TY - CHAP A1 - Bäcker, Matthias A1 - Koch, C. A1 - Geiger, F. A1 - Eber, F. A1 - Gliemann, H. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - A New Class of Biosensors Based on Tobacco Mosaic Virus and Coat Proteins as Enzyme Nanocarrier T2 - Procedia Engineering Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.proeng.2016.11.228 SN - 1877-7058 N1 - Proceedings of the 30th anniversary Eurosensors Conference – Eurosensors 2016, 4-7. Sepember 2016, Budapest, Hungary VL - Vol. 168 SP - 618 EP - 621 ER - TY - CHAP A1 - Kasper, Katharina A1 - Schiffels, Johannes A1 - Krafft, Simone A1 - Kuperjans, Isabel A1 - Elbers, Gereon A1 - Selmer, Thorsten T1 - Biogas Production on Demand Regulated by Butyric Acid Addition T2 - IOP Conference Series: Earth and Environmental Science. Bd. 32 Y1 - 2016 U6 - http://dx.doi.org/10.1088/1755-1315/32/1/012009 SN - 1755-1315 N1 - ICARET 2016, International Conference on Advances in Renewable Energy and Technologies, Putrajaya, MY, Feb 23-25, 2016 VL - 32 SP - 012009/1 EP - 012009/4 ER - TY - JOUR A1 - Pinkenburg, Olaf A1 - Schiffels, Johannes A1 - Selmer, Thorsten T1 - Das CoLibry-Konzept – ein Werkzeugkasten für die Synthetische Biologie: Bioproduktion JF - BIOspektrum N2 - Regardless of size or destination, synthetic biology starts with com-parably small information units, which need to be combined and properly arranged in order to achieve a certain goal. This may be the de novo synthesis of individual genes from oligonucleotides, a shuffling of protein domains in order to create novel biocatalysts, the assembly of multiple enzyme encoding genes in metabolic pathway design, or strain development at the production stage. The CoLibry concept has been designed in order to close the gap between recombinant production of individual genes and genome editing. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s12268-016-0734-8 VL - 22 IS - 6 SP - 593 EP - 595 PB - Springer CY - Berlin ER - TY - JOUR A1 - Dantism, Shahriar A1 - Takenaga, Shoko A1 - Wagner, Patrick A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Determination of the extracellular acidification of Escherichia coli K12 with a multi-​chamber-​based LAPS system JF - Physica status solidi (a) N2 - On-line monitoring of the metabolic activity of microorganisms involved in intermediate stages of biogas production plays an important role to avoid undesirable “down times” during the biogas production. In order to control this process, an on-chip differential measuring system based on the light-addressable potentiometric sensor (LAPS) principle combined with a 3D-printed multi-chamber structure has been realized. As a test microorganism, Escherichia coli K12 (E. coli K12) were used for cell-based measurements. Multi-chamber structures were developed to determine the metabolic activity of E. coli K12 in suspension for a different number of cells, responding to the addition of a constant or variable amount of glucose concentrations, enabling differential and simultaneous measurements. Y1 - 2016 U6 - http://dx.doi.org/10.1002/pssa.201533043 SN - 1862-6300 VL - 213 IS - 6 SP - 1479 EP - 1485 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Doll, Theodor A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Engineering of functional interfaces / Theodor Doll ; Torsten Wagner ; Patrick Wagner ; Michael J. Schöning (eds.) JF - Physica status solidi (a) Y1 - 2016 U6 - http://dx.doi.org/10.1002/pssa.201670641 SN - 1862-6319 VL - 213 IS - 6 SP - 1393 EP - 1394 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Murib, M. S. A1 - Yeap, W. S. A1 - Eurlings, Y. A1 - Grinsven, B. van A1 - Boyen, H.-G. A1 - Conings, B. A1 - Michiels, L. A1 - Ameloot, M. A1 - Carleer, R. A1 - Warmer, J. A1 - Kaul, P. A1 - Haenen, K. A1 - Schöning, Michael Josef A1 - Ceuninck, W. de A1 - Wagner, P. T1 - Heat-transfer based characterization of DNA on synthetic sapphire chips JF - Sensors and Actuators B: Chemical N2 - In this study, we show that synthetic sapphire (Al₂O₃), an established implant material, can also serve as a platform material for biosensors comparable to nanocrystalline diamond. Sapphire chips, beads, and powder were first modified with (3-aminopropyl) triethoxysilane (APTES), followed by succinic anhydride (SA), and finally single-stranded probe DNA was EDC coupled to the functionalized layer. The presence of the APTES-SA layer on sapphire powders was confirmed by thermogravimetric analyis and Fourier-transform infrared spectroscopy. Using planar sapphire chips as substrates and X-ray photoelectron spectroscopy (XPS) as surface-sensitive tool, the sequence of individual layers was analyzed with respect to their chemical state, enabling the quantification of areal densities of the involved molecular units. Fluorescence microscopy was used to demonstrate the hybridization of fluorescently tagged target DNA to the probe DNA, including denaturation- and re-hybridization experiments. Due to its high thermal conductivity, synthetic sapphire is especially suitable as a chip material for the heat-transfer method, which was employed to distinguish complementary- and non-complementary DNA duplexes containing single-nucleotide polymorphisms. These results indicate that it is possible to detect mutations electronically with a chemically resilient and electrically insulating chip material. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.snb.2016.02.027 SN - 0925-4005 VL - 230 IS - 230 SP - 260 EP - 271 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Breuer, Lars A1 - Raue, Markus A1 - Strobel, M. A1 - Mang, Thomas A1 - Schöning, Michael Josef A1 - Thoelen, R. A1 - Wagner, Torsten T1 - Hydrogels with incorporated graphene oxide as light-addressable actuator materials for cell culture environments in lab-on-chip systems JF - Physica status solidi (a) N2 - Abstractauthoren Graphene oxide (GO) nanoparticles were incorporated in temperature-sensitive Poly(N-isopropylacrylamide) (PNIPAAm) hydrogels. The nanoparticles increase the light absorption and convert light energy into heat efficiently. Thus, the hydrogels with GO can be stimulated spatially resolved by illumination as it was demonstrated by IR thermography. The temporal progression of the temperature maximum was detected for different concentrations of GO within the polymer network. Furthermore, the compatibility of PNIPAAm hydrogels with GO and cell cultures was investigated. For this purpose, culture medium was incubated with hydrogels containing GO and the viability and morphology of chinese hamster ovary (CHO) cells was examined after several days of culturing in presence of this medium. Y1 - 2016 U6 - http://dx.doi.org/10.1002/pssa.201533056 SN - 1862-6300 VL - 213 IS - 6 SP - 1520 EP - 1525 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Hamad, E. M. A1 - Bilatto, S. E. R. A1 - Adly, N. Y. A1 - Correa, D. S. A1 - Wolfrum, B. A1 - Schöning, Michael Josef A1 - Offenhäusser, A. A1 - Yakushenko, A. T1 - Inkjet printing of UV-curable adhesive and dielectric inks for microfluidic devices JF - Lab on a Chip N2 - Bonding of polymer-based microfluidics to polymer substrates still poses a challenge for Lab-On-a-Chip applications. Especially, when sensing elements are incorporated, patterned deposition of adhesives with curing at ambient conditions is required. Here, we demonstrate a fabrication method for fully printed microfluidic systems with sensing elements using inkjet and stereolithographic 3D-printing. Y1 - 2016 U6 - http://dx.doi.org/10.1039/C5LC01195G SN - 1473-0189 VL - 16 IS - 1 SP - 70 EP - 74 PB - Royal Society of Chemistry CY - Cambridge ER - TY - CHAP A1 - Poghossian, Arshak A1 - Bronder, Thomas A1 - Scheja, S. A1 - Wu, Chunsheng A1 - Metzger-Boddien, C. A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Label-free Electrostatic Detection of DNA Amplification by PCR Using Capacitive Field-effect Devices T2 - Procedia Engineering N2 - A capacitive field-effect EIS (electrolyte-insulator-semiconductor) sensor modified with a positively charged weak polyelectrolyte of poly(allylamine hydrochloride) (PAH)/single-stranded probe DNA (ssDNA) bilayer has been used for a label-free electrostatic detection of pathogen-specific DNA amplification via polymerase chain reaction (PCR). The sensor is able to distinguish between positive and negative PCR solutions, to detect the existence of target DNA amplicons in PCR samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.proeng.2016.11.512 SN - 1877-7058 N1 - Proceedings of the 30th anniversary Eurosensors Conference – Eurosensors 2016, 4-7. Sepember 2016, Budapest, Hungary VL - Vol. 168 SP - 514 EP - 517 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wagner, Torsten A1 - Vornholt, Wolfgang A1 - Werner, Frederik A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-Ichiro A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Light-addressable potentiometric sensor (LAPS) combined with magnetic beads for pharmaceutical screening JF - Physics in medicine N2 - The light-addressable potentiometric sensor (LAPS) has the unique feature to address different regions of a sensor surface without the need of complex structures. Measurements at different locations on the sensor surface can be performed in a common analyte solution, which distinctly simplifies the fluidic set-up. However, the measurement in a single analyte chamber prevents the application of different drugs or different concentrations of a drug to each measurement spot at the same time as in the case of multi-reservoir-based set-ups. In this work, the authors designed a LAPS-based set-up for cell culture screening that utilises magnetic beads loaded with the endotoxin (lipopolysaccharides, LPS), to generate a spatially distributed gradient of analyte concentration. Different external magnetic fields can be adjusted to move the magnetic beads loaded with a specific drug within the measurement cell. By recording the metabolic activities of a cell layer cultured on top of the LAPS surface, this work shows the possibility to apply different concentrations of a sample along the LAPS measurement spots within a common analyte solution. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.phmed.2016.03.001 SN - 2352-4510 VL - 2016 IS - 1 SP - 2 EP - 7 ER -