TY - JOUR A1 - Schiffer, Stefan A1 - Ferrein, Alexander T1 - ERIKA—Early Robotics Introduction at Kindergarten Age JF - Multimodal Technologies Interact N2 - In this work, we report on our attempt to design and implement an early introduction to basic robotics principles for children at kindergarten age. One of the main challenges of this effort is to explain complex robotics contents in a way that pre-school children could follow the basic principles and ideas using examples from their world of experience. What sets apart our effort from other work is that part of the lecturing is actually done by a robot itself and that a quiz at the end of the lesson is done using robots as well. The humanoid robot Pepper from Softbank, which is a great platform for human–robot interaction experiments, was used to present a lecture on robotics by reading out the contents to the children making use of its speech synthesis capability. A quiz in a Runaround-game-show style after the lecture activated the children to recap the contents they acquired about how mobile robots work in principle. In this quiz, two LEGO Mindstorm EV3 robots were used to implement a strongly interactive scenario. Besides the thrill of being exposed to a mobile robot that would also react to the children, they were very excited and at the same time very concentrated. We got very positive feedback from the children as well as from their educators. To the best of our knowledge, this is one of only few attempts to use a robot like Pepper not as a tele-teaching tool, but as the teacher itself in order to engage pre-school children with complex robotics contents. Y1 - 2018 U6 - http://dx.doi.org/10.3390/mti2040064 SN - 2414-4088 VL - 2 IS - 4 PB - MDPI CY - Basel ER - TY - JOUR A1 - Schwabedal, Justus T. C. A1 - Sippel, Daniel A1 - Brandt, Moritz D. A1 - Bialonski, Stephan T1 - Automated Classification of Sleep Stages and EEG Artifacts in Mice with Deep Learning N2 - Sleep scoring is a necessary and time-consuming task in sleep studies. In animal models (such as mice) or in humans, automating this tedious process promises to facilitate long-term studies and to promote sleep biology as a data-driven f ield. We introduce a deep neural network model that is able to predict different states of consciousness (Wake, Non-REM, REM) in mice from EEG and EMG recordings with excellent scoring results for out-of-sample data. Predictions are made on epochs of 4 seconds length, and epochs are classified as artifactfree or not. The model architecture draws on recent advances in deep learning and in convolutional neural networks research. In contrast to previous approaches towards automated sleep scoring, our model does not rely on manually defined features of the data but learns predictive features automatically. We expect deep learning models like ours to become widely applied in different fields, automating many repetitive cognitive tasks that were previously difficult to tackle. Y1 - 2018 U6 - http://dx.doi.org/10.48550/arXiv.1809.08443 ER - TY - JOUR A1 - Teumer, T. A1 - Capitain, C. A1 - Ross-Jones, J. A1 - Tippkötter, Nils A1 - Rädle, M. A1 - Methner, F.-J. T1 - In-line Haze Monitoring Using a Spectrally Resolved Back Scattering Sensor JF - BrewingScience N2 - In the present work an optical sensor in combination with a spectrally resolved detection device for in-line particle-size-monitoring for quality control in beer production is presented. The principle relies on the size and wavelength dependent backscatter of growing particles in fluids. Measured interference structures of backscattered light are compared with calculated theoretical values, based on Mie-Theory, and fitted with a linear least square method to obtain particle size distributions. For this purpose, a broadband light source in combination with a process-CCD-spectrometer (charge ? coupled device spectrometer) and process adapted fiber optics are used. The goal is the development of an easy and flexible measurement device for in-line-monitoring of particle size. The presented device can be directly installed in product fill tubes or vessels, follows CIP- (cleaning in place) and removes the need of sample taking. A proof of concept and preliminary results, measuring protein precipitation, are presented. Y1 - 2018 SN - 1613-2041 VL - 71 IS - 5/6 SP - 49 EP - 55 PB - Fachverlag Hans Carl CY - Nürnberg ER - TY - JOUR A1 - Fissabre, Anke A1 - Wilson, Ariane T1 - Der Turm mit zehn Spornen – Ein in Monthoiron gebauter Entwurf von Leonardo Da Vinci? JF - In situ: Zeitschrift für Architekturgeschichte Y1 - 2018 SN - 1866-959X N1 - gedruckt in der Bereichsbibliothek Bayernallee vorhanden. Signatur 13 Z 959-2018 IS - 1 SP - 65 EP - 82 PB - Wernersche Verlagsgesellschaft CY - Worms ER - TY - JOUR A1 - de Blois, Eric A1 - de Zanger, Rory M. S. A1 - Paulßen, Elisabeth A1 - Sze Chan, Ho A1 - Breeman, Wouter A. P. T1 - Semi-automated system for concentrating 68Ga-eluate to obtain high molar and volume concentration of 68Ga-Radiopharmaca for preclinical applications JF - Nuclear Medicine and Biology N2 - 68Ga-radiopharmaceuticals are common in the field of Nuclear Medicine to visualize receptor-mediated processes. In contrast to straightforward labeling procedures for clinical applications, preclinical in vitro and in vivo applications are hampered for reasons like e.g. volume restriction, activity concentration, molar activity and osmolality. Therefore, we developed a semiautomatic system specifically to overcome these problems. A difficulty appeared unexpectedly, as intrinsic trace metals derived from eluate (Zn, Fe and Cu) are concentrated as well in amounts that influence radiochemical yield and thus lower molar activity. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.nucmedbio.2018.06.006 VL - 64-65 SP - 16 EP - 21 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Keutmann, Sabine A1 - Staat, Manfred A1 - Laack, Walter van T1 - Untersuchung der thermischen Auswirkung von therapeutischem Ultraschall N2 - Zusammenfassung: In der Orthopädie zählt der therapeutische Ultraschall als Mittel zur Prävention und Therapiebegleitung. Er hat mechanische, thermische und physiko-chemische Auswirkungen auf den menschlichen Körper. Um mehr Erkenntnisse über die thermischen Auswirkungen zu erlangen, wurden Versuche an einem Hydrogel-Phantom und an Probanden durchgeführt. Dabei entstand eine signifikante Erwärmung des Gewebes, welche beim Probandenversuch an der Oberfläche und beim Hydrogelversuch in der Tiefe gemessen wurde. Summary: In orthopaedics, therapeutic ultrasound is a tool of prevention and therapy support. It has mechanical, thermal and physico-chemical effects on the human body. Tests with a hydrogel phantom and with human probands have been performed in order to obtain more knowledge about their thermal effects. Both tests measured temperature increases in cell tissue, on the surface with the human proband test and in depth with the hydrogel phantom test. T2 - Research about the thermal effects of therapeutic ultrasound Y1 - 2018 SN - 2193-5793 SN - 2193-5785 (Druckausgabe) VL - 7 IS - 10 SP - 518 EP - 522 PB - Deutscher Ärzte-Verl. CY - Köln ER - TY - JOUR A1 - Olbertz, Klaus T1 - Überwachung von Arbeitnehmern als Ausdruck von Compliance - Grundsätze sowie Zulässigkeit und Grenzen einzelner Maßnahmen JF - NWB - Steuer- und Wirtschaftsrecht Y1 - 2018 SN - 1860-9449 IS - 21 SP - 1547 EP - 1555 PB - NWB-Verl. CY - Herne ER - TY - JOUR A1 - Olbertz, Klaus T1 - Das rechtssichere Arbeitszeugnis - Erlaubte und nicht erlaubte Formulierungen und anderes Wissenswertes JF - NWB - Steuer- und Wirtschaftsrecht Y1 - 2018 SN - 1860-9449 IS - 12 SP - 802 EP - 813 PB - NWB-Verl. CY - Herne ER - TY - JOUR A1 - Hüning, Felix A1 - Heuermann, Holger A1 - Wache, Franz-Josef T1 - Wireless CAN JF - Etz: Elektrotechnik & Automation N2 - In modernen elektronischen und mechatronischen Systemen, z. B. im industriellen oder automobil Bereich, kommunizieren eingebettete Steuergeräte und Sensoren vielfach über Bussysteme wie CAN oder LIN. Die Kommunikation findet in der Regel drahtgebunden statt, so dass der Kabelbaum für die Kommunikation sehr groß werden kann. Daher ist es naheliegend, Leitungen und dazugehörige Stecker, z. B. für nicht-sicherheitskritische Komfortsysteme, einzusparen und diese durch gerichtete Funkstrecken für kurze Entfernungen zu ersetzen. Somit könnten Komponenten wie ECUs oder Sensoren kabel- und steckerlos in ein Bussystem integriert werden. Zudem ist eine einfache galvanische und mechanische Trennung zu erreichen. Funkübertragung wird bei diesen Bussystemen derzeit nicht eingesetzt, da insbesondere die Echtzeitfähigkeit und die Robustheit der vorhandenen Funksysteme nicht den Anforderungen der Anwendungen entspricht. Zudem sind bestehende Funksysteme wie WLAN oder Bluetooth im Vergleich zur konventionellen Verkabelung teuer und es besteht hierbei die Möglichkeit, dass sie ausspioniert werden können und so sensible Daten entwendet werden können. In dieser Arbeit wird eine alternative Realisierung zu den bestehenden Funksystemen vorgestellt, die aus wenigen Komponenten aufzubauen ist. Es ist eine protokolllose, echtzeitfähige Übertragung möglich und somit die transparente Integration in ein Bussystem wie CAN. Y1 - 2018 SN - 0170-1711 VL - 139 IS - 10 SP - 22 EP - 26 PB - VDE-Verlag CY - Wuppertal ER - TY - JOUR A1 - Olbertz, Klaus T1 - Der Interimsmanager als Selbständiger oder Arbeitnehmer : Vertragliche Varianten des Interimsmanagements im Faktencheck JF - NWB - Steuer- und Wirtschaftsrecht Y1 - 2018 SN - 1860-9449 IS - 31 SP - 2260 EP - 2266 PB - NWB-Verl. CY - Herne ER -