KW - Chemical imaging sensor KW - Organic light-emitting diode display Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2011.02.029 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 82 EP - 87 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Leinhos, Marcel A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Characterization of biodegradable polymers with capacitive field-effect sensors JF - Sensors and actuators B: Chemical N2 - In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance–voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor. KW - Impedance spectroscopy KW - C–V method KW - Real-time monitoring KW - Poly(d,l-lacticacid) KW - (Bio)degradation KW - Field-effect sensor Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2012.07.099 SN - 0925-4005 N1 - Part of special issue "Selected Papers from the 14th International Meeting on Chemical Sensors" VL - 187 SP - 2 EP - 7 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Rysstad, Gunnar A1 - Schöning, Michael Josef A1 - Keusgen, Michael T1 - Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Sensors and Actuators B: Chemical N2 - A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes. KW - Sterilisation process KW - Hydrogen peroxide KW - Polyimide KW - Calorimetric gas sensor Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2011.01.032 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 60 EP - 66 PB - Elsevier CY - Amsterdam ER -