The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 33 of 187
Back to Result List

Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo

  • Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018.

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Alexander Ciritsis, Andreas HorbachORCiD, Manfred StaatORCiD, Christiane K. Kuhl, Nils Andreas Kraemer
DOI:https://doi.org/10.1002/jbm.b.33877
ISSN:1552-4981
Parent Title (English):Journal of Biomedical Materials Research: Part B: Applied Biomaterials
Publisher:Wiley
Place of publication:New York, NY
Document Type:Article
Language:English
Year of Completion:2018
Date of the Publication (Server):2017/04/10
Volume:106
Issue:2
First Page:827
Last Page:833
Link:http://doi.org/10.1002/jbm.b.33877
Zugriffsart:campus
Institutes:FH Aachen / Fachbereich Medizintechnik und Technomathematik
FH Aachen / IfB - Institut für Bioengineering
collections:Verlag / Wiley